메뉴 건너뛰기




Volumn 28, Issue 6, 2013, Pages 908-912

Evaluation of the radial artery applanation tonometry technology for continuous noninvasive blood pressure monitoring compared with central aortic blood pressure measurements in patients with multiple organ dysfunction syndrome

Author keywords

Diastolic blood pressure; Hemodynamic monitoring; Mean arterial pressure; Systolic blood pressure; T Line

Indexed keywords

ABDOMINAL AORTA; ACCURACY; ADULT; AGED; ARTERIAL PRESSURE; ARTICLE; BLOOD PRESSURE MEASUREMENT; BLOOD PRESSURE MONITORING; CARDIOVASCULAR MONITORING DEVICE; CENTRAL AORTIC BLOOD PRESSURE MEASUREMENT; CLINICAL ARTICLE; CONTROLLED STUDY; DIASTOLIC ARTERIAL PRESSURE; FEMALE; FEMORAL ARTERY; HUMAN; INTENSIVE CARE UNIT; INTERMETHOD COMPARISON; INVASIVE PROCEDURE; MALE; MEAN ARTERIAL PRESSURE; MULTIPLE ORGAN FAILURE; NON INVASIVE PROCEDURE; PATIENT ASSESSMENT; RADIAL ARTERY APPLANATION TONOMETRY; SYSTOLIC ARTERIAL PRESSURE; TONOMETRY;

EID: 84887402327     PISSN: 08839441     EISSN: 15578615     Source Type: Journal    
DOI: 10.1016/j.jcrc.2013.06.012     Document Type: Article
Times cited : (34)

