메뉴 건너뛰기




Volumn 28, Issue 4, 2014, Pages 309-322

Measurement of blood pressure

Author keywords

Arterial catheter; Monitoring; Non invasive; Oscillometry; Radial artery applanation tonometry; Tonometry; Volume clamp method

Indexed keywords

APPLANATION TONOMETRY; ARTERIAL PRESSURE; ARTERY CATHETER; ARTERY WALL; ARTICLE; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CRITICALLY ILL PATIENT; HEMODYNAMIC MONITORING; HIGH RISK PATIENT; HUMAN; NON INVASIVE BLOOD PRESSURE MONITOR; NON INVASIVE PROCEDURE; OSCILLOMETRY; PATIENT SAFETY; PRIORITY JOURNAL; PULSE WAVE; RADIAL ARTERY; RANDOMIZED CONTROLLED TRIAL (TOPIC); TONOMETRY; VOLUME CLAMP METHOD; WAVEFORM; BLOOD PRESSURE; DEVICES;

EID: 84927946196     PISSN: 15216896     EISSN: 1532169X     Source Type: Journal    
DOI: 10.1016/j.bpa.2014.08.001     Document Type: Review
Times cited : (112)

References (76)
  • 1
    • 0017760154 scopus 로고
    • A short history of blood pressure measurement
    • Booth J. A short history of blood pressure measurement. Proc R Soc Med 1977;70:793-799
    • (1977) Proc R Soc Med , vol.70 , pp. 793-799
    • Booth, J.1
  • 2
    • 33744527833 scopus 로고    scopus 로고
    • Duration of hypotension before initiation of effective antimicrobial therapy is the critical determinant of survival in human septic shock
    • Kumar A, Roberts D, Wood KE, et al. Duration of hypotension before initiation of effective antimicrobial therapy is the critical determinant of survival in human septic shock. Crit Care Med 2006;34:1589-96
    • (2006) Crit Care Med , vol.34 , pp. 1589-1596
    • Kumar, A.1    Roberts, D.2    Wood, K.E.3
  • 3
    • 84898820371 scopus 로고    scopus 로고
    • High versus low blood-pressure target in patients with septic shock
    • Asfar P, Meziani F, Hamel JF, et al. High versus low blood-pressure target in patients with septic shock. N Engl J Med 2014; 370:1583-93
    • (2013) N Engl J Med , vol.370 , pp. 1583-1593
    • Asfar, P.1    Meziani, F.2    Hamel, J.F.3
  • 4
    • 84883257383 scopus 로고    scopus 로고
    • Relationship between intraoperative mean arterial pressure and clinical outcomes after noncardiac surgery: Toward an empirical definition of hypotension
    • Walsh M, Devereaux PJ, Garg AX, et al. Relationship between intraoperative mean arterial pressure and clinical outcomes after noncardiac surgery: toward an empirical definition of hypotension. Anesthesiology 2013;119:507-515
    • (2013) Anesthesiology , vol.119 , pp. 507-515
    • Walsh, M.1    Devereaux, P.J.2    Garg, A.X.3
  • 6
    • 85030388773 scopus 로고
    • Recherches sur le pouls au moyen d'un nouvel appareil enregistreur le sphygmographie
    • Marey EJ. Recherches sur le pouls au moyen d'un nouvel appareil enregistreur le sphygmographie. E. Thunot et cie; 1860
    • (1860) E. Thunot et Cie
    • Marey, E.J.1
  • 7
    • 0001823617 scopus 로고
    • The physiology and clinical use of the sphygmograph
    • Mahomed F. The physiology and clinical use of the sphygmograph. Med Times Gaz 1872;1872:1
    • (1872) Med Times Gaz 1872 , pp. 1
    • Mahomed, F.1
  • 8
    • 0012573233 scopus 로고
    • Time relationship of dynamic events in the cardiac chambers, pulmonary artery and aorta in man
    • Braunwald E, Fishman AP, Cournand A. Time relationship of dynamic events in the cardiac chambers, pulmonary artery and aorta in man. Circ Res 1956;4:100-107
    • (1956) Circ Res , vol.4 , pp. 100-107
    • Braunwald, E.1    Fishman, A.P.2    Cournand, A.3
  • 9
    • 0023428631 scopus 로고
    • Computer model analysis of the radial artery pressure waveform
    • Schwid HA, Taylor LA, Smith NT. Computer model analysis of the radial artery pressure waveform. J Clin Monit 1987;3: 220-8
    • (1987) J Clin Monit , vol.3 , pp. 220-228
    • Schwid, H.A.1    Taylor, L.A.2    Smith, N.T.3
  • 10
    • 0030802410 scopus 로고    scopus 로고
