The accuracy of point-of-care glucose measurements

Author keywords

Blood glucose; Glucose error; Glucose measurement; Hypoglycemia; Laboratory; Point of care device

Indexed keywords

GLUCOSE; GLUCOSE 6 PHOSPHATE; GLUCOSE 6 PHOSPHATE DEHYDROGENASE; GLUCOSE DEHYDROGENASE; GLUCOSE OXIDASE; BIOLOGICAL MARKER;

EID: 84865124284     PISSN: None     EISSN: 19322968     Source Type: Journal    
DOI: 10.1177/193229681200600228     Document Type: Review
Times cited : (110)

References (83)
  • 2
    • 0036177713 scopus 로고    scopus 로고
    • Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetyes mellitus
    • Sacks DB, Bruns DE, Goldstein DE, MacLaren NK, McDonald JM, Parrott M. Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clin Chem. 2002;48(3):436-72. (Pubitemid 34174577)
    • (2002) Clinical Chemistry , vol.48 , Issue.3 , pp. 436-472
    • Sacks, D.B.1    Bruns, D.E.2    Goldstein, D.E.3    Maclaren, N.K.4    McDonald, J.M.5    Parrott, M.6
  • 3
    • 70350026568 scopus 로고    scopus 로고
    • Tight glycemic control and point-of-care testing
    • Alter D, Deines G. Tight glycemic control and point-of-care testing. Clin Lab Med. 2009;29(3):511-22.
    • (2009) Clin Lab Med , vol.29 , Issue.3 , pp. 511-522
    • Alter, D.1    Deines, G.2
  • 4
    • 67650495754 scopus 로고    scopus 로고
    • Glucose control in the intensive care unit
    • Fahy BG, Sheehy AM, Coursin DB. Glucose control in the intensive care unit. Crit Care Med. 2009;37(5):1769-76.
    • (2009) Crit Care Med , vol.37 , Issue.5 , pp. 1769-1776
    • Fahy, B.G.1    Sheehy, A.M.2    Coursin, D.B.3
  • 5
    • 77249140803 scopus 로고    scopus 로고
    • Challenges to glycemic measurement in the perioperative and critically ill patient: A review
    • Pitkin AD, Rice MJ. Challenges to glycemic measurement in the perioperative and critically ill patient: a review. J Diabetes Sci Technol. 2009;3(6):1270-81.
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.6 , pp. 1270-1281
    • Pitkin, A.D.1    Rice, M.J.2
  • 8
    • 0024323983 scopus 로고
    • + and NADH
    • DOI 10.1016/0003-2697(89)90149-8
    • Bergel A, Souppe J, Comtat M. Enzymatic amplification for spectro- photometric and electrochemical assays of NAD+ and NADH. Anal Biochem. 1989;179(2):382-8. (Pubitemid 19153853)
    • (1989) Analytical Biochemistry , vol.179 , Issue.2 , pp. 382-388
    • Bergel, A.1    Souppe, J.2    Comtat, M.3
  • 9
    • 0033764601 scopus 로고    scopus 로고
    • Oxygen efects on glucose measurements with a reference analyzer and three handheld meters
    • Tang Z, Louie RF, Payes M, Chang KC, Kost GJ. Oxygen efects on glucose measurements with a reference analyzer and three handheld meters. Diabetes Technol Ther. 2000;2(3):349-62.
