메뉴 건너뛰기




Volumn 1421, Issue , 2015, Pages 18-37

Evolution in miniaturized column liquid chromatography instrumentation and applications: An overview

Author keywords

Capillary columns; Capillary liquid chromatography; Instrumentation; Miniaturized LC; Nano LC

Indexed keywords

CHROMATOGRAPHY; COLUMN CHROMATOGRAPHY; MASS SPECTROMETRY;

EID: 84960488008     PISSN: 00219673     EISSN: 18733778     Source Type: Journal    
DOI: 10.1016/j.chroma.2015.08.051     Document Type: Review
Times cited : (97)

References (151)
  • 1
    • 84887627378 scopus 로고    scopus 로고
    • Capillary-liquid chromatography (CLC) and nano-LC in food analysis
    • Fanali C., Dugo L., Dugo P., Mondello L. Capillary-liquid chromatography (CLC) and nano-LC in food analysis. Trends Anal. Chem. 2013, 52:226-238. 10.1016/j.trac.2013.05.021.
    • (2013) Trends Anal. Chem. , vol.52 , pp. 226-238
    • Fanali, C.1    Dugo, L.2    Dugo, P.3    Mondello, L.4
  • 2
    • 84858793659 scopus 로고    scopus 로고
    • Chiral capillary liquid chromatography based on penicillin G acylase immobilized on monolithic epoxy silica column
    • Gotti R., Fiori J., Calleri E., Temporini C., Lubda D., Massolini G. Chiral capillary liquid chromatography based on penicillin G acylase immobilized on monolithic epoxy silica column. J. Chromatogr. A 2012, 1234:45-49. http://www.sciencedirect.com/science/article/pii/S0021967311017493.
    • (2012) J. Chromatogr. A , vol.1234 , pp. 45-49
    • Gotti, R.1    Fiori, J.2    Calleri, E.3    Temporini, C.4    Lubda, D.5    Massolini, G.6
  • 3
    • 41949094330 scopus 로고    scopus 로고
    • Simultaneous analysis of five antidepressant drugs using direct injection of biofluids in a capillary restricted-access media-liquid chromatography-tandem mass spectrometry system
    • Santos-Neto A.J., Bergquist J., Lanças F.M., Sjöberg P.J.R. Simultaneous analysis of five antidepressant drugs using direct injection of biofluids in a capillary restricted-access media-liquid chromatography-tandem mass spectrometry system. J. Chromatogr. A 2008, 1189:514-522. 10.1016/j.chroma.2008.02.107.
    • (2008) J. Chromatogr. A , vol.1189 , pp. 514-522
    • Santos-Neto, A.J.1    Bergquist, J.2    Lanças, F.M.3    Sjöberg, P.J.R.4
  • 4
    • 0014144236 scopus 로고
    • Fast liquid chromatography. Investigation of operating parameters and the separation of nucleotides on pellicular ion exchangers
    • Horvath C.G., Preiss B.A., Lipsky S.R. Fast liquid chromatography. Investigation of operating parameters and the separation of nucleotides on pellicular ion exchangers. Anal. Chem. 1967, 39:1422-1428.
    • (1967) Anal. Chem. , vol.39 , pp. 1422-1428
    • Horvath, C.G.1    Preiss, B.A.2    Lipsky, S.R.3
  • 5
    • 0001340533 scopus 로고
    • A study of micro-high-performance liquid chromatography. I. Development of technique for miniaturization of high-performance liquid chromatography
    • Ishii D., Asai K., Hibi K., Jonokuchi T., Nagaya M. A study of micro-high-performance liquid chromatography. I. Development of technique for miniaturization of high-performance liquid chromatography. J. Chromatogr. 1977, 144:157-168. http://www.scopus.com/inward/record.url?eid=2-s2.0-0001340533%26partnerID=40%26md5=64b889013d900ed20ee359e128e0d0b6.
    • (1977) J. Chromatogr. , vol.144 , pp. 157-168
    • Ishii, D.1    Asai, K.2    Hibi, K.3    Jonokuchi, T.4    Nagaya, M.5
  • 6
    • 49249147257 scopus 로고
    • Mode of operation and performance characteristics of microbore columns for use in liquid chromatography
    • Scott R.P.W., Kucera P. Mode of operation and performance characteristics of microbore columns for use in liquid chromatography. J. Chromatogr. 1979, 169:51-72. http://www.scopus.com/inward/record.url?eid=2-s2.0-49249147257%26partnerID=40%26md5=dd9ad4a71d791fcc82fd610c3f2ee630.
    • (1979) J. Chromatogr. , vol.169 , pp. 51-72
    • Scott, R.P.W.1    Kucera, P.2
  • 7
    • 0017935859 scopus 로고
    • Packed microcapillary columns in high performance liquid chromatography
    • Novotny M. Packed microcapillary columns in high performance liquid chromatography. Anal. Chem. 1978, 50:271-275. http://www.scopus.com/inward/record.url?eid=2-s2.0-0017935859%26partnerID=40%26md5=3d4891b7bd869a17df6f26e990cbfad2.
    • (1978) Anal. Chem. , vol.50 , pp. 271-275
    • Novotny, M.1
  • 8
    • 0000261091 scopus 로고
    • Techniques of capillary liquid chromatography
    • Hirata Y., Novotny M. Techniques of capillary liquid chromatography. J. Chromatogr. 1979, 186:521-528. http://www.sciencedirect.com/science/article/pii/S0021967300952725.
    • (1979) J. Chromatogr. , vol.186 , pp. 521-528
    • Hirata, Y.1    Novotny, M.2
  • 9
    • 0242365143 scopus 로고    scopus 로고
    • Capillary columns in liquid chromatography
    • Takeuchi T. Capillary columns in liquid chromatography. Anal. Bioanal. Chem. 2003, 375:26-27. 10.1007/s00216-002-1619-x.
    • (2003) Anal. Bioanal. Chem. , vol.375 , pp. 26-27
    • Takeuchi, T.1
  • 10
    • 31344453916 scopus 로고    scopus 로고
    • Development of capillary liquid chromatography
    • Takeuchi T. Development of capillary liquid chromatography. Chromatography 2005, 26:7-10. http://wwwsoc.nii.ac.jp/scs/Journal/Vol_26/abs26-1_007.html.
    • (2005) Chromatography , vol.26 , pp. 7-10
    • Takeuchi, T.1
  • 12
    • 84904627049 scopus 로고    scopus 로고
    • Novel devices for solvent delivery and temperature programming designed for capillary liquid chromatography
    • Coutinho L.F.M., Nazario C.E.D., Monteiro A.M., Lanças F.M. Novel devices for solvent delivery and temperature programming designed for capillary liquid chromatography. J. Sep. Sci. 2014, 37:1903-1910. 10.1002/jssc.201301324.
    • (2014) J. Sep. Sci. , vol.37 , pp. 1903-1910
    • Coutinho, L.F.M.1    Nazario, C.E.D.2    Monteiro, A.M.3    Lanças, F.M.4
  • 13
    • 33847309138 scopus 로고    scopus 로고
    • Elevated temperature-extended column length conventional liquid chromatography to increase peak capacity for the analysis of tryptic digests
    • Sandra P., Vanhoenacker G. Elevated temperature-extended column length conventional liquid chromatography to increase peak capacity for the analysis of tryptic digests. J. Sep. Sci. 2007, 30:241-244. http://www.scopus.com/inward/record.url?eid=2-s2.0-33847309138%26partnerID=40%26md5=11446f9c00fd36dc8d298fe43a67bf1d.
    • (2007) J. Sep. Sci. , vol.30 , pp. 241-244
    • Sandra, P.1    Vanhoenacker, G.2
  • 14
    • 79954627143 scopus 로고    scopus 로고
    • General strategy for performing temperature programming in high performance liquid chromatography: prediction of linear temperature gradients
    • Wiese S., Teutenberg T., Schmidt T.C. General strategy for performing temperature programming in high performance liquid chromatography: prediction of linear temperature gradients. Anal. Chem. 2011, 83:2227-2233. 10.1021/ac103113m.
    • (2011) Anal. Chem. , vol.83 , pp. 2227-2233
    • Wiese, S.1    Teutenberg, T.2    Schmidt, T.C.3
  • 15
    • 0141782556 scopus 로고    scopus 로고
    • Extracolumn band broadening in capillary liquid chromatography
    • Prüß A., Kempter C., Gysler J., Jira T. Extracolumn band broadening in capillary liquid chromatography. J. Chromatogr. A 2003, 1016:129-141. 10.1016/S0021-9673(03)01290-1.
    • (2003) J. Chromatogr. A , vol.1016 , pp. 129-141
    • Prüß, A.1    Kempter, C.2    Gysler, J.3    Jira, T.4
  • 16
    • 0037041585 scopus 로고    scopus 로고
    • Superheated water eluent capillary liquid chromatography
    • Scottkephart T., Dasgupta P. Superheated water eluent capillary liquid chromatography. Talanta 2002, 56:977-987. 10.1016/S0039-9140(02)00049-8.
    • (2002) Talanta , vol.56 , pp. 977-987
    • Scottkephart, T.1    Dasgupta, P.2
  • 17
    • 80052093435 scopus 로고    scopus 로고
    • Recent developments and applications of molecularly imprinted monolithic column for HPLC and CEC
    • Zheng C., Huang Y.P., Liu Z.S. Recent developments and applications of molecularly imprinted monolithic column for HPLC and CEC. J. Sep. Sci. 2011, 34:1988-2002. 10.1002/jssc.201100164.
