-
1
-
-
13844267068
-
Liquid chromatography-mass spectrometry in peptide drug discovery and development
-
John H. Liquid chromatography-mass spectrometry in peptide drug discovery and development. Anal. Bioanal. Chem. 2005, 381:51-53.
-
(2005)
Anal. Bioanal. Chem.
, vol.381
, pp. 51-53
-
-
John, H.1
-
2
-
-
84874979476
-
Liquid chromatography coupled with tandem mass spectrometry for the bioanalysis of proteins in drug development: practical considerations in assay development and validation
-
Liu G., Ji Q.C., Dodge R., Sun H., Shuster D., Zhao Q., Arnold M. Liquid chromatography coupled with tandem mass spectrometry for the bioanalysis of proteins in drug development: practical considerations in assay development and validation. J. Chromatogr. A 2013, 1284:155-162.
-
(2013)
J. Chromatogr. A
, vol.1284
, pp. 155-162
-
-
Liu, G.1
Ji, Q.C.2
Dodge, R.3
Sun, H.4
Shuster, D.5
Zhao, Q.6
Arnold, M.7
-
4
-
-
79958751966
-
The absolute quantification of endogenous levels of brain neuropeptides in vivo using LC-MS/MS
-
Van Eeckhaut A., Maes K., Aourz N., Smolders I., Michotte Y. The absolute quantification of endogenous levels of brain neuropeptides in vivo using LC-MS/MS. Bioanalysis 2011, 3:1271-1285.
-
(2011)
Bioanalysis
, vol.3
, pp. 1271-1285
-
-
Van Eeckhaut, A.1
Maes, K.2
Aourz, N.3
Smolders, I.4
Michotte, Y.5
-
5
-
-
0038714965
-
Neuropeptides: opportunities for drug discovery
-
Hokfelt T., Bartfai T., Bloom F. Neuropeptides: opportunities for drug discovery. Lancet Neurol. 2003, 2:463-472.
-
(2003)
Lancet Neurol.
, vol.2
, pp. 463-472
-
-
Hokfelt, T.1
Bartfai, T.2
Bloom, F.3
-
7
-
-
84870227585
-
Neuropeptides as therapeutic targets in anxiety disorders
-
Lin E.J. Neuropeptides as therapeutic targets in anxiety disorders. Curr. Pharm. Des. 2012, 18:5709-5727.
-
(2012)
Curr. Pharm. Des.
, vol.18
, pp. 5709-5727
-
-
Lin, E.J.1
-
8
-
-
70350539236
-
Neuropeptides: relevance in treatment of depression and anxiety disorders
-
Madaan V., Wilson D.R. Neuropeptides: relevance in treatment of depression and anxiety disorders. Drug News Perspect. 2009, 22:319-324.
-
(2009)
Drug News Perspect.
, vol.22
, pp. 319-324
-
-
Madaan, V.1
Wilson, D.R.2
-
9
-
-
33748100237
-
Neuropeptidergic regulation of affiliative behavior and social bonding in animals
-
Lim M.M., Young L.J. Neuropeptidergic regulation of affiliative behavior and social bonding in animals. Horm. Behav. 2006, 50:506-517.
-
(2006)
Horm. Behav.
, vol.50
, pp. 506-517
-
-
Lim, M.M.1
Young, L.J.2
-
10
-
-
84863866948
-
Multiple roles for orexin/hypocretin in addiction
-
Mahler S.V., Smith R.J., Moorman D.E., Sartor G.C., Aston-Jones G. Multiple roles for orexin/hypocretin in addiction. Prog. Brain Res. 2012, 198:79-121.
-
(2012)
Prog. Brain Res.
, vol.198
, pp. 79-121
-
-
Mahler, S.V.1
Smith, R.J.2
Moorman, D.E.3
Sartor, G.C.4
Aston-Jones, G.5
-
11
-
-
84859420695
-
Ghrelin: an emerging new anticonvulsant neuropeptide
-
Portelli J., Michotte Y., Smolders I. Ghrelin: an emerging new anticonvulsant neuropeptide. Epilepsia 2012, 53:585-595.
-
(2012)
Epilepsia
, vol.53
, pp. 585-595
-
-
Portelli, J.1
Michotte, Y.2
Smolders, I.3
-
12
-
-
79958750098
-
Neuropeptides: epilepsy
-
Elsevier, Amsterdam, The Netherlands, L.R. Squire (Ed.)
-
Mazarati A. Neuropeptides: epilepsy. Encyclopedia of Neuroscience 2009, 907-914. Elsevier, Amsterdam, The Netherlands. L.R. Squire (Ed.).