    • (2000) Diabetes Technol Ther , vol.2 , Issue.3 , pp. 349-362
    • Tang, Z.1    Louie, R.F.2    Payes, M.3    Chang, K.C.4    Kost, G.J.5
  • 10
    • 0034128795 scopus 로고    scopus 로고
    • Effects of pH on glucose measurements with handheld glucose meters and a portable glucose analyzer for point-of-care testing
    • Tang Z, Du X, Louie RF, Kost GJ. Effects of pH on glucose measurements with handheld glucose meters and a portable glucose analyzer for point-of-care testing. Arch Pathol Lab Med. 2000;124(4):577-82. (Pubitemid 30210991)
    • (2000) Archives of Pathology and Laboratory Medicine , vol.124 , Issue.4 , pp. 577-582
    • Tang, Z.1    Du, X.2    Louie, R.F.3    Kost, G.J.4
  • 11
    • 0035023293 scopus 로고    scopus 로고
    • Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing
    • Tang Z, Louie RF, Lee JH, Lee DM, Miller EE, Kost GJ. Oxygen efects on glucose dehydrogenase- and oxidase-based test strips for point-of-care testing. Crit Care Med. 2001;29(5):1062-70. (Pubitemid 32424364)
    • (2001) Critical Care Medicine , vol.29 , Issue.5 , pp. 1062-1070
    • Tang, Z.1    Louie, R.F.2    Lee, J.H.3    Lee, D.M.4    Miller, E.E.5    Kost, G.J.6
  • 12
    • 77951010226 scopus 로고    scopus 로고
    • Glucose measurement in the operating room: More complicated than it seems
    • Rice MJ, Pitkin AD, Coursin DB. Glucose measurement in the operating room: more complicated than it seems. Anesth Analg. 2010;110(4):1056-65.
    • (2010) Anesth Analg , vol.110 , Issue.4 , pp. 1056-1065
    • Rice, M.J.1    Pitkin, A.D.2    Coursin, D.B.3
  • 13
    • 0032878556 scopus 로고    scopus 로고
    • Newer portable glucose meters - Analytical improvement compared with previous generation devices?
    • Weitgasser R, Gappmeyer B, Pichler M. Newer portable glucose meters - analytical improvement compared with previous generation devices. Clin Chem. 1999;45(10):1821-5. (Pubitemid 29477341)
    • (1999) Clinical Chemistry , vol.45 , Issue.10 , pp. 1821-1825
    • Weitgasser, R.1    Gappmayer, B.2    Pichler, M.3
  • 15
    • 0034005547 scopus 로고    scopus 로고
    • Effects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer
    • Tang Z, Du X, Louie RF, Kost GJ. Efects of drugs on glucose measurements with handheld glucose meters and a portable glucose analyzer. Am J Clin Pathol. 2000;113(1):75-86. (Pubitemid 30217342)
    • (2000) American Journal of Clinical Pathology , vol.113 , Issue.1 , pp. 75-86
    • Tang, Z.1    Du, X.2    Louie, R.F.3    Kost, G.J.4
  • 17
    • 77952064592 scopus 로고    scopus 로고
    • Proficiency testing performance in US laboratories: Results reported to the Center for Medicare and Medicaid Services, 1994 through 2006
    • Howerton D, Krolak JM, Manasterski A, Handsfield JH. Proficiency testing performance in US laboratories: results reported to the Center for Medicare and Medicaid Services, 1994 through 2006. Arch Pathol Lab Med. 2010;134(5):751-8.
    • (2010) Arch Pathol Lab Med , vol.134 , Issue.5 , pp. 751-758
    • Howerton, D.1    Krolak, J.M.2    Manasterski, A.3    Handsfield, J.H.4
  • 20
    • 70350175257 scopus 로고    scopus 로고
    • Glucose meters: A review of technical challenges to obtaining accurate results
    • Tonyushkina K, Nichols JH. Glucose meters: a review of technical challenges to obtaining accurate results. J Diabetes Sci Technol. 2009;3(4):971-80.
    • (2009) J Diabetes Sci Technol , vol.3 , Issue.4 , pp. 971-980
    • Tonyushkina, K.1    Nichols, J.H.2
  • 21
    • 33845684564 scopus 로고    scopus 로고
    • Approved IFCC recommendation on reporting results for blood glucose: International Federation of Clinical Chemistry and Laboratory Medicine Scientific Division, Working Group on Selective Electrodes and Point-of-Care Testing (IFCC-SD-WG-SEPOCT)
    • IFCC-SD-WG-SEPOCT
    • D'Orazio P, Burnett RW, Fogh-Anderson N, Jacobs E, Kuwa K, Külpmann WR, Larsson L, Lewenstam A, Maas AH, Mager G, Naskalski JW, Okorodudu AO; IFCC-SD-WG-SEPOCT. Approved IFCC recommendation on reporting results for blood glucose: International Federation of Clinical Chemistry and Laboratory Medicine Scientific Division, Working Group on Selective Electrodes and Point-of-Care Testing (IFCC-SD-WG-SEPOCT). Clin Chem Lab Med. 2006;44(12):1486-90.
