메뉴 건너뛰기




Volumn 8, Issue 6, 2014, Pages 1081-1090

Point-of-care blood glucose testing for diabetes care in hospitalized patients: An evidence-based review

Author keywords

Blood glucose; Blood glucose meter; Diabetes; Hospital; Inpatients; Point of care

Indexed keywords

GLUCOSE; GLUCOSE BLOOD LEVEL;

EID: 84937892924     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/1932296814538940     Document Type: Review
Times cited : (75)

References (112)
  • 1
    • 84975856269 scopus 로고    scopus 로고
    • Economic costs of diabetes in the U.S. in 2012
    • American Diabetes Association.
    • American Diabetes Association. Economic costs of diabetes in the U.S. in 2012. Diabetes Care. 2013;36(4):1033-1046.
    • (2013) Diabetes Care. , vol.36 , Issue.4 , pp. 1033-1046
  • 4
    • 84872228501 scopus 로고    scopus 로고
    • Association between hypoglycemia and inpatient mortality and length of hospital stay in hospitalized, insulin-treated patients
    • Brodovicz KG, Mehta V, Zhang Q, et al. Association between hypoglycemia and inpatient mortality and length of hospital stay in hospitalized, insulin-treated patients. Curr Med Res Opin. 2013;29(2):101-107.
    • (2013) Curr Med Res Opin. , vol.29 , Issue.2 , pp. 101-107
    • Brodovicz, K.G.1    Mehta, V.2    Zhang, Q.3
  • 5
    • 84876815005 scopus 로고    scopus 로고
    • Hypoglycemia, with or without insulin therapy, is associated with increased mortality among hospitalized patients
    • Garg R, Hurwitz S, Turchin A, Trivedi A. Hypoglycemia, with or without insulin therapy, is associated with increased mortality among hospitalized patients. Diabetes Care. 2013;36(5):1107-1110.
    • (2013) Diabetes Care. , vol.36 , Issue.5 , pp. 1107-1110
    • Garg, R.1    Hurwitz, S.2    Turchin, A.3    Trivedi, A.4
  • 6
    • 0345374590 scopus 로고    scopus 로고
    • Association between hyperglycemia and increased hospital mortality in a heterogeneous population of critically ill patients
    • Krinsley JS. Association between hyperglycemia and increased hospital mortality in a heterogeneous population of critically ill patients. Mayo Clin Proc. 2003;78(12):1471-1478.
    • (2003) Mayo Clin Proc. , vol.78 , Issue.12 , pp. 1471-1478
    • Krinsley, J.S.1
  • 7
    • 84863634232 scopus 로고    scopus 로고
    • Mild hypoglycemia is strongly associated with increased intensive care unit length of stay
    • Krinsley J, Schultz MJ, Spronk PE, et al. Mild hypoglycemia is strongly associated with increased intensive care unit length of stay. Ann Intensive Care. 2011;1:49.
    • (2011) Ann Intensive Care. , vol.1 , pp. 49
    • Krinsley, J.1    Schultz, M.J.2    Spronk, P.E.3
  • 8
    • 79960605274 scopus 로고    scopus 로고
    • Mild hypoglycemia is independently associated with increased mortality in the critically ill
    • Krinsley JS, Schultz MJ, Spronk PE, et al. Mild hypoglycemia is independently associated with increased mortality in the critically ill. Crit Care. 2011;15(4):R173.
    • (2011) Crit Care. , vol.15 , Issue.4 , pp. R173
    • Krinsley, J.S.1    Schultz, M.J.2    Spronk, P.E.3
  • 9
    • 84869137330 scopus 로고    scopus 로고
    • Hypoglycaemia is associated with increased length of stay and mortality in people with diabetes who are hospitalized
    • Nirantharakumar K, Marshall T, Kennedy A, Narendran P, Hemming K, Coleman JJ. Hypoglycaemia is associated with increased length of stay and mortality in people with diabetes who are hospitalized. Diabetic Med. 2012;29(12):e445- 448.
    • (2012) Diabetic Med. , vol.29 , Issue.12 , pp. e445-e448
    • Nirantharakumar, K.1    Marshall, T.2    Kennedy, A.3    Narendran, P.4    Hemming, K.5    Coleman, J.J.6
  • 12
    • 0035829852 scopus 로고    scopus 로고
    • Intensive insulin therapy in critically ill patients
    • Van den Berghe G, Wouters P, Weekers F, et al. Intensive insulin therapy in critically ill patients. N Engl J Med. 2001;345(19):1359-1367.
    • (2001) N Engl J Med. , vol.345 , Issue.19 , pp. 1359-1367
    • Van Den Berghe, G.1    Wouters, P.2    Weekers, F.3
  • 13
    • 32044465949 scopus 로고    scopus 로고
    • Intensive insulin therapy in the medical ICU
    • Van den Berghe G, Wilmer A, Hermans G, et al. Intensive insulin therapy in the medical ICU. N Engl J Med. 2006;354(5):449-461.
    • (2006) N Engl J Med. , vol.354 , Issue.5 , pp. 449-461
    • Van Den Berghe, G.1    Wilmer, A.2    Hermans, G.3
  • 14
    • 40249120466 scopus 로고    scopus 로고
    • Standards of medical care in diabetes-2008
    • American Diabetes Association.
    • American Diabetes Association. Standards of medical care in diabetes-2008. Diabetes Care. 2008;31(suppl 1):S12-S54.
    • (2008) Diabetes Care. , vol.31 , pp. S12-S54
  • 15
    • 63249128249 scopus 로고    scopus 로고
    • Intensive versus conventional glucose control in critically ill patients
    • Finfer S, Chittock DR, Su SY, et al. Intensive versus conventional glucose control in critically ill patients. N Engl J Med. 2009;360(13):1283-1297.