-
(2009)
Encyclopedia of Neuroscience
, pp. 907-914
-
-
Mazarati, A.1
-
13
-
-
84856103580
-
Peptide therapeutics for CNS indications
-
McGonigle P. Peptide therapeutics for CNS indications. Biochem. Pharmacol. 2012, 83:559-566.
-
(2012)
Biochem. Pharmacol.
, vol.83
, pp. 559-566
-
-
McGonigle, P.1
-
14
-
-
84879462142
-
Analysis of biopharmaceutical proteins in biological matrices by LC-MS/MS II. LC-MS/MS analysis
-
Hopfgartner
-
Hopfgartner Analysis of biopharmaceutical proteins in biological matrices by LC-MS/MS II. LC-MS/MS analysis. Trend. Anal. Chem. 2013, 48:52-61.
-
(2013)
Trend. Anal. Chem.
, vol.48
, pp. 52-61
-
-
-
15
-
-
0742269697
-
Adsorption of the decapeptide Cetrorelix depends both on the composition of dissolution medium and the type of solid surface
-
Grohganz H., Rischer M., Brandl M. Adsorption of the decapeptide Cetrorelix depends both on the composition of dissolution medium and the type of solid surface. Eur. J. Pharm. Sci. 2004, 21:191-196.
-
(2004)
Eur. J. Pharm. Sci.
, vol.21
, pp. 191-196
-
-
Grohganz, H.1
Rischer, M.2
Brandl, M.3
-
16
-
-
33847359572
-
Improvement of recovery and repeatability in liquid chromatography-mass spectrometry analysis of peptides
-
van Midwoud P.M., Rieux L., Bischoff R., Verpoorte E., Niederlander H.A. Improvement of recovery and repeatability in liquid chromatography-mass spectrometry analysis of peptides. J. Proteome Res. 2007, 6:781-791.
-
(2007)
J. Proteome Res.
, vol.6
, pp. 781-791
-
-
van Midwoud, P.M.1
Rieux, L.2
Bischoff, R.3
Verpoorte, E.4
Niederlander, H.A.5
-
17
-
-
84871426261
-
Investigation of carryover of peptides in nano-liquid chromatography/mass spectrometry using packed and monolithic capillary columns
-
Dolman S., Eeltink S., Vaast A., Pelzing M. Investigation of carryover of peptides in nano-liquid chromatography/mass spectrometry using packed and monolithic capillary columns. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2013, 912:56-63.
-
(2013)
J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci.
, vol.912
, pp. 56-63
-
-
Dolman, S.1
Eeltink, S.2
Vaast, A.3
Pelzing, M.4
-
18
-
-
38849144761
-
Determination of carryover and contamination for mass spectrometry-based chromatographic assays
-
Hughes N.C., Wong E.Y., Fan J., Bajaj N. Determination of carryover and contamination for mass spectrometry-based chromatographic assays. AAPS J. 2007, 9:353-360.
-
(2007)
AAPS J.
, vol.9
, pp. 353-360
-
-
Hughes, N.C.1
Wong, E.Y.2
Fan, J.3
Bajaj, N.4
-
19
-
-
84856035228
-
An alternative solution to overcome carryover issues in bioanalysis
-
Morin L.P., Taillon M.P., Furtado M., Garofolo F. An alternative solution to overcome carryover issues in bioanalysis. Bioanalysis 2012, 4:133-141.
-
(2012)
Bioanalysis
, vol.4
, pp. 133-141
-
-
Morin, L.P.1
Taillon, M.P.2
Furtado, M.3
Garofolo, F.4
-
20
-
-
33745894987
-
A novel approach for in-process monitoring and managing cross-contamination in a high-throughput high-performance liquid chromatography assay with tandem mass spectrometric detection
-
Chang M.S., Kim E.J., El-Shourbagy T.A. A novel approach for in-process monitoring and managing cross-contamination in a high-throughput high-performance liquid chromatography assay with tandem mass spectrometric detection. Rapid Commun. Mass Spectrom. 2006, 20:2190-2200.
-
(2006)
Rapid Commun. Mass Spectrom.
, vol.20
, pp. 2190-2200
-
-
Chang, M.S.1
Kim, E.J.2
El-Shourbagy, T.A.3
-
21
-
-
67650735898
-
Preventing carryover of peptides and proteins in nano LC-MS separations
-
Mitulovic G., Stingl C., Steinmacher I., Hudecz O., Hutchins J.R., Peters J.M., Mechtler K. Preventing carryover of peptides and proteins in nano LC-MS separations. Anal. Chem. 2009, 81:5955-5960.
-
(2009)
Anal. Chem.