    • (2006) Clin Chem Lab Med , vol.44 , Issue.12 , pp. 1486-1490
    • D'Orazio, P.1    Burnett, R.W.2    Fogh-Anderson, N.3    Jacobs, E.4    Kuwa, K.5    Külpmann, W.R.6    Larsson, L.7    Lewenstam, A.8    Maas, A.H.9    Mager, G.10    Naskalski, J.W.11    Okorodudu, A.O.12
  • 23
    • 0028346374 scopus 로고
    • 2 affect ExacTech meter glucose measurements
    • Kilpatrick ES, Rumley AG, Smith EA. Variation in sample pH and pO2 afect ExacTech meter glucose measurements. Diabet Med. 1994;11(5):506-9. (Pubitemid 24210273)
    • (1994) Diabetic Medicine , vol.11 , Issue.5 , pp. 506-509
    • Kilpatrick, E.S.1    Rumley, A.G.2    Smith, E.A.3
  • 24
    • 84900549398 scopus 로고    scopus 로고
    • MAUDE database (updated December 12, 2011)
    • U.S. Food and Drug Administration. http://www.accessdata.fda.gov/scripts/ cdrh/cfdocs/cfMAUDE/search.cfm. MAUDE database (updated December 12, 2011).
  • 25
    • 33646092275 scopus 로고    scopus 로고
    • Interference of Accel® wipes with LifeScan SureStep® Flexx glucose meters
    • Larsen CL, Jackson C, Lyon ME. Interference of Accel® wipes with LifeScan SureStep® Flexx glucose meters. Clin Biochem. 2006;39(4):414-16.
    • (2006) Clin Biochem , vol.39 , Issue.4 , pp. 414-416
    • Larsen, C.L.1    Jackson, C.2    Lyon, M.E.3
  • 26
    • 78149497045 scopus 로고    scopus 로고
    • Disinfectant wipes containing hydrogen peroxide induce overestimation of glucose results obtained with LifeScan SureStep® Flexx glucose meter
    • Desmeules P, Ethier J, Allard P. Disinfectant wipes containing hydrogen peroxide induce overestimation of glucose results obtained with LifeScan SureStep® Flexx glucose meter. Clin Biochem. 2010;43(18):1472-4.
    • (2010) Clin Biochem , vol.43 , Issue.18 , pp. 1472-1474
    • Desmeules, P.1    Ethier, J.2    Allard, P.3
  • 27
    • 77951733801 scopus 로고    scopus 로고
    • A review of standards and statistics used to describe blood glucose monitor performance
    • Krouwer JS, Cembrowski GS. A review of standards and statistics used to describe blood glucose monitor performance. J Diabetes Sci Technol. 2010;4(1):75-83.
    • (2010) J Diabetes Sci Technol , vol.4 , Issue.1 , pp. 75-83
    • Krouwer, J.S.1    Cembrowski, G.S.2
  • 28
    • 0023239559 scopus 로고
    • Consensus statement on self-monitoring of blood glucose
    • American Diabetes Association (ADA)
    • American Diabetes Association (ADA). Consensus statement on self-monitoring of blood glucose. Diabetes Care. 1987;10(1):93-9.
    • (1987) Diabetes Care , vol.10 , Issue.1 , pp. 93-99
  • 29
    • 0030066052 scopus 로고    scopus 로고
    • Self-monitoring of blood glucose: Clinical practice recommendations
    • American Diabetes Association
    • American Diabetes Association. Self-monitoring of blood glucose: clinical practice recommendations. Diabetes Care. 1996;19:S62-6.
