-
1
-
-
84892649479
-
Standards of medical care in diabetes-2014
-
American Diabetes Association: Standards of medical care in diabetes-2014. Diabetes Care 2014;37(Suppl 1):S14-S80.
-
(2014)
Diabetes Care
, vol.37
, pp. S14-S80
-
-
American Diabetes Association1
-
2
-
-
57349104419
-
Self-monitoring of blood glucose (SMBG) in insulin- and non-insulin-using adults with diabetes: Consensus recommendations for improving SMBG accuracy, utilization, and research
-
Hirsch IB, Bode BW, Childs BP, Close KL, Fisher WA, Gavin JR, Ginsberg BH, Raine CH, Verderese CA: Self-monitoring of blood glucose (SMBG) in insulin- and non-insulin-using adults with diabetes: consensus recommendations for improving SMBG accuracy, utilization, and research. Diabetes Technol Ther 2008;10:419-439.
-
(2008)
Diabetes Technol Ther
, vol.10
, pp. 419-439
-
-
Hirsch, I.B.1
Bode, B.W.2
Childs, B.P.3
Close, K.L.4
Fisher, W.A.5
Gavin, J.R.6
Ginsberg, B.H.7
Raine, C.H.8
Verderese, C.A.9
-
3
-
-
0034939686
-
Self-monitoring of blood glucose levels and glycemic control: The Northern California Kaiser Permanente Diabetes Registry
-
Karter AJ, Ackerson LM, Darbinian JA, D'Agostino RB Jr, Ferrara A, Liu J, Selby JV: Self-monitoring of blood glucose levels and glycemic control: the Northern California Kaiser Permanente Diabetes Registry. Am J Med 2001;111: 1-9.
-
(2001)
Am J Med
, vol.111
, pp. 1-9
-
-
Karter, A.J.1
Ackerson, L.M.2
Darbinian, J.A.3
D'Agostino, R.B.4
Ferrara, A.5
Liu, J.6
Selby, J.V.7
-
4
-
-
0027370108
-
The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
-
The Diabetes Control and Complications Trial Research Group: The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med 1993; 329:977-986.
-
(1993)
N Engl J Med
, vol.329
, pp. 977-986
-
-
-
5
-
-
84891446217
-
Clinical implications and economic impact of accuracy differences among commercially available blood glucose monitoring systems
-
Budiman ES, Samant N, Resch A: Clinical implications and economic impact of accuracy differences among commercially available blood glucose monitoring systems. J Diabetes Sci Technol 2013;7:365-380.
-
(2013)
J Diabetes Sci Technol
, vol.7
, pp. 365-380
-
-
Budiman, E.S.1
Samant, N.2
Resch, A.3
-
6
-
-
84858133080
-
Glucose meter inaccuracy and the impact on the care of patients
-
Hellman R: Glucose meter inaccuracy and the impact on the care of patients. Diabetes Metab Res Rev 2012;28:207-209.
-
(2012)
Diabetes Metab Res Rev
, vol.28
, pp. 207-209
-
-
Hellman, R.1
-
9
-
-
84930749375
-
Accuracy evaluation of blood glucose monitoring systems in children on overnight closed-loop control
-
DeSalvo DJ, Shanmugham S, Ly TT, Wilson DM, Buckingham BA: Accuracy evaluation of blood glucose monitoring systems in children on overnight closed-loop control. J Diabetes Sci Technol 2014;8:969-973.
-
(2014)
J Diabetes Sci Technol
, vol.8
, pp. 969-973
-
-
DeSalvo, D.J.1
Shanmugham, S.2
Ly, T.T.3
Wilson, D.M.4
Buckingham, B.A.5
-
10
-
-
84920860821
-
Accuracy evaluation of Contour Next compared with five blood glucose monitoring systems across a wide range of blood glucose concentrations occurring in a clinical research setting
-
Klaff LJ, Brazg R, Hughes K, Tideman AM, Schachner HC, Stenger P, Pardo S, Dunne N, Parkes JL: Accuracy evaluation of Contour Next compared with five blood glucose monitoring systems across a wide range of blood glucose concentrations occurring in a clinical research setting. Diabetes Technol Ther 2015;17:8-15.