, vol.81
, pp. 5955-5960
-
-
Mitulovic, G.1
Stingl, C.2
Steinmacher, I.3
Hudecz, O.4
Hutchins, J.R.5
Peters, J.M.6
Mechtler, K.7
-
22
-
-
32544444858
-
A new approach for evaluating carryover and its influence on quantitation in high-performance liquid chromatography and tandem mass spectrometry assay
-
Zeng W., Musson D.G., Fisher A.L., Wang A.Q. A new approach for evaluating carryover and its influence on quantitation in high-performance liquid chromatography and tandem mass spectrometry assay. Rapid Commun. Mass Spectrom. 2006, 20:635-640.
-
(2006)
Rapid Commun. Mass Spectrom.
, vol.20
, pp. 635-640
-
-
Zeng, W.1
Musson, D.G.2
Fisher, A.L.3
Wang, A.Q.4
-
23
-
-
67650133971
-
Validation of bioanalytical LC-MS/MS assays: evaluation of matrix effects
-
Van Eeckhaut A., Lanckmans K., Sarre S., Smolders I., Michotte Y. Validation of bioanalytical LC-MS/MS assays: evaluation of matrix effects. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2009, 877:2198-2207.
-
(2009)
J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci.
, vol.877
, pp. 2198-2207
-
-
Van Eeckhaut, A.1
Lanckmans, K.2
Sarre, S.3
Smolders, I.4
Michotte, Y.5
-
24
-
-
81055146012
-
-
EMA, London, United Kingdom, (accessed January 21, 2014), EMA (Ed.), EMA
-
EMA Guideline on Bioanalytical Method Validation 2011, EMA, London, United Kingdom, Available at http://www.ema.europa.eu/docs/en_GB/document_library/Scientific_guideline/2011/08/WC500109686.pdf (accessed January 21, 2014). EMA (Ed.).
-
(2011)
Guideline on Bioanalytical Method Validation
-
-
-
25
-
-
11144302045
-
Elimination of autosampler carryover in a bioanalytical HPLC-MS/MS method: a case study
-
Vallano P.T., Shugarts S.B., Woolf E.J., Matuszewski B.K. Elimination of autosampler carryover in a bioanalytical HPLC-MS/MS method: a case study. J. Pharm. Biomed. Anal. 2005, 36:1073-1078.
-
(2005)
J. Pharm. Biomed. Anal.
, vol.36
, pp. 1073-1078
-
-
Vallano, P.T.1
Shugarts, S.B.2
Woolf, E.J.3
Matuszewski, B.K.4
-
26
-
-
59649101292
-
Separation, detection and quantitation of peptides by liquid chromatography and capillary electrochromatography
-
Issaq H.J., Chan K.C., Blonder J., Ye X., Veenstra T.D. Separation, detection and quantitation of peptides by liquid chromatography and capillary electrochromatography. J. Chromatogr. A 2009, 1216:1825-1837.
-
(2009)
J. Chromatogr. A
, vol.1216
, pp. 1825-1837
-
-
Issaq, H.J.1
Chan, K.C.2
Blonder, J.3
Ye, X.4
Veenstra, T.D.5
-
27
-
-
84905747951
-
-
Sigma-Aldrich, USA, (accessed December 14, 2013), Sigma-Aldrich (Ed.), Sigma-Aldrich
-
Sigma-Aldrich Storage and Handling Synthetic Peptides: Guidelines 2005, Sigma-Aldrich, USA, Available at http://www.sigmaaldrich.com/content/dam/sigma-aldrich/docs/SAJ/Brochure/1/71683-synthetic-peptide-storage-handling-guide.pdf. (accessed December 14, 2013). Sigma-Aldrich (Ed.).
-
(2005)
Storage and Handling Synthetic Peptides: Guidelines
-
-
-
28
-
-
11944271430
-
Solubility as a function of protein structure and solvent components
-
Schein C.H. Solubility as a function of protein structure and solvent components. Biotechnology (N.Y.) 1990, 8:308-317.
-
(1990)
Biotechnology (N.Y.)
, vol.8
, pp. 308-317
-
-
Schein, C.H.1
-
29
-
-
0035233582
-
Electrospray mass spectrometry of hydrophobic compounds using dimethyl sulfoxide and dimethylformamide as solvents
-
Szabo P.T., Kele Z. Electrospray mass spectrometry of hydrophobic compounds using dimethyl sulfoxide and dimethylformamide as solvents. Rapid Commun. Mass Spectrom. 2001, 15:2415-2419.
-
(2001)
Rapid Commun. Mass Spectrom.
