메뉴 건너뛰기




Volumn 3, Issue 6, 2009, Pages 1270-1281

Challenges to glycemic measurement in the perioperative and critically ill patient: A review

Author keywords

Glucometer; Glucose measurement; Intense insulin therapy; Intraoperative; Laboratory; Perioperative; Point of care device

Indexed keywords

BLOOD; BLOOD GLUCOSE MONITORING; CRITICAL ILLNESS; EQUIPMENT; EQUIPMENT DESIGN; EVIDENCE BASED MEDICINE; GLUCOSE BLOOD LEVEL; HOSPITAL INFORMATION SYSTEM; HOSPITAL PATIENT; HUMAN; HYPOGLYCEMIA; INSTRUMENTATION; INTENSIVE CARE; METABOLISM; PERIOPERATIVE PERIOD; PREDICTION AND FORECASTING; REPRODUCIBILITY; REVIEW; SURGERY;

EID: 77249140803     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229680900300606     Document Type: Conference Paper
Times cited : (39)

References (70)
  • 3
    • 34250006566 scopus 로고    scopus 로고
    • Intensive insulin therapy in the ICU: Is it now time to jump off the bandwagon?
    • DOI 10.1016/j.resuscitation.2007.01.023, PII S0300957207000378
    • Marik PE, Varon J. Intensive insulin therapy in the ICU: is it now time to jump off the bandwagon? Resuscitation. 2007;74(1):191-93. (Pubitemid 46891675)
    • (2007) Resuscitation , vol.74 , Issue.1 , pp. 191-193
    • Marik, P.E.1    Varon, J.2
  • 4
    • 55449125205 scopus 로고    scopus 로고
    • Relationship of perioperative hyperglycemia and postoperative infections in patients who undergo general and vascular surgery
    • Ramos M, Khalpey Z, Lipsitz S, Steinberg J, Panizales MT, Zinner M, Rogers SO. Relationship of perioperative hyperglycemia and postoperative infections in patients who undergo general and vascular surgery. Ann Surg. 2008;248(4):585-91.
    • (2008) Ann Surg , vol.248 , Issue.4 , pp. 585-591
    • Ramos, M.1    Khalpey, Z.2    Lipsitz, S.3    Steinberg, J.4    Panizales, M.T.5    Zinner, M.6    Rogers, S.O.7
  • 8
    • 0036808798 scopus 로고    scopus 로고
    • Perioperative hyperglycemia is a strong correlate of postoperative infection in type II diabetic patients after coronary artery bypass grafting
    • DOI 10.1507/endocrj.49.531
    • Guvener M, Pasaoglu I, Demircin M, Oc M. Perioperative hyperglycemia is a strong correlate of postoperative infection in type II diabetic patients after coronary artery bypass grafting. Endocr J. 2002;49(5):531-7. (Pubitemid 35333999)
    • (2002) Endocrine Journal , vol.49 , Issue.5 , pp. 531-537
    • Guvener, M.1    Pasaoglu, I.2    Demircin, M.3    Oc, M.4
  • 10
    • 33947495107 scopus 로고    scopus 로고
    • Eliminating the Diabetic Disadvantage: The Portland Diabetic Project
    • DOI 10.1053/j.semtcvs.2006.04.005, PII S1043067906000165, Diabetes, Hyperglycemia, and Cardiac Surgery Patient
    • Furnary AP, Wu Y. Eliminating the diabetic disadvantage: the Portland Diabetic Project. Semin Thorac Cardiovasc Surg. 2006;18(4):302-8. (Pubitemid 46464509)
    • (2006) Seminars in Thoracic and Cardiovascular Surgery , vol.18 , Issue.4 , pp. 302-308
    • Furnary, A.P.1    Wu, Y.2
  • 13
    • 84887565779 scopus 로고    scopus 로고
    • Scientific principles and clinical implications of perioperative glucose regulation and control
    • In press
    • Akhtar S, Barash PG, Inzucchi SE. Scientific principles and clinical implications of perioperative glucose regulation and control. Anesth Analg. In press 2009.