References (26)
  • 1
    • 77956019814 scopus 로고    scopus 로고
    • Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia
    • Jeleazcov C., Krajinovic L., Munster T., et al. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br J Anaesth 2010, 105(3):264-272.
    • (2010) Br J Anaesth , vol.105 , Issue.3 , pp. 264-272
    • Jeleazcov, C.1    Krajinovic, L.2    Munster, T.3
  • 2
    • 84856303645 scopus 로고    scopus 로고
    • Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement
    • Ilies C., Bauer M., Berg P., et al. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth 2012, 108(2):202-210.
    • (2012) Br J Anaesth , vol.108 , Issue.2 , pp. 202-210
    • Ilies, C.1    Bauer, M.2    Berg, P.3
  • 3
    • 84858387796 scopus 로고    scopus 로고
    • Clinical validation of a continuous non-invasive haemodynamic monitor (CNAP™ 500) during general anaesthesia
    • Hahn R., Rinosl H., Neuner M., et al. Clinical validation of a continuous non-invasive haemodynamic monitor (CNAP™ 500) during general anaesthesia. Br J Anaesth 2012, 108(4):581-585.
    • (2012) Br J Anaesth , vol.108 , Issue.4 , pp. 581-585
    • Hahn, R.1    Rinosl, H.2    Neuner, M.3
  • 4
    • 84866350766 scopus 로고    scopus 로고
    • Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery
    • Fischer M.O., Avram R., Carjaliu I., et al. Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery. Br J Anaesth 2012, 109(4):514-521.
    • (2012) Br J Anaesth , vol.109 , Issue.4 , pp. 514-521
    • Fischer, M.O.1    Avram, R.2    Carjaliu, I.3
  • 5
    • 84862782626 scopus 로고    scopus 로고
    • Noninvasive continuous arterial blood pressure monitoring with Nexfin(R)
    • Martina J.R., Westerhof B.E., van Goudoever J., et al. Noninvasive continuous arterial blood pressure monitoring with Nexfin(R). Anesthesiology 2012, 116(5):1092-1103.
    • (2012) Anesthesiology , vol.116 , Issue.5 , pp. 1092-1103
    • Martina, J.R.1    Westerhof, B.E.2    van Goudoever, J.3
  • 6
    • 31444450219 scopus 로고    scopus 로고
    • An accuracy evaluation of the T-Line Tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patients
    • Janelle G.M., Gravenstein N. An accuracy evaluation of the T-Line Tensymeter (continuous noninvasive blood pressure management device) versus conventional invasive radial artery monitoring in surgical patients. Anesth Analg 2006, 102(2):484-490.
    • (2006) Anesth Analg , vol.102 , Issue.2 , pp. 484-490
    • Janelle, G.M.1    Gravenstein, N.2
  • 7
    • 39149084640 scopus 로고    scopus 로고
    • An evaluation of the T-Line Tensymeter continuous noninvasive blood pressure device during induced hypotension
    • Szmuk P., Pivalizza E., Warters R.D., et al. An evaluation of the T-Line Tensymeter continuous noninvasive blood pressure device during induced hypotension. Anaesthesia 2008, 63(3):307-312.
    • (2008) Anaesthesia , vol.63 , Issue.3 , pp. 307-312
    • Szmuk, P.1    Pivalizza, E.2    Warters, R.D.3
  • 8
    • 84863085965 scopus 로고    scopus 로고
    • Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry
    • Dueck R., Goedje O., Clopton P. Noninvasive continuous beat-to-beat radial artery pressure via TL-200 applanation tonometry. J Clin Monit Comput 2012, 26(2):75-83.
    • (2012) J Clin Monit Comput , vol.26 , Issue.2 , pp. 75-83
    • Dueck, R.1    Goedje, O.2    Clopton, P.3
  • 9
    • 84866743712 scopus 로고    scopus 로고
    • The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients
    • Saugel B., Fassio F., Hapfelmeier A., et al. The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients. Intensive Care Med 2012, 38(9):1471-1477.
    • (2012) Intensive Care Med , vol.38 , Issue.9 , pp. 1471-1477
    • Saugel, B.1    Fassio, F.2    Hapfelmeier, A.3
  • 10
    • 84880550339 scopus 로고    scopus 로고
    • Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device
    • [epub ahead of print]
    • Saugel B., Meidert A.S., Hapfelmeier A., et al. Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device. Br J Anaesth 2013, [epub ahead of print].
    • (2013) Br J Anaesth
    • Saugel, B.1    Meidert, A.S.2    Hapfelmeier, A.3
  • 11
    • 0028784689 scopus 로고
    • Multiple organ dysfunction score: a reliable descriptor of a complex clinical outcome
    • Marshall J.C., Cook D.J., Christou N.V., et al. Multiple organ dysfunction score: a reliable descriptor of a complex clinical outcome. Crit Care Med 1995, 23(10):1638-1652.
    • (1995) Crit Care Med , vol.23 , Issue.10 , pp. 1638-1652
    • Marshall, J.C.1    Cook, D.J.2    Christou, N.V.3
  • 12
    • 0036905885 scopus 로고    scopus 로고
    • The multiple organ dysfunction score (MODS) versus the Sequential Organ Failure Assessment (SOFA) score in outcome prediction
    • Peres Bota D., Melot C., Lopes Ferreira F., et al. The multiple organ dysfunction score (MODS) versus the Sequential Organ Failure Assessment (SOFA) score in outcome prediction. Intensive Care Med 2002, 28(11):1619-1624.
    • (2002) Intensive Care Med , vol.28 , Issue.11 , pp. 1619-1624
    • Peres Bota, D.1    Melot, C.2    Lopes Ferreira, F.3
  • 13
    • 34347375489 scopus 로고    scopus 로고
    • Agreement between methods of measurement with multiple observations per individual
    • Bland J.M., Altman D.G. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 2007, 17(4):571-582.