    • (2009) N Engl J Med. , vol.360 , Issue.13 , pp. 1283-1297
    • Finfer, S.1    Chittock, D.R.2    Su, S.Y.3
  • 16
    • 50449103607 scopus 로고    scopus 로고
    • Benefits and risks of tight glucose control in critically ill adults: A meta-analysis
    • Wiener RS, Wiener DC, Larson RJ. Benefits and risks of tight glucose control in critically ill adults: a meta-analysis. JAMA. 2008;300(8):933-944.
    • (2008) JAMA. , vol.300 , Issue.8 , pp. 933-944
    • Wiener, R.S.1    Wiener, D.C.2    Larson, R.J.3
  • 17
    • 65349096195 scopus 로고    scopus 로고
    • Intensive insulin therapy and mortality among critically ill patients: A meta-analysis including NICE-SUGAR study data
    • Griesdale DE, de Souza RJ, van Dam RM, et al. Intensive insulin therapy and mortality among critically ill patients: a meta-analysis including NICE-SUGAR study data. CMAJ. 2009;180(8):821-827.
    • (2009) CMAJ. , vol.180 , Issue.8 , pp. 821-827
    • Griesdale, D.E.1    De Souza, R.J.2    Van Dam, R.M.3
  • 18
    • 84871995815 scopus 로고    scopus 로고
    • Standards of medical care in diabetes-2013
    • American Diabetes Association.
    • American Diabetes Association. Standards of medical care in diabetes-2013. Diabetes Care. 2013;36(suppl 1):S11-S66.
    • (2013) Diabetes Care. , vol.36 , pp. S11-S66
  • 19
    • 41849084928 scopus 로고    scopus 로고
    • ISO22870: 2006, Geneva: International Organization for Standardization
    • ISO22870:2006. Point-of-care testing (POCT)-requirements for quality and competence Geneva: International Organization for Standardization; 2006. Available at: http://www.iso.org/iso/catalogue-detail.htm?csnumber=35173.
    • (2006) Point-of-care Testing (POCT)-requirements for Quality and Competence
  • 20
    • 84865182208 scopus 로고    scopus 로고
    • A history of blood glucose meters and their role in self-monitoring of diabetes mellitus
    • Clarke SF, Foster JR. A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. Br J Biomed Sci. 2012;69(2):83-93.
    • (2012) Br J Biomed Sci. , vol.69 , Issue.2 , pp. 83-93
    • Clarke, S.F.1    Foster, J.R.2
  • 21
    • 84971583389 scopus 로고
    • Clinical lecture on the various modes of testing for sugar in the urine
    • Johnson G. Clinical lecture on the various modes of testing for sugar in the urine. BMJ. 1884;1(1201):1-4.
    • (1884) BMJ. , vol.1 , Issue.1201 , pp. 1-4
    • Johnson, G.1
  • 22
    • 0037134557 scopus 로고    scopus 로고
    • A reagent for the detection of reducing sugars. 1908
    • Benedict SR. A reagent for the detection of reducing sugars. 1908. J Biol Chem. 2002;277(16):e5.
    • (2002) J Biol Chem. , vol.277 , Issue.16 , pp. e5
    • Benedict, S.R.1
  • 24
    • 25444456037 scopus 로고
    • A rapid method of estimating blood-glucose ranges
    • Kohn J. A rapid method of estimating blood-glucose ranges. Lancet. 1957;273(6986):119-121.
    • (1957) Lancet. , vol.273 , Issue.6986 , pp. 119-121
    • Kohn, J.1
  • 25
    • 0021451910 scopus 로고
    • Self testing, an emerging component of clinical chemistry
    • Free AH, Free HM. Self testing, an emerging component of clinical chemistry. Clin Chem. 1984;30(6):829-838.
    • (1984) Clin Chem. , vol.30 , Issue.6 , pp. 829-838
    • Free, A.H.1    Free, H.M.2
  • 27
    • 84948163276 scopus 로고    scopus 로고
    • BCCResearch. Point of Care Diagnostics (Report code HLC043C) BCC Research
    • BCCResearch. Point of Care Diagnostics (Report code HLC043C) BCC Research; 2012. Available at: http://www.bccresearch.com/market-research/healthcare/point-of-carediagnostics-market-hlc043c.html.
    • (2012)
  • 28
    • 60749098536 scopus 로고    scopus 로고
    • Quality and timeliness in medical laboratory testing
    • Schimke I. Quality and timeliness in medical laboratory testing. Analy Bioanal Chem. 2009;393(5):1499-1504.
    • (2009) Analy Bioanal Chem. , vol.393 , Issue.5 , pp. 1499-1504
    • Schimke, I.1
  • 29
    • 0033923764 scopus 로고    scopus 로고
    • Point-of-care testing: Millennium technology for critical care
    • Louie RF, Tang Z, Shelby DG, Kost GJ. Point-of-care testing: millennium technology for critical care. Lab Med. 2000;31(7):402-408.
    • (2000) Lab Med. , vol.31 , Issue.7 , pp. 402-408
    • Louie, R.F.1    Tang, Z.2    Shelby, D.G.3    Kost, G.J.4
  • 30
    • 3042794161 scopus 로고    scopus 로고
    • College of American P. Comparative analytical costs of central laboratory glucose and bedside glucose testing: A College of American Pathologists Q-Probes study
    • Howanitz PJ, Jones BA, College of American P. Comparative analytical costs of central laboratory glucose and bedside glucose testing: a College of American Pathologists Q-Probes study. Arch Pathol Lab Med. 2004;128(7):739-745.
    • (2004) Arch Pathol Lab Med. , vol.128 , Issue.7 , pp. 739-745
    • Howanitz, P.J.1    Jones, B.A.2
  • 31
    • 54349120509 scopus 로고    scopus 로고
    • Laboratory turnaround time
    • Hawkins RC. Laboratory turnaround time. Clin Biochem Rev. 2007;28(4):179-194.