    • (2009) Anesth Analg
    • Akhtar, S.1    Barash, P.G.2    Inzucchi, S.E.3
  • 14
    • 15244338874 scopus 로고    scopus 로고
    • Genes and pathophysiology of type 2 diabetes: More than just the Radle cycle all over again
    • DOI 10.1172/JCI200423586
    • Shuldiner AR, McLenithan JC. Genes and pathophysiology of type 2 diabetes: more than just the Randle cycle all over again. J Clin Invest. 2004;114(10):1414-7. (Pubitemid 40385572)
    • (2004) Journal of Clinical Investigation , vol.114 , Issue.10 , pp. 1414-1417
    • Shuldiner, A.R.1    McLenithan, J.C.2
  • 15
    • 4043077961 scopus 로고    scopus 로고
    • Molecular mediators of hepatic steatosis and liver injury
    • DOI 10.1172/JCI200422422
    • Browning JD, Horton JD. Molecular mediators of hepatic steatosis and liver injury. J Clin Invest. 2004;114(2):147-52. (Pubitemid 39071617)
    • (2004) Journal of Clinical Investigation , vol.114 , Issue.2 , pp. 147-152
    • Browning, J.D.1    Horton, J.D.2
  • 16
    • 40249120466 scopus 로고    scopus 로고
    • Standards of medical care in diabetes - 2008
    • American Diabetes Association
    • American Diabetes Association. Standards of medical care in diabetes - 2008. Diabetes Care. 2008;31 Suppl 1:S12-54.
    • (2008) Diabetes Care , vol.31 , Issue.SUPPL. 1
  • 18
    • 37549020378 scopus 로고    scopus 로고
    • Surviving Sepsis Campaign: International guidelines for management of severe sepsis and septic shock: 2008
    • International Surviving Sepsis Campaign Guidelines Committee; American Association of Critical-Care Nurses; American College of Chest Physicians; American College of Emergency Physicians; Canadian Critical Care Society; European Society of Clinical Microbiology and Infectious Diseases; European Society of Intensive Care Medicine; European Respiratory Society; International Sepsis Forum; Japanese Association for Acute Medicine; Japanese Society of Intensive Care Medicine; Society of Critical Care Medicine; Society of Hospital Medicine; Surgical Infection Society; World Federation of Societies of Intensive and Critical Care Medicine
    • Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R, Reinhart K, Angus DC, Brun-Buisson C, Beale R, Calandra T, Dhainaut JF, Gerlach H, Harvey M, Marini JJ, Marshall J, Ranieri M, Ramsay G, Sevransky J, Thompson BT, Townsend S, Vender JS, Zimmerman JL, Vincent JL; International Surviving Sepsis Campaign Guidelines Committee; American Association of Critical-Care Nurses; American College of Chest Physicians; American College of Emergency Physicians; Canadian Critical Care Society; European Society of Clinical Microbiology and Infectious Diseases; European Society of Intensive Care Medicine; European Respiratory Society; International Sepsis Forum; Japanese Association for Acute Medicine; Japanese Society of Intensive Care Medicine; Society of Critical Care Medicine; Society of Hospital Medicine; Surgical Infection Society; World Federation of Societies of Intensive and Critical Care Medicine. Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008. Crit Care Med. 2008;36(1):296-327.
    • (2008) Crit Care Med , vol.36 , Issue.1 , pp. 296-327
    • Dellinger, R.P.1    Levy, M.M.2    Carlet, J.M.3    Bion, J.4    Parker, M.M.5    Jaeschke, R.6    Reinhart, K.7    Angus, D.C.8    Brun-Buisson, C.9    Beale, R.10    Calandra, T.11    Dhainaut, J.F.12    Gerlach, H.13    Harvey, M.14    Marini, J.J.15    Marshall, J.16    Ranieri, M.17    Ramsay, G.18    Sevransky, J.19    Thompson, B.T.20    more..