    • (2011) J. Sep. Sci. , vol.34 , pp. 1988-2002
    • Zheng, C.1    Huang, Y.P.2    Liu, Z.S.3
  • 19
    • 0037705298 scopus 로고    scopus 로고
    • Liquid flow in capillary (electro)chromatography: generation and control of micro- and nanoliter volumes
    • Rapp E., Tallarek U. Liquid flow in capillary (electro)chromatography: generation and control of micro- and nanoliter volumes. J. Sep. Sci. 2003, 26:453-470. 10.1002/jssc.200390062.
    • (2003) J. Sep. Sci. , vol.26 , pp. 453-470
    • Rapp, E.1    Tallarek, U.2
  • 20
    • 0037355259 scopus 로고    scopus 로고
    • Variable-gradient generator for micro- and nano-HPLC
    • (accessed 29.07.15)
    • Cappiello A., Famiglini G., Fiorucci C., Mangani F., Palma P., Siviero A. Variable-gradient generator for micro- and nano-HPLC. Anal. Chem. 2003, 75:1173-1179. (accessed 29.07.15). http://www.scopus.com/inward/record.url?eid=2-s2.0-0037355259%26partnerID=tZOtx3y1.
    • (2003) Anal. Chem. , vol.75 , pp. 1173-1179
    • Cappiello, A.1    Famiglini, G.2    Fiorucci, C.3    Mangani, F.4    Palma, P.5    Siviero, A.6
  • 22
    • 84960548402 scopus 로고    scopus 로고
    • (accessed 13.06.15).
    • AB Sciex, 2015. Available at: (accessed 13.06.15). http://sciex.com/.
    • (2015)
  • 23
    • 84960548403 scopus 로고    scopus 로고
    • (accessed 13.06.15).
    • Agilent Technologies, 2015. Available at: (accessed 13.06.15). http://www.agilent.com/home.
    • (2015)
  • 24
    • 84960548404 scopus 로고    scopus 로고
    • (accessed 13.06.15).
    • Thermo Fisher Scientific, 2015. Available at: (accessed 13.06.15). http://www.thermoscientific.com/en/home.html.
    • (2015)
  • 25
    • 84960548405 scopus 로고    scopus 로고
    • (accessed 13.06.15).
    • Waters Corporation, 2015. Available at: (accessed 13.06.15). http://www.waters.com/waters/home.htm.
    • (2015)
  • 26
    • 84960548406 scopus 로고    scopus 로고
    • (accessed 13.06.15).
    • Shimadzu Corporation, 2015. Available at: (accessed 13.06.15). http://www.shimadzu.com/.
    • (2015)
  • 27
    • 84960548407 scopus 로고    scopus 로고
    • (accessed 13.06.15).
    • Eldex Laboratories, 2015. Available at: (accessed 13.06.15). http://www.eldex.com/.
    • (2015)
  • 28
    • 84960548408 scopus 로고    scopus 로고
    • (accessed 16.06.15).
    • Prolab Instruments GmbH, 2015. Available at: (accessed 16.06.15). http://www.prolab.ch/index.html.
    • (2015)
  • 29
    • 33749245435 scopus 로고    scopus 로고
    • Sub-2 μm porous and nonporous particles for fast separation in reversed-phase high performance liquid chromatography
    • Wu N., Liu Y., Lee M.L. Sub-2 μm porous and nonporous particles for fast separation in reversed-phase high performance liquid chromatography. J. Chromatogr. A 2006, 1131:142-150. 10.1016/j.chroma.2006.07.042.
    • (2006) J. Chromatogr. A , vol.1131 , pp. 142-150
    • Wu, N.1    Liu, Y.2    Lee, M.L.3
  • 30
    • 0031569131 scopus 로고    scopus 로고
    • Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns
    • MacNair J.E., Lewis K.C., Jorgenson J.W. Ultrahigh-pressure reversed-phase liquid chromatography in packed capillary columns. Anal. Chem. 1997, 69:983-989. 10.1021/ac961094.
    • (1997) Anal. Chem. , vol.69 , pp. 983-989
    • MacNair, J.E.1    Lewis, K.C.2    Jorgenson, J.W.3
  • 31
    • 33644755630 scopus 로고    scopus 로고
    • Improved protein recovery in reversed-phase liquid chromatography by the use of ultrahigh pressures
    • Eschelbach J.W., Jorgenson J.W. Improved protein recovery in reversed-phase liquid chromatography by the use of ultrahigh pressures. Anal. Chem. 2006, 78:1697-1706. 10.1021/ac0518304.
    • (2006) Anal. Chem. , vol.78 , pp. 1697-1706
    • Eschelbach, J.W.1    Jorgenson, J.W.2
  • 32
    • 0032403166 scopus 로고    scopus 로고
    • A simplified gradient solvent delivery system for capillary liquid chromatography-electrospray ionization mass spectrometry
    • Ducret A., Bartone N., Haynes P.A., Blanchard A., Aebersold R. A simplified gradient solvent delivery system for capillary liquid chromatography-electrospray ionization mass spectrometry. Anal. Biochem. 1998, 265:129-138. 10.1006/abio.1998.2873.
    • (1998) Anal. Biochem. , vol.265 , pp. 129-138
    • Ducret, A.1    Bartone, N.2    Haynes, P.A.3    Blanchard, A.4    Aebersold, R.5
  • 33
    • 0028052107 scopus 로고
    • Generation of split-flow micro-gradients for capillary HPLC
    • Berloni A., Cappiello A., Famiglini G., Palma P. Generation of split-flow micro-gradients for capillary HPLC. Chromatographia 1994, 39:279-284. 10.1007/BF02274514.
    • (1994) Chromatographia , vol.39 , pp. 279-284
    • Berloni, A.1    Cappiello, A.2    Famiglini, G.3    Palma, P.4
  • 34
    • 23944493684 scopus 로고    scopus 로고
    • Capillary high-performance liquid chromatography/electrospray ion trap time-of-flight mass spectrometry using a novel nanoflow gradient generator
    • Ito S., Yoshioka S., Ogata I., Yamashita E., Nagai S., Okumoto T., et al. Capillary high-performance liquid chromatography/electrospray ion trap time-of-flight mass spectrometry using a novel nanoflow gradient generator. J. Chromatogr. A 2005, 1090:178-183. 10.1016/j.chroma.2005.06.096.
    • (2005) J. Chromatogr. A , vol.1090 , pp. 178-183
    • Ito, S.1    Yoshioka, S.2    Ogata, I.3    Yamashita, E.4    Nagai, S.5    Okumoto, T.6
  • 35
    • 0033082675 scopus 로고    scopus 로고
    • Ultrahigh-pressure reversed-phase capillary liquid chromatography: isocratic and gradient elution using columns packed with 1.0 μm particles
    • MacNair J.E., Patel K.D., Jorgenson J.W. Ultrahigh-pressure reversed-phase capillary liquid chromatography: isocratic and gradient elution using columns packed with 1.0 μm particles. Anal. Chem. 1999, 71:700-708. 10.1021/ac9807013.
    • (1999) Anal. Chem. , vol.71 , pp. 700-708
    • MacNair, J.E.1    Patel, K.D.2    Jorgenson, J.W.3
  • 36
    • 0035565263 scopus 로고    scopus 로고
    • An exponential dilution gradient system for nanoscale liquid chromatography in combination with MALDI or nano-ESI mass spectrometry for proteolytic digests
    • Doneanu C.E., Griffin D.A., Barofsky E.L., Barofsky D.F. An exponential dilution gradient system for nanoscale liquid chromatography in combination with MALDI or nano-ESI mass spectrometry for proteolytic digests. J. Am. Soc. Mass Spectrom. 2001, 12:1205-1213. 10.1016/S1044-0305(01)00307-5.
    • (2001) J. Am. Soc. Mass Spectrom. , vol.12 , pp. 1205-1213
    • Doneanu, C.E.1    Griffin, D.A.2    Barofsky, E.L.3    Barofsky, D.F.4
  • 37
    • 0035853629 scopus 로고    scopus 로고
    • New micro-flow pumping system for liquid chromatography
    • Zhou X., Furushima N., Terashima C., Tanaka H., Kurano M. New micro-flow pumping system for liquid chromatography. J. Chromatogr. A 2001, 913:165-171. 10.1016/S0021-9673(01)00535-0.
    • (2001) J. Chromatogr. A , vol.913 , pp. 165-171
    • Zhou, X.1    Furushima, N.2    Terashima, C.3    Tanaka, H.4    Kurano, M.5
  • 38
    • 84872490802 scopus 로고    scopus 로고
    • Simple automated liquid chromatographic system for splitless nano column gradient separations
    • Sesták J., Duša F., Moravcová D., Kahle V. Simple automated liquid chromatographic system for splitless nano column gradient separations. J. Chromatogr. A 2013, 1276:26-32. 10.1016/j.chroma.2012.12.020.
    • (2013) J. Chromatogr. A , vol.1276 , pp. 26-32
    • Sesták, J.1    Duša, F.2    Moravcová, D.3    Kahle, V.4
  • 39
    • 84960548409 scopus 로고    scopus 로고
    • (accessed 19.06.15).
    • Valco Instruments Company Incorporated, 2015. Available at: (accessed 19.06.15). http://www.vici.com/.
    • (2015)
  • 40
    • 0030821591 scopus 로고    scopus 로고
    • Microcolumn liquid chromatography: instrumentation, detection and applications
    • Vissers J.P.C.C., Claessens H.A., Cramers C.A. Microcolumn liquid chromatography: instrumentation, detection and applications. J. Chromatogr. A 1997, 779:1-28. 10.1016/S0021-9673(97)00422-6.