, vol.15
, pp. 2415-2419
-
-
Szabo, P.T.1
Kele, Z.2
-
30
-
-
0015589976
-
Oxidation of amino acids by dimethyl sulfoxide
-
Lipton S.H., Bodwell C.E. Oxidation of amino acids by dimethyl sulfoxide. J. Agric. Food Chem. 1973, 21:235-237.
-
(1973)
J. Agric. Food Chem.
, vol.21
, pp. 235-237
-
-
Lipton, S.H.1
Bodwell, C.E.2
-
31
-
-
0022625343
-
Selective oxidation and reduction of methionine residues in peptides and proteins by oxygen exchange between sulfoxide and sulfide
-
Shechter Y. Selective oxidation and reduction of methionine residues in peptides and proteins by oxygen exchange between sulfoxide and sulfide. J. Biol. Chem. 1986, 261:66-70.
-
(1986)
J. Biol. Chem.
, vol.261
, pp. 66-70
-
-
Shechter, Y.1
-
32
-
-
13444250137
-
Determination of pharmaceutical compounds in aqueous dimethyl sulfoxide by electrospray ionization mass spectrometry
-
Borges V., Henion J. Determination of pharmaceutical compounds in aqueous dimethyl sulfoxide by electrospray ionization mass spectrometry. Rapid Commun. Mass Spectrom. 2005, 19:415-423.
-
(2005)
Rapid Commun. Mass Spectrom.
, vol.19
, pp. 415-423
-
-
Borges, V.1
Henion, J.2
-
33
-
-
84871539893
-
Development of a fast method for direct analysis of intact synthetic insulins in human plasma: the large peptide challenge
-
Chambers E.E., Legido-Quigley C., Smith N., Fountain K.J. Development of a fast method for direct analysis of intact synthetic insulins in human plasma: the large peptide challenge. Bioanalysis 2013, 5:65-81.
-
(2013)
Bioanalysis
, vol.5
, pp. 65-81
-
-
Chambers, E.E.1
Legido-Quigley, C.2
Smith, N.3
Fountain, K.J.4
-
34
-
-
0035009229
-
The effect of net charge on the solubility, activity, and stability of ribonuclease Sa
-
Shaw K.L., Grimsley G.R., Yakovlev G.I., Makarov A.A., Pace C.N. The effect of net charge on the solubility, activity, and stability of ribonuclease Sa. Protein Sci. 2001, 10:1206-1215.
-
(2001)
Protein Sci.
, vol.10
, pp. 1206-1215
-
-
Shaw, K.L.1
Grimsley, G.R.2
Yakovlev, G.I.3
Makarov, A.A.4
Pace, C.N.5
-
35
-
-
0141746349
-
The role of protein stability, solubility, and net charge in amyloid fibril formation
-
Schmittschmitt J.P., Scholtz J.M. The role of protein stability, solubility, and net charge in amyloid fibril formation. Protein Sci. 2003, 12:2374-2378.
-
(2003)
Protein Sci.
, vol.12
, pp. 2374-2378
-
-
Schmittschmitt, J.P.1
Scholtz, J.M.2
-
36
-
-
84905747952
-
-
Improved sensitivity of the nano ultra-high performance liquid chromatography-tanden mass spectrometric analysis of low-concentrated neuropeptides by reducing aspecific adsorption and optimizing the injection solvent, research paper submitted for publication.
-
K. Maes, J. Van Liefferinge, J. Viaene, J. Van Schoors, Y. Van Wanseele, G. Béchade, E.E. Chambers, H. Morren, Y. Michotte, Y. Vander Heyden, J. Claereboudt, I. Smolders, A. Van Eeckhaut, Improved sensitivity of the nano ultra-high performance liquid chromatography-tanden mass spectrometric analysis of low-concentrated neuropeptides by reducing aspecific adsorption and optimizing the injection solvent, research paper submitted for publication.
-
-
-
Maes, K.1
Van Liefferinge, J.2
Viaene, J.3
Van Schoors, J.4
Van Wanseele, Y.5
Béchade, G.6
Chambers, E.E.7
Morren, H.8
Michotte, Y.9
Vander Heyden, Y.10
Claereboudt, J.11
Smolders, I.12
Van Eeckhaut, A.13
-
37
-
-
84871509248
-
Screening nonspecific interactions of peptides without background interference
-
Keefe A.J., Caldwell K.B., Nowinski A.K., White A.D., Thakkar A., Jiang S. Screening nonspecific interactions of peptides without background interference. Biomaterials 2013, 34:1871-1877.