-
(2015)
Diabetes Technol Ther
, vol.17
, pp. 8-15
-
-
Klaff, L.J.1
Brazg, R.2
Hughes, K.3
Tideman, A.M.4
Schachner, H.C.5
Stenger, P.6
Pardo, S.7
Dunne, N.8
Parkes, J.L.9
-
11
-
-
84900550638
-
Accuracy evaluation of five blood glucose monitoring systems: The North American comparator trial
-
Halldorsdottir S, Warchal-Windham ME, Wallace JF, Pardo S, Parkes JL, Simmons DA: Accuracy evaluation of five blood glucose monitoring systems: the North American comparator trial. J Diabetes Sci Technol 2013;7:1294-1304.
-
(2013)
J Diabetes Sci Technol
, vol.7
, pp. 1294-1304
-
-
Halldorsdottir, S.1
Warchal-Windham, M.E.2
Wallace, J.F.3
Pardo, S.4
Parkes, J.L.5
Simmons, D.A.6
-
12
-
-
84859716063
-
Clinical assessment of the accuracy of blood glucose measurement devices
-
Pfützner A, Mitri M, Musholt PB, Sachsenheimer D, Borchert M, Yap A, Forst T: Clinical assessment of the accuracy of blood glucose measurement devices. Curr Med Res Opin 2012;28:525-531.
-
(2012)
Curr Med Res Opin
, vol.28
, pp. 525-531
-
-
Pfützner, A.1
Mitri, M.2
Musholt, P.B.3
Sachsenheimer, D.4
Borchert, M.5
Yap, A.6
Forst, T.7
-
13
-
-
84859313151
-
Accuracy evaluation of five blood glucose monitoring systems obtained from the pharmacy: A European multicenter study with 453 subjects
-
Tack C, Pohlmeier H, Behnke T, Schmid V, Grenningloh M, Forst T, Pfützner A: Accuracy evaluation of five blood glucose monitoring systems obtained from the pharmacy: a European multicenter study with 453 subjects. Diabetes Technol Ther 2012;14:1-8.
-
(2012)
Diabetes Technol Ther
, vol.14
, pp. 1-8
-
-
Tack, C.1
Pohlmeier, H.2
Behnke, T.3
Schmid, V.4
Grenningloh, M.5
Forst, T.6
Pfützner, A.7
-
14
-
-
84864535171
-
Assessment of three frequently used blood glucose monitoring devices in clinical routine
-
Zueger T, Schuler V, Stettler C, Diem P, Christ E: Assessment of three frequently used blood glucose monitoring devices in clinical routine. Swiss Med Wkly 2012;142: w13631.
-
(2012)
Swiss Med Wkly
, vol.142
-
-
Zueger, T.1
Schuler, V.2
Stettler, C.3
Diem, P.4
Christ, E.5
-
15
-
-
84899087565
-
Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor
-
Bailey TS, Ahmann A, Brazg R, Christiansen M, Garg S, Watkins E, Welsh JB, Lee SW: Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor. Diabetes Technol Ther 2014;16:277-283.
-
(2014)
Diabetes Technol Ther
, vol.16
, pp. 277-283
-
-
Bailey, T.S.1
Ahmann, A.2
Brazg, R.3
Christiansen, M.4
Garg, S.5
Watkins, E.6
Welsh, J.B.7
Lee, S.W.8
-
16
-
-
84905901716
-
A comparative effectiveness analysis of three continuous glucose monitors: The Navigator, G4 Platinum, and Enlite
-
Damiano ER, McKeon K, El-Khatib FH, Zheng H, Nathan DM, Russell SJ: A comparative effectiveness analysis of three continuous glucose monitors: the Navigator, G4 Platinum, and Enlite. J Diabetes Sci Technol 2014;8:699-708.