    • (1997) J. Chromatogr. A , vol.779 , pp. 1-28
    • Vissers, J.P.C.C.1    Claessens, H.A.2    Cramers, C.A.3
  • 41
    • 0032859642 scopus 로고    scopus 로고
    • Recent developments in microcolumn liquid chromatography
    • Vissers J.P.C. Recent developments in microcolumn liquid chromatography. J. Chromatogr. A 1999, 856:117-143. 10.1016/S0021-9673(99)00692-5.
    • (1999) J. Chromatogr. A , vol.856 , pp. 117-143
    • Vissers, J.P.C.1
  • 42
    • 0031770420 scopus 로고    scopus 로고
    • Micro and capillary liquid chromatography-tandem mass spectrometry: a new dimension in phytohormone research
    • Prinsen E., Van Dongen W., Esmans E.L., Van Onckelen H.A. Micro and capillary liquid chromatography-tandem mass spectrometry: a new dimension in phytohormone research. J. Chromatogr. A 1998, 826:25-37. 10.1016/S0021-9673(98)00763-8.
    • (1998) J. Chromatogr. A , vol.826 , pp. 25-37
    • Prinsen, E.1    Van Dongen, W.2    Esmans, E.L.3    Van Onckelen, H.A.4
  • 43
    • 48749141577 scopus 로고
    • Dispersion measurements on conventional and miniaturised HPLC systems
    • Freebairn K.W., Knox J.H. Dispersion measurements on conventional and miniaturised HPLC systems. Chromatographia 1984, 19:37-47. 10.1007/BF02687717.
    • (1984) Chromatographia , vol.19 , pp. 37-47
    • Freebairn, K.W.1    Knox, J.H.2
  • 44
    • 0036494664 scopus 로고    scopus 로고
    • State of the art in miniaturized separation techniques
    • Szumski M., Buszewski B. State of the art in miniaturized separation techniques. Crit. Rev. Anal. Chem. 2002, 32:1-46. 10.1080/10408340290765434.
    • (2002) Crit. Rev. Anal. Chem. , vol.32 , pp. 1-46
    • Szumski, M.1    Buszewski, B.2
  • 45
    • 84960548410 scopus 로고    scopus 로고
    • (accessed 24.06.15).
    • IDEX Health & Science, 2015. Available at: (accessed 24.06.15). https://www.idex-hs.com/.
    • (2015)
  • 46
    • 84960548411 scopus 로고    scopus 로고
    • (accessed 24.06.15).
    • New Objective, 2015. Available at: (accessed 24.06.15). http://www.newobjective.com/index.shtml.
    • (2015)
  • 47
    • 84960548412 scopus 로고    scopus 로고
    • (accessed 24.06.15).
    • SGE Analytical Science, 2015. Available at: (accessed 24.06.15). http://www.sge.com/home/.
    • (2015)
  • 48
    • 0038518083 scopus 로고
    • A performance index for gas chromatographic columns
    • Golay M.J.E. A performance index for gas chromatographic columns. Nature 1957, 180:435-436. 10.1038/180435b0.
    • (1957) Nature , vol.180 , pp. 435-436
    • Golay, M.J.E.1
  • 49
    • 0024083278 scopus 로고
    • Separation efficiency of slurry-packed liquid chromatography microcolumns with very small inner diameters
    • Karlsson K.E., Novotny M. Separation efficiency of slurry-packed liquid chromatography microcolumns with very small inner diameters. Anal. Chem. 1988, 60:1662-1665. 10.1021/ac00168a006.
    • (1988) Anal. Chem. , vol.60 , pp. 1662-1665
    • Karlsson, K.E.1    Novotny, M.2
  • 50
    • 33845184448 scopus 로고
    • Preparation and evaluation of packed capillary liquid chromatography columns with inner diameters from 20 to 50 μm
    • Kennedy R.T., Jorgenson J.W. Preparation and evaluation of packed capillary liquid chromatography columns with inner diameters from 20 to 50 μm. Anal. Chem. 1989, 61:1128-1135. 10.1021/ac00185a016.
    • (1989) Anal. Chem. , vol.61 , pp. 1128-1135
    • Kennedy, R.T.1    Jorgenson, J.W.2
  • 51
    • 84894226959 scopus 로고    scopus 로고
    • Porous layer open tubular columns in capillary liquid chromatography
    • Collins D.A., Nesterenko E.P., Paull B. Porous layer open tubular columns in capillary liquid chromatography. Analyst 2014, 139:1292-1302. 10.1039/c3an01869e.
    • (2014) Analyst , vol.139 , pp. 1292-1302
    • Collins, D.A.1    Nesterenko, E.P.2    Paull, B.3
  • 52
    • 12144268304 scopus 로고    scopus 로고
    • Capillary columns in liquid chromatography: between conventional columns and microchips
    • Saito Y., Jinno K., Greibrokk T. Capillary columns in liquid chromatography: between conventional columns and microchips. J. Sep. Sci. 2004, 27:1379-1390. 10.1002/jssc.200401902.
    • (2004) J. Sep. Sci. , vol.27 , pp. 1379-1390
    • Saito, Y.1    Jinno, K.2    Greibrokk, T.3
  • 53
    • 84857063749 scopus 로고    scopus 로고
    • Quest for organic polymer-based monolithic columns affording enhanced efficiency in high performance liquid chromatography separations of small molecules in isocratic mode
    • Svec F. Quest for organic polymer-based monolithic columns affording enhanced efficiency in high performance liquid chromatography separations of small molecules in isocratic mode. J. Chromatogr. A 2012, 1228:250-262. 10.1016/j.chroma.2011.07.019.
    • (2012) J. Chromatogr. A , vol.1228 , pp. 250-262
    • Svec, F.1
  • 54
    • 75749123448 scopus 로고    scopus 로고
    • Silica spheres coated with C18-modified gold nanoparticles for capillary LC and pressurized CEC separations
    • Qu Q., Peng S., Mangelings D., Hu X., Yan C. Silica spheres coated with C18-modified gold nanoparticles for capillary LC and pressurized CEC separations. Electrophoresis 2010, 31:556-562. 10.1002/elps.200900375.
    • (2010) Electrophoresis , vol.31 , pp. 556-562
    • Qu, Q.1    Peng, S.2    Mangelings, D.3    Hu, X.4    Yan, C.5
  • 55
    • 84904999136 scopus 로고    scopus 로고
    • Core-shell particles: preparation, fundamentals and applications in high performance liquid chromatography
    • Hayes R., Ahmed A., Edge T., Zhang H. Core-shell particles: preparation, fundamentals and applications in high performance liquid chromatography. J. Chromatogr. A 2014, 1357:36-52. 10.1016/j.chroma.2014.05.010.
    • (2014) J. Chromatogr. A , vol.1357 , pp. 36-52
    • Hayes, R.1    Ahmed, A.2    Edge, T.3    Zhang, H.4
  • 56
    • 84960548413 scopus 로고    scopus 로고
    • (accessed 21.06.15).
    • Advanced Materials Technology, 2015. Available at: (accessed 21.06.15). http://www.advanced-materials-tech.com/.
    • (2015)
  • 57
    • 84960548414 scopus 로고    scopus 로고
    • (accessed 21.06.15).
    • Phenomenex, 2015. Available at: (accessed 21.06.15). http://www.phenomenex.com/.
    • (2015)
  • 58
    • 84960548415 scopus 로고    scopus 로고
    • (accessed 21.06.15).
    • Sigma-Aldrich, 2015. Available at: (accessed 21.06.15). http://www.sigmaaldrich.com/.
    • (2015)
  • 59
    • 84960548416 scopus 로고    scopus 로고
    • (accessed 21.06.15).
    • ChromaNik Technologies, 2015. Available at: (accessed 21.06.15). http://www.chromanik.co.jp/englishindex.html.
    • (2015)
  • 60
    • 84960548417 scopus 로고    scopus 로고
    • (accessed 21.06.15).
    • KNAUER, 2015. Available at: (accessed 21.06.15). http://www.knauer.net/en.html.
    • (2015)
  • 61
    • 84911864201 scopus 로고    scopus 로고
    • Recent innovations in UHPLC columns and instrumentation
    • Walter T.H., Andrews R.W. Recent innovations in UHPLC columns and instrumentation. Trends Anal. Chem. 2014, 63:14-20. 10.1016/j.trac.2014.07.016.
    • (2014) Trends Anal. Chem. , vol.63 , pp. 14-20
    • Walter, T.H.1    Andrews, R.W.2
  • 62
    • 84908068266 scopus 로고    scopus 로고
    • A new approach for plasma (xeno)metabolomics based on solid-phase extraction and nanoflow liquid chromatography-nanoelectrospray ionisation mass spectrometry
    • David A., Abdul-Sada A., Lange A., Tyler C.R., Hill E.M. A new approach for plasma (xeno)metabolomics based on solid-phase extraction and nanoflow liquid chromatography-nanoelectrospray ionisation mass spectrometry. J. Chromatogr. A 2014, 1365:72-85. 10.1016/j.chroma.2014.09.001.
    • (2014) J. Chromatogr. A , vol.1365 , pp. 72-85
    • David, A.1    Abdul-Sada, A.2    Lange, A.3    Tyler, C.R.4    Hill, E.M.5
  • 63
    • 84908670427 scopus 로고    scopus 로고
    • Evaluation of analytical performance and reliability of direct nanoLC-nanoESI-high resolution mass spectrometry for profiling the (xeno)metabolome
    • Chetwynd A.J., David A., Hill E.M., Abdul-Sada A. Evaluation of analytical performance and reliability of direct nanoLC-nanoESI-high resolution mass spectrometry for profiling the (xeno)metabolome. J. Mass Spectrom. 2014, 49:1063-1069. 10.1002/jms.3426.
