메뉴 건너뛰기




Volumn 10, Issue 2, 2006, Pages

Arterial blood pressure monitoring in overweight critically ill patients: Invasive or noninvasive?

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARM CIRCUMFERENCE; ARTERIAL PRESSURE; ARTICLE; AUSCULTATION; BLOOD PRESSURE CUFF; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; BODY MASS; CALIBRATION; CONTROLLED STUDY; CRITICALLY ILL PATIENT; DIAGNOSTIC ACCURACY; DIASTOLIC BLOOD PRESSURE; FEMALE; HEMODYNAMICS; HUMAN; HYPERTENSION; INTENSIVE CARE UNIT; INTERMETHOD COMPARISON; INVASIVE PROCEDURE; MAJOR CLINICAL STUDY; MALE; MANOMETER; MEAN ARTERIAL PRESSURE; NON INVASIVE MEASUREMENT; OBESITY; OBSERVATIONAL STUDY; OSCILLOMETRY; PRIORITY JOURNAL; PROSPECTIVE STUDY; RADIAL ARTERY; BLOOD PRESSURE; COHORT ANALYSIS; COMPARATIVE STUDY; CRITICAL ILLNESS; METHODOLOGY; MIDDLE AGED; MONITOR; MONITORING; PHYSIOLOGY;

EID: 34447568391     PISSN: 13648535     EISSN: 1466609X     Source Type: Journal    
DOI: 10.1186/cc4896     Document Type: Article
Times cited : (84)