-
(2013)
Biomaterials
, vol.34
, pp. 1871-1877
-
-
Keefe, A.J.1
Caldwell, K.B.2
Nowinski, A.K.3
White, A.D.4
Thakkar, A.5
Jiang, S.6
-
38
-
-
7044240014
-
Analytical procedures for quantification of peptides in pharmaceutical research by liquid chromatography-mass spectrometry
-
John H., Walden M., Schafer S., Genz S., Forssmann W.G. Analytical procedures for quantification of peptides in pharmaceutical research by liquid chromatography-mass spectrometry. Anal. Bioanal. Chem. 2004, 378:883-897.
-
(2004)
Anal. Bioanal. Chem.
, vol.378
, pp. 883-897
-
-
John, H.1
Walden, M.2
Schafer, S.3
Genz, S.4
Forssmann, W.G.5
-
39
-
-
0034899345
-
Effects of adsorption to plastics and solvent conditions in the analysis of the cyanobacterial toxin microcystin-LR by high performance liquid chromatography
-
Hyenstrand P., Metcalf J.S., Beattie K.A., Codd G.A. Effects of adsorption to plastics and solvent conditions in the analysis of the cyanobacterial toxin microcystin-LR by high performance liquid chromatography. Water Res. 2001, 35:3508-3511.
-
(2001)
Water Res.
, vol.35
, pp. 3508-3511
-
-
Hyenstrand, P.1
Metcalf, J.S.2
Beattie, K.A.3
Codd, G.A.4
-
40
-
-
0343279072
-
Losses of the cyanobacterial toxin microcystin-LR from aqueous solution by adsorption during laboratory manipulations
-
Hyenstrand P., Metcalf J.S., Beattie K.A., Codd G.A. Losses of the cyanobacterial toxin microcystin-LR from aqueous solution by adsorption during laboratory manipulations. Toxicon 2001, 39:589-594.
-
(2001)
Toxicon
, vol.39
, pp. 589-594
-
-
Hyenstrand, P.1
Metcalf, J.S.2
Beattie, K.A.3
Codd, G.A.4
-
41
-
-
79951896736
-
A screening UHPLC-MS/MS method for the analysis of amyloid peptides in cerebrospinal fluid of preclinical species
-
Dillen L., Cools W., Vereyken L., Timmerman P. A screening UHPLC-MS/MS method for the analysis of amyloid peptides in cerebrospinal fluid of preclinical species. Bioanalysis 2011, 3:45-55.
-
(2011)
Bioanalysis
, vol.3
, pp. 45-55
-
-
Dillen, L.1
Cools, W.2
Vereyken, L.3
Timmerman, P.4
-
42
-
-
77955897878
-
Comparison between a linear ion trap and a triple quadruple MS in the sensitive detection of large peptides at femtomole amounts on column
-
Vatansever B., Lahrichi S.L., Thiocone A., Salluce N., Mathieu M., Grouzmann E., Rochat B. Comparison between a linear ion trap and a triple quadruple MS in the sensitive detection of large peptides at femtomole amounts on column. J. Sep. Sci. 2010, 33:2478-2488.
-
(2010)
J. Sep. Sci.
, vol.33
, pp. 2478-2488
-
-
Vatansever, B.1
Lahrichi, S.L.2
Thiocone, A.3
Salluce, N.4
Mathieu, M.5
Grouzmann, E.6
Rochat, B.7
-
43
-
-
79954631167
-
False EX1 signatures caused by sample carryover during HX MS analyses
-
Fang J., Rand K.D., Beuning P.J., Engen J.R. False EX1 signatures caused by sample carryover during HX MS analyses. Int. J. Mass Spectrom. 2011, 302:19-25.
-
(2011)
Int. J. Mass Spectrom.
, vol.302
, pp. 19-25
-
-
Fang, J.1
Rand, K.D.2
Beuning, P.J.3
Engen, J.R.4
-
44
-
-
33845591072
-
Quantitative analysis of amyloid beta peptides in cerebrospinal fluid of Alzheimer's disease patients by immunoaffinity purification and stable isotope dilution liquid chromatography/negative electrospray ionization tandem mass spectrometry
-
Oe T., Ackermann B.L., Inoue K., Berna M.J., Garner C.O., Gelfanova V., Dean R.A., Siemers E.R., Holtzman D.M., Farlow M.R., Blair I.A. Quantitative analysis of amyloid beta peptides in cerebrospinal fluid of Alzheimer's disease patients by immunoaffinity purification and stable isotope dilution liquid chromatography/negative electrospray ionization tandem mass spectrometry. Rapid Commun. Mass Spectrom. 2006, 20:3723-3735.
-
(2006)
Rapid Commun. Mass Spectrom.