    • (2014) J. Mass Spectrom. , vol.49 , pp. 1063-1069
    • Chetwynd, A.J.1    David, A.2    Hill, E.M.3    Abdul-Sada, A.4
  • 64
    • 84896352396 scopus 로고    scopus 로고
    • Fritting techniques in chromatography
    • Cheong W.J. Fritting techniques in chromatography. J. Sep. Sci. 2014, 37:603-617. 10.1002/jssc.201301239.
    • (2014) J. Sep. Sci. , vol.37 , pp. 603-617
    • Cheong, W.J.1
  • 65
    • 84892598263 scopus 로고    scopus 로고
    • Recent advances of polymer monolithic columns functionalized with micro/nanomaterials: synthesis and application
    • Tong S., Liu S., Wang H., Jia Q. Recent advances of polymer monolithic columns functionalized with micro/nanomaterials: synthesis and application. Chromatographia 2014, 77:5-14. 10.1007/s10337-013-2564-x.
    • (2014) Chromatographia , vol.77 , pp. 5-14
    • Tong, S.1    Liu, S.2    Wang, H.3    Jia, Q.4
  • 66
    • 0037188767 scopus 로고    scopus 로고
    • Monolithic silica columns with various skeleton sizes and through-pore sizes for capillary liquid chromatography
    • Motokawa M., Kobayashi H., Ishizuka N., Minakuchi H., Nakanishi K., Jinnai H., et al. Monolithic silica columns with various skeleton sizes and through-pore sizes for capillary liquid chromatography. J. Chromatogr. A 2002, 961:53-63. 10.1016/S0021-9673(02)00133-4.
    • (2002) J. Chromatogr. A , vol.961 , pp. 53-63
    • Motokawa, M.1    Kobayashi, H.2    Ishizuka, N.3    Minakuchi, H.4    Nakanishi, K.5    Jinnai, H.6
  • 67
    • 0037188767 scopus 로고    scopus 로고
    • Monolithic silica columns with various skeleton sizes and through-pore sizes for capillary liquid chromatography
    • Motokawa M., Kobayashi H., Ishizuka N., Minakuchi H., Nakanishi K., Jinnai H., et al. Monolithic silica columns with various skeleton sizes and through-pore sizes for capillary liquid chromatography. J. Chromatogr. A 2002, 10.1016/S0021-9673(02)00133-4.
    • (2002) J. Chromatogr. A
    • Motokawa, M.1    Kobayashi, H.2    Ishizuka, N.3    Minakuchi, H.4    Nakanishi, K.5    Jinnai, H.6
  • 68
    • 60649090661 scopus 로고    scopus 로고
    • Effect of capillary cross-section geometry and size on the separation of proteins in gradient mode using monolithic poly(butyl methacrylate-co-ethylene dimethacrylate) columns
    • Nischang I., Svec F., Fréchet J.M.J. Effect of capillary cross-section geometry and size on the separation of proteins in gradient mode using monolithic poly(butyl methacrylate-co-ethylene dimethacrylate) columns. J. Chromatogr. A 2009, 1216:2355-2361. 10.1016/j.chroma.2009.01.007.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 2355-2361
    • Nischang, I.1    Svec, F.2    Fréchet, J.M.J.3
  • 69
    • 79958116702 scopus 로고    scopus 로고
    • Porous polymer monoliths for small molecule separations: advancements and limitations
    • Nischang I., Teasdale I., Brüggemann O. Porous polymer monoliths for small molecule separations: advancements and limitations. Anal. Bioanal. Chem. 2011, 400:2289-2304. 10.1007/s00216-010-4579-6.
    • (2011) Anal. Bioanal. Chem. , vol.400 , pp. 2289-2304
    • Nischang, I.1    Teasdale, I.2    Brüggemann, O.3
  • 70
    • 33846258757 scopus 로고    scopus 로고
    • Preparation and evaluation of a molecularly imprinted polymer derivatized silica monolithic column for capillary electrochromatography and capillary liquid chromatography
    • Ou J., Li X., Feng S., Dong J., Dong X., Kong L., et al. Preparation and evaluation of a molecularly imprinted polymer derivatized silica monolithic column for capillary electrochromatography and capillary liquid chromatography. Anal. Chem. 2007, 79:639-646. 10.1021/ac061475x.
    • (2007) Anal. Chem. , vol.79 , pp. 639-646
    • Ou, J.1    Li, X.2    Feng, S.3    Dong, J.4    Dong, X.5    Kong, L.6
  • 72
    • 0000779581 scopus 로고
    • Liquid chromatography in open-tubular columns theory of column optimization with limited pressure and analysis time, and fabrication of chemically bonded reversed-phase columns on etched borosilicate glass capillaries
    • Jorgenson J.W., Guthrie E.J. Liquid chromatography in open-tubular columns theory of column optimization with limited pressure and analysis time, and fabrication of chemically bonded reversed-phase columns on etched borosilicate glass capillaries. J. Chromatogr. 1983, 255:335-348. 10.1016/S0021-9673(01)88293-5.
    • (1983) J. Chromatogr. , vol.255 , pp. 335-348
    • Jorgenson, J.W.1    Guthrie, E.J.2
  • 73
    • 0030821591 scopus 로고    scopus 로고
    • Microcolumn liquid chromatography: instrumentation, detection and applications
    • Vlssers J.R., Claessens H.A., Cramers C.A. Microcolumn liquid chromatography: instrumentation, detection and applications. J. Chromatogr. A 1997, 779:1-28. 10.1016/S0021-9673(97)00422-6.
    • (1997) J. Chromatogr. A , vol.779 , pp. 1-28
    • Vlssers, J.R.1    Claessens, H.A.2    Cramers, C.A.3
  • 74
    • 33847001297 scopus 로고    scopus 로고
    • Ultratrace LC/MS proteomic analysis using 10-μm-i.d. porous layer open tubular poly (styrene-divinylbenzene) capillary columns
    • Yue G., Luo Q., Zhang J., Wu S., Karger B.L. Ultratrace LC/MS proteomic analysis using 10-μm-i.d. porous layer open tubular poly (styrene-divinylbenzene) capillary columns. Anal. Chem. 2007, 79:938-946. 10.1021/ac061411m.
    • (2007) Anal. Chem. , vol.79 , pp. 938-946
    • Yue, G.1    Luo, Q.2    Zhang, J.3    Wu, S.4    Karger, B.L.5
  • 75
    • 84868115294 scopus 로고    scopus 로고
    • Synthesis and characterization of new generation open tubular silica capillaries for liquid chromatography
    • Forster S., Kolmar H., Altmaier S. Synthesis and characterization of new generation open tubular silica capillaries for liquid chromatography. J. Chromatogr. A 2012, 10.1016/j.chroma.2012.09.054.
    • (2012) J. Chromatogr. A
    • Forster, S.1    Kolmar, H.2    Altmaier, S.3
  • 76
    • 42649083723 scopus 로고    scopus 로고
    • Two-dimensional strong cation exchange/porous layer open tubular/mass spectrometry for ultratrace proteomic analysis using a 10 μm id poly(styrene-divinylbenzene) porous layer open tubular column with an on-line triphasic trapping column
    • Luo Q., Gu Y., Wu S.L., Rejtar T., Karger B.L. Two-dimensional strong cation exchange/porous layer open tubular/mass spectrometry for ultratrace proteomic analysis using a 10 μm id poly(styrene-divinylbenzene) porous layer open tubular column with an on-line triphasic trapping column. Electrophoresis 2008, 29:1604-1611. 10.1002/elps.200700741.
    • (2008) Electrophoresis , vol.29 , pp. 1604-1611
    • Luo, Q.1    Gu, Y.2    Wu, S.L.3    Rejtar, T.4    Karger, B.L.5
  • 77
    • 84874490575 scopus 로고    scopus 로고
    • Polyanionic and polyzwitterionic azobenzene ionic liquid-functionalized silica materials and their chromatographic applications
    • Qiu H., Jiang S., Takafuji M., Ihara H. Polyanionic and polyzwitterionic azobenzene ionic liquid-functionalized silica materials and their chromatographic applications. Chem. Commun. 2013, 49:2454-2456. 10.1039/c3cc00138e.
    • (2013) Chem. Commun. , vol.49 , pp. 2454-2456
    • Qiu, H.1    Jiang, S.2    Takafuji, M.3    Ihara, H.4
  • 78
    • 80054681742 scopus 로고    scopus 로고
    • Microproteomic analysis of 10,000 laser captured microdissected breast tumor cells using short-range sodium dodecyl sulfate-polyacrylamide gel electrophoresis and porous layer open tubular liquid chromatography tandem mass spectrometry
    • Thakur D., Rejtar T., Wang D., Bones J., Cha S., Clodfelder-Miller B., et al. Microproteomic analysis of 10,000 laser captured microdissected breast tumor cells using short-range sodium dodecyl sulfate-polyacrylamide gel electrophoresis and porous layer open tubular liquid chromatography tandem mass spectrometry. J. Chromatogr. A 2011, 1218:8168-8174. 10.1016/j.chroma.2011.09.022.
    • (2011) J. Chromatogr. A , vol.1218 , pp. 8168-8174
    • Thakur, D.1    Rejtar, T.2    Wang, D.3    Bones, J.4    Cha, S.5    Clodfelder-Miller, B.6
  • 79
    • 77953692655 scopus 로고    scopus 로고
    • Separation of intact proteins on porous layer open tubular (PLOT) columns
    • Rogeberg M., Wilson S.R., Greibrokk T., Lundanes E. Separation of intact proteins on porous layer open tubular (PLOT) columns. J. Chromatogr. A 2010, 1217:2782-2786. 10.1016/j.chroma.2010.02.025.