    • (2007) Clin Biochem Rev. , vol.28 , Issue.4 , pp. 179-194
    • Hawkins, R.C.1
  • 32
    • 0035031725 scopus 로고    scopus 로고
    • The essential role of information management in point-of-care/critical care testing
    • Blick KE. The essential role of information management in point-of-care/critical care testing. Clin Chim Acta. 2001;307(1-2):159-168.
    • (2001) Clin Chim Acta. , vol.307 , Issue.1-2 , pp. 159-168
    • Blick, K.E.1
  • 33
    • 0031877462 scopus 로고    scopus 로고
    • Evaluating stat testing options in an academic health center: Therapeutic turnaround time and staff satisfaction
    • Kilgore ML, Steindel SJ, Smith JA. Evaluating stat testing options in an academic health center: therapeutic turnaround time and staff satisfaction. Clin Chem. 1998;44(8 pt 1):1597-1603.
    • (1998) Clin Chem. , vol.44 , Issue.8 , pp. 1597-1603
    • Kilgore, M.L.1    Steindel, S.J.2    Smith, J.A.3
  • 35
    • 84855608554 scopus 로고    scopus 로고
    • The increasing burden of phlebotomy in the development of anaemia and need for blood transfusion amongst trauma patients
    • Branco BC, Inaba K, Doughty R, et al. The increasing burden of phlebotomy in the development of anaemia and need for blood transfusion amongst trauma patients. Injury. 2012;43(1):78-83.
    • (2012) Injury. , vol.43 , Issue.1 , pp. 78-83
    • Branco, B.C.1    Inaba, K.2    Doughty, R.3
  • 36
    • 0022621669 scopus 로고
    • Phlebotomy for diagnostic laboratory tests in adults. Pattern of use and effect on transfusion requirements
    • Smoller BR, Kruskall MS. Phlebotomy for diagnostic laboratory tests in adults. Pattern of use and effect on transfusion requirements. N Engl J Med. 1986;314(19):1233-1235.
    • (1986) N Engl J Med. , vol.314 , Issue.19 , pp. 1233-1235
    • Smoller, B.R.1    Kruskall, M.S.2
  • 37
    • 84881245732 scopus 로고    scopus 로고
    • Blood conservation devices in critical care: A narrative review
    • Page C, Retter A, Wyncoll D. Blood conservation devices in critical care: a narrative review. Ann Intensive Care. 2013;3(1):14.
    • (2013) Ann Intensive Care. , vol.3 , Issue.1 , pp. 14
    • Page, C.1    Retter, A.2    Wyncoll, D.3
  • 38
    • 67349218803 scopus 로고    scopus 로고
    • Pre-analytical workstations: A tool for reducing laboratory errors
    • Da Rin G. Pre-analytical workstations: a tool for reducing laboratory errors. Clin Chim Acta. 2009;404(1):68-74.
    • (2009) Clin Chim Acta. , vol.404 , Issue.1 , pp. 68-74
    • Da Rin, G.1
  • 39
    • 0034122945 scopus 로고    scopus 로고
    • Blood glucose: Measurement in the point-of-care setting
    • Kiechle FL, Main RI. Blood glucose: measurement in the point-of-care setting. Lab Med. 2000;31(5):276-282.
    • (2000) Lab Med. , vol.31 , Issue.5 , pp. 276-282
    • Kiechle, F.L.1    Main, R.I.2
  • 40
    • 80052238986 scopus 로고    scopus 로고
    • Quality error rates in point-of-care testing
    • O'Kane MJ, McManus P, McGowan N, Lynch PL. Quality error rates in point-of-care testing. Clin Chem. 2011;57(9):1267-1271.
    • (2011) Clin Chem. , vol.57 , Issue.9 , pp. 1267-1271
    • O'Kane, M.J.1    McManus, P.2    McGowan, N.3    Lynch, P.L.4
  • 41
    • 79958000536 scopus 로고    scopus 로고
    • Blood glucose testing in the hospital: Error sources and risk management
    • Nichols JH. Blood glucose testing in the hospital: error sources and risk management. J Diabetes Sci Technol. 2011;5(1):173-177.
    • (2011) J Diabetes Sci Technol. , vol.5 , Issue.1 , pp. 173-177
    • Nichols, J.H.1
  • 42
    • 67349234555 scopus 로고    scopus 로고
    • Post-analytical errors with portable glucose meters in the hospital setting
    • Carraro P, Plebani M. Post-analytical errors with portable glucose meters in the hospital setting. Clin Chim Acta. 2009;404(1):65-67.
    • (2009) Clin Chim Acta. , vol.404 , Issue.1 , pp. 65-67
    • Carraro, P.1    Plebani, M.2
  • 43
    • 67349154091 scopus 로고    scopus 로고
    • Does POCT reduce the risk of error in laboratory testing?
    • Plebani M. Does POCT reduce the risk of error in laboratory testing? Clin Chim Acta. 2009;404(1):59-64.
    • (2009) Clin Chim Acta. , vol.404 , Issue.1 , pp. 59-64
    • Plebani, M.1
  • 44
    • 33846681947 scopus 로고    scopus 로고
    • Glucose measurement: Confounding issues in setting targets for inpatient management
    • Dungan K, Chapman J, Braithwaite SS, Buse J. Glucose measurement: confounding issues in setting targets for inpatient management. Diabetes Care. 2007;30(2):403-409.
    • (2007) Diabetes Care. , vol.30 , Issue.2 , pp. 403-409
    • Dungan, K.1    Chapman, J.2    Braithwaite, S.S.3    Buse, J.4
  • 45
    • 84865124284 scopus 로고    scopus 로고
    • Accuracy of point-of-care glucose measurements
    • Rebel A, Rice MA, Fahy BG. Accuracy of point-of-care glucose measurements. J Diabetes Sci Technol. 2012;6(2):396-411.
