-
1
-
-
0027370108
-
The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes Mellitus
-
The Diabetes Control and Complications Trial Research Group
-
The Diabetes Control and Complications Trial Research Group. The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes Mellitus. N Engl J Med 1993; 329: 977-86.
-
(1993)
N Engl J Med
, vol.329
, pp. 977-986
-
-
-
2
-
-
0032511566
-
Effect of intensive blood-glucose control with metformin on complications in overweight patients with type 2 diabetes (UKPDS 34). UK Prospective Diabetes Study (UKPDS) Group
-
Erratum in Lancet 1998; 352(9139): 1558
-
Effect of intensive blood-glucose control with metformin on complications in overweight patients with type 2 diabetes (UKPDS 34). UK Prospective Diabetes Study (UKPDS) Group. Lancet 1998; 352(9131): 854-65. Erratum in Lancet 1998; 352(9139): 1558.
-
(1998)
Lancet
, vol.352
, Issue.9131
, pp. 854-865
-
-
-
3
-
-
0032511583
-
Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group
-
Erratum in Lancet 1999; 354(9178): 602
-
Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33). UK Prospective Diabetes Study (UKPDS) Group. Lancet 1998; 352(9131): 837-53. Erratum in Lancet 1999; 354(9178): 602.
-
(1998)
Lancet
, vol.352
, Issue.9131
, pp. 837-853
-
-
-
4
-
-
78651338445
-
Standards of medical care in diabetes
-
Standards of medical care in diabetes. Diabetes Care 2011; 34: S11-S61.
-
(2011)
Diabetes Care
, vol.34
-
-
-
5
-
-
0020077396
-
Noninvasive glucose monitoring of the aqueous Humor of the eye: Part I. Measurement of very small optical rotations
-
Rabinovitch B, March WF, Adams RL. Noninvasive glucose monitoring of the aqueous Humor of the eye: part I. Measurement of very small optical rotations. Diabetes Care 1982; 5: 254-8.
-
(1982)
Diabetes Care
, vol.5
, pp. 254-258
-
-
Rabinovitch, B.1
March, W.F.2
Adams, R.L.3
-
6
-
-
0036021760
-
Continuous glucose monitoring: An overview of todaýs technologies and their clinical applications
-
Heinemann L, Koschinky T. Continuous glucose monitoring: an overview of todaýs technologies and their clinical applications. Int J Clin Pract Suppl 2002; 129: 75-9.
-
(2002)
Int J Clin Pract Suppl
, vol.129
, pp. 75-79
-
-
Heinemann, L.1
Koschinky, T.2
-
7
-
-
0242332246
-
Glucose sensors and alternate site testing-like phenomenon: Relationship between rapid blood glucose changes and glucose sensor signals
-
Koschinsky T, Jungheim K, Heinemann L. Glucose sensors and alternate site testing-like phenomenon: relationship between rapid blood glucose changes and glucose sensor signals. Diabetes Technol Ther 2003; 5: 829-42.
-
(2003)
Diabetes Technol Ther
, vol.5
, pp. 829-842
-
-
Koschinsky, T.1
Jungheim, K.2
Heinemann, L.3
-
8
-
-
0032836714
-
Subcutaneous glucose predicts plasma glucose independent of insulin: Implications for continuous monitoring
-
Rebrin K, Steil GM, van Antwerp WP, Mastrototaro JJ. Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol 1999; 277: E561-71.
-
(1999)
Am J Physiol
, vol.277
-
-
Rebrin, K.1
Steil, G.M.2
van Antwerp, W.P.3
Mastrototaro, J.J.4
-
9
-
-
0242269450
-
In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy
-
Maruo K, Tsurugi M, Tamura M, Ozaki Y. In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy. Appl Spectrosc 2003; 57: 1236-44.
-
(2003)
Appl Spectrosc
, vol.57
, pp. 1236-1244
-
-
Maruo, K.1
Tsurugi, M.2
Tamura, M.3
Ozaki, Y.4
-
10
-
-
18344404414
-
Human oral mucosa studies with varying blood glucose concentration by non-invasive ATR-FT-IRspectroscopy
-
Heise HM, Marbach R. Human oral mucosa studies with varying blood glucose concentration by non-invasive ATR-FT-IRspectroscopy. Cell Mol Biol (Noisy-le-grand) 1998; 44: 899-12.
-
(1998)
Cell Mol Biol (Noisy-le-grand)
, vol.44
, pp. 812-899
-
-
Heise, H.M.1
Marbach, R.2
-
11
-
-
6044275963
-
Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium
-
Khalil OS. Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium. Diabetes Technol Ther 2004; 6(5): 660-97.
-
(2004)
Diabetes Technol Ther
, vol.6
, Issue.5
, pp. 660-697
-
-
Khalil, O.S.1
-
12
-
-
0034045350
-
Non-invasive glucose measurement by monitoring of scattering coefficient during oral glucose tolerance tests. Non-Invasive Task Force
-
Heinemann L, Kramer U, Klotzer HM, et al. Non-invasive glucose measurement by monitoring of scattering coefficient during oral glucose tolerance tests. Non-Invasive Task Force, Diabetes Technol Ther 2000; 2(2): 211-20.