  • 20
    • 67649183171 scopus 로고    scopus 로고
    • American Association of Clinical Endocrinologists and American Diabetes Association Consensus statement on inpatient glycemic control
    • American Association of Clinical Endocrinologists; American Diabetes Association
    • Moghissi ES, Korytkowski MT, DiNardo M, Einhorn D, Hellman R, Hirsch IB, Inzucchi SE, Ismail-Beigi F, Kirkman MS, Umpierrez GE; American Association of Clinical Endocrinologists; American Diabetes Association. American Association of Clinical Endocrinologists and American Diabetes Association Consensus statement on inpatient glycemic control. Endocr Pract. 2009;15(4):353-69.
    • (2009) Endocr Pract , vol.15 , Issue.4 , pp. 353-369
    • Moghissi, E.S.1    Korytkowski, M.T.2    DiNardo, M.3    Einhorn, D.4    Hellman, R.5    Hirsch, I.B.6    Inzucchi, S.E.7    Ismail-Beigi, F.8    Kirkman, M.S.9    Umpierrez, G.E.10
  • 21
    • 0025306522 scopus 로고
    • What is blood glucose: Can it be measured?
    • Burrin JM, Alberti KG. What is blood glucose: can it be measured? Diabet Med. 1990;7(3):199-206. (Pubitemid 20104132)
    • (1990) Diabetic Medicine , vol.7 , Issue.3 , pp. 199-206
    • Burrin, J.M.1    Alberti, K.G.M.M.2
  • 22
    • 33845684564 scopus 로고    scopus 로고
    • Approved IFCC recommendation on reporting results for blood glucose: International Federation of Clinical Chemistry and Laboratory Medicine Scientific Division, Working Group on Selective Electrodes and Point-of-Care Testing (IFCC-SD-WG-SEPOCT)
    • IFCC-SD-WG-SEPOCT
    • D'Orazio P, Burnett RW, Fogh-Andersen N, Jacobs E, Kuwa K, Kulpmann WR, Larsson L, Lewenstam A, Maas AH, Mager G, Naskalski JW, Okorodudu AO; IFCC-SD-WG-SEPOCT. Approved IFCC recommendation on reporting results for blood glucose: International Federation of Clinical Chemistry and Laboratory Medicine Scientific Division, Working Group on Selective Electrodes and Point-of-Care Testing (IFCC-SD-WG-SEPOCT). Clin Chem Lab Med. 2006;44(12):1486-90.
    • (2006) Clin Chem Lab Med , vol.44 , Issue.12 , pp. 1486-1490
    • D'Orazio, P.1    Burnett, R.W.2    Fogh-Andersen, N.3    Jacobs, E.4    Kuwa, K.5    Kulpmann, W.R.6    Larsson, L.7    Lewenstam, A.8    Maas, A.H.9    Mager, G.10    Naskalski, J.W.11    Okorodudu, A.O.12
  • 23
    • 0025967338 scopus 로고
    • Influence of sample type on the interpretation of the oral glucose tolerance test for gestational diabetes mellitus
    • Neely RD, Kiwanuka JB, Hadden DR. Influence of sample type on the interpretation of the oral glucose tolerance test for gestational diabetes mellitus. Diabet Med. 1991;8(2):129-34.
    • (1991) Diabet Med , vol.8 , Issue.2 , pp. 129-134
    • Neely, R.D.1    Kiwanuka, J.B.2    Hadden, D.R.3
  • 28
    • 34250620535 scopus 로고    scopus 로고
    • Accuracy of roche accu-chek inform whole blood capillary, arterial, and venous glucose values in patients receiving intensive intravenous insulin therapy after cardiac surgery
    • Karon BS, Gandhi GY, Nuttall GA, Bryant SC, Schaff HV, McMahon MM, Santrach PJ. Accuracy of roche accu-chek inform whole blood capillary, arterial, and venous glucose values in patients receiving intensive intravenous insulin therapy after cardiac surgery. Am J Clin Pathol. 2007;127(6):919-26.
    • (2007) Am J Clin Pathol , vol.127 , Issue.6 , pp. 919-926
    • Karon, B.S.1    Gandhi, G.Y.2    Nuttall, G.A.3    Bryant, S.C.4    Schaff, H.V.5    McMahon, M.M.6    Santrach, P.J.7
  • 29
    • 0028262386 scopus 로고
    • Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: Are they accurate?