References (17)
  • 1
    • 1442325347 scopus 로고    scopus 로고
    • Clinical approach to the critically ill, morbidly obese patient
    • 10.1164/rccm.200309-1256CC
    • El-Solh A Clinical approach to the critically ill, morbidly obese patient Am J Respir Crit Care 2004 169 557-561 10.1164/rccm.200309-1256CC
    • (2004) Am J Respir Crit Care , vol.169 , pp. 557-561
    • El-Solh, A.1
  • 2
    • 0031912062 scopus 로고    scopus 로고
    • The obese patient in the ICU
    • 9498970
    • Marik P Varon J The obese patient in the ICU Chest 1998 113 492-498 9498970
    • (1998) Chest , vol.113 , pp. 492-498
    • Marik, P.1    Varon, J.2
  • 3
    • 2342487989 scopus 로고    scopus 로고
    • Blood pressure measurement in research and in clinical practice: Recent evidence
    • 15073495
    • Parati G Boli G Manci G Blood pressure measurement in research and in clinical practice: Recent evidence Curr Opin Nephrol Hypertens 2004 13 343-357 15073495
    • (2004) Curr Opin Nephrol Hypertens , vol.13 , pp. 343-357
    • Parati, G.1    Boli, G.2    Manci, G.3
  • 4
    • 1842418717 scopus 로고    scopus 로고
    • Measuring blood pressure: Pitfalls and recommendations
    • 10.1093/ndt/gfg602 15031326
    • Tholl U Forstner K Anlauf M Measuring blood pressure: Pitfalls and recommendations Nephrol Dial Transplant 2004 19 766-770 10.1093/ndt/ gfg602 15031326
    • (2004) Nephrol Dial Transplant , vol.19 , pp. 766-770
    • Tholl, U.1    Forstner, K.2    Anlauf, M.3
  • 5
    • 0037466925 scopus 로고    scopus 로고
    • Measuring blood pressure accurately. New and persistent changes
    • 10.1001/jama.289.8.1027 12597757
    • Jones DW Appel LJ Sheps SG Roccella EJ Lenfant C Measuring blood pressure accurately. New and persistent changes JAMA 2003 289 1027-1030 10.1001/jama.289.8.1027 12597757
    • (2003) JAMA , vol.289 , pp. 1027-1030
    • Jones, D.W.1    Appel, L.J.2    Sheps, S.G.3    Roccella, E.J.4    Lenfant, C.5
  • 6
    • 0034051418 scopus 로고    scopus 로고
    • Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients
    • 10.1097/00003246-200002000-00014 10708169
    • Bur A Hirschl MM Herkner H Oschatz E Kofler J Woisetschläger C Laggner AN Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients Crit Care Med 2000 28 371-376 10.1097/ 00003246-200002000-00014 10708169
    • (2000) Crit Care Med , vol.28 , pp. 371-376
    • Bur, A.1    Hirschl, M.M.2    Herkner, H.3    Oschatz, E.4    Kofler, J.5    Woisetschläger, C.6    Laggner, A.N.7
  • 7
    • 0027475416 scopus 로고
    • Improved accuracy of indirect blood pressure measurement in patients with obese arms
    • 8427664
    • Stolt M Sjönell G Aström H Rössner S Hansson L Improved accuracy of indirect blood pressure measurement in patients with obese arms Am J Hypertens 1993 6 66-71 8427664
    • (1993) Am J Hypertens , vol.6 , pp. 66-71
    • Stolt, M.1    Sjönell, G.2    Aström, H.3    Rössner, S.4    Hansson, L.5
  • 8
    • 0020701614 scopus 로고
    • Accuracy of auscultatory blood pressure measurements in hypertensive and obese subjects
    • 6848459
    • Nielsen PE Larsen B Holstein P Poulsen HL Accuracy of auscultatory blood pressure measurements in hypertensive and obese subjects Hypertension 1983 5 122-127 6848459
    • (1983) Hypertension , vol.5 , pp. 122-127
    • Nielsen, P.E.1    Larsen, B.2    Holstein, P.3    Poulsen, H.L.4
  • 9
    • 0019523842 scopus 로고
    • Direct blood pressure measurement. Dynamic response requirements
    • 7469106
    • Gardner RM Direct blood pressure measurement. Dynamic response requirements Anesthesiology 1981 54 227-236 7469106
    • (1981) Anesthesiology , vol.54 , pp. 227-236
    • Gardner, R.M.1
  • 10
    • 13444255966 scopus 로고    scopus 로고
    • Recommendations for blood pressure measurements in humans and experimental animals: Part 1: Blood pressure management in humans: A statement for professionals from the Subcomittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research
    • 10.1161/01.CIR.0000154900.76284.F6 15699287
    • Pickering TG Hall JE Appel L Falkner BE Graves J Hill MN Jones DW Kurtz T Sheps SG Roccella EJ Recommendations for blood pressure measurements inBhumans and experimental animals: Part 1: blood pressure management in humans: A statement for professionals from the Subcomittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research Circulation 2005 111 697-716 10.1161/01.CIR.0000154900.76284.F6 15699287
    • (2005) Circulation , vol.111 , pp. 697-716
    • Pickering, T.G.1    Hall, J.E.2    Appel, L.3    Falkner, B.E.4    Graves, J.5    Hill, M.N.6    Jones, D.W.7    Kurtz, T.8    Sheps, S.G.9    Roccella, E.J.10
  • 11
    • 0035987980 scopus 로고    scopus 로고
    • Principles and techniques of blood pressure measurement
    • 10.1016/S0733-8651(01)00009-1 12119797
    • Pickering TG Principles and techniques of blood pressure measurement Cardiol Clin 2002 20 207-223 10.1016/S0733-8651(01)00009-1 12119797
    • (2002) Cardiol Clin , vol.20 , pp. 207-223
    • Pickering, T.G.1
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 2868172
    • Bland JM Altman DG Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1986 1 307-310 2868172
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 0037351948 scopus 로고    scopus 로고
    • Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients
    • 10.1097/01.CCM.0000053650.12025.1A 12626986
    • Bur A Herkner H Vlcek M Woisetschläger C Laggner AN Hirschl MM Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients Crit Care Med 2003 31 793-799 10.1097/01.CCM.0000053650.12025.1A 12626986
    • (2003) Crit Care Med , vol.31 , pp. 793-799
    • Bur, A.1    Herkner, H.2    Vlcek, M.3    Woisetschläger, C.4    Laggner, A.N.5    Hirschl, M.M.6
  • 15
    • 0034531946 scopus 로고    scopus 로고
    • An evaluation of a new continuous blood pressure monitoring system in critically ill patients
    • 10.1016/S0952-8180(00)00201-4 11137411
    • Heard SO Lisbon A Toth I Ramasubramanian R An evaluation of a new continuous blood pressure monitoring system in critically ill patients J Clin Anesth 2000 12 509-518 10.1016/S0952-8180(00)00201-4 11137411
    • (2000) J Clin Anesth , vol.12 , pp. 509-518
    • Heard, S.O.1    Lisbon, A.2    Toth, I.3    Ramasubramanian, R.4
  • 16
    • 0037301090 scopus 로고    scopus 로고
    • What will replace the mercury sphygmomanometer?
    • 10.1097/00126097-200302000-00005 12604932
    • Pickering TG What will replace the mercury sphygmomanometer? Blood Press Monit 2003 8 23-25 10.1097/00126097-200302000-00005 12604932
    • (2003) Blood Press Monit , vol.8 , pp. 23-25
    • Pickering, T.G.1
  • 17
    • 0021682907 scopus 로고
    • Biases in the measurement of arterial pressure
    • 6499482
    • Finnie KJ Watts DG Amstrong PW Biases in the measurement of arterial pressure Crit Care Med 1984 12 965-968 6499482
    • (1984) Crit Care Med , vol.12 , pp. 965-968
    • Finnie, K.J.1    Watts, D.G.2    Amstrong, P.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.