-
(2000)
Diabetes Technol Ther
, vol.2
, Issue.2
, pp. 211-220
-
-
Heinemann, L.1
Kramer, U.2
Klotzer, H.M.3
-
13
-
-
0038021219
-
Monitoring blood glucosevchanges in cutaneous tissue by temperature-modulated localized reflectance measurement
-
Yeh SJ, Hanna CF, Khalil OS. Monitoring blood glucosevchanges in cutaneous tissue by temperature-modulated localized reflectance measurement. Clin Chem 2003; 49: 924-34.
-
(2003)
Clin Chem
, vol.49
, pp. 924-934
-
-
Yeh, S.J.1
Hanna, C.F.2
Khalil, O.S.3
-
14
-
-
4344692198
-
Current problems and potential techniques in in-vivo glucose monitoring
-
Wickramasinghe Y, Yang Y, Spencer SA. Current problems and potential techniques in in-vivo glucose monitoring. J Fluorescence 2004; 14: 513-20.
-
(2004)
J Fluorescence
, vol.14
, pp. 513-520
-
-
Wickramasinghe, Y.1
Yang, Y.2
Spencer, S.A.3
-
15
-
-
0006919819
-
Overview of Non-Invasive Optical Glucose Monitoring Techniques; Overview of non-invasive fluid glucose measurement using optical techniques to maintain glucose control in diabetes mellitus
-
Avialable at, [Accessed on: 22/3/2206]
-
Waynant RW, Chenault VM. Overview of Non-Invasive Optical Glucose Monitoring Techniques; Overview of non-invasive fluid glucose measurement using optical techniques to maintain glucose control in diabetes mellitus. LEOS Newsletter 1998; Volume12, Number 2. Avialable at: http://photonicssociety.org/newsletters/ apr98/overview.htm [Accessed on: 22/3/2206].
-
(1998)
LEOS Newsletter
, vol.12
, Issue.2
-
-
Waynant, R.W.1
Chenault, V.M.2
-
16
-
-
0005789117
-
Measurement of the optical absorption coefficient of a liquid by use of a time-resolved photoacustic technique
-
Shen Y, Lu Z, Spiers S, MacKenzie HA, Ashton HS, Hanningan J. Measurement of the optical absorption coefficient of a liquid by use of a time-resolved photoacustic technique. Appl Opt 2000; 39: 4007-12.
-
(2000)
Appl Opt
, vol.39
, pp. 4007-4012
-
-
Shen, Y.1
Lu, Z.2
Spiers, S.3
McKenzie, H.A.4
Ashton, H.S.5
Hanningan, J.6
-
17
-
-
33847225922
-
Noninvasive continous glucose monitoring using photoacustic technologyresults from the first 62 subjects
-
Weiss RAM, Yegorchikov Y, Shusterman A, Raz I. Noninvasive continous glucose monitoring using photoacustic technologyresults from the first 62 subjects. Diabetes Technol Ther 2007; 9(1): 68-4.
-
(2007)
Diabetes Technol Ther
, vol.9
, Issue.1
, pp. 64-68
-
-
Weiss, R.A.M.1
Yegorchikov, Y.2
Shusterman, A.3
Raz, I.4
-
18
-
-
0033834696
-
Analysis of dielectric spectra of eukaryotic cells by computer modeling
-
Ermolina I, Polevaya Y, Feldman Y. Analysis of dielectric spectra of eukaryotic cells by computer modeling. Eur Biophys J 2000; 29: 141-5.
-
(2000)
Eur Biophys J
, vol.29
, pp. 141-145
-
-
Ermolina, I.1
Polevaya, Y.2
Feldman, Y.3
-
19
-
-
0033027086
-
Time domain dielectric spectroscopy study of human cells. Normal and malignant white blood cells
-
Polevaya Y, Ermolina I, Schlesinger M, Ginzburg BZ, Feldman Y. Time domain dielectric spectroscopy study of human cells. Normal and malignant white blood cells. Biochim Biophys Acta 1999; 1419: 257-71.
-
(1999)
Biochim Biophys Acta
, vol.1419
, pp. 257-271
-
-
Polevaya, Y.1
Ermolina, I.2
Schlesinger, M.3
Ginzburg, B.Z.4
Feldman, Y.5
-
21
-
-
0242357278
-
First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
-
Caduff AM, Hirt E, Feldman Y, Ali Z, Heinemann L. First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system. Biosens Bioelectron 2003; 19: 209-17.
-
(2003)
Biosens Bioelectron
, vol.19
, pp. 209-217
-
-
Caduff, A.M.1
Hirt, E.2
Feldman, Y.3
Ali, Z.4
Heinemann, L.5
-
22
-
-
0344873782
-
Study of a new electromagnetic sensor for glycaemia measurement: In vitro results on blood pig
-
Gourzi M, Rouane A, Guelaz R, Nadi M, Jaspard F. Study of a new electromagnetic sensor for glycaemia measurement: in vitro results on blood pig. J Med Eng Technol 2003; 27: 276-81.