    • (2007) J Biopharm Stat , vol.17 , Issue.4 , pp. 571-582
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 78651131847 scopus 로고
    • A transducer for the continuous external measurement of arterial blood pressure
    • Pressman G.L., Newgard P.M. A transducer for the continuous external measurement of arterial blood pressure. IEEE Trans Biomed Eng 1963, 10:73-81.
    • (1963) IEEE Trans Biomed Eng , vol.10 , pp. 73-81
    • Pressman, G.L.1    Newgard, P.M.2
  • 15
    • 0020961299 scopus 로고
    • Arterial tonometry: review and analysis
    • Drzewiecki G.M., Melbin J., Noordergraaf A. Arterial tonometry: review and analysis. J Biomech 1983, 16(2):141-152.
    • (1983) J Biomech , vol.16 , Issue.2 , pp. 141-152
    • Drzewiecki, G.M.1    Melbin, J.2    Noordergraaf, A.3
  • 16
    • 0015043142 scopus 로고
    • Arterial tonometry for the atraumatic measurement of arterial blood pressure
    • Stein P.D., Blick E.F. Arterial tonometry for the atraumatic measurement of arterial blood pressure. J Appl Physiol 1971, 30(4):593-596.
    • (1971) J Appl Physiol , vol.30 , Issue.4 , pp. 593-596
    • Stein, P.D.1    Blick, E.F.2
  • 17
    • 0026061353 scopus 로고
    • Arterial tonometry for noninvasive, continuous blood pressure monitoring during anesthesia
    • Kemmotsu O., Ueda M., Otsuka H., et al. Arterial tonometry for noninvasive, continuous blood pressure monitoring during anesthesia. Anesthesiology 1991, 75(2):333-340.
    • (1991) Anesthesiology , vol.75 , Issue.2 , pp. 333-340
    • Kemmotsu, O.1    Ueda, M.2    Otsuka, H.3
  • 18
    • 0025847851 scopus 로고
    • Blood pressure measurement by arterial tonometry in controlled hypotension
    • Kemmotsu O., Ueda M., Otsuka H., et al. Blood pressure measurement by arterial tonometry in controlled hypotension. Anesth Analg 1991, 73(1):54-58.
    • (1991) Anesth Analg , vol.73 , Issue.1 , pp. 54-58
    • Kemmotsu, O.1    Ueda, M.2    Otsuka, H.3
  • 19
    • 0027325111 scopus 로고
    • Accuracy of a continuous blood pressure monitor based on arterial tonometry
    • Sato T., Nishinaga M., Kawamoto A., et al. Accuracy of a continuous blood pressure monitor based on arterial tonometry. Hypertension 1993, 21(6 Pt 1):866-874.
    • (1993) Hypertension , vol.21 , Issue.6 PART 1 , pp. 866-874
    • Sato, T.1    Nishinaga, M.2    Kawamoto, A.3
  • 20
    • 0028007505 scopus 로고
    • Comparison of arterial tonometry with radial artery catheter measurements of blood pressure in anesthetized patients
    • Siegel L.C., Brock-Utne J.G., Brodsky J.B. Comparison of arterial tonometry with radial artery catheter measurements of blood pressure in anesthetized patients. Anesthesiology 1994, 81(3):578-584.
    • (1994) Anesthesiology , vol.81 , Issue.3 , pp. 578-584
    • Siegel, L.C.1    Brock-Utne, J.G.2    Brodsky, J.B.3
  • 21
    • 0028998437 scopus 로고
    • An evaluation of the N-CAT, a new arterial tonometer
    • Searle N.R., Gauthier J., Sahab P. An evaluation of the N-CAT, a new arterial tonometer. Can J Anaesth 1995, 42(6):526-531.
    • (1995) Can J Anaesth , vol.42 , Issue.6 , pp. 526-531
    • Searle, N.R.1    Gauthier, J.2    Sahab, P.3
  • 22
    • 68549098079 scopus 로고    scopus 로고
    • Amplification of the pressure pulse in the upper limb in healthy, middle-aged men and women
    • Segers P., Mahieu D., Kips J., et al. Amplification of the pressure pulse in the upper limb in healthy, middle-aged men and women. Hypertension 2009, 54(2):414-420.
    • (2009) Hypertension , vol.54 , Issue.2 , pp. 414-420
    • Segers, P.1    Mahieu, D.2    Kips, J.3
  • 23
    • 77951721505 scopus 로고    scopus 로고
    • Noninvasive measurement of central vascular pressures with arterial tonometry: clinical revival of the pulse pressure waveform?
    • Nelson M.R., Stepanek J., Cevette M., et al. Noninvasive measurement of central vascular pressures with arterial tonometry: clinical revival of the pulse pressure waveform?. Mayo Clin Proc 2010, 85(5):460-472.
    • (2010) Mayo Clin Proc , vol.85 , Issue.5 , pp. 460-472
    • Nelson, M.R.1    Stepanek, J.2    Cevette, M.3
  • 24
    • 0031717777 scopus 로고    scopus 로고
    • Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients
    • Dorman T., Breslow M.J., Lipsett P.A., et al. Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. Crit Care Med 1998, 26(10):1646-1649.
    • (1998) Crit Care Med , vol.26 , Issue.10 , pp. 1646-1649
    • Dorman, T.1    Breslow, M.J.2    Lipsett, P.A.3
  • 25
    • 66149118641 scopus 로고    scopus 로고
    • Femoral-radial arterial pressure gradients in critically ill patients
    • Galluccio S.T., Chapman M.J., Finnis M.E. Femoral-radial arterial pressure gradients in critically ill patients. Crit Care Resusc 2009, 11(1):34-38.
    • (2009) Crit Care Resusc , vol.11 , Issue.1 , pp. 34-38
    • Galluccio, S.T.1    Chapman, M.J.2    Finnis, M.E.3
  • 26
    • 23044461875 scopus 로고    scopus 로고
    • Changes in arterial pressure during mechanical ventilation
    • quiz 449-5
    • Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology 2005, 103(2):419-428. quiz 449-5.
    • (2005) Anesthesiology , vol.103 , Issue.2 , pp. 419-428
    • Michard, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.