    • Maser RE, Butler MA, DeCherney GS. Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: are they accurate? Crit Care Med. 1994;22(4):595-9. (Pubitemid 24121559)
    • (1994) Critical Care Medicine , vol.22 , Issue.4 , pp. 595-599
    • Maser, R.E.1    Butler, M.A.2    DeCherney, G.S.3
  • 30
    • 50049124154 scopus 로고    scopus 로고
    • Comparison of POCT and central laboratory blood glucose results using arterial, capillary, and venous samples from MICU patients on a tight glycemic protocol
    • Petersen JR, Graves DF, Tacker DH, Okorodudu AO, Mohammad AA, Cardenas VJ Jr. Comparison of POCT and central laboratory blood glucose results using arterial, capillary, and venous samples from MICU patients on a tight glycemic protocol. Clin Chim Acta. 2008;396(1-2):10-3.
    • (2008) Clin Chim Acta , vol.396 , Issue.1-2 , pp. 10-13
    • Petersen, J.R.1    Graves, D.F.2    Tacker, D.H.3    Okorodudu, A.O.4    Mohammad, A.A.5    Cardenas Jr., V.J.6
  • 35
    • 36448969381 scopus 로고    scopus 로고
    • Accuracy of bedside capillary blood glucose measurements in critically ill patients
    • DOI 10.1007/s00134-007-0835-4
    • Critchell CD, Savarese V, Callahan A, Aboud C, Jabbour S, Marik P. Accuracy of bedside capillary blood glucose measurements in critically ill patients. Intensive Care Med. 2007;33(12):2079-84. (Pubitemid 350164561)
    • (2007) Intensive Care Medicine , vol.33 , Issue.12 , pp. 2079-2084
    • Critchell, C.D.1    Savarese, V.2    Callahan, A.3    Aboud, C.4    Jabbour, S.5    Marik, P.6
  • 36
    • 42149100490 scopus 로고    scopus 로고
    • Accuracy of bedside glucometry in critically ill patients: Influence of clinical characteristics and perfusion index
    • DOI 10.4065/83.4.400
    • Desachy A, Vuagnat AC, Ghazali AD, Baudin OT, Longuet OH, Calvat SN, Gissot V. Accuracy of bedside glucometry in critically ill patients: influence of clinical characteristics and perfusion index. Mayo Clin Proc. 2008;83(4):400-5. (Pubitemid 351536465)
    • (2008) Mayo Clinic Proceedings , vol.83 , Issue.4 , pp. 400-405
    • Desachy, A.1    Vuagnat, A.C.2    Ghazali, A.D.3    Baudin, O.T.4    Longuet, O.H.5    Calvat, S.N.6    Gissot, V.7
  • 38
    • 33846681947 scopus 로고    scopus 로고
    • Glucose measurement: Confounding issues in setting targets for inpatient management
    • DOI 10.2337/dc06-1679
    • Dungan K, Chapman J, Braithwaite SS, Buse J. Glucose measurement: confounding issues in setting targets for inpatient management. Diabetes Care. 2007;30(2):403-9. (Pubitemid 46198356)
    • (2007) Diabetes Care , vol.30 , Issue.2 , pp. 403-409
    • Dungan, K.1    Chapman, J.2    Braithwaite, S.S.3    Buse, J.4
  • 39
    • 0033966742 scopus 로고    scopus 로고
    • Point-of-care glucose testing: Effects of critical care variables, influence of reference instruments, and a modular glucose meter design
    • Louie RF, Tang Z, Sutton, DV, Lee JH, Kost GJ. Point-of-care glucose testing: effects of critical care variables, influence of reference instruments, and a modular glucose meter design. Arch Pathol Lab Med. 2000;124(2):257-66. (Pubitemid 30090612)
    • (2000) Archives of Pathology and Laboratory Medicine , vol.124 , Issue.2 , pp. 257-266
    • Louie, R.F.1    Tang, Z.2    Sutton, D.V.3    Lee, J.H.4    Kost, G.J.5
  • 40
    • 0031282969 scopus 로고    scopus 로고
    • Evaluation of HemoCue Blood Glucose Analyzer for the instant diagnosis of hypoglycaemia in the newborns
    • Dahlberg M, Whitelaw A. Evaluation of HemoCue Blood Glucose Analyzer for the instant diagnosis of hypoglycaemia in newborns. Scand J Clin Lab Invest. 1997;57(8):719-24. (Pubitemid 28020556)
    • (1997) Scandinavian Journal of Clinical and Laboratory Investigation , vol.57 , Issue.8 , pp. 719-724
    • Dahlberg, M.1    Whitelaw, A.2
  • 42
    • 29744438635 scopus 로고    scopus 로고
    • The Accutrend sensor glucose analyzer may not be adequate in bedside testing for neonatal hypoglycemia
    • Rosenthal M, Ugele B, Lipowsky G, Kuster H. The Accutrend sensor glucose analyzer may not be adequate in bedside testing for neonatal hypoglycemia. Eur J Pediatr. 2006;165(2):99-103.