, vol.20
, pp. 3723-3735
-
-
Oe, T.1
Ackermann, B.L.2
Inoue, K.3
Berna, M.J.4
Garner, C.O.5
Gelfanova, V.6
Dean, R.A.7
Siemers, E.R.8
Holtzman, D.M.9
Farlow, M.R.10
Blair, I.A.11
-
45
-
-
0037025842
-
Simple liquid chromatography-electrospray ionization mass spectrometry method for the routine determination of salmon calcitonin in serum
-
Song K.H., An H.M., Kim H.J., Ahn S.H., Chung S.J., Shim C.K. Simple liquid chromatography-electrospray ionization mass spectrometry method for the routine determination of salmon calcitonin in serum. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2002, 775:247-255.
-
(2002)
J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci.
, vol.775
, pp. 247-255
-
-
Song, K.H.1
An, H.M.2
Kim, H.J.3
Ahn, S.H.4
Chung, S.J.5
Shim, C.K.6
-
46
-
-
84905747953
-
-
Inaccuracies in quantification of peptides - a case study using beta endorphin assay, in: LCGC (Ed.), USA, (accessed January 30 2014).
-
H.M.D.R. Herath, R.-R. Kim, P.J., Cabot, P.N., Shaw, A.K. Hewavitharana, Inaccuracies in quantification of peptides - a case study using beta endorphin assay, in: LCGC (Ed.), USA, 2013, Available at http://www.chromatographyonline.com/lcgc/Article/Inaccuracies (accessed January 30 2014).
-
(2013)
-
-
Herath, H.M.D.R.1
Kim, R.-R.2
Cabot, P.J.3
Shaw, P.N.4
Hewavitharana, A.K.5
-
47
-
-
0029942251
-
Effects of amino acid composition on protein adsorption
-
Malmsten M., Veide A. Effects of amino acid composition on protein adsorption. J. Colloid Interface Sci. 1996, 178:160-167.
-
(1996)
J. Colloid Interface Sci.
, vol.178
, pp. 160-167
-
-
Malmsten, M.1
Veide, A.2
-
48
-
-
0024544308
-
Adsorption of proteins onto glass surfaces and its effect on the intensity of circular dichroism spectra
-
Wu C.S., Chen G.C. Adsorption of proteins onto glass surfaces and its effect on the intensity of circular dichroism spectra. Anal. Biochem. 1989, 177:178-182.
-
(1989)
Anal. Biochem.
, vol.177
, pp. 178-182
-
-
Wu, C.S.1
Chen, G.C.2
-
49
-
-
0026759816
-
The adsorption of proteins to pharmaceutical container surfaces
-
Burke C.J., Steadman B.L., Volkin D.B., Tsai P.K., Bruner M.W., Middaugh C.R. The adsorption of proteins to pharmaceutical container surfaces. Int. J. Pharm. 1992, 86:89-93.
-
(1992)
Int. J. Pharm.
, vol.86
, pp. 89-93
-
-
Burke, C.J.1
Steadman, B.L.2
Volkin, D.B.3
Tsai, P.K.4
Bruner, M.W.5
Middaugh, C.R.6
-
50
-
-
0026154124
-
The effect of pH and NaCl concentration on adsorption of beta-lactoglobulin at hydrophilic and hydrophobic silicon surfaces
-
Luey J.K., Mcguire J., Sproull R.D. The effect of pH and NaCl concentration on adsorption of beta-lactoglobulin at hydrophilic and hydrophobic silicon surfaces. J. Colloid Interface Sci. 1991, 143:489-500.
-
(1991)
J. Colloid Interface Sci.
, vol.143
, pp. 489-500
-
-
Luey, J.K.1
Mcguire, J.2
Sproull, R.D.3
-
51
-
-
0030532365
-
Driving forces for protein adsorption at solid surfaces
-
Norde W. Driving forces for protein adsorption at solid surfaces. Macromol. Symp. 1996, 103:5-18.
-
(1996)
Macromol. Symp.
, vol.103
, pp. 5-18
-
-
Norde, W.1
-
52
-
-
36349018372
-
Differential recovery of peptides from sample tubes and the reproducibility of quantitative proteomic data
-
Bark S.J., Hook V. Differential recovery of peptides from sample tubes and the reproducibility of quantitative proteomic data. J. Proteome Res. 2007, 6:4511-4516.
-
(2007)
J. Proteome Res.
, vol.6
, pp. 4511-4516
-
-
Bark, S.J.1
Hook, V.2
-
53
-
-
67650400627
-
Peptide storage: are you getting the best return on your investment? Defining optimal storage conditions for proteomics samples
-
Kraut A., Marcellin M., Adrait A., Kuhn L., Louwagie M., Kieffer-Jaquinod S., Lebert D., Masselon C.D., Dupuis A., Bruley C., Jaquinod M., Garin J., Gallagher-Gambarelli M. Peptide storage: are you getting the best return on your investment? Defining optimal storage conditions for proteomics samples. J. Proteome Res. 2009, 8:3778-3785.