-
(2003)
J Med Eng Technol
, vol.27
, pp. 276-281
-
-
Gourzi, M.1
Rouane, A.2
Guelaz, R.3
Nadi, M.4
Jaspard, F.5
-
23
-
-
0242654854
-
The correlation of the complex dielectric constant and blood glucose at low frequency
-
Park JH, Kim CS, Choi BC, Ham KY. The correlation of the complex dielectric constant and blood glucose at low frequency. Biosens Bioelectron 2003; 19: 321-24.
-
(2003)
Biosens Bioelectron
, vol.19
, pp. 321-324
-
-
Park, J.H.1
Kim, C.S.2
Choi, B.C.3
Ham, K.Y.4
-
25
-
-
33645285027
-
Impact of environmental temperature on skin thickness and microvascular blood flow in diabetic and non-diabetic subjects
-
Forst T, Caduff A, Talary M, et al. Impact of environmental temperature on skin thickness and microvascular blood flow in diabetic and non-diabetic subjects. Diabetes Technol Therap 2006; 81(1): 94-101.
-
(2006)
Diabetes Technol Therap
, vol.81
, Issue.1
, pp. 94-101
-
-
Forst, T.1
Caduff, A.2
Talary, M.3
-
26
-
-
12344275405
-
Non-invasive glycaemia blood measurement by electromagnetic sensor: Study in static and dynamic blood circulation
-
Gourzi M, Rouane A, Guelaz R, Alavi MS, McHugh MB, Nadi M. Non-invasive glycaemia blood measurement by electromagnetic sensor: study in static and dynamic blood circulation. J Med Eng Technol 2005; 29: 22-6.
-
(2005)
J Med Eng Technol
, vol.29
, pp. 22-26
-
-
Gourzi, M.1
Rouane, A.2
Guelaz, R.3
Alavi, M.S.4
McHugh, M.B.5
Nadi, M.6
-
27
-
-
0034613001
-
A dielectric analysis of liquid and glassy solid glucose/water solutions
-
Moran GR, Jeffrey KR, Thomas JM, Stevens JR. A dielectric analysis of liquid and glassy solid glucose/water solutions. Carbohydr Res 2000; 328: 573-84.
-
(2000)
Carbohydr Res
, vol.328
, pp. 573-584
-
-
Moran, G.R.1
Jeffrey, K.R.2
Thomas, J.M.3
Stevens, J.R.4
-
28
-
-
12444301362
-
Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum
-
Gebhart S, Faupel M, Fowler R, et al. Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum. Diabetes Technol Ther 2003; 5(2): 159-66.
-
(2003)
Diabetes Technol Ther
, vol.5
, Issue.2
, pp. 159-166
-
-
Gebhart, S.1
Faupel, M.2
Fowler, R.3
-
29
-
-
0033361244
-
Application of the mixtures of experts algorithm for signal processing in a noninvasive glucose monitoring system
-
Kurnik RT, Oliver JJ, Waterhouse SR, Dunn T, Jayalakshmi Y, Lesho M. Application of the mixtures of experts algorithm for signal processing in a noninvasive glucose monitoring system. Sens Actuators B Chem 1999; 60: 19-26.
-
(1999)
Sens Actuators B Chem
, vol.60
, pp. 19-26
-
-
Kurnik, R.T.1
Oliver, J.J.2
Waterhouse, S.R.3
Dunn, T.4
Jayalakshmi, Y.5
Lesho, M.6
-
30
-
-
0035345431
-
Detection of hypoglycemia with the GlucoWatch biorapher
-
Pitzer KR, Desai S, Dunn T, Edelman S, Jayalakshmi Y, Kenedy J. Detection of hypoglycemia with the GlucoWatch biorapher. Diabetes Care 2001; 24: 881-5.
-
(2001)
Diabetes Care
, vol.24
, pp. 881-885
-
-
Pitzer, K.R.1
Desai, S.2
Dunn, T.3
Edelman, S.4
Jayalakshmi, Y.5
Kenedy, J.6
-
31
-
-
1442275324
-
Accuracy of the GlucoWatchG2 Biographer and the Continuous Glucose Monitoring System During Hypoglycemia Experience of the Diabetes Research in Children Network
-
The diabetes research in children network study group (DIRECNET)
-
The diabetes research in children network study group (DIRECNET). Accuracy of the GlucoWatchG2 Biographer and the Continuous Glucose Monitoring System During Hypoglycemia Experience of the Diabetes Research in Children Network. Diabetes Care 2004; 27: 722-6.
-
(2004)
Diabetes Care
, vol.27
, pp. 722-726
-
-
-
32
-
-
33645291237
-
Initial clinical testing of a holographic non-invasive contact lens glucose sensor
-
Domschke A, March WF, Kabilan S, Lowe C. Initial clinical testing of a holographic non-invasive contact lens glucose sensor. Diabetes Technol Ther 2006; 1: 89-93.