    • (1996) Diabetes Care , vol.19
  • 30
    • 40249120466 scopus 로고    scopus 로고
    • Standards of medical care in diabetes - 2008
    • American Diabetes Association
    • American Diabetes Association. Standards of medical care in diabetes - 2008. Diabetes Care. 2008;31 Suppl 1:S12-54.
    • (2008) Diabetes Care , vol.31 , Issue.SUPPL. 1
  • 32
    • 84900532530 scopus 로고    scopus 로고
    • Accessed November 24, 2011
    • U.S. Food and Drug Administration. http://www.fda.gov/MedicalDevices/ DeviceRegulationandGuidance/GuidanceDocuments/ucm094134.htm. Accessed November 24, 2011.
  • 35
    • 82255191077 scopus 로고    scopus 로고
    • Assessing point-of-care hemoglobin measurement
    • Morey TE, Gravenstein N, Rice MJ. Assessing point-of-care hemoglobin measurement. Anesth Analg. 2011;113(6):1289-91.
    • (2011) Anesth Analg , vol.113 , Issue.6 , pp. 1289-1291
    • Morey, T.E.1    Gravenstein, N.2    Rice, M.J.3
  • 36
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care. 1987;10(5):622-8. (Pubitemid 17158937)
    • (1987) Diabetes Care , vol.10 , Issue.5 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 37
    • 0033855803 scopus 로고    scopus 로고
    • A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose
    • Parkes JL, Slatin SL, Pardo S, Ginsberg BH. A new consensus error grid to evaluate the clinical significance of inaccuracies in the measurement of blood glucose. Diabetes Care. 2000;23(8):1143-8. (Pubitemid 30616803)
    • (2000) Diabetes Care , vol.23 , Issue.8 , pp. 1143-1148
    • Parkes, J.L.1    Slatin, S.L.2    Pardo, S.3    Ginsberg, B.H.4
  • 40
    • 30944465397 scopus 로고    scopus 로고
    • A comparison of blood glucose meters in Australia
    • DOI 10.1016/j.diabres.2005.05.013, PII S0168822705002287
    • Cohen M, Boyle E, Delaney C, Shaw J. A comparison of blood glucose meters in Australia. Diabetes Res Clin Pract. 2006;71(2):113-8. (Pubitemid 43112101)
    • (2006) Diabetes Research and Clinical Practice , vol.71 , Issue.2 , pp. 113-118
    • Cohen, M.1    Boyle, E.2    Delaney, C.3    Shaw, J.4
  • 42
    • 39049121806 scopus 로고    scopus 로고
    • A glucose meter accuracy and precision comparison: The freestyle flash versus the accu-chek advantage, accu-chek compact plus, ascensia contour, and the BD logic
    • DOI 10.1089/dia.2007.0244
    • Thomas LE, Kane MP, Bakst G, Busch RS, Hamilton RA, Abelseth JM. A glucose meter accuracy and precision comparison: the FreeStyle Flash versus the Accu-Chek Advantage, Accu-Chek Compact Plus, Ascensia Contour, and the BD Logic. Diabetes Technol Ther. 2008;10(2):102-10. (Pubitemid 351232863)
    • (2008) Diabetes Technology and Therapeutics , vol.10 , Issue.2 , pp. 102-110
    • Thomas, L.E.1    Kane, M.P.2    Bakst, G.3    Busch, R.S.4    Hamilton, R.A.5    Abelseth, J.M.6
  • 43
    • 70349306724 scopus 로고    scopus 로고
    • Accuracy and precision of four value-added blood glucose meters: The Abbott Optium, the DDI Prodigy, the HDI True Track, and the HypoGuard Assure Pro
    • Shefield CA, Kane MP, Bakst G, Busch RS, Abelseth JM, Hamilton RA. Accuracy and precision of four value-added blood glucose meters: the Abbott Optium, the DDI Prodigy, the HDI True Track, and the HypoGuard Assure Pro. Diabetes Technol Ther. 2009;11(9):587-92.