    • Birth weight, growth, and blood pressure: An annual follow-up study of children aged 5 through 21 years
    • Uiterwaal CS, Anthony S, Launer LJ, et al. Birth weight, growth, and blood pressure: an annual follow-up study of children aged 5 through 21 years. Hypertension 1997;30:267-71
    • (1997) Hypertension , vol.30 , pp. 267-271
    • Uiterwaal, C.S.1    Anthony, S.2    Launer, L.J.3
  • 11
    • 0024854224 scopus 로고
    • Noninvasive determination of age-related changes in the human arterial pulse
    • Kelly R, Hayward C, Avolio A, et al. Noninvasive determination of age-related changes in the human arterial pulse. Circulation 1989;80:1652-1659
    • (1989) Circulation , vol.80 , pp. 1652-1659
    • Kelly, R.1    Hayward, C.2    Avolio, A.3
  • 12
    • 0032054270 scopus 로고    scopus 로고
    • Influence of body height on pulsatile arterial hemodynamic data
    • Smulyan H, Marchais SJ, Pannier B, et al. Influence of body height on pulsatile arterial hemodynamic data. J Am Coll Cardiol 1998;31:1103-1109
    • (1998) J Am Coll Cardiol , vol.31 , pp. 1103-1109
    • Smulyan, H.1    Marchais, S.J.2    Pannier, B.3
  • 14
    • 0003637916 scopus 로고
    • The factors influencing the prominence of the dicrotic wave
    • Lewis T. The factors influencing the prominence of the dicrotic wave. J Physiol 1906;34:414-429
    • (1906) J Physiol , vol.34 , pp. 414-429
    • Lewis, T.1
  • 16
    • 0034657775 scopus 로고    scopus 로고
    • The influence of heart rate on augmentation index and central arterial pressure in humans
    • Wilkinson IB, MacCallum H, Flint L, et al. The influence of heart rate on augmentation index and central arterial pressure in humans. J Physiol 2000;525(Pt 1):263-270
    • (2000) J Physiol , vol.525 , pp. 263-270
    • Wilkinson, I.B.1    Maccallum, H.2    Flint, L.3
  • 17
    • 66149118641 scopus 로고    scopus 로고
    • Femoral-radial arterial pressure gradients in critically ill patients
    • Galluccio ST, Chapman MJ, Finnis ME. Femoral-radial arterial pressure gradients in critically ill patients. Crit Care Resusc 2009;11:34-38
    • (2009) Crit Care Resusc , vol.11 , pp. 34-38
    • Galluccio, S.T.1    Chapman, M.J.2    Finnis, M.E.3
  • 18
    • 0021347103 scopus 로고
    • Wave reflections and the arterial pulse
    • O'Rourke MF, Yaginuma T. Wave reflections and the arterial pulse. Arch Intern Med 1984;144:366-371
    • (1984) Arch Intern Med , vol.144 , pp. 366-371
    • O'Rourke, M.F.1    Yaginuma, T.2
  • 19
    • 0014337859 scopus 로고
    • Pressure wave transmission along the human aorta Changes with age and in arterial degenerative disease
    • O'Rourke MF, Blazek JV, Morreels Jr CL, et al. Pressure wave transmission along the human aorta. Changes with age and in arterial degenerative disease. Circ Res 1968;23:567-579
    • (1968) Circ Res , vol.23 , pp. 567-579
    • O'Rourke, M.F.1    Blazek, J.V.2    Morreels, C.L.3
  • 20
    • 0014301032 scopus 로고
    • Disparities between aortic and peripheral pulse pressures induced by upright exercise and vasomotor changes in man
    • Rowell LB, Brengelmann GL, Blackmon JR, et al. Disparities between aortic and peripheral pulse pressures induced by upright exercise and vasomotor changes in man. Circulation 1968;37:954-64
    • (1968) Circulation , vol.37 , pp. 954-964
    • Rowell, L.B.1    Brengelmann, G.L.2    Blackmon, J.R.3
  • 21
    • 84961014643 scopus 로고
    • Comparison of simultaneously recorded central and peripheral arterial pressure pulses during rest, exercise and tilted position in man
    • Kroeker EJ,Wood EH. Comparison of simultaneously recorded central and peripheral arterial pressure pulses during rest, exercise and tilted position in man. Circ Res 1955;3:623-632
    • (1955) Circ Res , vol.3 , pp. 623-632
    • Kroeker, E.J.1    Wood, E.H.2
  • 22
    • 0021966475 scopus 로고
    • Can we trust the direct radial artery pressure immediately following cardiopulmonary bypass?
