메뉴 건너뛰기




Volumn 8, Issue 4, 2014, Pages 658-672

The surveillance error grid

Author keywords

Accuracy; Blood glucose; Error grid; Monitor; Surveillance

Indexed keywords

ANTIDIABETIC AGENT; GLUCOSE BLOOD LEVEL;

EID: 84905905480     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/1932296814539589     Document Type: Article
Times cited : (134)

References (20)
  • 1
    • 77951733801 scopus 로고    scopus 로고
    • A review of standards and statistics used to describe blood glucose monitor performance
    • Krouwer JS, Cembrowski GS. A review of standards and statistics used to describe blood glucose monitor performance. J Diabetes Sci Technol. 2010;4(1):75-83.
    • (2010) J Diabetes Sci Technol. , vol.4 , Issue.1 , pp. 75-83
    • Krouwer, J.S.1    Cembrowski, G.S.2
  • 2
    • 77954685027 scopus 로고    scopus 로고
    • Analytical and clinical performance of blood glucose monitors
    • Boren SA, Clarke WL. Analytical and clinical performance of blood glucose monitors. J Diabetes Sci Technol. 2010;4(1):84-97.
    • (2010) J Diabetes Sci Technol. , vol.4 , Issue.1 , pp. 84-97
    • Boren, S.A.1    Clarke, W.L.2
  • 3
    • 84863571079 scopus 로고    scopus 로고
    • The need for clinical accuracy guidelines for blood glucose monitors
    • Klonoff DC. The need for clinical accuracy guidelines for blood glucose monitors. J Diabetes Sci Technol 2012;6(1):1-4.
    • (2012) J Diabetes Sci Technol , vol.6 , Issue.1 , pp. 1-4
    • Klonoff, D.C.1
  • 6
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care. 1987;10(5):622-628.
    • (1987) Diabetes Care. , vol.10 , Issue.5 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 7
    • 0033855803 scopus 로고    scopus 로고
    • A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose
    • Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000;23:1143-1148.
    • (2000) Diabetes Care. , vol.23 , pp. 1143-1148
    • Parkes, J.L.1    Slatin, S.L.2    Pardo, S.3    Ginsberg, B.H.4
  • 8
    • 0027370108 scopus 로고
    • The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus
    • Diabetes Control and Complications Research Group.
    • Diabetes Control and Complications Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus. N Engl J Med. 1993;329:977-986.
    • (1993) N Engl J Med. , vol.329 , pp. 977-986
  • 9
    • 0030253870 scopus 로고    scopus 로고
    • Rapid-acting insulin approved for marketing
    • Rapid-acting insulin approved for marketing. Am J Health Syst Pharm. 1996;53(19):2250.
    • (1996) Am J Health Syst Pharm. , vol.53 , Issue.19 , pp. 2250
  • 10
    • 84885843485 scopus 로고    scopus 로고
    • Long-term outcome of insulin pump therapy in children with type 1 diabetes assessed in a large population-based case-control study
    • Johnson SR, Cooper MN, Jones TW, Davis EA. Long-term outcome of insulin pump therapy in children with type 1 diabetes assessed in a large population-based case-control study. Diabetologia. 2013;56:2392-2400.
    • (2013) Diabetologia. , vol.56 , pp. 2392-2400
    • Johnson, S.R.1    Cooper, M.N.2    Jones, T.W.3    Davis, E.A.4
  • 11
    • 78349287412 scopus 로고    scopus 로고
    • The Food and Drug Administration is now preparing to establish tighter performance requirements for blood glucose monitors
    • Klonoff DC. The Food and Drug Administration is now preparing to establish tighter performance requirements for blood glucose monitors. J Diabetes Sci Technol. 2010;4:499-504.