    • (2009) Diabetes Technol Ther , vol.11 , Issue.9 , pp. 587-592
    • Shefield, C.A.1    Kane, M.P.2    Bakst, G.3    Busch, R.S.4    Abelseth, J.M.5    Hamilton, R.A.6
  • 44
    • 67650854596 scopus 로고    scopus 로고
    • Comparison of blood glucose meters in a New Zealand diabetes centre
    • Florkowski C, Budgen C, Kendall D, Lunt H, Moore MP. Comparison of blood glucose meters in a New Zealand diabetes centre. Ann Clin Biochem. 2009;46(Pt 4):302-5.
    • (2009) Ann Clin Biochem , vol.46 , Issue.PART 4 , pp. 302-305
    • Florkowski, C.1    Budgen, C.2    Kendall, D.3    Lunt, H.4    Moore, M.P.5
  • 45
    • 0347624613 scopus 로고    scopus 로고
    • A multicenter study of the accuracy of the One Touch Ultra home glucose meter in children with type I diabetes
    • The Diabetes Research in Children Network (DIRECNET) Research Group
    • The Diabetes Research in Children Network (DIRECNET) Research Group. A multicenter study of the accuracy of the One Touch Ultra home glucose meter in children with type I diabetes. Diabetes Technol Ther. 2003;5(6):933-41.
    • (2003) Diabetes Technol Ther , vol.5 , Issue.6 , pp. 933-941
  • 46
    • 23844476497 scopus 로고    scopus 로고
    • Comparison of the accuracy of the hemocue glucose analyzer with the Yellow Springs Instrument glucose oxidase analyzer, particularly in hypoglycemia
    • DOI 10.1530/eje.1.01952
    • Stork AD, Kemperman H, Erkelens DW, Veneman TF. Comparison of the accuracy of the HemoCue glucose analyzer with the Yellow Springs Instrument glucose oxidase analyzer, particularly in hypoglycemia. Eur J Endocrinol. 2005;153(2):275-81. (Pubitemid 41167485)
    • (2005) European Journal of Endocrinology , vol.153 , Issue.2 , pp. 275-281
    • Stork, A.D.M.1    Kemperman, H.2    Erkelens, D.W.3    Veneman, T.F.4
  • 47
    • 29744438635 scopus 로고    scopus 로고
    • The Accutrend sensor glucose analyzer may not be adequate in bedside testing for neonatal hypoglycemia
    • Rosenthal M, Ugele B, Lipowsky G, Küster H. The Accutrend sensor glucose analyzer may not be adequate in bedside testing for neonatal hypoglycemia. Eur J Pediatr. 2006;165(2):99-107.
    • (2006) Eur J Pediatr , vol.165 , Issue.2 , pp. 99-107
    • Rosenthal, M.1    Ugele, B.2    Lipowsky, G.3    Küster, H.4
  • 50
    • 35648983591 scopus 로고    scopus 로고
    • Reliability assessment of glucose measurement by HemoCue analyser in a neonatal intensive care unit
    • DOI 10.1515/CCLM.2007.302
    • Bellini C, Serra G, Risso D, Mazzella M, Bonioli E. Reliability assessment of glucose measurement by HemoCue analyser in a neonatal intensive care unit. Clin Chem Lab Med. 2007;45(11):1549-54. (Pubitemid 350036559)
    • (2007) Clinical Chemistry and Laboratory Medicine , vol.45 , Issue.11 , pp. 1549-1554
    • Bellini, C.1    Serra, G.2    Risso, D.3    Mazzella, M.4    Bonioli, E.5
  • 51
    • 0026779446 scopus 로고
    • HemoCue: Evaluation of a portable photometric system for determining glucose in whole blood
    • Ashworth L, Gibb I, Alberti KG. HemoCue: evaluation of a portable photometric system for determining glucose in whole blood. Clin Chem. 1992;38(8 Pt 1):1479-82.