    • (2010) J. Chromatogr. A , vol.1217 , pp. 2782-2786
    • Rogeberg, M.1    Wilson, S.R.2    Greibrokk, T.3    Lundanes, E.4
  • 80
    • 84883574529 scopus 로고    scopus 로고
    • Separation optimization of long porous-layer open-tubular columns for nano-LC-MS of limited proteomic samples
    • Rogeberg M., Vehus T., Grutle L., Greibrokk T., Wilson S.R., Lundanes E. Separation optimization of long porous-layer open-tubular columns for nano-LC-MS of limited proteomic samples. J. Sep. Sci. 2013, 36:2838-2847. 10.1002/jssc.201300499.
    • (2013) J. Sep. Sci. , vol.36 , pp. 2838-2847
    • Rogeberg, M.1    Vehus, T.2    Grutle, L.3    Greibrokk, T.4    Wilson, S.R.5    Lundanes, E.6
  • 81
    • 84907153239 scopus 로고    scopus 로고
    • Open tubular lab-on-column/mass spectrometry for targeted proteomics of nanogram sample amounts
    • Hustoft H.K., Vehus T., Brandtzaeg O.K., Krauss S., Greibrokk T., Wilson S.R., et al. Open tubular lab-on-column/mass spectrometry for targeted proteomics of nanogram sample amounts. PLOS ONE 2014, 9:1-10. 10.1371/journal.pone.0106881.
    • (2014) PLOS ONE , vol.9 , pp. 1-10
    • Hustoft, H.K.1    Vehus, T.2    Brandtzaeg, O.K.3    Krauss, S.4    Greibrokk, T.5    Wilson, S.R.6
  • 83
    • 34447545690 scopus 로고    scopus 로고
    • The fundamental aspects and applications of Agilent HPLC-Chip
    • Yin H., Killeen K. The fundamental aspects and applications of Agilent HPLC-Chip. J. Sep. Sci. 2007, 30:1427-1434. 10.1002/jssc.200600454.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1427-1434
    • Yin, H.1    Killeen, K.2
  • 84
    • 34547527538 scopus 로고    scopus 로고
    • Recent applications in nanoliquid chromatography
    • Hernández-Borges J., Aturki Z., Rocco A., Fanali S. Recent applications in nanoliquid chromatography. J. Sep. Sci. 2007, 30:1589-1610. 10.1002/jssc.200700061.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1589-1610
    • Hernández-Borges, J.1    Aturki, Z.2    Rocco, A.3    Fanali, S.4
  • 85
    • 0141989835 scopus 로고    scopus 로고
    • On-chip chromatography: the last twenty years
    • de Mello A. On-chip chromatography: the last twenty years. Lab Chip 2002, 2:48N-54N. 10.1039/b207266c.
    • (2002) Lab Chip , vol.2 , pp. 48N-54N
    • de Mello, A.1
  • 86
    • 57749100967 scopus 로고    scopus 로고
    • Packing density, permeability, and separation efficiency of packed microchips at different particle-aspect ratios
    • Jung S., Ehlert S., Mora J.A., Kraiczek K., Dittmann M., Rozing G.P., et al. Packing density, permeability, and separation efficiency of packed microchips at different particle-aspect ratios. J. Chromatogr. A 2009, 1216:264-273. 10.1016/j.chroma.2008.11.073.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 264-273
    • Jung, S.1    Ehlert, S.2    Mora, J.A.3    Kraiczek, K.4    Dittmann, M.5    Rozing, G.P.6
  • 87
    • 12244255362 scopus 로고    scopus 로고
    • Microfluidic chip for peptide analysis with an integrated HPLC column, sample enrichment column, and nanoelectrospray tip
    • Yin H., Killeen K., Brennen R., Sobek D., Werlich M., Van De Goor T. Microfluidic chip for peptide analysis with an integrated HPLC column, sample enrichment column, and nanoelectrospray tip. Anal. Chem. 2005, 77:527-533. 10.1021/ac049068d.
    • (2005) Anal. Chem. , vol.77 , pp. 527-533
    • Yin, H.1    Killeen, K.2    Brennen, R.3    Sobek, D.4    Werlich, M.5    Van De Goor, T.6
  • 88
    • 15444380450 scopus 로고    scopus 로고
    • Integrated microfluidic device for mass spectrometry-based proteomics and its application to biomarker discovery programs
    • Fortier M.H., Bonneil E., Goodley P., Thibault P. Integrated microfluidic device for mass spectrometry-based proteomics and its application to biomarker discovery programs. Anal. Chem. 2005, 77:1631-1640. 10.1021/ac048506d.
    • (2005) Anal. Chem. , vol.77 , pp. 1631-1640
    • Fortier, M.H.1    Bonneil, E.2    Goodley, P.3    Thibault, P.4
  • 89
    • 37249014389 scopus 로고    scopus 로고
    • Microfluidic gradient formation for nanoflow chip LC
    • Brennen R.A., Yin H., Killeen K.P. Microfluidic gradient formation for nanoflow chip LC. Anal. Chem. 2007, 79:9302-9309. 10.1021/ac0712805.
    • (2007) Anal. Chem. , vol.79 , pp. 9302-9309
    • Brennen, R.A.1    Yin, H.2    Killeen, K.P.3
  • 90
    • 84921034004 scopus 로고    scopus 로고
    • Proteomic analysis of individual fruit fly hemolymph
    • Zeng Q., Smith D., Shippy S.A. Proteomic analysis of individual fruit fly hemolymph. J. Chromatogr. B 2014, 981-982:33-39. 10.1016/j.jchromb.2014.11.027.
    • (2014) J. Chromatogr. B , pp. 33-39
    • Zeng, Q.1    Smith, D.2    Shippy, S.A.3
  • 91
    • 70450207070 scopus 로고    scopus 로고
    • Microfluidic HPLC-chip devices with integral channels containing methylstyrenic-based monolithic media
    • Robotti K.M., Yin H., Brennen R., Trojer L., Killeen K. Microfluidic HPLC-chip devices with integral channels containing methylstyrenic-based monolithic media. J. Sep. Sci. 2009, 32:3379-3387. 10.1002/jssc.200900379.
    • (2009) J. Sep. Sci. , vol.32 , pp. 3379-3387
    • Robotti, K.M.1    Yin, H.2    Brennen, R.3    Trojer, L.4    Killeen, K.5
  • 92
    • 84869398333 scopus 로고    scopus 로고
    • Fast and efficient online release of N-glycans from glycoproteins facilitating liquid chromatography-tandem mass spectrometry glycomic profiling
    • Jmeian Y., Hammad L.A., Mechref Y. Fast and efficient online release of N-glycans from glycoproteins facilitating liquid chromatography-tandem mass spectrometry glycomic profiling. Anal. Chem. 2012, 84:8790-8796.
    • (2012) Anal. Chem. , vol.84 , pp. 8790-8796
    • Jmeian, Y.1    Hammad, L.A.2    Mechref, Y.3
  • 93
    • 0001652992 scopus 로고
    • Conditions affecting the sequence of organic compounds in Tswett adsorption columns
    • Strain H.H. Conditions affecting the sequence of organic compounds in Tswett adsorption columns. Ind. Eng. Chem. 1946, 18:605-609. 10.1021/i560158a006.
    • (1946) Ind. Eng. Chem. , vol.18 , pp. 605-609
    • Strain, H.H.1
  • 94
    • 0013881073 scopus 로고
    • Temperaturprogrammierung bei der adsorptionschromatographie von losungen
    • Hesse G., Engelhardt H. Temperaturprogrammierung bei der adsorptionschromatographie von losungen. J. Chromatogr. 1966, 21:228-238. 10.1016/S0021-9673(01)91296-8.
    • (1966) J. Chromatogr. , vol.21 , pp. 228-238
    • Hesse, G.1    Engelhardt, H.2
  • 95
    • 84983869171 scopus 로고
    • Role of column temperature in micro high performance liquid chromatography
    • Takeuchi T., Watanabe Y., Ishii D. Role of column temperature in micro high performance liquid chromatography. J. High Resolut. Chromatogr. 1981, 4:300-302. 10.1002/jhrc.1240040614.
    • (1981) J. High Resolut. Chromatogr. , vol.4 , pp. 300-302
    • Takeuchi, T.1    Watanabe, Y.2    Ishii, D.3
  • 96
    • 0001668304 scopus 로고
    • Temperature-programmed reversed-phase liquid chromatography with packed fused-silica columns
    • Hirata Y., Sumiya E. Temperature-programmed reversed-phase liquid chromatography with packed fused-silica columns. J. Chromatogr. 1983, 267:125-131. 10.1016/S0021-9673(01)93643-X.
    • (1983) J. Chromatogr. , vol.267 , pp. 125-131
    • Hirata, Y.1    Sumiya, E.2
  • 97
    • 0001388003 scopus 로고
    • Microbore high-performance liquid chromatographic columns: speed, efficiency, sensitivity and temperature programming
    • Bowermaster J., McNair H. Microbore high-performance liquid chromatographic columns: speed, efficiency, sensitivity and temperature programming. J. Chromatogr. 1983, 279:431-438. 10.1016/S0021-9673(01)93643-X.
    • (1983) J. Chromatogr. , vol.279 , pp. 431-438
    • Bowermaster, J.1    McNair, H.2
  • 98
    • 84986461870 scopus 로고
    • Microbore HPLC column performance and temperature programming capabilities
    • McNair H., Bowermaster J. Microbore HPLC column performance and temperature programming capabilities. J. High Resolut. Chromatogr. 1987, 10:27-31. 10.1002/jhrc.1240100106.