    • (2012) J Diabetes Sci Technol. , vol.6 , Issue.2 , pp. 396-411
    • Rebel, A.1    Rice, M.A.2    Fahy, B.G.3
  • 46
    • 77249140803 scopus 로고    scopus 로고
    • Challenges to glycemic measurement in the perioperative and critically ill patient: A review
    • Pitkin AD, Rice MJ. Challenges to glycemic measurement in the perioperative and critically ill patient: a review. J Diabetes Sci Technol. 2009;3(6):1270-1281.
    • (2009) J Diabetes Sci Technol. , vol.3 , Issue.6 , pp. 1270-1281
    • Pitkin, A.D.1    Rice, M.J.2
  • 47
    • 70849119720 scopus 로고    scopus 로고
    • How accurately do we measure blood glucose levels in intensive care unit (ICU) patients? Best practice & research
    • Wahl HG. How accurately do we measure blood glucose levels in intensive care unit (ICU) patients? Best practice & research. Clin Anaesth. 2009;23(4):387-400.
    • (2009) Clin Anaesth. , vol.23 , Issue.4 , pp. 387-400
    • Wahl, H.G.1
  • 48
    • 24144459072 scopus 로고    scopus 로고
    • Approved IFCC recommendation on reporting results for blood glucose (abbreviated)
    • D'Orazio P, Burnett RW, Fogh-Andersen N, et al. Approved IFCC recommendation on reporting results for blood glucose (abbreviated). Clin Chem. 2005;51(9):1573-1576.
    • (2005) Clin Chem. , vol.51 , Issue.9 , pp. 1573-1576
    • D'Orazio, P.1    Burnett, R.W.2    Fogh-Andersen, N.3
  • 49
    • 70349495829 scopus 로고    scopus 로고
    • Analytical interferences in pointof- care testing glucometers by icodextrin and its metabolites: An overview
    • Flore KM, Delanghe JR. Analytical interferences in pointof- care testing glucometers by icodextrin and its metabolites: an overview. Perit Dial Int. 2009;29(4):377-383.
    • (2009) Perit Dial Int. , vol.29 , Issue.4 , pp. 377-383
    • Flore, K.M.1    Delanghe, J.R.2
  • 51
    • 77953064609 scopus 로고    scopus 로고
    • Finger-stick glucose monitoring: Issues of accuracy and specificity
    • Olansky L, Kennedy L. Finger-stick glucose monitoring: issues of accuracy and specificity. Diabetes Care. 2010;33(4):948-949.
    • (2010) Diabetes Care. , vol.33 , Issue.4 , pp. 948-949
    • Olansky, L.1    Kennedy, L.2
  • 52
    • 80052996492 scopus 로고    scopus 로고
    • The danger of using inappropriate point-of-care glucose meters in patients on icodextrin dialysis
    • Perera NJ, Stewart PM, Williams PF, Chua EL, Yue DK, Twigg SM. The danger of using inappropriate point-of-care glucose meters in patients on icodextrin dialysis. Diabetic Med. 2011;28(10):1272-1276.
    • (2011) Diabetic Med. , vol.28 , Issue.10 , pp. 1272-1276
    • Perera, N.J.1    Stewart, P.M.2    Williams, P.F.3    Chua, E.L.4    Yue, D.K.5    Twigg, S.M.6
  • 53
    • 84875045846 scopus 로고    scopus 로고
    • Accuracy of bloodglucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: Systematic review
    • Inoue S, Egi M, Kotani J, Morita K. Accuracy of bloodglucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review. Crit Care. 2013;17(2):R48.
    • (2013) Crit Care. , vol.17 , Issue.2 , pp. R48
    • Inoue, S.1    Egi, M.2    Kotani, J.3    Morita, K.4
  • 54
    • 0023239559 scopus 로고
    • Consensus statement on self-monitoring of blood glucose
    • American Diabetes Association.
    • American Diabetes Association. Consensus statement on self-monitoring of blood glucose. Diabetes Care. 1987;10(1):95-99.
    • (1987) Diabetes Care. , vol.10 , Issue.1 , pp. 95-99
  • 55
    • 0030066052 scopus 로고    scopus 로고
    • Sell-monitoring of blood glucose
    • American Diabetes Association.
    • American Diabetes Association. Sell-monitoring of blood glucose. Diabetes Care. 1996;19(suppl 1):S62-S66.
    • (1996) Diabetes Care. , vol.19 , pp. S62-S66
  • 57
    • 84948186037 scopus 로고    scopus 로고
    • ISO15197: 2013. Geneva, Switzerland: International Organization for Standardization
    • ISO15197:2013. Requirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus. Geneva, Switzerland: International Organization for Standardization; 2013. Available at: http://www.iso.org/iso/home/store/catalogue-tc/catalogue-detail.htm?csnumber=54976.
    • (2013) Requirements for Blood Glucose Monitoring Systems for Self-testing in Managing Diabetes Mellitus
  • 59
    • 77951733801 scopus 로고    scopus 로고
    • A review of standards and statistics used to describe blood glucose monitor performance
    • Krouwer JS, Cembrowski GS. A review of standards and statistics used to describe blood glucose monitor performance. J Diabetes Sci Technol. 2010;4(1):75-83.
    • (2010) J Diabetes Sci Technol. , vol.4 , Issue.1 , pp. 75-83
    • Krouwer, J.S.1    Cembrowski, G.S.2
  • 60
    • 77249122160 scopus 로고    scopus 로고
    • System accuracy evaluation of 27 blood glucose monitoring systems according to DIN en ISO 15197
    • Freckmann G, Baumstark A, Jendrike N, et al. System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197. Diabetes Technol Ther. 2010;12(3):221-231.