    • (1992) Clin Chem , vol.38 , Issue.8 PART 1 , pp. 1479-1482
    • Ashworth, L.1    Gibb, I.2    Alberti, K.G.3
  • 52
    • 0027463199 scopus 로고
    • An assessment of the effect of haematocrit on the HemoCue blood glucose analyser
    • Wiener K. An assessment of the efect of haematocrit on the HemoCue blood glucose analyzer. Ann Clin Biochem. 1993;30(Pt 1):90-3. (Pubitemid 23049427)
    • (1993) Annals of Clinical Biochemistry , vol.30 , Issue.1 , pp. 90-93
    • Wiener, K.1
  • 54
    • 2042443796 scopus 로고    scopus 로고
    • Evaluation of a glucose meter against analytical quality specifications for hospital use
    • DOI 10.1016/j.cccn.2004.01.021, PII S0009898104000579
    • Singh DG, Agarwal M, Bishawi B. Evaluation of a glucose meter against analytical quality specifications for hospital use. Clin Chim Acta. 2004;343(1-2):217-21. (Pubitemid 38534520)
    • (2004) Clinica Chimica Acta , vol.343 , Issue.1-2 , pp. 217-221
    • Dhatt, G.S.1    Agarwal, M.2    Bishawi, B.3
  • 57
    • 20344392145 scopus 로고    scopus 로고
    • Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction
    • DOI 10.1016/j.cccn.2005.01.027, PII S0009898105000768
    • Rao LV, Jakubiak F, Sidwell JS, Winkleman JW, Snyder ML. Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction. Clin Chim Acta. 2005;356(1-2):178-83. (Pubitemid 40779900)
    • (2005) Clinica Chimica Acta , vol.356 , Issue.1-2 , pp. 178-183
    • Rao, L.V.1    Jakubiak, F.2    Sidwell, J.S.3    Winkelman, J.W.4    Snyder, M.L.5
  • 58
    • 13444273132 scopus 로고    scopus 로고
    • Evaluation of Roche Accu-Chek Go and Medisense Optium blood glucose meters
    • DOI 10.1016/j.cccn.2004.10.013
    • Hawkins RC. Evaluation of Roche Accu-Chek Go and Medisense Optium blood glucose meters. Clin Chim Acta. 2005;353(1-2):127-31. (Pubitemid 40215439)
    • (2005) Clinica Chimica Acta , vol.353 , Issue.1-2 , pp. 127-131
    • Hawkins, R.C.1
  • 60
    • 67649183171 scopus 로고    scopus 로고
    • American Association of Clinical Endocrinologists and American Diabetes Association Consensus statement on inpatient glycemic control
    • American Association of Clinical Endocrinologists; American Diabetes Association
    • Moghissi ES, Korytowski MT, DiNardo M, Einhorn D, Hellman R, Hirsch IB, Inzucchi SE, Ismail-Beigi F, Kirkman MS, Umpierrez GE; American Association of Clinical Endocrinologists; American Diabetes Association. American Association of Clinical Endocrinologists and American Diabetes Association Consensus statement on inpatient glycemic control. Endocr Pract. 2009;15(4):353-69.
    • (2009) Endocr Pract , vol.15 , Issue.4 , pp. 353-369
    • Moghissi, E.S.1    Korytowski, M.T.2    DiNardo, M.3    Einhorn, D.4    Hellman, R.5    Hirsch, I.B.6    Inzucchi, S.E.7    Ismail-Beigi, F.8    Kirkman, M.S.9    Umpierrez, G.E.10
  • 61
    • 0028262386 scopus 로고
    • Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: Are they accurate?
    • Maser RE, Butler MA, DeCherney GS. Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: are they accurate? Crit Care Med. 1994;22(4):595-9. (Pubitemid 24121559)
    • (1994) Critical Care Medicine , vol.22 , Issue.4 , pp. 595-599
    • Maser, R.E.1    Butler, M.A.2    DeCherney, G.S.3
  • 62
    • 0033966742 scopus 로고    scopus 로고
    • Point-of-care glucose testing: Effects of critical care variables, influence of reference instruments, and a modular glucose meter design
    • Louie RF, Tang Z, Sutton DV, Lee JH, Kost GJ. Point-of-care glucose testing: efects of critical care variables, influence of reference instruments, and a modular glucose meter design. Arch Pathol Lab Med. 2000;124(2):257-66. (Pubitemid 30090612)
    • (2000) Archives of Pathology and Laboratory Medicine , vol.124 , Issue.2 , pp. 257-266
    • Louie, R.F.1    Tang, Z.2    Sutton, D.V.3    Lee, J.H.4    Kost, G.J.5
  • 64
    • 60849131272 scopus 로고    scopus 로고
    • Diferences in glucose values obtained from point-of-care glucose meters and laboratory analysis in critically ill patients
    • Cook A, Laughlin D, Moore M, North D, Wilkins K, Wong G, Wallace-Scroggs A, Halvorsen L. Diferences in glucose values obtained from point-of-care glucose meters and laboratory analysis in critically ill patients. Am J Crit Care. 2009;18(1):65-72.