    • (1987) J. High Resolut. Chromatogr. , vol.10 , pp. 27-31
    • McNair, H.1    Bowermaster, J.2
  • 99
    • 0007869297 scopus 로고
    • Temperature-controlled high-speed microcolumn liquid chromatography
    • Jinno K. Temperature-controlled high-speed microcolumn liquid chromatography. Anal. Chem. 1985, 57:574-576. 10.1021/ac50001a059.
    • (1985) Anal. Chem. , vol.57 , pp. 574-576
    • Jinno, K.1
  • 100
    • 0002341792 scopus 로고
    • Adsorption effects in the chromatography of polymers
    • Skvortsov A.M., Gorvunov A.A. Adsorption effects in the chromatography of polymers. J. Chromatogr. 1986, 358:77-83. 10.1016/S0021-9673(01)90317-6.
    • (1986) J. Chromatogr. , vol.358 , pp. 77-83
    • Skvortsov, A.M.1    Gorvunov, A.A.2
  • 101
    • 0035686524 scopus 로고    scopus 로고
    • Temperature programming in liquid chromatography
    • Greibrokk T., Andersen T. Temperature programming in liquid chromatography. J. Sep. Sci. 2001, 24:899-909. 10.1002/1615-9314(20011201)24:12<899::AID-JSSC899>3.0.CO;2-K.
    • (2001) J. Sep. Sci. , vol.24 , pp. 899-909
    • Greibrokk, T.1    Andersen, T.2
  • 102
    • 0043195886 scopus 로고    scopus 로고
    • Novel column oven concept for cold spot large volume sample enrichment in high throughput temperature gradient capillary liquid chromatography
    • Holm A., Molander P., Lundanes E., Greibrokk T. Novel column oven concept for cold spot large volume sample enrichment in high throughput temperature gradient capillary liquid chromatography. J. Sep. Sci. 2003, 26:1147-1153. 10.1002/jssc.200301500.
    • (2003) J. Sep. Sci. , vol.26 , pp. 1147-1153
    • Holm, A.1    Molander, P.2    Lundanes, E.3    Greibrokk, T.4
  • 103
    • 37548998569 scopus 로고    scopus 로고
    • High temperature and temperature programmed HPLC: possibilities and limitations
    • Vanhoenacker G., Sandra P. High temperature and temperature programmed HPLC: possibilities and limitations. Anal. Bioanal. Chem. 2008, 390:245-248. 10.1007/s00216-007-1671-7.
    • (2008) Anal. Bioanal. Chem. , vol.390 , pp. 245-248
    • Vanhoenacker, G.1    Sandra, P.2
  • 104
    • 20444471554 scopus 로고    scopus 로고
    • Optimization of the coupling of high-temperature liquid chromatography and flame ionization detection: Application to the separations of alcohols
    • Guillarme D., Heinisch S., Gauvrit J.Y., Lanteri P., Rocca J.L. Optimization of the coupling of high-temperature liquid chromatography and flame ionization detection: Application to the separations of alcohols. J. Chromatogr. A 2005, 1078:22-27. 10.1016/j.chroma.2005.04.092.
    • (2005) J. Chromatogr. A , vol.1078 , pp. 22-27
    • Guillarme, D.1    Heinisch, S.2    Gauvrit, J.Y.3    Lanteri, P.4    Rocca, J.L.5
  • 105
    • 0030729597 scopus 로고    scopus 로고
    • Superheated water as an eluent for reversed-phase high-performance liquid chromatography
    • Smith R.M., Burgess R.J. Superheated water as an eluent for reversed-phase high-performance liquid chromatography. J. Chromatogr. A 1997, 785:49-55. 10.1016/S0021-9673(97)00570-0.
    • (1997) J. Chromatogr. A , vol.785 , pp. 49-55
    • Smith, R.M.1    Burgess, R.J.2
  • 106
    • 7444266289 scopus 로고    scopus 로고
    • Superheated water chromatography-nuclear magnetic resonance spectroscopy and mass spectrometry of vitamins
    • Chienthavorn O., Smith R.M., Saha S., Wilson I.D., Wright B., Taylor S.D., et al. Superheated water chromatography-nuclear magnetic resonance spectroscopy and mass spectrometry of vitamins. J. Pharm. Biomed. Anal. 2004, 36:477-482. 10.1016/j.jpba.2004.07.023.
    • (2004) J. Pharm. Biomed. Anal. , vol.36 , pp. 477-482
    • Chienthavorn, O.1    Smith, R.M.2    Saha, S.3    Wilson, I.D.4    Wright, B.5    Taylor, S.D.6
  • 107
    • 33646007704 scopus 로고    scopus 로고
    • Development and application of a specially designed heating system for temperature-programmed high-performance liquid chromatography using subcritical water as the mobile phase
    • Teutenberg T., Goetze H.J., Tuerk J., Ploeger J., Kiffmeyer T.K., Schmidt K.G., et al. Development and application of a specially designed heating system for temperature-programmed high-performance liquid chromatography using subcritical water as the mobile phase. J. Chromatogr. A 2006, 1114:89-96. http://www.sciencedirect.com/science/article/B6TG8-4JFHF5H-2/2/3810d090835d5b7da715ea2c6369e133.
    • (2006) J. Chromatogr. A , vol.1114 , pp. 89-96
    • Teutenberg, T.1    Goetze, H.J.2    Tuerk, J.3    Ploeger, J.4    Kiffmeyer, T.K.5    Schmidt, K.G.6
  • 108
    • 0035325611 scopus 로고    scopus 로고
    • Evaluation of temperature programming for gradient elution in packed capillary liquid chromatography coupled to electrochemical detection
    • Nordström O., Molander P., Greibrokk T., Blomhoff R., Lundanes E. Evaluation of temperature programming for gradient elution in packed capillary liquid chromatography coupled to electrochemical detection. J. Microcolumn Sep. 2001, 13:179-185. 10.1002/mcs.1039.
    • (2001) J. Microcolumn Sep. , vol.13 , pp. 179-185
    • Nordström, O.1    Molander, P.2    Greibrokk, T.3    Blomhoff, R.4    Lundanes, E.5
  • 109
    • 0021406921 scopus 로고
    • Temperature programmed microbore HPLC - Part I
    • Bowermaster J., McNair H.M. Temperature programmed microbore HPLC - Part I. J. Chromatogr. Sci. 1984, 22:165-170. 10.1093/chromsci/22.4.165.
    • (1984) J. Chromatogr. Sci. , vol.22 , pp. 165-170
    • Bowermaster, J.1    McNair, H.M.2
  • 110
    • 0031567697 scopus 로고    scopus 로고
    • Temperature programming and gradient elution in reversed-phase chromatography with packed capillary columns
    • Michelle Hong C., Horváth C. Temperature programming and gradient elution in reversed-phase chromatography with packed capillary columns. J. Chromatogr. A 1997, 788:51-61. 10.1016/S0021-9673(97)00715-2.
    • (1997) J. Chromatogr. A , vol.788 , pp. 51-61
    • Michelle Hong, C.1    Horváth, C.2
  • 111
    • 58149105278 scopus 로고    scopus 로고
    • Sense and nonsense of high-temperature liquid chromatography
    • Heinisch S., Rocca J.-L. Sense and nonsense of high-temperature liquid chromatography. J. Chromatogr. A 2009, 1216:642-658. 10.1016/j.chroma.2008.11.079.
    • (2009) J. Chromatogr. A , vol.1216 , pp. 642-658
    • Heinisch, S.1    Rocca, J.-L.2
  • 112
    • 4744367342 scopus 로고    scopus 로고
    • Effect of temperature in reversed phase liquid chromatography
    • Guillarme D., Heinisch S., Rocca J.L. Effect of temperature in reversed phase liquid chromatography. J. Chromatogr. A 2004, 1052:39-51. 10.1016/j.chroma.2004.08.052.
    • (2004) J. Chromatogr. A , vol.1052 , pp. 39-51
    • Guillarme, D.1    Heinisch, S.2    Rocca, J.L.3
  • 113
    • 65549153130 scopus 로고    scopus 로고
    • Potential of high temperature liquid chromatography for the improvement of separation efficiency - a review
    • Teutenberg T. Potential of high temperature liquid chromatography for the improvement of separation efficiency - a review. Anal. Chim. Acta 2009, 643:1-12. 10.1016/j.aca.2009.04.008.
    • (2009) Anal. Chim. Acta , vol.643 , pp. 1-12
    • Teutenberg, T.1
  • 114
    • 2342597135 scopus 로고    scopus 로고
    • Temperature programmed liquid chromatography
    • Jones B.A. Temperature programmed liquid chromatography. J. Liq. Chromatogr. Relat. Technol. 2005, 27:1331-1352. 10.1081/JLC-120030605.
    • (2005) J. Liq. Chromatogr. Relat. Technol. , vol.27 , pp. 1331-1352
    • Jones, B.A.1
  • 115
    • 34547504080 scopus 로고    scopus 로고
    • Practice and theory of high temperature liquid chromatography
    • McNeff C.V., Yan B., Stoll D.R., Henry R.A. Practice and theory of high temperature liquid chromatography. J. Sep. Sci. 2007, 30:1672-1685. 10.1002/jssc.200600526.
    • (2007) J. Sep. Sci. , vol.30 , pp. 1672-1685
    • McNeff, C.V.1    Yan, B.2    Stoll, D.R.3    Henry, R.A.4
  • 116
    • 84960548419 scopus 로고    scopus 로고
    • (accessed 13.06.15).