    • Stern DH, Gerson JI, Allen FB, et al. Can we trust the direct radial artery pressure immediately following cardiopulmonary bypass? Anesthesiology 1985;62:557-61
    • (1985) Anesthesiology , vol.62 , pp. 557-561
    • Stern, D.H.1    Gerson, J.I.2    Allen, F.B.3
  • 23
    • 0026688843 scopus 로고
    • Differences between aortic and radial artery pressure associated with cardiopulmonary bypass
    • Rich GF, Lubanski Jr RE, McLoughlin TM. Differences between aortic and radial artery pressure associated with cardiopulmonary bypass. Anesthesiology 1992;77:63-66
    • (1992) Anesthesiology , vol.77 , pp. 63-66
    • Rich, G.F.1    Lubanski, R.E.2    McLoughlin, T.M.3
  • 24
    • 0031717777 scopus 로고    scopus 로고
    • Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients
    • Dorman T, Breslow MJ, Lipsett PA, et al. Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. Crit Care Med 1998;26:1646-1649
    • (1998) Crit Care Med , vol.26 , pp. 1646-1649
    • Dorman, T.1    Breslow, M.J.2    Lipsett, P.A.3
  • 25
    • 0031692867 scopus 로고    scopus 로고
    • On the accuracy of intra-arterial pressure measurement: The pressure gradient effect
    • Hynson JM, Katz JA, Mangano DT. On the accuracy of intra-arterial pressure measurement: the pressure gradient effect. Crit Care Med 1998;26:1623-1624
    • (1998) Crit Care Med , vol.26 , pp. 1623-1624
    • Hynson, J.M.1    Katz, J.A.2    Mangano, D.T.3
  • 26
    • 0034086529 scopus 로고    scopus 로고
    • Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass
    • Chauhan S, Saxena N, Mehrotra S, et al. Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass. J Cardiothorac Vasc Anesth 2000;14:274-276
    • (2000) J Cardiothorac Vasc Anesth , vol.14 , pp. 274-276
    • Chauhan, S.1    Saxena, N.2    Mehrotra, S.3
  • 27
    • 0031240036 scopus 로고    scopus 로고
    • Evaluation of possible measuring errors from overlaying pressure components in invasive blood pressure recording with external transducers
    • Lambertz M, Kraft M, Boenick U. Evaluation of possible measuring errors from overlaying pressure components in invasive blood pressure recording with external transducers. Biomed Tech Berl 1997;42:249-255
    • (1997) Biomed Tech Berl , vol.42 , pp. 249-255
    • Lambertz, M.1    Kraft, M.2    Boenick, U.3
  • 28
    • 0026690056 scopus 로고
    • The fast flush test measures the dynamic response of the entire blood pressure monitoring system
    • Kleinman B, Powell S, Kumar P, et al. The fast flush test measures the dynamic response of the entire blood pressure monitoring system. Anesthesiology 1992;77:1215-1220
    • (1992) Anesthesiology , vol.77 , pp. 1215-1220
    • Kleinman, B.1    Powell, S.2    Kumar, P.3
  • 29
    • 0036087258 scopus 로고    scopus 로고