    • (2006) Eur J Pediatr , vol.165 , Issue.2 , pp. 99-103
    • Rosenthal, M.1    Ugele, B.2    Lipowsky, G.3    Kuster, H.4
  • 43
    • 33845326144 scopus 로고    scopus 로고
    • Screening for hypoglycemia at the bedside in the neonatal intensive care unit (NICU) with the Abbott PCx glucose meter
    • Balion C, Grey V, Ismaila A, Blatz S, Seidlitz W. Screening for hypoglycemia at the bedside in the neonatal intensive care unit (NICU) with the Abbott PCx glucose meter. BMC Pediatr. 2006;6:28.
    • (2006) BMC Pediatr , vol.6 , pp. 28
    • Balion, C.1    Grey, V.2    Ismaila, A.3    Blatz, S.4    Seidlitz, W.5
  • 44
    • 0033764601 scopus 로고    scopus 로고
    • Oxygen effects on glucose measurements with a reference analyzer and three handheld meters
    • Tang Z, Louie RF, Payes M, Chang KC, Kost GJ. Oxygen effects on glucose measurements with a reference analyzer and three handheld meters. Diabetes Technol Ther. 2000;2(3):349-62.
    • (2000) Diabetes Technol Ther , vol.2 , Issue.3 , pp. 349-362
    • Tang, Z.1    Louie, R.F.2    Payes, M.3    Chang, K.C.4    Kost, G.J.5
  • 45
    • 0026847242 scopus 로고
    • 1991 Federal Nursing Service Award recipient. The effect of increased atmospheric pressure on glucose reagent strip accuracy
    • Shafer MR. 1991 Federal Nursing Service Award recipient. The effect of increased atmospheric pressure on glucose reagent strip accuracy. Mil Med. 1992;157(4):162-5.
    • (1992) Mil Med , vol.157 , Issue.4 , pp. 162-165
    • Shafer, M.R.1
  • 47
    • 0030338950 scopus 로고    scopus 로고
    • Effects of pressure on whole blood glucose measurements using the Bayer Glucometer 4 blood glucose meter
    • Edge CJ, Grieve AP, Gibbins N, O'Sullivan F, Bryson P. Effects of pressure on whole blood glucose measurements using the Bayer Glucometer 4 blood glucose meter. Undersea Hyperb Med. 1996;23(4):221-4. (Pubitemid 126499602)
    • (1996) Undersea and Hyperbaric Medicine , vol.23 , Issue.4 , pp. 221-224
    • Edge, C.J.1    Grieve, A.P.2    Gibbins, N.3    O'Sullivan, F.4    Bryson, P.5
  • 48
    • 0035095386 scopus 로고    scopus 로고
    • Blood glucose meter performance under hyperbaric oxygen conditions
    • DOI 10.1016/S0009-8981(00)00418-6, PII S0009898100004186
    • Vote DA, Doar O, Moon RE, Toffaletti JG. Blood glucose meter performance under hyperbaric oxygen conditions. Clin Chim Acta. 2001;305(1-2):81-7. (Pubitemid 32203704)
    • (2001) Clinica Chimica Acta , vol.305 , Issue.1-2 , pp. 81-87
    • Vote, D.A.1    Doar, O.2    Moon, R.E.3    Toffaletti, J.G.4
  • 51
    • 0028346374 scopus 로고
    • 2 affect ExacTech meter glucose measurements
    • Kilpatrick ES, Rumley AG, Smith EA. Variations in sample pH and pO2 affect ExacTech meter glucose measurements. Diabet Med. 1994;11(5):506-9. (Pubitemid 24210273)
    • (1994) Diabetic Medicine , vol.11 , Issue.5 , pp. 506-509
    • Kilpatrick, E.S.1    Rumley, A.G.2    Smith, E.A.3
  • 52
    • 0028956578 scopus 로고
    • Effect of ambient temperature and humidity on performance of blood glucose meters
    • King JM, Eigenmann CA, Colagiuri S. Effect of ambient temperature and humidity on performance of blood glucose meters. Diabet Med. 1995;12(4):337-40.