-
(2009)
J. Proteome Res.
, vol.8
, pp. 3778-3785
-
-
Kraut, A.1
Marcellin, M.2
Adrait, A.3
Kuhn, L.4
Louwagie, M.5
Kieffer-Jaquinod, S.6
Lebert, D.7
Masselon, C.D.8
Dupuis, A.9
Bruley, C.10
Jaquinod, M.11
Garin, J.12
Gallagher-Gambarelli, M.13
-
54
-
-
84905747947
-
-
(accessed January 30, 2014), LCGC (Ed.)
-
Dolan J.W. Autosamplers Part II-Problems and Solutions 2001, Available at http://www.chromatographyonline.com/lcgc/data/articlestandard/lcgceurope/182002/18099/article.pdf (accessed January 30, 2014). LCGC (Ed.).
-
(2001)
Autosamplers Part II-Problems and Solutions
-
-
Dolan, J.W.1
-
55
-
-
14744296383
-
Concerns in the development of an assay for determination of a highly conjugated adsorption-prone compound in human urine
-
Xu Y., Du L., Rose M.J., Fu I., Woolf E.J., Musson D.G. Concerns in the development of an assay for determination of a highly conjugated adsorption-prone compound in human urine. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2005, 818:241-248.
-
(2005)
J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci.
, vol.818
, pp. 241-248
-
-
Xu, Y.1
Du, L.2
Rose, M.J.3
Fu, I.4
Woolf, E.J.5
Musson, D.G.6
-
56
-
-
75349107582
-
Quantitative determination of BAF312, a S1P-R modulator, in human urine by LC-MS/MS: prevention and recovery of lost analyte due to container surface adsorption
-
Li W., Luo S., Smith H.T., Tse F.L. Quantitative determination of BAF312, a S1P-R modulator, in human urine by LC-MS/MS: prevention and recovery of lost analyte due to container surface adsorption. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2010, 878:583-589.
-
(2010)
J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci.
, vol.878
, pp. 583-589
-
-
Li, W.1
Luo, S.2
Smith, H.T.3
Tse, F.L.4
-
57
-
-
0020854576
-
How to prevent losses of protein by adsorption to glass and plastic
-
Suelter C.H., DeLuca M. How to prevent losses of protein by adsorption to glass and plastic. Anal. Biochem. 1983, 135:112-119.
-
(1983)
Anal. Biochem.
, vol.135
, pp. 112-119
-
-
Suelter, C.H.1
DeLuca, M.2
-
58
-
-
75549085660
-
Quantitative assay for six potential breast cancer biomarker peptides in human serum by liquid chromatography coupled to tandem mass spectrometry
-
van den Broek I., Sparidans R.W., Schellens J.H., Beijnen J.H. Quantitative assay for six potential breast cancer biomarker peptides in human serum by liquid chromatography coupled to tandem mass spectrometry. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2008, 878:590-602.
-
(2008)
J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci.
, vol.878
, pp. 590-602
-
-
van den Broek, I.1
Sparidans, R.W.2
Schellens, J.H.3
Beijnen, J.H.4
-
59
-
-
84867564254
-
Characterization of a fully automated nanoelectrospray system with mass spectrometric detection for proteomic analyses
-
Van Pelt C.K., Zhang S., Henion J.D. Characterization of a fully automated nanoelectrospray system with mass spectrometric detection for proteomic analyses. J. Biomol. Tech. 2002, 13:72-84.
-
(2002)
J. Biomol. Tech.
, vol.13
, pp. 72-84
-
-
Van Pelt, C.K.1
Zhang, S.2
Henion, J.D.3
-
60
-
-
0033007820
-
Adsorption of calcitonin to glass
-
Law S.L., Shih C.L. Adsorption of calcitonin to glass. Drug Dev. Ind. Pharm. 1999, 25:253-256.
-
(1999)
Drug Dev. Ind. Pharm.
, vol.25
, pp. 253-256
-
-
Law, S.L.1
Shih, C.L.2
-
62
-
-
0000422031
-
Quantitative-analysis by high-performance liquid-chromatography atmospheric-pressure chemical ionization mass-spectrometry-the determination of the renin inhibitor Cp-80,794 in human serum
-
Fouda H., Nocerini M., Schneider R., Gedutis C. Quantitative-analysis by high-performance liquid-chromatography atmospheric-pressure chemical ionization mass-spectrometry-the determination of the renin inhibitor Cp-80,794 in human serum. J. Am. Soc. Mass Spectrom. 1991, 2:164-167.