    • Clinical review: Complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine
    • Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care 2002;6:199-204
    • (2002) Crit Care , vol.6 , pp. 199-204
    • Scheer, B.1    Perel, A.2    Pfeiffer, U.J.3
  • 30
    • 0034090864 scopus 로고    scopus 로고
    • Prevention of intravascular catheter-related infections
    • Mermel LA. Prevention of intravascular catheter-related infections. Ann Intern Med 2000;132:391-402
    • (2000) Ann Intern Med , vol.132 , pp. 391-402
    • Mermel, L.A.1
  • 31
    • 33748107510 scopus 로고    scopus 로고
    • Attributable cost of catheter-associated bloodstream infections among intensive care patients in a nonteaching hospital
    • Warren DK, Quadir WW, Hollenbeak CS, et al. Attributable cost of catheter-associated bloodstream infections among intensive care patients in a nonteaching hospital. Crit Care Med 2006;34:2084-2089
    • (2006) Crit Care Med , vol.34 , pp. 2084-2089
    • Warren, D.K.1    Quadir, W.W.2    Hollenbeak, C.S.3
  • 32
    • 0027363881 scopus 로고
    • Human blood pressure determination by sphygmomanometry
    • Perloff D, Grim C, Flack J, et al. Human blood pressure determination by sphygmomanometry. Circulation 1993;88: 2460-2470
    • (1993) Circulation , vol.88 , pp. 2460-2470
    • Perloff, D.1    Grim, C.2    Flack, J.3
  • 34
    • 79956065780 scopus 로고    scopus 로고
    • Blood pressure measurement: Retrospective and prospective views
    • Smulyan H, Safar ME. Blood pressure measurement: retrospective and prospective views. Am J Hypertens 2011;24: 628-634
    • (2011) Am J Hypertens , vol.24 , pp. 628-634
    • Smulyan, H.1    Safar, M.E.2
  • 35
    • 0035527552 scopus 로고    scopus 로고
    • Oscillometric blood pressure measurement: Progress and problems
    • van Montfrans GA. Oscillometric blood pressure measurement: progress and problems. Blood Press Monit 2001;6: 287-290
    • (2001) Blood Press Monit , vol.6 , pp. 287-290
    • Van Montfrans, G.A.1
  • 36
    • 0031874834 scopus 로고    scopus 로고
    • Determinants of the limits of agreement between the sphygmomanometer and the SpaceLabs 90207 device for blood pressure measurement in health volunteers and insulin-dependent diabetic patients
    • van Ittersum FJ, Wijering RM, Lambert J, et al. Determinants of the limits of agreement between the sphygmomanometer and the SpaceLabs 90207 device for blood pressure measurement in health volunteers and insulin-dependent diabetic patients. J Hypertens 1998;16:1125-1130
    • (1998) J Hypertens , vol.16 , pp. 1125-1130
    • Van Ittersum, F.J.1    Wijering, R.M.2    Lambert, J.3
  • 37
    • 0028787844 scopus 로고
    • Random zero sphygmomanometer versus automatic oscillometric blood pressure monitor is either the instrument of choice?