-
(2014)
J Diabetes Sci Technol
, vol.8
, pp. 699-708
-
-
Damiano, E.R.1
McKeon, K.2
El-Khatib, F.H.3
Zheng, H.4
Nathan, D.M.5
Russell, S.J.6
-
17
-
-
84889635916
-
Performance evaluation of three continuous glucose monitoring systems: Comparison of six sensors per subject in parallel
-
Freckmann G, Pleus S, Link M, Zschornack E, Klotzer HM, Haug C: Performance evaluation of three continuous glucose monitoring systems: comparison of six sensors per subject in parallel. J Diabetes Sci Technol 2013;7:842-853.
-
(2013)
J Diabetes Sci Technol
, vol.7
, pp. 842-853
-
-
Freckmann, G.1
Pleus, S.2
Link, M.3
Zschornack, E.4
Klotzer, H.M.5
Haug, C.6
-
18
-
-
84898461270
-
Continuous glucose monitoring in the subcutaneous tissue over a 14- day sensor wear period
-
Hoss U, Budiman ES, Liu H, Christiansen MP: Continuous glucose monitoring in the subcutaneous tissue over a 14- day sensor wear period. J Diabetes Sci Technol 2013;7: 1210-1219.
-
(2013)
J Diabetes Sci Technol
, vol.7
, pp. 1210-1219
-
-
Hoss, U.1
Budiman, E.S.2
Liu, H.3
Christiansen, M.P.4
-
19
-
-
84861879435
-
Hypoglycemia, diabetes, and cardiovascular disease
-
Snell-Bergeon JK, Wadwa RP: Hypoglycemia, diabetes, and cardiovascular disease. Diabetes Technol Ther 2012; 14(Suppl 1):S-51-S-58.
-
(2012)
Diabetes Technol Ther
, vol.14
, pp. S51-S58
-
-
Snell-Bergeon, J.K.1
Wadwa, R.P.2
-
20
-
-
79955468734
-
Recurrent hypoglycemia exacerbates cerebral ischemic damage in streptozotocin-induced diabetic rats
-
Dave KR, Tamariz J, Desai KM, Brand FJ, Liu A, Saul I, Bhattacharya SK, Pileggi A: Recurrent hypoglycemia exacerbates cerebral ischemic damage in streptozotocin-induced diabetic rats. Stroke 2011;42:1404-1411.
-
(2011)
Stroke
, vol.42
, pp. 1404-1411
-
-
Dave, K.R.1
Tamariz, J.2
Desai, K.M.3
Brand, F.J.4
Liu, A.5
Saul, I.6
Bhattacharya, S.K.7
Pileggi, A.8
-
21
-
-
80053569972
-
Acute hypoglycemia decreases myocardial blood flow reserve in patients with type 1 diabetes mellitus and in healthy humans
-
Rana O, Byrne CD, Kerr D, Coppini DV, Zouwail S, Senior R, Begley J, Walker JJ, Greaves K: Acute hypoglycemia decreases myocardial blood flow reserve in patients with type 1 diabetes mellitus and in healthy humans. Circulation 2011;124:1548-1556.
-
(2011)
Circulation
, vol.124
, pp. 1548-1556
-
-
Rana, O.1
Byrne, C.D.2
Kerr, D.3
Coppini, D.V.4
Zouwail, S.5
Senior, R.6
Begley, J.7
Walker, J.J.8
Greaves, K.9
-
22
-
-
77957933451
-
Effects of acute insulin-induced hypoglycemia on indices of inflammation: Putative mechanism for aggravating vascular disease in diabetes
-
Wright RJ, Newby DE, Stirling D, Ludlam CA, Macdonald IA, Frier BM: Effects of acute insulin-induced hypoglycemia on indices of inflammation: putative mechanism for aggravating vascular disease in diabetes. Diabetes Care 2010;33:1591-1597.
-
(2010)
Diabetes Care
, vol.33
, pp. 1591-1597
-
-
Wright, R.J.1
Newby, D.E.2
Stirling, D.3
Ludlam, C.A.4
Macdonald, I.A.5
Frier, B.M.6
-
23
-
-
39049148496
-
Effects of controlled hypoglycaemia on cardiac repolarisation in patients with type 1 diabetes
-
Koivikko ML, Karsikas M, Salmela PI, Tapanainen JS, Ruokonen A, Seppanen T, Huikuri HV, Perkiomaki JS: Effects of controlled hypoglycaemia on cardiac repolarisation in patients with type 1 diabetes. Diabetologia 2008; 51:426-435.