    • ZirChrom Separations, 2015. Available at: (accessed 13.06.15). https://www.zirchrom.com/.
    • (2015)
  • 117
    • 84960548420 scopus 로고    scopus 로고
    • (accessed 14.06.15).
    • Timberline Instruments, 2015. Available at: (accessed 14.06.15). http://www.timberlineinstruments.com/.
    • (2015)
  • 118
    • 84960548421 scopus 로고    scopus 로고
    • (accessed 13.06.15).
    • Selerity Technologies, 2015. Available at: (accessed 13.06.15). http://www.selerity.com/.
    • (2015)
  • 119
    • 84960548422 scopus 로고    scopus 로고
    • (accessed 13.06.15).
    • Scientific Instruments Manufacturer GmbH, 2015. Available at: (accessed 13.06.15). http://sim-gmbh.de/en/.
    • (2015)
  • 120
    • 60649088702 scopus 로고    scopus 로고
    • High temperature liquid chromatography with monolithic capillary columns and pure water eluent
    • Causon T.J., Shellie R.A., Hilder E.F. High temperature liquid chromatography with monolithic capillary columns and pure water eluent. Analyst 2009, 134:440-442. 10.1039/B815886J.
    • (2009) Analyst , vol.134 , pp. 440-442
    • Causon, T.J.1    Shellie, R.A.2    Hilder, E.F.3
  • 121
    • 79957958919 scopus 로고    scopus 로고
    • Versatile capillary column temperature control using a thermoelectric array based platform
    • Collins D., Nesterenko E., Connolly D., Vasquez M., Macka M., Brabazon D., et al. Versatile capillary column temperature control using a thermoelectric array based platform. Anal. Chem. 2011, 83:4307-4313. 10.1021/ac2004955.
    • (2011) Anal. Chem. , vol.83 , pp. 4307-4313
    • Collins, D.1    Nesterenko, E.2    Connolly, D.3    Vasquez, M.4    Macka, M.5    Brabazon, D.6
  • 122
    • 59349100022 scopus 로고    scopus 로고
    • The influence of temperature and pressure factors in supercritical fluid extraction for optimizing nonpolar lipid extraction from buttermilk powder
    • Spence A.J., Jimenez-Flores R., Qian M., Goddik L. The influence of temperature and pressure factors in supercritical fluid extraction for optimizing nonpolar lipid extraction from buttermilk powder. J. Dairy Sci. 2009, 92:458-468. 10.3168/jds.2008-1278.
    • (2009) J. Dairy Sci. , vol.92 , pp. 458-468
    • Spence, A.J.1    Jimenez-Flores, R.2    Qian, M.3    Goddik, L.4
  • 123
    • 84922426332 scopus 로고    scopus 로고
    • LED-based UV absorption detector with low detection limits for capillary liquid chromatography
    • Sharma S., Tolley H.D., Farnsworth P.B., Lee M.L. LED-based UV absorption detector with low detection limits for capillary liquid chromatography. Anal. Chem. 2015, 87:1381-1386. 10.1021/ac504275m.
    • (2015) Anal. Chem. , vol.87 , pp. 1381-1386
    • Sharma, S.1    Tolley, H.D.2    Farnsworth, P.B.3    Lee, M.L.4
  • 124
    • 0022029557 scopus 로고
    • Electrospray interface for liquid chromatographs and mass spectrometers
    • Whitehouse C.M., Dreyer R.N., Yamashita M., Fenn J.B. Electrospray interface for liquid chromatographs and mass spectrometers. Anal. Chem. 1985, 57:675-679. 10.1021/ac00280a023.
    • (1985) Anal. Chem. , vol.57 , pp. 675-679
    • Whitehouse, C.M.1    Dreyer, R.N.2    Yamashita, M.3    Fenn, J.B.4
  • 125
    • 0032911015 scopus 로고    scopus 로고
    • Comparison of conventional, narrow-bore and capillary liquid chromatography/mass spectrometry for electrospray ionization mass spectrometry: practical considerations
    • Abian J., Oosterkamp A.J., Gelpí E. Comparison of conventional, narrow-bore and capillary liquid chromatography/mass spectrometry for electrospray ionization mass spectrometry: practical considerations. J. Mass Spectrom. 1999, 34:244-254. 10.1002/(SICI)1096-9888(199904)34:4<244::AID-JMS775>3.0.CO;2-0.
    • (1999) J. Mass Spectrom. , vol.34 , pp. 244-254
    • Abian, J.1    Oosterkamp, A.J.2    Gelpí, E.3
  • 126
    • 0029685702 scopus 로고    scopus 로고
    • Analytical properties of the nanoelectrospray ion source
    • Wilm M., Mann M. Analytical properties of the nanoelectrospray ion source. Anal. Chem. 1996, 68:1-8. 10.1021/ac9509519.
    • (1996) Anal. Chem. , vol.68 , pp. 1-8
    • Wilm, M.1    Mann, M.2
  • 127
    • 37749016457 scopus 로고    scopus 로고
    • Multiresidue determination of chlorophenoxy acid herbicides in human urine samples by use of solid-phase extraction and capillary LC-UV detection
    • Rosales-Conrado N., Leon-Gonzalez M.E., Perez-Arribas L.V., Polo-Diez L.M. Multiresidue determination of chlorophenoxy acid herbicides in human urine samples by use of solid-phase extraction and capillary LC-UV detection. Anal. Bioanal. Chem. 2008, 390:759-768. 10.1007/s00216-007-1701-5.
    • (2008) Anal. Bioanal. Chem. , vol.390 , pp. 759-768
    • Rosales-Conrado, N.1    Leon-Gonzalez, M.E.2    Perez-Arribas, L.V.3    Polo-Diez, L.M.4
  • 128
    • 58549118235 scopus 로고    scopus 로고
    • On-line solid phase extraction coupled to capillary LC-ESI-MS for determination of fluoxetine in human blood plasma
    • Saber A.L. On-line solid phase extraction coupled to capillary LC-ESI-MS for determination of fluoxetine in human blood plasma. Talanta 2009, 78:295-299. 10.1016/j.talanta.2008.11.016.
    • (2009) Talanta , vol.78 , pp. 295-299
    • Saber, A.L.1
  • 129
    • 33749254404 scopus 로고    scopus 로고
    • Capillary and nano-liquid chromatography-tandem mass spectrometry for the quantification of small molecules in microdialysis samples: Comparison with microbore dimensions
    • Lanckmans K., Van Eeckhaut A., Sarre S., Smolders I., Michotte Y. Capillary and nano-liquid chromatography-tandem mass spectrometry for the quantification of small molecules in microdialysis samples: Comparison with microbore dimensions. J. Chromatogr. A 2006, 1131:166-175. 10.1016/j.chroma.2006.07.090.
    • (2006) J. Chromatogr. A , vol.1131 , pp. 166-175
    • Lanckmans, K.1    Van Eeckhaut, A.2    Sarre, S.3    Smolders, I.4    Michotte, Y.5
  • 130
    • 14944385529 scopus 로고    scopus 로고
    • Operational options to reduce matrix effects in liquid chromatography-electrospray ionisation-mass spectrometry analysis of aqueous environmental samples
    • Kloepfer A., Quintana J.B., Reemtsma T. Operational options to reduce matrix effects in liquid chromatography-electrospray ionisation-mass spectrometry analysis of aqueous environmental samples. J. Chromatogr. A 2005, 1067:153-160. 10.1016/j.chroma.2004.11.101.
    • (2005) J. Chromatogr. A , vol.1067 , pp. 153-160
    • Kloepfer, A.1    Quintana, J.B.2    Reemtsma, T.3
  • 132
    • 0036111824 scopus 로고    scopus 로고
    • A simple approach for coupling liquid chromatography and electron ionization mass spectrometry
    • Cappiello A., Famiglini G., Mangani F., Palma P. A simple approach for coupling liquid chromatography and electron ionization mass spectrometry. J. Am. Soc. Mass Spectrom. 2002, 13:265-273. 10.1016/S1044-0305(01)00363-4.
    • (2002) J. Am. Soc. Mass Spectrom. , vol.13 , pp. 265-273
    • Cappiello, A.1    Famiglini, G.2    Mangani, F.3    Palma, P.4
  • 134
    • 34548034478 scopus 로고    scopus 로고
    • On-line 1D and 2D porous layer open tubular/LC-ESI-MS using 10-μm-i.d. poly(styrene-divinylbenzene) columns for ultrasensitive proteomic analysis
    • Luo Q., Yue G., Valaskovic G.A., Gu Y., Wu S., Karger B.L. On-line 1D and 2D porous layer open tubular/LC-ESI-MS using 10-μm-i.d. poly(styrene-divinylbenzene) columns for ultrasensitive proteomic analysis. Anal. Chem. 2007, 79:6174-6181. 10.1021/ac070583w.
    • (2007) Anal. Chem. , vol.79 , pp. 6174-6181
    • Luo, Q.1    Yue, G.2    Valaskovic, G.A.3    Gu, Y.4    Wu, S.5    Karger, B.L.6
  • 135
    • 8444247086 scopus 로고    scopus 로고
    • Accurate mass measurements for the confirmation of Sudan azo-dyes in hot chilli products by capillary liquid chromatography-electrospray tandem quadrupole orthogonal-acceleration time of flight mass spectrometry
    • Calbiani F., Careri M., Elviri L., Mangia a., Zagnoni I. Accurate mass measurements for the confirmation of Sudan azo-dyes in hot chilli products by capillary liquid chromatography-electrospray tandem quadrupole orthogonal-acceleration time of flight mass spectrometry. J. Chromatogr. A 2004, 1058:127-135. 10.1016/j.chroma.2004.08.159.