    • Goonasekera CD, Dillon MJ. Random zero sphygmomanometer versus automatic oscillometric blood pressure monitor; is either the instrument of choice? J Hum Hypertens 1995;9:885-889
    • (1995) J Hum Hypertens , vol.9 , pp. 885-889
    • Goonasekera, C.D.1    Dillon, M.J.2
  • 38
    • 58149359267 scopus 로고    scopus 로고
    • Comparison of noninvasive blood pressure measurements in patients with atrial fibrillation
    • 525-516
    • Anastas ZM, Jimerson E, Garolis S. Comparison of noninvasive blood pressure measurements in patients with atrial fibrillation. J Cardiovasc Nurs 2008;23:519-24. quiz 525-516
    • (2008) J Cardiovasc Nurs , vol.23 , pp. 519-524
    • Anastas, Z.M.1    Jimerson, E.2    Garolis, S.3
  • 39
    • 13444255966 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurement in humans and experimental animals: Part 1: Blood pressure measurement in humans: A statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on high blood pressure research
    • Pickering TG, Hall JE, Appel LJ, et al. Recommendations for blood pressure measurement in humans and experimental animals: part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on high blood pressure research. Circulation 2005;111:697-716
    • (2005) Circulation , vol.111 , pp. 697-716
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.J.3
  • 40
    • 0034051418 scopus 로고    scopus 로고
    • Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients
    • Bur A, Hirschl MM, Herkner H, et al. Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients. Crit Care Med 2000;28:371-376
    • (2000) Crit Care Med , vol.28 , pp. 371-376
    • Bur, A.1    Hirschl, M.M.2    Herkner, H.3
  • 41
    • 0037351948 scopus 로고    scopus 로고
    • Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients
    • Bur A, Herkner H, Vlcek M, et al. Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients. Crit Care Med 2003;31:793-799
    • (2003) Crit Care Med , vol.31 , pp. 793-799
    • Bur, A.1    Herkner, H.2    Vlcek, M.3
  • 42
    • 34447568391 scopus 로고    scopus 로고
    • Arterial blood pressure monitoring in overweight critically ill patients: Invasive or noninvasive?
    • Araghi A, Bander JJ, Guzman JA. Arterial blood pressure monitoring in overweight critically ill patients: invasive or noninvasive? Crit Care 2006;10:R64
    • (2006) Crit Care , vol.10 , pp. R64
    • Araghi, A.1    Bander, J.J.2    Guzman, J.A.3
  • 43
    • 84872080010 scopus 로고    scopus 로고
    • Methods of blood pressure measurement in the ICU
    • Lehman LW, Saeed M, Talmor D, et al. Methods of blood pressure measurement in the ICU. Crit Care Med 2013;41:34-40
    • (2013) Crit Care Med , vol.41 , pp. 34-40
    • Lehman, L.W.1    Saeed, M.2    Talmor, D.3
  • 44
    • 80055008990 scopus 로고    scopus 로고
    • Invasive and concomitant noninvasive intraoperative blood pressure monitoring: Observed differences in measurements and associated therapeutic interventions
    • Wax DB, Lin HM, Leibowitz AB. Invasive and concomitant noninvasive intraoperative blood pressure monitoring: observed differences in measurements and associated therapeutic interventions. Anesthesiology 2011;115:973-8
    • (2011) Anesthesiology , vol.115 , pp. 973-978
    • Wax, D.B.1    Lin, H.M.2    Leibowitz, A.B.3
  • 45
    • 84893009023 scopus 로고    scopus 로고
    • Noninvasive continuous versus intermittent arterial pressure monitoring: Evaluation of the vascular unloading technique (CNAP device) in the emergency department
    • Wagner JY, Prantner JS, Meidert AS, et al. Noninvasive continuous versus intermittent arterial pressure monitoring: evaluation of the vascular unloading technique (CNAP device) in the emergency department. Scand J Trauma Resusc Emerg Med 2014;22:8
    • (2013) Scand J Trauma Resusc Emerg Med , vol.22 , pp. 8
    • Wagner, J.Y.1    Prantner, J.S.2    Meidert, A.S.3
  • 46
    • 84864189333 scopus 로고    scopus 로고