-
(2008)
Diabetologia
, vol.51
, pp. 426-435
-
-
Koivikko, M.L.1
Karsikas, M.2
Salmela, P.I.3
Tapanainen, J.S.4
Ruokonen, A.5
Seppanen, T.6
Huikuri, H.V.7
Perkiomaki, J.S.8
-
24
-
-
0028328828
-
Regional cerebral blood flow in IDDM patients: Effects of diabetes and of recurrent severe hypoglycaemia
-
MacLeod KM, Hepburn DA, Deary IJ, Goodwin GM, Dougall N, Ebmeier KP, Frier BM: Regional cerebral blood flow in IDDM patients: effects of diabetes and of recurrent severe hypoglycaemia. Diabetologia 1994;37:257-263.
-
(1994)
Diabetologia
, vol.37
, pp. 257-263
-
-
MacLeod, K.M.1
Hepburn, D.A.2
Deary, I.J.3
Goodwin, G.M.4
Dougall, N.5
Ebmeier, K.P.6
Frier, B.M.7
-
26
-
-
58549091951
-
Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen
-
Bundesärztekammer: Richtlinie der Bundesärztekammer zur Qualitätssicherung laboratoriumsmedizinischer Untersuchungen. Deutsch Ärzteblatt 2008;105:341-355.
-
(2008)
Deutsch Ärzteblatt
, vol.105
, pp. 341-355
-
-
Bundesärztekammer1
-
27
-
-
84900546033
-
Partial pressure of oxygen in capillary blood samples from the fingertip
-
Freckmann G, Schmid C, Baumstark A, Pleus S, Link M, Haug C: Partial pressure of oxygen in capillary blood samples from the fingertip. J Diabetes Sci Technol 2013;7: 1648-1649.
-
(2013)
J Diabetes Sci Technol
, vol.7
, pp. 1648-1649
-
-
Freckmann, G.1
Schmid, C.2
Baumstark, A.3
Pleus, S.4
Link, M.5
Haug, C.6
-
28
-
-
84905905480
-
The surveillance error grid
-
Klonoff D, Lias C, Vigersky R, Clarke W, Parkes JL, Sacks DB, Kirkman MS, Kovatchev B: The surveillance error grid. J Diabetes Sci Technol 2014;8:685-672.
-
(2014)
J Diabetes Sci Technol
, vol.8
, pp. 685-1672
-
-
Klonoff, D.1
Lias, C.2
Vigersky, R.3
Clarke, W.4
Parkes, J.L.5
Sacks, D.B.6
Kirkman, M.S.7
Kovatchev, B.8
-
29
-
-
84905923754
-
Computing the surveillance error grid analysis: Procedure and examples
-
Kovatchev BP, Wakeman CA, Breton MD, Kost GJ, Louie RF, Tran NK, Klonoff DC: Computing the surveillance error grid analysis: procedure and examples. J Diabetes Sci Technol 2014;8:673-684.
-
(2014)
J Diabetes Sci Technol
, vol.8
, pp. 673-684
-
-
Kovatchev, B.P.1
Wakeman, C.A.2
Breton, M.D.3
Kost, G.J.4
Louie, R.F.5
Tran, N.K.6
Klonoff, D.C.7
-
30
-
-
84884557685
-
System accuracy of blood glucose monitoring systems: Impact of use by patients and ambient conditions
-
Schmid C, Haug C, Heinemann L, Freckmann G: System accuracy of blood glucose monitoring systems: impact of use by patients and ambient conditions. Diabetes Technol Ther 2013;15:889-896.