    • (2009) Am J Crit Care , vol.18 , Issue.1 , pp. 65-72
    • Cook, A.1    Laughlin, D.2    Moore, M.3    North, D.4    Wilkins, K.5    Wong, G.6    Wallace-Scroggs, A.7    Halvorsen, L.8
  • 65
    • 84857431968 scopus 로고    scopus 로고
    • Dynamic electrochemistry corrects for hematocrit interference on blood glucose determinations with patient selfmeasurement devices
    • Mushholt PB, Schipper C, Thomé N, Ramljak S, Schmidt M, Forst T, Pfützner A. Dynamic electrochemistry corrects for hematocrit interference on blood glucose determinations with patient selfmeasurement devices. J Diabetes Sci Technol. 2011;5(5):1167-75.
    • (2011) J Diabetes Sci Technol , vol.5 , Issue.5 , pp. 1167-1175
    • Mushholt, P.B.1    Schipper, C.2    Thomé, N.3    Ramljak, S.4    Schmidt, M.5    Forst, T.6    Pfützner, A.7
  • 66
    • 84857437572 scopus 로고    scopus 로고
    • Dynamic electrochemistry: A step in the right direction
    • Rice MJ. Dynamic electrochemistry: a step in the right direction. J Diabetes Sci Technol. 2011;5(5):1176-8.
    • (2011) J Diabetes Sci Technol , vol.5 , Issue.5 , pp. 1176-1178
    • Rice, M.J.1
  • 67
    • 84900550364 scopus 로고    scopus 로고
    • Intravenous fluids cause systemic bias in a conductivity-based point-of-care hematocrit meter
    • Epub, PMID 22156329
    • Wu P, Morey TE, Harris NS, Gravenstein N, Rice MJ. Intravenous fluids cause systemic bias in a conductivity-based point-of-care hematocrit meter. Anesth Analg. 2011. Epub, PMID 22156329.
    • (2011) Anesth Analg
    • Wu, P.1    Morey, T.E.2    Harris, N.S.3    Gravenstein, N.4    Rice, M.J.5
  • 69
    • 19844365140 scopus 로고    scopus 로고
    • Agreement between bedside blood and plasma glucose measurement in the ICU setting
    • Finkielman JD, Oyen LJ, Afessa B. Agreement between bedside blood and plasma glucose measurement in the ICU setting. Chest. 2005;127(5):49-51.
    • (2005) Chest , vol.127 , Issue.5 , pp. 49-51
    • Finkielman, J.D.1    Oyen, L.J.2    Afessa, B.3
  • 71
    • 42149100490 scopus 로고    scopus 로고
    • Accuracy of bedside glucometry in critically ill patients: Influence of clinical characteristics and perfusion index
    • DOI 10.4065/83.4.400
    • Desachy A, Vuagnat AC, Ghazali AD, Baudin OT, Longuet OH, Calvat SN, Gissot V. Accuracy of bedside glucometry in critically ill patients: influence of clinical characteristics and perfusion index. Mayo Clin Proc. 2008;83(4):400-5. (Pubitemid 351536465)
    • (2008) Mayo Clinic Proceedings , vol.83 , Issue.4 , pp. 400-405
    • Desachy, A.1    Vuagnat, A.C.2    Ghazali, A.D.3    Baudin, O.T.4    Longuet, O.H.5    Calvat, S.N.6    Gissot, V.7
  • 72
    • 73749085297 scopus 로고    scopus 로고
    • Bedside capillary blood glucose measurements in critically ill patients: Influence of catecholamine therapy
    • Fekih Hassen M, Ayed S, Gharbi R, Ben Sik Ali H, Marghli S, Elatrous S. Bedside capillary blood glucose measurements in critically ill patients: influence of catecholamine therapy. Diabetes Res Clin Pract. 2010;87(1):87-91.