    • Society of interventional R. Guidelines for the prevention of intravascular catheter-related infections: Recommendations relevant to interventional radiology for venous catheter placement and maintenance
    • Miller DL, O'Grady NP, Society of Interventional R. Guidelines for the prevention of intravascular catheter-related infections: recommendations relevant to interventional radiology for venous catheter placement and maintenance. J Vasc Interv Radiol 2012;23:997-1007
    • (2012) J Vasc Interv Radiol , vol.23 , pp. 997-1007
    • Miller, D.L.1    O'Grady, N.P.2
  • 47
    • 84855817728 scopus 로고    scopus 로고
    • Clinical review: Update on hemodynamic monitoring e a consensus of 16
    • Vincent JL, Rhodes A, Perel A, et al. Clinical review: update on hemodynamic monitoring e a consensus of 16. Crit Care 2011;15:229
    • (2011) Crit Care , vol.15 , pp. 229
    • Vincent, J.L.1    Rhodes, A.2    Perel, A.3
  • 48
    • 0017032294 scopus 로고
    • Contribution to the continuous indirect blood pressure measurement
    • Penaz J, Voigt A, TeichmannW. Contribution to the continuous indirect blood pressure measurement. Z Gesamte Inn Med 1976;31:1030-3
    • (1976) Z Gesamte Inn Med , vol.31 , pp. 1030-1033
    • Penaz, J.1    Voigt, A.2    Teichmann, W.3
  • 49
    • 33745491620 scopus 로고
    • Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger
    • Wesseling KH, Settels JJ, van der Hoeven GM, et al. Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger. Cardiovasc Res 1985;19:139-145
    • (1985) Cardiovasc Res , vol.19 , pp. 139-145
    • Wesseling, K.H.1    Settels, J.J.2    Van Der Hoeven, G.M.3
  • 50
    • 0030334214 scopus 로고    scopus 로고
    • Estimation of ascending aortic pressure from radial arterial pressure using a generalised transfer function
    • Takazawa K, O'Rourke MF, Fujita M, et al. Estimation of ascending aortic pressure from radial arterial pressure using a generalised transfer function. Z Kardiol 1996;85(Suppl. 3):137-139
    • (1996) Z Kardiol , vol.85 , pp. 137-139
    • Takazawa, K.1    O'Rourke, M.F.2    Fujita, M.3
  • 51
    • 0026756113 scopus 로고
    • Effects of graded vasoconstriction upon the measurement of finger arterial pressure
    • Imholz BP, Parati G, Mancia G, et al. Effects of graded vasoconstriction upon the measurement of finger arterial pressure. J Hypertens 1992;10:979-84
    • (1992) J Hypertens , vol.10 , pp. 979-984
    • Imholz, B.P.1    Parati, G.2    Mancia, G.3
  • 52
    • 33746367766 scopus 로고    scopus 로고
    • Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops
    • Fortin J, Marte W, Grullenberger R, et al. Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med 2006;36:941-57
    • (2006) Comput Biol Med , vol.36 , pp. 941-957
    • Fortin, J.1    Marte, W.2    Grullenberger, R.3
  • 53
    • 84865213001 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: Comparison with four other dynamic indices
    • Monnet X, Dres M, Ferre A, et al. Prediction of fluid responsiveness by a continuous non-invasive assessment of arterial pressure in critically ill patients: comparison with four other dynamic indices. Br J Anaesth 2012;109:330-8
    • (2012) Br J Anaesth , vol.109 , pp. 330-338
    • Monnet, X.1    Dres, M.2    Ferre, A.3
  • 54
    • 84862782626 scopus 로고    scopus 로고
    • Noninvasive continuous arterial blood pressure monitoring with nexfin R
    • Martina JR, Westerhof BE, van Goudoever J, et al. Noninvasive continuous arterial blood pressure monitoring with nexfin(R). Anesthesiology 2012;116:1092-103
    • (2012) Anesthesiology , vol.116 , pp. 1092-1103
    • Martina, J.R.1    Westerhof, B.E.2    Van Goudoever, J.3
  • 55
    • 77956019814 scopus 로고    scopus 로고
    • Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: Assessment during general anaesthesia
    • Jeleazcov C, Krajinovic L, Munster T, et al. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br J Anaesth 2010;105:264-72
    • (2010) Br J Anaesth , vol.105 , pp. 264-272
    • Jeleazcov, C.1    Krajinovic, L.2    Munster, T.3
  • 56