    • (1995) Diabet Med , vol.12 , Issue.4 , pp. 337-340
    • King, J.M.1    Eigenmann, C.A.2    Colagiuri, S.3
  • 53
    • 0035515892 scopus 로고    scopus 로고
    • Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter
    • DOI 10.1258/0004563011901091
    • Nawawi H, Sazali BS, Kamaruzaman BH, Yazid TN, Jemain AA, Ismail F, Khalid BA. Effect of ambient temperature on analytical and clinical performance of a blood glucose monitoring system: Omnitest Sensor glucose meter. Ann Clin Biochem. 2001;38(Pt 6):676-83. (Pubitemid 33702274)
    • (2001) Annals of Clinical Biochemistry , vol.38 , Issue.6 , pp. 676-683
    • Nawawi, H.1    Sazali, B.S.2    Kamaruzaman, B.H.3    Yazid, T.N.4    Jemain, A.A.5    Ismail, F.6    Khalid, B.A.K.7
  • 54
    • 33846427722 scopus 로고    scopus 로고
    • Circadian rhythm of blood glucose values in critically ill patients
    • DOI 10.1097/01.CCM.0000253814.78836.43, PII 0000324620070200000012
    • Egi M, Bellomo R, Stachowski E, French CJ, Hart G, Stow P. Circadian rhythm of blood glucose values in critically ill patients. Crit Care Med. 2007;35(2): 416-21. (Pubitemid 46148530)
    • (2007) Critical Care Medicine , vol.35 , Issue.2 , pp. 416-421
    • Egi, M.1    Bellomo, R.2    Stachowski, E.3    French, C.J.4    Hart, G.5    Stow, P.6
  • 55
    • 0004644162 scopus 로고    scopus 로고
    • U.S. Department of Health and Human Services; Jul 18 [cited 2009 Jun 14]. Available from
    • U.S. Department of Health and Human Services; Food and Drug Administration. Medical device use-safety: incorporating human factors engineering into risk management. 2000 Jul 18 [cited 2009 Jun 14]. Available from: http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/ GuidanceDocuments/ucm094461.pdf.
    • (2000) Medical Device Use-safety: Incorporating Human Factors Engineering into Risk Management
  • 57
    • 81455154121 scopus 로고    scopus 로고
    • U.S. Department of Health and Human Services; Food and Drug Administration; Jan 24 [cited 2009 Aug 11]. Available from
    • U.S. Department of Health and Human Services; Food and Drug Administration; Center for Disease Control and Prevention. Current CLIA regulations. 2004 Jan 24 [cited 2009 Aug 11]. Available from: http://wwwn.cdc.gov/clia/regs/toc.aspx.
    • (2004) Current CLIA Regulations
  • 59
    • 0030066052 scopus 로고    scopus 로고
    • Consensus statement on self-monitoring of blood glucose
    • American Diabetes Association
    • American Diabetes Association. Consensus statement on self-monitoring of blood glucose. Diabetes Care. 1996;19:S62-6.