-
(2006)
Diabetes Technol Ther
, vol.1
, pp. 89-93
-
-
Domschke, A.1
March, W.F.2
Kabilan, S.3
Lowe, C.4
-
33
-
-
13844275498
-
A glucose-sensing contact lens: From bench top to patient
-
Badugu R, Lakowicz JR, Geddes CD. A glucose-sensing contact lens: from bench top to patient. Curr Opin Biotechol 2005; 16: 100-7.
-
(2005)
Curr Opin Biotechol
, vol.16
, pp. 100-107
-
-
Badugu, R.1
Lakowicz, J.R.2
Geddes, C.D.3
-
35
-
-
0347899347
-
A glucose sensing contact lens: A non-invasive technique for continuous physiological glucose monitoring
-
Badugu R, Lakowicz JR, Geddes CD. A glucose sensing contact lens: a non-invasive technique for continuous physiological glucose monitoring. J Fluores 2003; 13: 371-4.
-
(2003)
J Fluores
, vol.13
, pp. 371-374
-
-
Badugu, R.1
Lakowicz, J.R.2
Geddes, C.D.3
-
37
-
-
78650172137
-
Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
-
Chu MX, Miyajima K, Takahashi D, et al. Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment. Talanta 2011; 83(3): 960-5.
-
(2011)
Talanta
, vol.83
, Issue.3
, pp. 960-965
-
-
Chu, M.X.1
Miyajima, K.2
Takahashi, D.3
-
38
-
-
0038021219
-
Monitoring blood glucose changes in cutaneous tissue by temperature-modulated localized reflectance measurements
-
Yeh SJ, HannaCF, KhalilOS. Monitoring blood glucose changes in cutaneous tissue by temperature-modulated localized reflectance measurements. Clin Chem 2003; 49: 924-34.
-
(2003)
Clin Chem
, vol.49
, pp. 924-934
-
-
Yeh, S.J.1
Hanna, C.F.2
Khalil, O.S.3
-
39
-
-
0344034169
-
Influence of epidermal thickness, pigmentation and redness on skin autofluorescence
-
Sandby-Møller J, Poulsen T, Wulf HC. Influence of epidermal thickness, pigmentation and redness on skin autofluorescence. Photochem Photobiol 2003; 77: 616-20.
-
(2003)
Photochem Photobiol
, vol.77
, pp. 616-620
-
-
Sandby-Møller, J.1
Poulsen, T.2
Wulf, H.C.3
-
40
-
-
0033968170
-
Prospects for in vivo Raman spectroscopy
-
Hanlon EB, Manoharan R, Koo T-W, Shafer KE, Motz JT. Prospects for in vivo Raman spectroscopy. Phys Med Biol 2000; 45:R1-R59.
-
(2000)
Phys Med Biol
, vol.45
-
-
Hanlon, E.B.1
Manoharan, R.2
Koo, T-W.3
Shafer, K.E.4
Motz, J.T.5
-
41
-
-
0033140260
-
Laser-based measurement of glucose in the ocular aqueous humor: An efficacious portal for determination of serum glucose levels
-
Steffes PG. Laser-based measurement of glucose in the ocular aqueous humor: an efficacious portal for determination of serum glucose levels. Diabetes Technol Ther 1999; 1(2): 129-33.
-
(1999)
Diabetes Technol Ther
, vol.1
, Issue.2
, pp. 129-133
-
-
Steffes, P.G.1
-
43
-
-
0038649993
-
Combined in vivo confocal Raman spectroscopy and confocal microscopy of human skin
-
Caspers PJ, Lucassen GW, Puppels GJ. Combined in vivo confocal Raman spectroscopy and confocal microscopy of human skin. Biophys J 2003; 85: 572-80.
-
(2003)
Biophys J
, vol.85
, pp. 572-580
-
-
Caspers, P.J.1
Lucassen, G.W.2
Puppels, G.J.3
-
44
-
-
77950566953
-
Requirements for calibration in noninvasive glucose monitoring by Raman spectroscopy
-
Lipson J, Bernhardt J, Block U, et al. Requirements for calibration in noninvasive glucose monitoring by Raman spectroscopy. J Diabetes Sci Technol 2009; 3(2): 233-41.
-
(2009)
J Diabetes Sci Technol
, vol.3
, Issue.2
, pp. 233-241
-
-
Lipson, J.1
Bernhardt, J.2
Block, U.3
-
45
-
-
33644821960
-
At-line monitoring of ammonium, glucose, methyl oleate and biomass in a complex antibiotic fermentation process using attenuated total reflectance-midinfrared (ATR-MIR) spectroscopy
-
Roychoudhury P, Harvey LM, McNeil B. At-line monitoring of ammonium, glucose, methyl oleate and biomass in a complex antibiotic fermentation process using attenuated total reflectance-midinfrared (ATR-MIR) spectroscopy. Anal Chim Acta 2006; 561: 218-24.
-
(2006)
Anal Chim Acta
, vol.561
, pp. 218-224
-
-
Roychoudhury, P.1
Harvey, L.M.2
McNeil, B.3
-
46
-
-
0032995738
-
Spectroscopic and clinical aspects of non-invasive glucose measurements
-
Khalil OS. Spectroscopic and clinical aspects of non-invasive glucose measurements. Clin Chem 1999; 45: 165-77.