    • (2010) Diabetes Res Clin Pract , vol.87 , Issue.1 , pp. 87-91
    • Fekih Hassen, M.1    Ayed, S.2    Gharbi, R.3    Ben Sik Ali, H.4    Marghli, S.5    Elatrous, S.6
  • 75
    • 0035170340 scopus 로고    scopus 로고
    • Pilot study of the accuracy of bedside glucometry in the intensive care unit
    • Ray JG, Hamielec C, Mastracci T. Pilot study of the accuracy of bedside glucometry in the intensive care unit. Crit Care Med. 2001;29(11):2205-7. (Pubitemid 33063552)
    • (2001) Critical Care Medicine , vol.29 , Issue.11 , pp. 2205-2207
    • Ray, J.G.1    Hamielec, C.2    Mastracci, T.3
  • 76
    • 34250620535 scopus 로고    scopus 로고
    • Accuracy of Roche Accu-Chek inform whole blood capillary, arterial, and venous glucose values in patients receiving intensive intravenous insulin therapy after cardiac surgery
    • Karon BS, Gandhi GY, Nuttall GA, Bryant SC, Schaf HV, McMahon MM, Santrach PJ. Accuracy of Roche Accu-Chek inform whole blood capillary, arterial, and venous glucose values in patients receiving intensive intravenous insulin therapy after cardiac surgery. Am J Clin Pathol. 2007;127(6):919-26.
    • (2007) Am J Clin Pathol , vol.127 , Issue.6 , pp. 919-926
    • Karon, B.S.1    Gandhi, G.Y.2    Nuttall, G.A.3    Bryant, S.C.4    Schaf, H.V.5    McMahon, M.M.6    Santrach, P.J.7
  • 79
    • 50049124154 scopus 로고    scopus 로고
    • Comparison of POCT and central laboratory blood glucose results using arterial, capillary, and venous samples from MICU patients on a tight glycemic protocol
    • Petersen JR, Graves DF, Tacker DH, Okorodudu AO, Mohammad AA, Cardenas VJ Jr. Comparison of POCT and central laboratory blood glucose results using arterial, capillary, and venous samples from MICU patients on a tight glycemic protocol. Clin Chim Acta. 2008;396(1-2):10-13.
    • (2008) Clin Chim Acta , vol.396 , Issue.1-2 , pp. 10-13
    • Petersen, J.R.1    Graves, D.F.2    Tacker, D.H.3    Okorodudu, A.O.4    Mohammad, A.A.5    Cardenas Jr., V.J.6
  • 81
    • 77953148918 scopus 로고    scopus 로고
    • Glucose meter performance criteria for tight glycemic control estimated by simulation modeling
    • Karon BS, Boyd JC, Klee GG. Glucose meter performance criteria for tight glycemic control estimated by simulation modeling. Clin Chem. 2010;56(7):1091-7.
    • (2010) Clin Chem , vol.56 , Issue.7 , pp. 1091-1097
    • Karon, B.S.1    Boyd, J.C.2    Klee, G.G.3
  • 82
    • 84655171127 scopus 로고    scopus 로고
    • Automated near-continuous glucose monitoring measured in plasma using mid-infrared spectroscopy
    • Jax T, Heise T, Nosek L, Gable J, Lim G, Calentine C. Automated near-continuous glucose monitoring measured in plasma using mid-infrared spectroscopy. J Diabetes Sci Technol. 2011;5(2):345-52.
    • (2011) J Diabetes Sci Technol , vol.5 , Issue.2 , pp. 345-352
    • Jax, T.1    Heise, T.2    Nosek, L.3    Gable, J.4    Lim, G.5    Calentine, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.