-
(2013)
Diabetes Technol Ther
, vol.15
, pp. 889-896
-
-
Schmid, C.1
Haug, C.2
Heinemann, L.3
Freckmann, G.4
-
31
-
-
79956127259
-
Self-monitoring of blood glucose: The use of the first or the second drop of blood
-
Hortensius J, Slingerland RJ, Kleefstra N, Logtenberg SJ, Groenier KH, Houweling ST, Bilo HJ: Self-monitoring of blood glucose: the use of the first or the second drop of blood. Diabetes Care 2011;34:556-560.
-
(2011)
Diabetes Care
, vol.34
, pp. 556-560
-
-
Hortensius, J.1
Slingerland, R.J.2
Kleefstra, N.3
Logtenberg, S.J.4
Groenier, K.H.5
Houweling, S.T.6
Bilo, H.J.7
-
32
-
-
79956160504
-
Glucose monitoring after fruit peeling: Pseudohyperglycemia when neglecting hand washing before fingertip blood sampling: Wash your hands with tap water before you check blood glucose level
-
Hirose T, Mita T, Fujitani Y, Kawamori R, Watada H: Glucose monitoring after fruit peeling: pseudohyperglycemia when neglecting hand washing before fingertip blood sampling: wash your hands with tap water before you check blood glucose level. Diabetes Care 2011; 34:596-597.
-
(2011)
Diabetes Care
, vol.34
, pp. 596-597
-
-
Hirose, T.1
Mita, T.2
Fujitani, Y.3
Kawamori, R.4
Watada, H.5
-
33
-
-
70350209515
-
Factors affecting blood glucose monitoring: Sources of errors in measurement
-
Ginsberg BH: Factors affecting blood glucose monitoring: sources of errors in measurement. J Diabetes Sci Technol 2009;3:903-913.
-
(2009)
J Diabetes Sci Technol
, vol.3
, pp. 903-913
-
-
Ginsberg, B.H.1
-
34
-
-
57349106743
-
Standardized evaluation of nine instruments for self-monitoring of blood glucose
-
Kristensen GB, Monsen G, Skeie S, Sandberg S: Standardized evaluation of nine instruments for self-monitoring of blood glucose. Diabetes Technol Ther 2008;10:467-477.
-
(2008)
Diabetes Technol Ther
, vol.10
, pp. 467-477
-
-
Kristensen, G.B.1
Monsen, G.2
Skeie, S.3
Sandberg, S.4
-
35
-
-
85016650386
-
System accuracy evaluation of four systems for self-monitoring of blood glucose following ISO 15197 using a glucose oxidase and a hexokinase-based comparison method
-
April 14 [Epub ahead of print]. pii: 1932296815580161
-
Link M, Schmid C, Pleus S, Baumstark A, Rittmeyer D, Haug C, Freckmann G: System accuracy evaluation of four systems for self-monitoring of blood glucose following ISO 15197 using a glucose oxidase and a hexokinase-based comparison method. J Diabetes Sci Technol 2015 April 14 [Epub ahead of print]. pii: 1932296815580161.
-
(2015)
J Diabetes Sci Technol
-
-
Link, M.1
Schmid, C.2
Pleus, S.3
Baumstark, A.4
Rittmeyer, D.5
Haug, C.6
Freckmann, G.7
-
36
-
-
84875803673
-
Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197
-
Baumstark A, Pleus S, Schmid C, Link M, Haug C, Freckmann G: Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197. J Diabetes Sci Technol 2012;6:1076-1086.
-
(2012)
J Diabetes Sci Technol
, vol.6
, pp. 1076-1086
-
-
Baumstark, A.1
Pleus, S.2
Schmid, C.3
Link, M.4
Haug, C.5
Freckmann, G.6
-
37
-
-
24144435337
-
Between-lot variation in external quality assessment of glucose: Clinical importance and effect on participant performance evaluation
-
Kristensen GB, Christensen NG, Thue G, Sandberg S: Between-lot variation in external quality assessment of glucose: clinical importance and effect on participant performance evaluation. Clin Chem 2005;51:1632-1636.
-
(2005)
Clin Chem
, vol.51
, pp. 1632-1636
-
-
Kristensen, G.B.1
Christensen, N.G.2
Thue, G.3
Sandberg, S.4
|