    • (2004) J. Chromatogr. A , vol.1058 , pp. 127-135
    • Calbiani, F.1    Careri, M.2    Elviri, L.3    Mangia, A.4    Zagnoni, I.5
  • 136
    • 84899434734 scopus 로고    scopus 로고
    • Salting-out assisted liquid-liquid extraction combined with capillary HPLC for the determination of sulfonylurea herbicides in environmental water and banana juice samples
    • Gure A., Lara F.J., Moreno-González D., Megersa N., del Olmo-Iruela M., García-Campaña A.M. Salting-out assisted liquid-liquid extraction combined with capillary HPLC for the determination of sulfonylurea herbicides in environmental water and banana juice samples. Talanta 2014, 127:51-58. 10.1016/j.talanta.2014.03.070.
    • (2014) Talanta , vol.127 , pp. 51-58
    • Gure, A.1    Lara, F.J.2    Moreno-González, D.3    Megersa, N.4    del Olmo-Iruela, M.5    García-Campaña, A.M.6
  • 137
    • 84939974580 scopus 로고    scopus 로고
    • A new approach using micro HPLC-MS/MS for multi-mycotoxin analysis in maize samples
    • Hickert S., Gerding J., Ncube E., Hübner F., Flett B., Cramer B., et al. A new approach using micro HPLC-MS/MS for multi-mycotoxin analysis in maize samples. Mycotoxin Res. 2015, 31:109-115. 10.1007/s12550-015-0221-y.
    • (2015) Mycotoxin Res. , vol.31 , pp. 109-115
    • Hickert, S.1    Gerding, J.2    Ncube, E.3    Hübner, F.4    Flett, B.5    Cramer, B.6
  • 138
    • 84937853383 scopus 로고    scopus 로고
    • Analysis of polar triazines and degradation products in waters by in-tube solid-phase microextraction and capillary chromatography: an environmentally friendly method
    • Moliner-Martínez Y., Serra-Mora P., Verdú-Andrés J., Herráez-Hernández R., Campíns-Falcó P. Analysis of polar triazines and degradation products in waters by in-tube solid-phase microextraction and capillary chromatography: an environmentally friendly method. Anal. Bioanal. Chem. 2014, 407:1485-1497. 10.1007/s00216-014-8366-7.
    • (2014) Anal. Bioanal. Chem. , vol.407 , pp. 1485-1497
    • Moliner-Martínez, Y.1    Serra-Mora, P.2    Verdú-Andrés, J.3    Herráez-Hernández, R.4    Campíns-Falcó, P.5
  • 140
    • 33744967253 scopus 로고    scopus 로고
    • Two-dimensional capillary liquid chromatography: pH gradient ion exchange and reversed phase chromatography for rapid separation of proteins
    • Pepaj M., Wilson S.R., Novotna K., Lundanes E., Greibrokk T. Two-dimensional capillary liquid chromatography: pH gradient ion exchange and reversed phase chromatography for rapid separation of proteins. J. Chromatogr. A 2006, 1120:132-141. 10.1016/j.chroma.2006.02.031.
    • (2006) J. Chromatogr. A , vol.1120 , pp. 132-141
    • Pepaj, M.1    Wilson, S.R.2    Novotna, K.3    Lundanes, E.4    Greibrokk, T.5
  • 141
    • 30744448972 scopus 로고    scopus 로고
    • Ultrahigh pressure liquid chromatography using elevated temperature
    • Xiang Y., Liu Y., Lee M.L. Ultrahigh pressure liquid chromatography using elevated temperature. J. Chromatogr. A 2006, 1104:198-202. 10.1016/j.chroma.2005.11.118.
    • (2006) J. Chromatogr. A , vol.1104 , pp. 198-202
    • Xiang, Y.1    Liu, Y.2    Lee, M.L.3
  • 142
    • 49549127818 scopus 로고
    • Studies of micro high-performance liquid chromatography: III. Development of a "micro-pre-column method" for pre-treatment of samples
    • Ishii D., Hibi K., Asai K., Nagaya M. Studies of micro high-performance liquid chromatography: III. Development of a "micro-pre-column method" for pre-treatment of samples. J. Chromatogr. 1978, 152:341-348. 10.1016/S0021-9673(00)85069-4.
    • (1978) J. Chromatogr. , vol.152 , pp. 341-348
    • Ishii, D.1    Hibi, K.2    Asai, K.3    Nagaya, M.4
  • 143
    • 0021928365 scopus 로고
    • Development of an on-line high-pressure pre-column concentration method for micro high-performance liquid chromatography and its application to the rapid determination of dibutyl phthalate in water
    • Takeuchi T., Jin Y., Ishii D. Development of an on-line high-pressure pre-column concentration method for micro high-performance liquid chromatography and its application to the rapid determination of dibutyl phthalate in water. J. Chromatogr. 1985, 321:159-164. 10.1016/S0021-9673(01)90432-7.
    • (1985) J. Chromatogr. , vol.321 , pp. 159-164
    • Takeuchi, T.1    Jin, Y.2    Ishii, D.3
  • 144
    • 33748898737 scopus 로고    scopus 로고
    • Microcolumn solid-phase extraction coupled online to capillary liquid chromatography using a valve switching technique
    • Tian H., Yang B., Guan W., Guan Y. Microcolumn solid-phase extraction coupled online to capillary liquid chromatography using a valve switching technique. Chin. J. Anal. Chem. 2006, 34:759-763. 10.1016/S1872-2040(06)60038-8.
    • (2006) Chin. J. Anal. Chem. , vol.34 , pp. 759-763
    • Tian, H.1    Yang, B.2    Guan, W.3    Guan, Y.4
  • 146
    • 84867097121 scopus 로고    scopus 로고
    • An overview of recent advances in HPLC instrumentation
    • Zotou A. An overview of recent advances in HPLC instrumentation. Cent. Eur. J. Chem 2012, 10:554-569. 10.2478/s11532-011-0161-0.
    • (2012) Cent. Eur. J. Chem , vol.10 , pp. 554-569
    • Zotou, A.1
  • 147
    • 84857047144 scopus 로고    scopus 로고
    • Selective comprehensive multi-dimensional separation for resolution enhancement in high performance liquid chromatography. Part I: Principles and instrumentation
    • Groskreutz S.R., Swenson M.M., Secor L.B., Stoll D.R. Selective comprehensive multi-dimensional separation for resolution enhancement in high performance liquid chromatography. Part I: Principles and instrumentation. J. Chromatogr. A 2012, 1228:31-40. 10.1016/j.chroma.2011.06.035.
    • (2012) J. Chromatogr. A , vol.1228 , pp. 31-40
    • Groskreutz, S.R.1    Swenson, M.M.2    Secor, L.B.3    Stoll, D.R.4
  • 148
    • 79953904552 scopus 로고    scopus 로고
    • Recent developments in the HPLC separation of phenolic compounds
    • Kalili K.M., de Villiers A. Recent developments in the HPLC separation of phenolic compounds. J. Sep. Sci. 2011, 34:854-876. 10.1002/jssc.201000811.
    • (2011) J. Sep. Sci. , vol.34 , pp. 854-876
    • Kalili, K.M.1    de Villiers, A.2
  • 149
    • 65249155472 scopus 로고    scopus 로고
    • Development and validation of an on-line two-dimensional reversed-phase liquid chromatography-tandem mass spectrometry method for the simultaneous determination of prostaglandins E2 and F2α and 13,14-dihydro-15-keto prostaglandin F2α levels in human plasma
    • Komaba J., Matsuda D., Shibakawa K., Nakade S., Hashimoto Y., Miyata Y., et al. Development and validation of an on-line two-dimensional reversed-phase liquid chromatography-tandem mass spectrometry method for the simultaneous determination of prostaglandins E2 and F2α and 13,14-dihydro-15-keto prostaglandin F2α levels in human plasma. Biomed. Chromatogr. 2009, 23:315-323. 10.1002/bmc.1117.
    • (2009) Biomed. Chromatogr. , vol.23 , pp. 315-323
    • Komaba, J.1    Matsuda, D.2    Shibakawa, K.3    Nakade, S.4    Hashimoto, Y.5    Miyata, Y.6
  • 150
    • 34848866572 scopus 로고    scopus 로고
    • 2D LC separation and determination of Bradykinin in rat muscle tissue dialysate with on-line SPE-HILIC-SPE-RP-MS
    • Wilson S.R., Jankowski M., Pepaj M., Mihailova A., Boix F., Vivo Truyols G., et al. 2D LC separation and determination of Bradykinin in rat muscle tissue dialysate with on-line SPE-HILIC-SPE-RP-MS. Chromatographia 2007, 66:469-474. 10.1365/s10337-007-0341-4.
    • (2007) Chromatographia , vol.66 , pp. 469-474
    • Wilson, S.R.1    Jankowski, M.2    Pepaj, M.3    Mihailova, A.4    Boix, F.5    Vivo Truyols, G.6
  • 151
    • 84875364692 scopus 로고    scopus 로고
    • Performance evaluation of thick film open tubular silica capillary by reversed phase liquid chromatography
    • Forster S., Kolmar H., Altmaier S. Performance evaluation of thick film open tubular silica capillary by reversed phase liquid chromatography. J. Chromatogr. A 2013, 1283:110-115. 10.1016/j.chroma.2013.01.107.
    • (2013) J. Chromatogr. A , vol.1283 , pp. 110-115
    • Forster, S.1    Kolmar, H.2    Altmaier, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.