-
(1999)
Clin Chem
, vol.45
, pp. 165-177
-
-
Khalil, O.S.1
-
47
-
-
0030025192
-
Non-invasive monitoring of metabolites using near read infrarred spectroscopy: State of the art
-
Arnold MA. Non-invasive monitoring of metabolites using near read infrarred spectroscopy: state of the art. Horm Metab Res 1996; 7: 46-9.
-
(1996)
Horm Metab Res
, vol.7
, pp. 46-49
-
-
Arnold, M.A.1
-
48
-
-
0030073462
-
Simultaneous measurements of glucose, glutamine, ammonia, lactate and glutamate in aqueous solutions by near-infrared spectroscopy
-
Chung H, Arnold MA, Rhiel M, Murhammer DW. Simultaneous measurements of glucose, glutamine, ammonia, lactate and glutamate in aqueous solutions by near-infrared spectroscopy. Appl Spectrosc 1996; 50: 270-6.
-
(1996)
Appl Spectrosc
, vol.50
, pp. 270-276
-
-
Chung, H.1
Arnold, M.A.2
Rhiel, M.3
Murhammer, D.W.4
-
49
-
-
0032078931
-
Adaptive calibration scheme for quantification of nutrients and byproducts in insect cell bioreactors by near infrared spectroscopy
-
Riley MR, Arnold MA, Murhammer DW. Adaptive calibration scheme for quantification of nutrients and byproducts in insect cell bioreactors by near infrared spectroscopy. Biotechnol Prog 1988; 14: 527-33.
-
(1988)
Biotechnol Prog
, vol.14
, pp. 527-533
-
-
Riley, M.R.1
Arnold, M.A.2
Murhammer, D.W.3
-
50
-
-
0025072502
-
Determination of physiological levels of glucose in an aqueous matrix with digitally filtered Fourier transform near-infrared spectra
-
Arnold MA, Small GW. Determination of physiological levels of glucose in an aqueous matrix with digitally filtered Fourier transform near-infrared spectra. Anal Chem 1990; 62: 1457-64.
-
(1990)
Anal Chem
, vol.62
, pp. 1457-1464
-
-
Arnold, M.A.1
Small, G.W.2
-
51
-
-
0031223698
-
Multivariate calibration models based on the direct analysis of near-infrared single beam spectra
-
Lu G, Zhou X, Arnold MA, Small GW. Multivariate calibration models based on the direct analysis of near-infrared single beam spectra. Appl Spectrosc 1997; 51: 1330-9.
-
(1997)
Appl Spectrosc
, vol.51
, pp. 1330-1339
-
-
Lu, G.1
Zhou, X.2
Arnold, M.A.3
Small, G.W.4
-
52
-
-
0031246792
-
Variable selection in multivariate calibration of spectroscopic glucose sensor
-
McShane MJ, Coté GL, Spiegelman C. Variable selection in multivariate calibration of spectroscopic glucose sensor. Appl Spectrosc 1997; 51: 1559-64.
-
(1997)
Appl Spectrosc
, vol.51
, pp. 1559-1564
-
-
McShane, M.J.1
Coté, G.L.2
Spiegelman, C.3
-
53
-
-
0033907204
-
Effect of sample complexity on quantification of analytes in aqueous samples by near infrared spectroscopy
-
Riley MR, Arnold MA, Murhammer DW. Effect of sample complexity on quantification of analytes in aqueous samples by near infrared spectroscopy. Appl Spectrosc 2000; 54: 255-61.
-
(2000)
Appl Spectrosc
, vol.54
, pp. 255-261
-
-
Riley, M.R.1
Arnold, M.A.2
Murhammer, D.W.3
-
54
-
-
0024593985
-
Blood glucose measurement by infrared spectroscopy
-
Zeller H, Novak P, Landgraf R. Blood glucose measurement by infrared spectroscopy. Int J Artif Organs 1989; 12(2): 129-35.
-
(1989)
Int J Artif Organs
, vol.12
, Issue.2
, pp. 129-135
-
-
Zeller, H.1
Novak, P.2
Landgraf, R.3
-
55
-
-
0006247823
-
Enhancing calibration models for non-invasive nearinfrared specroscopical blood glucose determination
-
Fischbacher C, Jagemann KU, Danzer K, Muller UA, Papenkordt L, Schuler J. Enhancing calibration models for non-invasive nearinfrared specroscopical blood glucose determination. J Anal Chem 1997; 359: 78-82.
-
(1997)
J Anal Chem
, vol.359
, pp. 78-82
-
-
Fischbacher, C.1
Jagemann, K.U.2
Danzer, K.3
Muller, U.A.4
Papenkordt, L.5
Schuler, J.6
-
56
-
-
0034014343
-
Near-infrared reflectance spectroscopy for non-invasive monitoring of metabolites
-
Heise HM, Bittner A, Marbach R. Near-infrared reflectance spectroscopy for non-invasive monitoring of metabolites. Clin Chem Lab Med 2000; 38(2): 137-45.