    • (2010) Diabetes Technol Ther. , vol.12 , Issue.3 , pp. 221-231
    • Freckmann, G.1    Baumstark, A.2    Jendrike, N.3
  • 61
    • 84875805117 scopus 로고    scopus 로고
    • System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN en ISO 15197
    • Freckmann G, Schmid C, Baumstark A, Pleus S, Link M, Haug C. System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197. J Diabetes Sci Technol. 2012;6(5):1060-1075.
    • (2012) J Diabetes Sci Technol. , vol.6 , Issue.5 , pp. 1060-1075
    • Freckmann, G.1    Schmid, C.2    Baumstark, A.3    Pleus, S.4    Link, M.5    Haug, C.6
  • 62
    • 84879706204 scopus 로고    scopus 로고
    • Tighter accuracy standards within point-of-care blood glucose monitoring: How six commonly used systems compare
    • Robinson CS, Sharp P. Tighter accuracy standards within point-of-care blood glucose monitoring: how six commonly used systems compare. J Diabetes Sci Technol. 2012;6(3): 547-554.
    • (2012) J Diabetes Sci Technol. , vol.6 , Issue.3 , pp. 547-554
    • Robinson, C.S.1    Sharp, P.2
  • 63
    • 79955557642 scopus 로고    scopus 로고
    • Accuracy and precision evaluation of seven self-monitoring blood glucose systems
    • Kuo CY, Hsu CT, Ho CS, Su TE, Wu MH, Wang CJ. Accuracy and precision evaluation of seven self-monitoring blood glucose systems. Diabetes Technol Ther. 2011;13(5):596-600.
    • (2011) Diabetes Technol Ther. , vol.13 , Issue.5 , pp. 596-600
    • Kuo, C.Y.1    Hsu, C.T.2    Ho, C.S.3    Su, T.E.4    Wu, M.H.5    Wang, C.J.6
  • 64
    • 84872923742 scopus 로고    scopus 로고
    • Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospitaluse meters in an intensive care unit
    • Gijzen K, Moolenaar DL, Weusten JJ, Pluim HJ, Demir AY. Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospitaluse meters in an intensive care unit. Clin Chem Lab Med. 2012;50(11):1985-1992.
    • (2012) Clin Chem Lab Med. , vol.50 , Issue.11 , pp. 1985-1992
    • Gijzen, K.1    Moolenaar, D.L.2    Weusten, J.J.3    Pluim, H.J.4    Demir, A.Y.5
  • 65
    • 84882939981 scopus 로고    scopus 로고
    • Performance variability of seven commonly used self-monitoring of blood glucose systems: Clinical considerations for patients and providers
    • Brazg RL, Klaff LJ, Parkin CG. Performance variability of seven commonly used self-monitoring of blood glucose systems: clinical considerations for patients and providers. J Diabetes Sci Technol. 2013;7(1):144-152.
    • (2013) J Diabetes Sci Technol. , vol.7 , Issue.1 , pp. 144-152
    • Brazg, R.L.1    Klaff, L.J.2    Parkin, C.G.3
  • 66
    • 84865134562 scopus 로고    scopus 로고
    • New criteria for assessing the accuracy of blood glucose monitors meeting, October 28, 2011
    • Walsh J, Roberts R, Vigersky RA, Schwartz F. New criteria for assessing the accuracy of blood glucose monitors meeting, October 28, 2011. J Diabetes Sci Technol. 2012;6(2):466-474.
    • (2012) J Diabetes Sci Technol. , vol.6 , Issue.2 , pp. 466-474
    • Walsh, J.1    Roberts, R.2    Vigersky, R.A.3    Schwartz, F.4
  • 69
    • 84897122879 scopus 로고    scopus 로고
    • Do currently available blood glucose monitors meet regulatory standards? 1-day public meeting in Arlington, Virginia
    • Klonoff DC, Reyes JS. Do currently available blood glucose monitors meet regulatory standards? 1-day public meeting in Arlington, Virginia. J Diabetes Sci Technol. 2013;7(4):1071-1083.
    • (2013) J Diabetes Sci Technol. , vol.7 , Issue.4 , pp. 1071-1083
    • Klonoff, D.C.1    Reyes, J.S.2
  • 70
    • 74549114632 scopus 로고    scopus 로고
    • Eliminating the blood: Ongoing outbreaks of hepatitis B virus infection and the need for innovative glucose monitoring technologies
    • Thompson ND, Perz JF. Eliminating the blood: ongoing outbreaks of hepatitis B virus infection and the need for innovative glucose monitoring technologies. J Diabetes Sci Technol. 2009;3(2):283-288.
    • (2009) J Diabetes Sci Technol. , vol.3 , Issue.2 , pp. 283-288
    • Thompson, N.D.1    Perz, J.F.2
  • 71
    • 84862687195 scopus 로고    scopus 로고
    • Never events": Hepatitis B outbreaks and patient notifications resulting from unsafe practices during assisted monitoring of blood glucose, 2009-2010
    • Thompson ND, Schaefer MK. "Never events": hepatitis B outbreaks and patient notifications resulting from unsafe practices during assisted monitoring of blood glucose, 2009- 2010. J Diabetes Sci Technol. 2011;5(6):1396-1402.
    • (2011) J Diabetes Sci Technol. , vol.5 , Issue.6 , pp. 1396-1402
    • Thompson, N.D.1    Schaefer, M.K.2
  • 74
    • 84984945194 scopus 로고    scopus 로고
    • Multicenter study of the prevalence of blood contamination on point-ofcare glucose meters and recommendations for controlling contamination
    • Louie RF, Lau MJ, Lee JH, Tang Z, Kost GJ. Multicenter study of the prevalence of blood contamination on point-ofcare glucose meters and recommendations for controlling contamination. Point of Care. 2005;4(4):158-163.