    • (1996) Diabetes Care , vol.19
  • 60
    • 0036092613 scopus 로고    scopus 로고
    • Instruments for self-monitoring of blood glucose: Comparisons of testing quality achieved by patients and a technician
    • Skeie S, Thue G, Nerhus K, Sandberg S. Instruments for self-monitoring of blood glucose: comparisons of testing quality achieved by patients and a technician. Clin Chem. 2002;48(7):994-1003. (Pubitemid 34680893)
    • (2002) Clinical Chemistry , vol.48 , Issue.7 , pp. 994-1003
    • Skeie, S.1    Thue, G.2    Nerhus, K.3    Sandberg, S.4
  • 62
    • 70349495829 scopus 로고    scopus 로고
    • Analytical interferences in point-of-care testing glucometers by icodextran and its metabolites: An overview
    • Flore KMJ, Delanghe JR. Analytical interferences in point-of-care testing glucometers by icodextran and its metabolites: an overview. Perit Dial Int. 2009;29(4):377-83.
    • (2009) Perit Dial Int , vol.29 , Issue.4 , pp. 377-383
    • Flore, K.M.J.1    Delanghe, J.R.2
  • 63
    • 23844476497 scopus 로고    scopus 로고
    • Comparison of the accuracy of the hemocue glucose analyzer with the Yellow Springs Instrument glucose oxidase analyzer, particularly in hypoglycemia
    • DOI 10.1530/eje.1.01952
    • Stork AD, Kemperman H, Erkelens DW, Veneman TF. Comparison of the accuracy of the HemoCue glucose analyzer with the Yellow Springs Instrument glucose oxidase analyzer, particularly in hypoglycemia. Eur J Endocrinol. 2005;153(2):275-81. (Pubitemid 41167485)
    • (2005) European Journal of Endocrinology , vol.153 , Issue.2 , pp. 275-281
    • Stork, A.D.M.1    Kemperman, H.2    Erkelens, D.W.3    Veneman, T.F.4
  • 64
    • 0038675123 scopus 로고    scopus 로고
    • Applying the right statistics: Analyses of measurement studies
    • DOI 10.1002/uog.122
    • Bland JM, Altman DG. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol. 2003;22(1):85-93. (Pubitemid 36886457)
    • (2003) Ultrasound in Obstetrics and Gynecology , vol.22 , Issue.1 , pp. 85-93
    • Bland, J.M.1    Altman, D.G.2
  • 65
    • 27644587693 scopus 로고    scopus 로고
    • The Original Clarke Error Grid Analysis (EGA)
    • DOI 10.1089/dia.2005.7.776
    • Clarke WL. The original Clarke error grid analysis (EGA). Diabetes Technol Ther. 2005;7(5):776-9. (Pubitemid 41572081)
    • (2005) Diabetes Technology and Therapeutics , vol.7 , Issue.5 , pp. 776-779
    • Clarke, W.L.1
  • 66
    • 0028120370 scopus 로고
    • The fiscal consequences of central vs distributed testing of glucose
    • Winkelman JW, Wybenga DR, Tanasijevic MJ. The fiscal consequences of central vs distributed testing of glucose. Clin Chem. 1994;40(8):1628-30. (Pubitemid 24241163)
    • (1994) Clinical Chemistry , vol.40 , Issue.8 , pp. 1628-1630
    • Winkelman, J.W.1    Wybenga, D.R.2    Tanasijevic, M.J.3
  • 68
    • 0027463199 scopus 로고
    • An assessment of the effect of haematocrit on the HemoCue blood glucose analyser
    • Wiener K. An assessment of the effect of haematocrit on the HemoCue blood glucose analyser. Ann Clin Biochem. 1993;30(Pt 1):90-3. (Pubitemid 23049427)
    • (1993) Annals of Clinical Biochemistry , vol.30 , Issue.1 , pp. 90-93
    • Wiener, K.1
  • 69
    • 19844365140 scopus 로고    scopus 로고
    • Agreement between bedside blood and plasma glucose measurement in the ICU setting
    • Finkielman JD, Oyen LJ, Afessa B. Agreement between bedside blood and plasma glucose measurement in the ICU setting. Chest. 2005;127(5):49-51.
    • (2005) Chest , vol.127 , Issue.5 , pp. 49-51
    • Finkielman, J.D.1    Oyen, L.J.2    Afessa, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.