    • (2010) J Diabetes Sci Technol. , vol.4 , pp. 499-504
    • Klonoff, D.C.1
  • 12
    • 84876796916 scopus 로고    scopus 로고
    • Hypoglycemia and diabetes: A report of a workgroup of the American Diabetes Association and the Endocrine Society
    • doi:10.2337/dc12-2480
    • Seaquist ER, Anderson J, Childs B, et al. Hypoglycemia and diabetes: a report of a workgroup of the American Diabetes Association and the Endocrine Society. Diabetes Care. 2013;36(5):1384-1395. doi:10.2337/dc12-2480.
    • (2013) Diabetes Care. , vol.36 , Issue.5 , pp. 1384-1384
    • Seaquist, E.R.1    Anderson, J.2    Childs, B.3
  • 13
    • 84890165658 scopus 로고    scopus 로고
    • Selfreported non-severe hypoglycaemic events in Europe
    • Ostenson CG, Geelhoed-Duijvestijn P, Lahtela J, et al. Selfreported non-severe hypoglycaemic events in Europe. Diabetes Med. 2014;31(1):92-101.
    • (2014) Diabetes Med. , vol.31 , Issue.1 , pp. 92-101
    • Ostenson, C.G.1    Geelhoed-Duijvestijn, P.2    Lahtela, J.3
  • 14
    • 84875808323 scopus 로고    scopus 로고
    • Comparative analysis of the efficacy of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes mellitus
    • Floyd B, Chandra P, Hall S, et al. Comparative analysis of the efficacy of continuous glucose monitoring and self-monitoring of blood glucose in type 1 diabetes mellitus. J Diabetes Sci Technol. 2012;6(5):1094-1102.
    • (2012) J Diabetes Sci Technol. , vol.6 , Issue.5 , pp. 1094-1102
    • Floyd, B.1    Chandra, P.2    Hall, S.3
  • 15
    • 84859038969 scopus 로고    scopus 로고
    • Short-and long-term effects of real-time continuous glucose monitoring in patients with type 2 diabetes
    • Vigersky RA, Fonda SJ, Chellappa M, Walker MS, Ehrhardt NM. Short-and long-term effects of real-time continuous glucose monitoring in patients with type 2 diabetes. Diabetes Care. 2012;35(1):32-38.
    • (2012) Diabetes Care. , vol.35 , Issue.1 , pp. 32-38
    • Vigersky, R.A.1    Fonda, S.J.2    Chellappa, M.3    Walker, M.S.4    Ehrhardt, N.M.5
  • 16
    • 84875805117 scopus 로고    scopus 로고
    • System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN en ISO 15197
    • Freckmann G, Schmid C, Baumstark A, Pleus S, Link M, Haug C. System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197. J Diabetes Sci Technol. 2012;6(5):1060-1075.
    • (2012) J Diabetes Sci Technol. , vol.6 , Issue.5 , pp. 1060-1075
    • Freckmann, G.1    Schmid, C.2    Baumstark, A.3    Pleus, S.4    Link, M.5    Haug, C.6
  • 17
    • 84897122879 scopus 로고    scopus 로고
    • Do currently available blood glucose monitors meet regulatory standards? 1-day public meeting in Arlington, Virginia
    • Klonoff DC, Reyes J. Do currently available blood glucose monitors meet regulatory standards? 1-day public meeting in Arlington, Virginia. J Diabetes Sci Technol. 2013;7(4): 1071-1083.
    • (2013) J Diabetes Sci Technol. , vol.7 , Issue.4 , pp. 1071-1083
    • Klonoff, D.C.1    Reyes, J.2
  • 18
    • 0028116382 scopus 로고
    • Patient and physician analytic goals for self-monitoring blood glucose instruments
    • Weiss SL, Cembrowski GS, Mazze RS. Patient and physician analytic goals for self-monitoring blood glucose instruments. Am J Clin Pathol. 1994;102(5):611-615.
    • (1994) Am J Clin Pathol. , vol.102 , Issue.5 , pp. 611-615
    • Weiss, S.L.1    Cembrowski, G.S.2    Mazze, R.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.