Accuracy evaluation of blood glucose monitoring systems in children on overnight closed-loop control

Author keywords

Accuracy; Blood glucose; Blood glucose meter; Closed loop; Contour Next; HemoCue; YSI

Indexed keywords

GLUCOSE; HEMOGLOBIN A1C; INSULIN; GLUCOSE BLOOD LEVEL;

EID: 84930749375     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/1932296814532238     Document Type: Article
Times cited : (10)

References (14)
  • 1
    • 84884589359 scopus 로고    scopus 로고
    • Continuous glucose monitoring: Current use and future directions
    • DeSalvo D, Buckingham B. Continuous glucose monitoring: current use and future directions. Curr Diab Rep. 2013;13(5):657-662.
    • (2013) Curr Diab Rep , vol.13 , Issue.5 , pp. 657-662
    • DeSalvo, D.1    Buckingham, B.2
  • 2
    • 84868109034 scopus 로고    scopus 로고
    • Blood glucose control in type 1 diabetes with a bihormonal bionic endocrine pancreas
    • Russell SJ, El-Khatib FH, Nathan DM, et al. Blood glucose control in type 1 diabetes with a bihormonal bionic endocrine pancreas. Diabetes Care. 2012l35(11):2148-2155.
    • (2012) Diabetes Care , vol.135 , Issue.11 , pp. 2148-2155
    • Russell, S.J.1    El-Khatib, F.H.2    Nathan, D.M.3
  • 3
    • 84869081609 scopus 로고    scopus 로고
    • Inpatient studies of a Kalman-filter-based predictive pump shutoff algorithm
    • Cameron F, Wilson DM, Buckingham BA, et al. Inpatient studies of a Kalman-filter-based predictive pump shutoff algorithm. J Diabetes Sci Technol. 2012;6(5):1142-1147.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.5 , pp. 1142-1147
    • Cameron, F.1    Wilson, D.M.2    Buckingham, B.A.3
  • 4
    • 79960415279 scopus 로고    scopus 로고
    • A closed-loop artificial pancreas based on risk management
    • Cameron F, Bequette BW, Wilson DM, et al. A closed-loop artificial pancreas based on risk management. J Diabetes Sci Technol. 2011;5(2):368-379.
    • (2011) J Diabetes Sci Technol , vol.5 , Issue.2 , pp. 368-379
    • Cameron, F.1    Bequette, B.W.2    Wilson, D.M.3
  • 5
    • 84887279193 scopus 로고    scopus 로고
    • Blood glucose measurements in arterial blood of intensive care unit patients submitted to tight glycemic control: Agreement between bedside tests
    • Vlasselaers D, Van Herpe T, Milants I, et al. Blood glucose measurements in arterial blood of intensive care unit patients submitted to tight glycemic control: agreement between bedside tests. J Diabetes Sci Technol. 2008;2(6):932-938.
    • (2008) J Diabetes Sci Technol , vol.2 , Issue.6 , pp. 932-938
    • Vlasselaers, D.1    Van Herpe, T.2    Milants, I.3
  • 6
    • 0037756683 scopus 로고    scopus 로고
    • Comparison of pointof-care-Testing glucose meters with standard laboratory measurement of the 50g-glucose-challenge test (GCT) during pregnancy
    • Buhling KJ, Henrich W, Kjos SL, et al. Comparison of pointof-care-Testing glucose meters with standard laboratory measurement of the 50g-glucose-challenge test (GCT) during pregnancy. Clin Biochem. 2003;36(5):333-337.
    • (2003) Clin Biochem , vol.36 , Issue.5 , pp. 333-337
    • Buhling, K.J.1    Henrich, W.2    Kjos, S.L.3
  • 7
    • 0035724510 scopus 로고    scopus 로고
    • Accuracy of the hemocue portable glucose analyzer in a large nonhomogeneous population
    • Torjman MC, Jahn L, Joseph JI, Crothall K. Accuracy of the hemocue portable glucose analyzer in a large nonhomogeneous population. Diabetes Technol Ther. 2001;3(4):591-600.
    • (2001) Diabetes Technol Ther , vol.3 , Issue.4 , pp. 591-600
    • Torjman, M.C.1    Jahn, L.2    Joseph, J.I.3    Crothall, K.4
  • 8
    • 84900550638 scopus 로고    scopus 로고
    • Accuracy evaluation of five blood glucose monitoring systems: The North American Comparator Trial
    • Halldorsdottir S, Warchall-Windham ME, Wallace ME, et al. Accuracy evaluation of five blood glucose monitoring systems: the North American Comparator Trial. J Diabetes Sci Technol. 2013;7(5):1294-1304.
    • (2013) J Diabetes Sci Technol , vol.7 , Issue.5 , pp. 1294-1304
    • Halldorsdottir, S.1    Warchall-Windham, M.E.2    Wallace, M.E.3
  • 9
    • 84892649142 scopus 로고    scopus 로고
    • Evaluation of 12 blood glucose monitoring systems for self-Testing: System accuracy and measurement reproducibility
    • Freckmann G, Baumstark A, Schmid C, et al. Evaluation of 12 blood glucose monitoring systems for self-Testing: system accuracy and measurement reproducibility. Diabetes Technol Ther. 2014;16:113-122.
    • (2014) Diabetes Technol Ther , vol.16 , pp. 113-122
    • Freckmann, G.1    Baumstark, A.2    Schmid, C.3
  • 10
    • 84900534787 scopus 로고    scopus 로고
    • Analytical accuracy evaluation of the CONTOUR® XT blood glucose meter
    • A-107
    • Pflug B, Warchal-Windham ME, Goldy A, Chu A. Analytical accuracy evaluation of the CONTOUR® XT blood glucose meter. J Diabetes Sci Technol. 2013;7(1):281-284, A-107.
    • (2013) J Diabetes Sci Technol , vol.7 , Issue.1 , pp. 281-284
    • Pflug, B.1    Warchal-Windham, M.E.2    Goldy, A.3    Chu, A.4
  • 11
    • 84947982539 scopus 로고    scopus 로고
    • International Organization for Standardization. ISO 15197 vitro diagnostic test systems-requirements for bloodglucose monitoring systems for self-Testing in managing diabetes mellitus, May
    • International Organization for Standardization. ISO 15197. In vitro diagnostic test systems-requirements for bloodglucose monitoring systems for self-Testing in managing diabetes mellitus. May 2003.
    • (2003)
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 84880263474 scopus 로고    scopus 로고
    • Impact of prandial status on the comparison of capillary glucose meter and venous plasma glucose measurements in healthy volunteers
    • Swaminathan A, Lunt H, Chang WS, et al. Impact of prandial status on the comparison of capillary glucose meter and venous plasma glucose measurements in healthy volunteers. Ann Clin Biochem. 2013;50(pt 1):6-12.
    • (2013) Ann Clin Biochem , vol.50 , pp. 6-12
    • Swaminathan, A.1    Lunt, H.2    Chang, W.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.