    • (2005) Point of Care. , vol.4 , Issue.4 , pp. 158-163
    • Louie, R.F.1    Lau, M.J.2    Lee, J.H.3    Tang, Z.4    Kost, G.J.5
  • 75
    • 84862661304 scopus 로고    scopus 로고
    • Multicenter evaluation of bacterial contamination of glucose test strips
    • Ng R, Koo S, Johnston R. Multicenter evaluation of bacterial contamination of glucose test strips. Clin Chim Acta. 2012;413(19-20):1485-1487.
    • (2012) Clin Chim Acta. , vol.413 , Issue.19-20 , pp. 1485-1487
    • Ng, R.1    Koo, S.2    Johnston, R.3
  • 76
    • 80052023021 scopus 로고    scopus 로고
    • Bacterial contamination of glucose test strips: Not to be neglected
    • Vanhaeren S, Duport C, Magneney M, et al. Bacterial contamination of glucose test strips: not to be neglected. Am J Infect Control. 2011;39(7):611-613.
    • (2011) Am J Infect Control. , vol.39 , Issue.7 , pp. 611-613
    • Vanhaeren, S.1    Duport, C.2    Magneney, M.3
  • 77
    • 84897121316 scopus 로고    scopus 로고
    • Prevalence of bacterial contamination of glucose test strips in individual single-use packets versus multiple-use vials
    • Perez-Ayala M, Oliver P, Rodriguez Cantalejo F. Prevalence of bacterial contamination of glucose test strips in individual single-use packets versus multiple-use vials. J Diabetes Sci Technol. 2013;7(4):854-862.
    • (2013) J Diabetes Sci Technol. , vol.7 , Issue.4 , pp. 854-862
    • Perez-Ayala, M.1    Oliver, P.2    Rodriguez Cantalejo, F.3
  • 79
    • 84948180095 scopus 로고    scopus 로고
    • Centers for Disease Control and Prevention, Centers for Disease Control and Prevention
    • Centers for Disease Control and Prevention. Diabetes and viral hepatitis: important information on glucose monitoring. Centers for Disease Control and Prevention; 2012. Available at: http://www.cdc.gov/hepatitis/Settings/GlucoseMonitoring.htm.
    • (2012) Diabetes and Viral Hepatitis: Important Information on Glucose Monitoring.
  • 80
    • 84866299873 scopus 로고    scopus 로고
    • Estimated strip wastage from glucose meter infection control recommendations
    • Nichols JH. Estimated strip wastage from glucose meter infection control recommendations. Clin Chim Acta. 2012;414: 91-92.
    • (2012) Clin Chim Acta. , vol.414 , pp. 91-92
    • Nichols, J.H.1
  • 82
    • 0033838334 scopus 로고    scopus 로고
    • Connectivity. The millennium challenge for pointof- care testing
    • Kost GJ. Connectivity. The millennium challenge for pointof- care testing. Arch Pathol Lab Med. 2000;124(8):1108-1110.
    • (2000) Arch Pathol Lab Med. , vol.124 , Issue.8 , pp. 1108-1110
    • Kost, G.J.1
  • 83
    • 84930064937 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute.
    • Clinical and Laboratory Standards Institute. Point-of-care connectivity; approved standard. 2nd ed. 2006. Available at: http://www.clsi.org/standards/.
    • (2006) Point-of-care Connectivity; Approved Standard. 2nd Ed
  • 84
    • 84962971552 scopus 로고    scopus 로고
    • Connectivity for point-of-care glucose testing reduces error and increases compliance
    • Salka L, Kiechle FL. Connectivity for point-of-care glucose testing reduces error and increases compliance. Point of Care. 2003;2(2):114-118.
    • (2003) Point of Care. , vol.2 , Issue.2 , pp. 114-118
    • Salka, L.1    Kiechle, F.L.2
  • 85
    • 70350020641 scopus 로고    scopus 로고
    • Point-of-care testing informatics
    • Kim JY, Lewandrowski K. Point-of-care testing informatics. Clin Lab Med. 2009;29(3):449-461.
    • (2009) Clin Lab Med. , vol.29 , Issue.3 , pp. 449-461
    • Kim, J.Y.1    Lewandrowski, K.2
  • 86
    • 33845667974 scopus 로고    scopus 로고
    • "Glucometrics"- assessing the quality of inpatient glucose management
    • Goldberg PA, Bozzo JE, Thomas PG, et al. "Glucometrics"- assessing the quality of inpatient glucose management. Diabetes Technol Ther. 2006;8(5):560-569.
    • (2006) Diabetes Technol Ther. , vol.8 , Issue.5 , pp. 560-569
    • Goldberg, P.A.1    Bozzo, J.E.2    Thomas, P.G.3
  • 87
    • 84874570201 scopus 로고    scopus 로고
    • Trends in glycemic control over a 2-year period in 126 US hospitals
    • Bersoux S, Cook CB, Kongable GL, Shu J. Trends in glycemic control over a 2-year period in 126 US hospitals. J Hosp Med. 2013;8(3):121-125.
    • (2013) J Hosp Med. , vol.8 , Issue.3 , pp. 121-125
    • Bersoux, S.1    Cook, C.B.2    Kongable, G.L.3    Shu, J.4
  • 88
    • 36349017754 scopus 로고    scopus 로고
    • Inpatient point-of-care bedside glucose testing: Preliminary data on use of connectivity informatics to measure hospital glycemic control
    • Cook CB, Moghissi E, Joshi R, Kongable GL, Abad VJ. Inpatient point-of-care bedside glucose testing: preliminary data on use of connectivity informatics to measure hospital glycemic control. Diabetes Technol Ther. 2007;9(6): 493-500.