-
(2000)
Clin Chem Lab Med
, vol.38
, Issue.2
, pp. 137-145
-
-
Heise, H.M.1
Bittner, A.2
Marbach, R.3
-
57
-
-
0001337773
-
Measurement of glucose in water with first-overtone near-infrared spectra
-
Hazen KH, Arnold MA, Small GW. Measurement of glucose in water with first-overtone near-infrared spectra. Appl Spectrosc 1998; 52: 1597-05.
-
(1998)
Appl Spectrosc
, vol.52
, pp. 1505-1597
-
-
Hazen, K.H.1
Arnold, M.A.2
Small, G.W.3
-
58
-
-
0031864724
-
On behalf of of the Noninvasive task force (NITF), Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors
-
Heinmann L, Schmelzeisen-Redeker G. On behalf of of the Noninvasive task force (NITF), Non-invasive continuous glucose monitoring in Type I diabetic patients with optical glucose sensors. Diabetologia 1998; 41: 848-54.
-
(1998)
Diabetologia
, vol.41
, pp. 848-854
-
-
Heinmann, L.1
Schmelzeisen-Redeker, G.2
-
59
-
-
33845354284
-
Pulse glucometry: A new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometry
-
Yamakoshi K, Yamakoshi Y. Pulse glucometry: A new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometry. J Biomed Opt 2006; 11(5): 054028.
-
(2006)
J Biomed Opt
, vol.11
, Issue.5
, pp. 054028
-
-
Yamakoshi, K.1
Yamakoshi, Y.2
-
60
-
-
54049128189
-
Noninvasive blood glucose monitoring using the optical signal of pulsatile microcirculation: A pilot study in subjects with diabetes
-
Chen CS, Wang KK, Jan MY, et al. Noninvasive blood glucose monitoring using the optical signal of pulsatile microcirculation: a pilot study in subjects with diabetes. J Diabetes Complications 2008; 22(6): 371-6.
-
(2008)
J Diabetes Complications
, vol.22
, Issue.6
, pp. 371-376
-
-
Chen, C.S.1
Wang, K.K.2
Jan, M.Y.3
-
61
-
-
0016230635
-
Arterial pulse waves and velocity and systolic time intervals in diabetic subjects
-
Pillsbury HC, Hung W, Kyle MC, Freis ED. Arterial pulse waves and velocity and systolic time intervals in diabetic subjects. Am Heart J 1974; 87: 783-90.
-
(1974)
Am Heart J
, vol.87
, pp. 783-790
-
-
Pillsbury, H.C.1
Hung, W.2
Kyle, M.C.3
Freis, E.D.4
-
62
-
-
0027049259
-
Comparative effects of diabetes mellitus and hypertension on physical properties of human large arteries
-
Megnien JL, Simon A, Valensi P. Comparative effects of diabetes mellitus and hypertension on physical properties of human large arteries. J Am Coll Cardiol 1992; 20: 1562-8.
-
(1992)
J Am Coll Cardiol
, vol.20
, pp. 1562-1568
-
-
Megnien, J.L.1
Simon, A.2
Valensi, P.3
-
63
-
-
0023952596
-
Increased arterial wall stiffness and thickness in medium-sized arteries in patients with insulindependent diabetes mellitus
-
Christensen T, Nubauer B. Increased arterial wall stiffness and thickness in medium-sized arteries in patients with insulindependent diabetes mellitus. Acta Radiol 1988; 29: 299-02.
-
(1988)
Acta Radiol
, vol.29
, pp. 202-299
-
-
Christensen, T.1
Nubauer, B.2
-
64
-
-
84970101033
-
Arterial wall stiffness in insulindependent diabetes mellitus: An in vivo study
-
Christensen T and Neubauer B. Arterial wall stiffness in insulindependent diabetes mellitus: an in vivo study. Acta Radiol 1987; 28: 207-8.
-
(1987)
Acta Radiol
, vol.28
, pp. 207-208
-
-
Christensen, T.1
Neubauer, B.2
-
65
-
-
0022542057
-
Aortic stiffness in insulin-dependent diabetics: An echocardiographic study
-
Thordarson H, Thorgeirsson G, Helgason T. Aortic stiffness in insulin-dependent diabetics: an echocardiographic study. Diabetes Med 1986; 3: 449-54.
-
(1986)
Diabetes Med
, vol.3
, pp. 449-454
-
-
Thordarson, H.1
Thorgeirsson, G.2
Helgason, T.3
-
66
-
-
0000811193
-
The pulse wave velocity as an early indicator of atherosclerosis in diabetic subjects
-
Woolam GL, Schnur PL, Vallbona C, Hoff HE. The pulse wave velocity as an early indicator of atherosclerosis in diabetic subjects. Circulation 1962; 25: 533-9.