    • 84856303645 scopus 로고    scopus 로고
    • Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement
    • Ilies C, Bauer M, Berg P, et al. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth 2012;108:202-10
    • (2012) Br J Anaesth , vol.108 , pp. 202-210
    • Ilies, C.1    Bauer, M.2    Berg, P.3
  • 57
    • 84864270411 scopus 로고    scopus 로고
    • A comparison of a continuous noninvasive arterial pressure (CNAP) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU
    • Jagadeesh AM, Singh NG, Mahankali S. A comparison of a continuous noninvasive arterial pressure (CNAP) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU. Ann Card Anaesth 2012;15:180-184
    • (2012) Ann Card Anaesth , vol.15 , pp. 180-184
    • Jagadeesh, A.M.1    Singh, N.G.2    Mahankali, S.3
  • 58
    • 84922338379 scopus 로고    scopus 로고
    • Continuous non-invasive monitoring improves blood pressure stability in upright position: Randomized controlled trial
    • epub ahead of print
    • Benes J, Simanova A, Tovarnicka T, et al. Continuous non-invasive monitoring improves blood pressure stability in upright position: randomized controlled trial. J Clin Monit Comput 2014 [epub ahead of print]
    • (2014) J Clin Monit Comput
    • Benes, J.1    Simanova, A.2    Tovarnicka, T.3
  • 59
    • 60049095571 scopus 로고    scopus 로고
    • Continuous non-invasive arterial pressure technique improves patient monitoring during interventional endoscopy
    • Siebig S, Rockmann F, Sabel K, et al. Continuous non-invasive arterial pressure technique improves patient monitoring during interventional endoscopy. Int J Med Sci 2009;6:37-42
    • (2009) Int J Med Sci , vol.6 , pp. 37-42
    • Siebig, S.1    Rockmann, F.2    Sabel, K.3
  • 60
    • 84865264710 scopus 로고    scopus 로고
    • Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement
    • Ilies C, Kiskalt H, Siedenhans D, et al. Detection of hypotension during Caesarean section with continuous non-invasive arterial pressure device or intermittent oscillometric arterial pressure measurement. Br J Anaesth 2012;109:413-419
    • (2012) Br J Anaesth , vol.109 , pp. 413-419
    • Ilies, C.1    Kiskalt, H.2    Siedenhans, D.3
  • 61
    • 16044371643 scopus 로고    scopus 로고
    • Finger arterial pressure measurement with Finapres
    • Wesseling KH. Finger arterial pressure measurement with Finapres. Z Kardiol 1996;85(Suppl. 3):38-44
    • (1996) Z Kardiol , vol.85 , pp. 38-44
    • Wesseling, K.H.1
  • 62
    • 0031051049 scopus 로고    scopus 로고
    • Models of brachial to finger pulse wave distortion and pressure decrement
    • Gizdulich P, Prentza A, Wesseling KH. Models of brachial to finger pulse wave distortion and pressure decrement. Cardiovasc Res 1997;33:698-705
    • (1997) Cardiovasc Res , vol.33 , pp. 698-705
    • Gizdulich, P.1    Prentza, A.2    Wesseling, K.H.3
  • 63
    • 84880525789 scopus 로고    scopus 로고
    • Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients
    • Hohn A, Defosse JM, Becker S, et al. Non-invasive continuous arterial pressure monitoring with Nexfin does not sufficiently replace invasive measurements in critically ill patients. Br J Anaesth 2013;111:178-84
    • (2013) Br J Anaesth , vol.111 , pp. 178-184
    • Hohn, A.1    Defosse, J.M.2    Becker, S.3
  • 64
    • 78651131847 scopus 로고
    • A transducer for the continuous external measurement of arterial blood pressure
    • Pressman GL, Newgard PM. A transducer for the continuous external measurement of arterial blood pressure. IEEE Trans Biomed Eng 1963;10:73-81
    • (1963) IEEE Trans Biomed Eng , vol.10 , pp. 73-81
    • Pressman, G.L.1    Newgard, P.M.2
  • 65
    • 0015043142 scopus 로고
    • Arterial tonometry for the atraumatic measurement of arterial blood pressure
    • Stein PD, Blick EF. Arterial tonometry for the atraumatic measurement of arterial blood pressure. J Appl Phys 1971;30: 593-596
    • (1971) J Appl Phys , vol.30 , pp. 593-596
    • Stein, P.D.1    Blick, E.F.2
  • 67
    • 0025847851 scopus 로고