    • (2007) Diabetes Technol Ther. , vol.9 , Issue.6 , pp. 493-500
    • Cook, C.B.1    Moghissi, E.2    Joshi, R.3    Kongable, G.L.4    Abad, V.J.5
  • 89
    • 77953060177 scopus 로고    scopus 로고
    • Institutional blood glucose monitoring system for hospitalized patients: An integral component of the inpatient glucose control program
    • Boaz M, Landau Z, Matas Z, Wainstein J. Institutional blood glucose monitoring system for hospitalized patients: an integral component of the inpatient glucose control program. J Diabetes Sci Technol. 2009;3(5):1168-1174.
    • (2009) J Diabetes Sci Technol. , vol.3 , Issue.5 , pp. 1168-1174
    • Boaz, M.1    Landau, Z.2    Matas, Z.3    Wainstein, J.4
  • 90
    • 84887201165 scopus 로고    scopus 로고
    • An internet service supporting quality assessment of inpatient glycemic control
    • Thomas P, Inzucchi SE. An internet service supporting quality assessment of inpatient glycemic control. J Diabetes Sci Technol. 2008;2(3):402-408.
    • (2008) J Diabetes Sci Technol. , vol.2 , Issue.3 , pp. 402-408
    • Thomas, P.1    Inzucchi, S.E.2
  • 91
    • 84861169051 scopus 로고    scopus 로고
    • Clinical decision support systems in the care of inpatients with diabetes in non-critical care setting: Systematic review
    • Nirantharakumar K, Chen YF, Marshall T, Webber J, Coleman JJ. Clinical decision support systems in the care of inpatients with diabetes in non-critical care setting: systematic review. Diabetic Med. 2012;29(6):698-708.
    • (2012) Diabetic Med. , vol.29 , Issue.6 , pp. 698-708
    • Nirantharakumar, K.1    Chen, Y.F.2    Marshall, T.3    Webber, J.4    Coleman, J.J.5
  • 92
    • 84887624978 scopus 로고    scopus 로고
    • Diurnal temporal patterns of hypoglycaemia in hospitalized people with diabetes may reveal potentially correctable factors
    • Kerry C, Mitchell S, Sharma S, Scott A, Rayman G. Diurnal temporal patterns of hypoglycaemia in hospitalized people with diabetes may reveal potentially correctable factors. Diabetic Med. 2013;30(12):1403-1406.
    • (2013) Diabetic Med. , vol.30 , Issue.12 , pp. 1403-1406
    • Kerry, C.1    Mitchell, S.2    Sharma, S.3    Scott, A.4    Rayman, G.5
  • 93
    • 0028068885 scopus 로고
    • Utilization and cost analysis of bedside capillary glucose testing in a large teaching hospital: Implications for managing point of care testing
    • Lee-Lewandrowski E, Laposata M, Eschenbach K, et al. Utilization and cost analysis of bedside capillary glucose testing in a large teaching hospital: implications for managing point of care testing. Am J Med. 1994;97(3):222-230.
    • (1994) Am J Med. , vol.97 , Issue.3 , pp. 222-230
    • Lee-Lewandrowski, E.1    Laposata, M.2    Eschenbach, K.3
  • 94
    • 0026533917 scopus 로고
    • Cost analysis. Bedside blood glucose testing
    • Greendyke RM. Cost analysis. Bedside blood glucose testing. Am J Clin Pathol. 1992;97(1):106-107.
    • (1992) Am J Clin Pathol. , vol.97 , Issue.1 , pp. 106-107
    • Greendyke, R.M.1
  • 95
    • 0028120370 scopus 로고
    • The fiscal consequences of central vs distributed testing of glucose
    • Winkelman JW, Wybenga DR, Tanasijevic MJ. The fiscal consequences of central vs distributed testing of glucose. Clin Chem. 1994;40(8):1628-1630.
    • (1994) Clin Chem. , vol.40 , Issue.8 , pp. 1628-1630
    • Winkelman, J.W.1    Wybenga, D.R.2    Tanasijevic, M.J.3
  • 96
    • 0028797499 scopus 로고
    • Cost analysis of point-of-care laboratory testing in a community hospital
    • Nosanchuk JS, Keefner R. Cost analysis of point-of-care laboratory testing in a community hospital. Am J Clin Pathol. 1995;103(2):240-243.
    • (1995) Am J Clin Pathol. , vol.103 , Issue.2 , pp. 240-243
    • Nosanchuk, J.S.1    Keefner, R.2
  • 97
    • 0029781553 scopus 로고    scopus 로고
    • Assessment of a critical limit protocol for point-ofcare glucose testing
    • Lum G. Assessment of a critical limit protocol for point-ofcare glucose testing. Am J Clin Pathol. 1996;106(3):390-395.
    • (1996) Am J Clin Pathol. , vol.106 , Issue.3 , pp. 390-395
    • Lum, G.1
  • 98
    • 23044466536 scopus 로고    scopus 로고
    • Does point-of-care testing save money or cost more?
    • Hortin GL. Does point-of-care testing save money or cost more? Lab Med. 2005;36(8):465-467.
    • (2005) Lab Med. , vol.36 , Issue.8 , pp. 465-467
    • Hortin, G.L.1
  • 100
    • 77649259538 scopus 로고    scopus 로고
    • Real-time continuous glucose monitoring in critically ill patients: A prospective randomized trial
    • Holzinger U, Warszawska J, Kitzberger R, et al. Real-time continuous glucose monitoring in critically ill patients: a prospective randomized trial. Diabetes Care. 2010;33(3):467-472.
    • (2010) Diabetes Care. , vol.33 , Issue.3 , pp. 467-472
    • Holzinger, U.1    Warszawska, J.2    Kitzberger, R.3
  • 101
    • 84882945980 scopus 로고    scopus 로고
    • Evaluation of a continuous blood glucose monitoring system using central venous microdialysis
    • Schierenbeck F, Franco-Cereceda A, Liska J. Evaluation of a continuous blood glucose monitoring system using central venous microdialysis. J Diabetes Sci Technol. 2012;6(6):1365-1371.