-
(1962)
Circulation
, vol.25
, pp. 533-539
-
-
Woolam, G.L.1
Schnur, P.L.2
Vallbona, C.3
Hoff, H.E.4
-
68
-
-
0027508552
-
Vascular abnormalities in noninsulin dependent diabetes mellitus identified by arterial waveform analysis
-
McVeigh G, Brennan G, Hayes R. Vascular abnormalities in noninsulin dependent diabetes mellitus identified by arterial waveform analysis. Am J Med 1993; 95: 424-30.
-
(1993)
Am J Med
, vol.95
, pp. 424-430
-
-
McVeigh, G.1
Brennan, G.2
Hayes, R.3
-
69
-
-
0024419033
-
Increased aortic stiffness in patients with type I (insulin decedent) diabetes mellitus
-
Oxlund H, Rasmussen LM, Andreassen TT, Heickendorf L. Increased aortic stiffness in patients with type I (insulin decedent) diabetes mellitus. Diabetologia 1989; 32: 748-52.
-
(1989)
Diabetologia
, vol.32
, pp. 748-752
-
-
Oxlund, H.1
Rasmussen, L.M.2
Andreassen, T.T.3
Heickendorf, L.4
-
70
-
-
85047676110
-
Diminished arterial elasticity in diabetes: Association with fluorescent advance glycosylation end products in collagen
-
Airaksinen, KE, Salmela PI, Linnaluoto MK. Diminished arterial elasticity in diabetes: association with fluorescent advance glycosylation end products in collagen, Cardiovasc Res 1993; 27: 942-45.
-
(1993)
Cardiovasc Res
, vol.27
, pp. 942-945
-
-
Airaksinen, K.E.1
Salmela, P.I.2
Linnaluoto, M.K.3
-
71
-
-
0028913094
-
Non-insulin-dependent diabetes mellitus and fasting glucose and insulin concentrations are associated with arterial stiffness indexes, the ARIC study
-
Salomaa V, Riley W, Kark JD. Non-insulin-dependent diabetes mellitus and fasting glucose and insulin concentrations are associated with arterial stiffness indexes, the ARIC study. Circulation 1995; 91: 1432-43.
-
(1995)
Circulation
, vol.91
, pp. 1432-1443
-
-
Salomaa, V.1
Riley, W.2
Kark, J.D.3
-
72
-
-
64449088955
-
Non-invasive glucose monitoring in patients with type 1 diabetes: A multisensory system combining sensors for dielectric and optical characterization of skin
-
Caduff A, Talary M, Mueller M, et al. Non-invasive glucose monitoring in patients with type 1 diabetes: a multisensory system combining sensors for dielectric and optical characterization of skin. Biosens Bioelectron 2009; 24: 2778-84.
-
(2009)
Biosens Bioelectron
, vol.24
, pp. 2778-2784
-
-
Caduff, A.1
Talary, M.2
Mueller, M.3
-
73
-
-
0030786579
-
Non-invasive blood glucose monitoring by means of near infrared spectroscopy: Methods for improving the reliability of the calibration models
-
Müller UA, Mertes B, Fischbaucher C, Jageman KU, Danzer K. Non-invasive blood glucose monitoring by means of near infrared spectroscopy: methods for improving the reliability of the calibration models. Int J Artif Organs 1997; 20: 285-90.
-
(1997)
Int J Artif Organs
, vol.20
, pp. 285-290
-
-
Müller, U.A.1
Mertes, B.2
Fischbaucher, C.3
Jageman, K.U.4
Danzer, K.5
-
74
-
-
52749091945
-
Evidence for interindividual heterogeneity in the glucose gradient across the human red blood cell membrane and its relationship to hemoglobin glycation
-
Khera PK, Joiner CH, Carruthers A, et al. Evidence for interindividual heterogeneity in the glucose gradient across the human red blood cell membrane and its relationship to hemoglobin glycation. Diabetes 2008; 57: 2445-52.
-
(2008)
Diabetes
, vol.57
, pp. 2445-2452
-
-
Khera, P.K.1
Joiner, C.H.2
Carruthers, A.3
-
75
-
-
0033366694
-
Transcutaneous glucose measurement using nearinfrared spectroscopy during hypoglycemia
-
Gabriely I, Wozniak R, Mevorach M, Kaplan J, Aharon K, Shamoon H. Transcutaneous glucose measurement using nearinfrared spectroscopy during hypoglycemia. Diabetes Care 1999; 22: 2026-32.
-
(1999)
Diabetes Care
, vol.22
, pp. 2026-2032
-
-
Gabriely, I.1
Wozniak, R.2
Mevorach, M.3
Kaplan, J.4
Aharon, K.5
Shamoon, H.6
-
76
-
-
0029888293
-
Impaired peripheral vasomotion in diabetes
-
Stansberry KB, Shapiro SA, Hill MA, McNitt PM, Meyer MD, Vinik AI. Impaired peripheral vasomotion in diabetes. Diabetes Care 2006; 19: 715-21.