    • Blood pressure measurement by arterial tonometry in controlled hypotension
    • Kemmotsu O, Ueda M, Otsuka H, et al. Blood pressure measurement by arterial tonometry in controlled hypotension. Anesth Analg 1991;73:54-8
    • (1991) Anesth Analg , vol.73 , pp. 54-58
    • Kemmotsu, O.1    Ueda, M.2    Otsuka, H.3
  • 68
    • 84863085965 scopus 로고    scopus 로고
    • Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry
    • Dueck R, Goedje O, Clopton P. Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry. J Clin Monit Comput 2012;26:75-83
    • (2012) J Clin Monit Comput , vol.26 , pp. 75-83
    • Dueck, R.1    Goedje, O.2    Clopton, P.3
  • 69
    • 0028243132 scopus 로고
    • Theory of the oscillometric maximum and the systolic and diastolic detection ratios
    • Drzewiecki G, Hood R, Apple H. Theory of the oscillometric maximum and the systolic and diastolic detection ratios. Ann Biomed Eng 1994;22:88-96
    • (1994) Ann Biomed Eng , vol.22 , pp. 88-96
    • Drzewiecki, G.1    Hood, R.2    Apple, H.3
  • 70
    • 31444450219 scopus 로고    scopus 로고
    • An accuracy evaluation of the T-Line tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patients
    • Janelle GM, Gravenstein N. An accuracy evaluation of the T-Line tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patients. Anesth Analg 2006;102: 484-90
    • (2006) Anesth Analg , vol.102 , pp. 484-490
    • Janelle, G.M.1    Gravenstein, N.2
  • 71
    • 39149084640 scopus 로고    scopus 로고
    • An evaluation of the T-Line tensymeter continuous noninvasive blood pressure device during induced hypotension
    • Szmuk P, Pivalizza E, Warters RD, et al. An evaluation of the T-Line tensymeter continuous noninvasive blood pressure device during induced hypotension. Anaesthesia 2008;63:307-12
    • (2008) Anaesthesia , vol.63 , pp. 307-312
    • Szmuk, P.1    Pivalizza, E.2    Warters, R.D.3
  • 72
    • 84866743712 scopus 로고    scopus 로고
    • The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients
    • Saugel B, Fassio F, Hapfelmeier A, et al. The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients. Intensive Care Med 2012;38:1471-1477
    • (2012) Intensive Care Med , vol.38 , pp. 1471-1477
    • Saugel, B.1    Fassio, F.2    Hapfelmeier, A.3
  • 73
    • 84880550339 scopus 로고    scopus 로고
    • Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: A method comparison study using the T-Line TL-200pro device
    • Saugel B, Meidert AS, Hapfelmeier A, et al. Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device. Br J Anaesth 2013; 111:185-90
    • (2013) Br J Anaesth , vol.111 , pp. 185-190
    • Saugel, B.1    Meidert, A.S.2    Hapfelmeier, A.3
  • 74
    • 84887402327 scopus 로고    scopus 로고
    • Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome
    • Meidert AS, Huber W, Hapfelmeier A, et al. Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome. J Crit Care 2013;28:908-12.
    • (2013) J Crit Care , vol.28 , pp. 908-912
    • Meidert, A.S.1    Huber, W.2    Hapfelmeier, A.3
  • 75
    • 84896831760 scopus 로고    scopus 로고
    • Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: Comparison with invasively assessed radial arterial pressure
    • Meidert AS, Huber W, Muller JN, et al. Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure. Br J Anaesth 2014;112:521e8.
    • (2014) Br J Anaesth , vol.112 , pp. 521-528
    • Meidert, A.S.1    Huber, W.2    Muller, J.N.3
  • 76
    • 84877003790 scopus 로고    scopus 로고
    • Non-invasive, minute-to-minute estimates of systemic arterial pressure and pulse pressure variation using radial artery tonometry
    • Colquhoun DA, Forkin KT, Dunn LK, et al. Non-invasive, minute-to-minute estimates of systemic arterial pressure and pulse pressure variation using radial artery tonometry. J Med Eng Technol 2013;37:197e202.
    • (2013) J Med Eng Technol , vol.37 , pp. 197-202
    • Colquhoun, D.A.1    Forkin, K.T.2    Dunn, L.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.