    • (2012) J Diabetes Sci Technol. , vol.6 , Issue.6 , pp. 1365-1371
    • Schierenbeck, F.1    Franco-Cereceda, A.2    Liska, J.3
  • 102
    • 79953167996 scopus 로고    scopus 로고
    • Accuracy and reliability of a subcutaneous continuous glucose-monitoring system in critically ill patients
    • Brunner R, Kitzberger R, Miehsler W, Herkner H, Madl C, Holzinger U. Accuracy and reliability of a subcutaneous continuous glucose-monitoring system in critically ill patients. Crit Care Med. 2011;39(4):659-664.
    • (2011) Crit Care Med. , vol.39 , Issue.4 , pp. 659-664
    • Brunner, R.1    Kitzberger, R.2    Miehsler, W.3    Herkner, H.4    Madl, C.5    Holzinger, U.6
  • 103
    • 67650838755 scopus 로고    scopus 로고
    • Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring
    • Holzinger U, Warszawska J, Kitzberger R, Herkner H, Metnitz PG, Madl C. Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring. Intensive Care Med. 2009;35(8):1383-1389.
    • (2009) Intensive Care Med. , vol.35 , Issue.8 , pp. 1383-1389
    • Holzinger, U.1    Warszawska, J.2    Kitzberger, R.3    Herkner, H.4    Metnitz, P.G.5    Madl, C.6
  • 104
    • 78349281594 scopus 로고    scopus 로고
    • Continuous glucose monitoring system in a rural intensive care unit: A pilot study evaluating accuracy and acceptance
    • Jacobs B, Phan K, Bertheau L, Dogbey G, Schwartz F, Shubrook J. Continuous glucose monitoring system in a rural intensive care unit: a pilot study evaluating accuracy and acceptance. J Diabetes Sci Technol. 2010;4(3):636-644.
    • (2010) J Diabetes Sci Technol. , vol.4 , Issue.3 , pp. 636-644
    • Jacobs, B.1    Phan, K.2    Bertheau, L.3    Dogbey, G.4    Schwartz, F.5    Shubrook, J.6
  • 105
    • 77953062418 scopus 로고    scopus 로고
    • Numerical and clinical accuracy of a continuous glucose monitoring system during intravenous insulin therapy in the surgical and burn intensive care units
    • Rabiee A, Andreasik V, Abu-Hamdah R, et al. Numerical and clinical accuracy of a continuous glucose monitoring system during intravenous insulin therapy in the surgical and burn intensive care units. J Diabetes Sci Technol. 2009;3(4):951-959.
    • (2009) J Diabetes Sci Technol. , vol.3 , Issue.4 , pp. 951-959
    • Rabiee, A.1    Andreasik, V.2    Abu-Hamdah, R.3
  • 106
    • 84857873148 scopus 로고    scopus 로고
    • Continuous glucose monitoring in patients undergoing cardiac surgery
    • Kalmovich B, Bar-Dayan Y, Boaz M, Wainstein J. Continuous glucose monitoring in patients undergoing cardiac surgery. Diabetes Technol Ther. 2012;14(3):232-238.
    • (2012) Diabetes Technol Ther. , vol.14 , Issue.3 , pp. 232-238
    • Kalmovich, B.1    Bar-Dayan, Y.2    Boaz, M.3    Wainstein, J.4
  • 108
    • 80053543458 scopus 로고    scopus 로고
    • Continuous glucose monitoring: An endocrine society clinical practice guideline
    • Klonoff DC, Buckingham B, Christiansen JS, et al. Continuous glucose monitoring: an endocrine society clinical practice guideline. J Clin Endocrinol Metab. 2011;96(10):2968-2979.
    • (2011) J Clin Endocrinol Metab. , vol.96 , Issue.10 , pp. 2968-2979
    • Klonoff, D.C.1    Buckingham, B.2    Christiansen, J.S.3
  • 109
    • 78149317247 scopus 로고    scopus 로고
    • Statement by the American Association of Clinical Endocrinologists Consensus Panel on continuous glucose monitoring
    • Blevins TC, Bode BW, Garg SK, et al. Statement by the American Association of Clinical Endocrinologists Consensus Panel on continuous glucose monitoring. Endocr Pract. 2010;16(5):730-745.
    • (2010) Endocr Pract. , vol.16 , Issue.5 , pp. 730-745
    • Blevins, T.C.1    Bode, B.W.2    Garg, S.K.3
  • 110
    • 0020077396 scopus 로고
    • Noninvasive glucose monitoring of the aqueous humor of the eye: Part I. Measurement of very small optical rotations
    • Rabinovitch B, March WF, Adams RL. Noninvasive glucose monitoring of the aqueous humor of the eye: Part I. Measurement of very small optical rotations. Diabetes Care. 1982;5(3):254-258.
    • (1982) Diabetes Care. , vol.5 , Issue.3 , pp. 254-258
    • Rabinovitch, B.1    March, W.F.2    Adams, R.L.3
  • 111
    • 84867334156 scopus 로고    scopus 로고
    • Non-invasive glucose monitoring technology in diabetes management: A review
    • Vashist SK. Non-invasive glucose monitoring technology in diabetes management: a review. Anal Chim Acta. 2012;750(0):16-27.
    • (2012) Anal Chim Acta. , vol.750 , pp. 16-27
    • Vashist, S.K.1
  • 112
    • 84855888268 scopus 로고    scopus 로고
    • Non-invasive methods of glucose measurement: Current status and future perspectives
    • Ciudin A, Hernandez C, Simo R. Non-invasive methods of glucose measurement: current status and future perspectives. Curr Diabetes Rev. 2012;8(1):48-54.
    • (2012) Curr Diabetes Rev. , vol.8 , Issue.1 , pp. 48-54
    • Ciudin, A.1    Hernandez, C.2    Simo, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.