-
(2006)
Diabetes Care
, vol.19
, pp. 715-721
-
-
Stansberry, K.B.1
Shapiro, S.A.2
Hill, M.A.3
McNitt, P.M.4
Meyer, M.D.5
Vinik, A.I.6
-
77
-
-
0031873445
-
The impact of contralateral cooling of skin capillary blood cell velocity in patients with diabetes mellitus
-
Haak E, Haak T, Grozinger Y, Krebs G, Usadel KH, Kusterer K. The impact of contralateral cooling of skin capillary blood cell velocity in patients with diabetes mellitus. J Vasc Res 1998; 35: 245-49.
-
(1998)
J Vasc Res
, vol.35
, pp. 245-249
-
-
Haak, E.1
Haak, T.2
Grozinger, Y.3
Krebs, G.4
Usadel, K.H.5
Kusterer, K.6
-
78
-
-
0032485927
-
Acute hyperglycemia attenuates endothelium-dependent vasodilation in humans in vivo
-
Williams SB, Goldfine AB, Timimi FK, et al. Acute hyperglycemia attenuates endothelium-dependent vasodilation in humans in vivo. Circulation 1998; 97: 1695-01.
-
(1998)
Circulation
, vol.97
, pp. 1601-1695
-
-
Williams, S.B.1
Goldfine, A.B.2
Timimi, F.K.3
-
79
-
-
0031920445
-
Insulin-induced vasodilatation: Physiology or pharmacology
-
Yki-Jarvinen H, Utriainen T. Insulin-induced vasodilatation: physiology or pharmacology. Diabetologia 1998; 41: 369-79.
-
(1998)
Diabetologia
, vol.41
, pp. 369-379
-
-
Yki-Jarvinen, H.1
Utriainen, T.2
-
80
-
-
0036354936
-
Acute hyperglycemia and hyperinsulinemia enhance vasodilatation in Type-1 diabetes mellitus without increasing capillary permeability and inducing endothelial dysfunction
-
Oomen PHN, Kant GD, Dullaart RPF, Reitsma WD, Smit AJ. Acute hyperglycemia and hyperinsulinemia enhance vasodilatation in Type-1 diabetes mellitus without increasing capillary permeability and inducing endothelial dysfunction. Microvasc Res 2002; 63: 1-9.
-
(2002)
Microvasc Res
, vol.63
, pp. 1-9
-
-
Oomen, P.H.N.1
Kant, G.D.2
Dullaart, R.P.F.3
Reitsma, W.D.4
Smit, A.J.5
-
81
-
-
0036525878
-
Properties of erythrocyte light refraction in diabetic patients
-
Mazarevica G, Freivalds T, Jurka A. Properties of erythrocyte light refraction in diabetic patients. J Biomed Opt 2002; 7: 244-47.
-
(2002)
J Biomed Opt
, vol.7
, pp. 244-247
-
-
Mazarevica, G.1
Freivalds, T.2
Jurka, A.3
-
82
-
-
0035671333
-
Image analysis for the detection of increased erythrocyte, leukocyte and platelet adhesiveness/ aggregation in the peripheral blood of patients with diabetes mellitus
-
Fusman R, Rotstein R, Elishkewich K, et al. Image analysis for the detection of increased erythrocyte, leukocyte and platelet adhesiveness/ aggregation in the peripheral blood of patients with diabetes mellitus. Acta Diabetol 2001; 38: 129-34.
-
(2001)
Acta Diabetol
, vol.38
, pp. 129-134
-
-
Fusman, R.1
Rotstein, R.2
Elishkewich, K.3
-
83
-
-
79955470690
-
Characteristics of a multisensor system for non invasive glucose monitoring with external validation and prospective evaluation
-
[Epub ahead of print]
-
Caduff A, Mueller M, Megej A, et al. Characteristics of a multisensor system for non invasive glucose monitoring with external validation and prospective evaluation. Biosens Bioelectron 2011, [Epub ahead of print].
-
(2011)
Biosens Bioelectron
-
-
Caduff, A.1
Mueller, M.2
Megej, A.3
-
84
-
-
78349237849
-
Noninvasive glucose monitoring: Increasing accuracy by combination of multi-technology and multi-sensors
-
Harman-Boehm I, Gal A, Raykhman AM, Naidis E, Mayzel Y. Noninvasive glucose monitoring: increasing accuracy by combination of multi-technology and multi-sensors. J Diabetes Sci Technol 2010; 4(3): 583-95.
-
(2010)
J Diabetes Sci Technol
, vol.4
, Issue.3
, pp. 583-595
-
-
Harman-Boehm, I.1
Gal, A.2
Raykhman, A.M.3
Naidis, E.4
Mayzel, Y.5
-
85
-
-
79957656823
-
Non-invasive measurement of plasma glucose from exhaled breath in healthy and type 1 diabetic subjects
-
Epub 2011 Apr 5
-
Minh TD, Oliver SR, Ngo J, et al. Non-invasive measurement of plasma glucose from exhaled breath in healthy and type 1 diabetic subjects. Am J Physiol Endocrinol Metab 2011 300(6): E1166-75. Epub 2011 Apr 5.
-
(2011)
Am J Physiol Endocrinol Metab
, vol.300
, Issue.6
-
-
Minh, T.D.1
Oliver, S.R.2
Ngo, J.3
|