-
(1991)
J. Am. Soc. Mass Spectrom.
, vol.2
, pp. 164-167
-
-
Fouda, H.1
Nocerini, M.2
Schneider, R.3
Gedutis, C.4
-
63
-
-
84905747949
-
-
(accessed December 28, 2014), Dionex (Ed.), Australia
-
Cowie C., Karsten M., Sneekes E.J., Swart R. Reduction of Sample Carryover in Proteomics LC-MS Experiments Australia, 2010, Available at http://www.dionex.com/en-us/webdocs/87155-PO-RSLCnano-CarryoverinProteomics-13Mar2011-LPN2781-01.pdf (accessed December 28, 2014). Dionex (Ed.).
-
(2010)
Reduction of Sample Carryover in Proteomics LC-MS Experiments
-
-
Cowie, C.1
Karsten, M.2
Sneekes, E.J.3
Swart, R.4
-
64
-
-
0035346719
-
Interrogating the human genome using uninterpreted mass spectrometry data
-
Choudhary J.S., Blackstock W.P., Creasy D.M., Cottrell J.S. Interrogating the human genome using uninterpreted mass spectrometry data. Proteomics 2001, 1:651-667.
-
(2001)
Proteomics
, vol.1
, pp. 651-667
-
-
Choudhary, J.S.1
Blackstock, W.P.2
Creasy, D.M.3
Cottrell, J.S.4
-
65
-
-
0037008238
-
Temperature selectivity in reversed-phase high performance liquid chromatography
-
Dolan J.W. Temperature selectivity in reversed-phase high performance liquid chromatography. J. Chromatogr. A 2002, 965:195-205.
-
(2002)
J. Chromatogr. A
, vol.965
, pp. 195-205
-
-
Dolan, J.W.1
-
66
-
-
84861349591
-
Universal LC-MS method for minimized carryover in a discovery bioanalytical setting
-
Williams J.S., Donahue S.H., Gao H., Brummel C.L. Universal LC-MS method for minimized carryover in a discovery bioanalytical setting. Bioanalysis 2012, 4:1025-1037.
-
(2012)
Bioanalysis
, vol.4
, pp. 1025-1037
-
-
Williams, J.S.1
Donahue, S.H.2
Gao, H.3
Brummel, C.L.4
-
67
-
-
33744999435
-
High recovery HPLC separation of lipid rafts for membrane proteome analysis
-
Martosella J., Zolotarjova N., Liu H., Moyer S.C., Perkins P.D., Boyes B.E. High recovery HPLC separation of lipid rafts for membrane proteome analysis. J. Proteome Res. 2006, 5:1301-1312.
-
(2006)
J. Proteome Res.
, vol.5
, pp. 1301-1312
-
-
Martosella, J.1
Zolotarjova, N.2
Liu, H.3
Moyer, S.C.4
Perkins, P.D.5
Boyes, B.E.6
-
68
-
-
84873043152
-
Troubleshooting carry-over of LC-MS/MS method for rifampicin, clarithromycin and metabolites in human plasma
-
Vu D.H., Koster R.A., Wessels A.M.A., Greijdanus B., Alffenaar J.W.C., Uges D.R.A. Troubleshooting carry-over of LC-MS/MS method for rifampicin, clarithromycin and metabolites in human plasma. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2013, 917:1-4.
-
(2013)
J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci.
, vol.917
, pp. 1-4
-
-
Vu, D.H.1
Koster, R.A.2
Wessels, A.M.A.3
Greijdanus, B.4
Alffenaar, J.W.C.5
Uges, D.R.A.6
-
69
-
-
30344460017
-
Determination of bradykinin and arg-bradykinin in rat muscle tissue by microdialysis and capillary column-switching liquid chromatography with mass spectrometric detection
-
Wilson S.R., Boix F., Holm A., Molander P., Lundanes E., Greibrokk T. Determination of bradykinin and arg-bradykinin in rat muscle tissue by microdialysis and capillary column-switching liquid chromatography with mass spectrometric detection. J. Sep. Sci. 2005, 28:1751-1758.
-
(2005)
J. Sep. Sci.
, vol.28
, pp. 1751-1758
-
-
Wilson, S.R.1
Boix, F.2
Holm, A.3
Molander, P.4
Lundanes, E.5
Greibrokk, T.6
-
70
-
-
44949092197
-
-
(accessed January 30, 2014), LCGC (Ed.)
-
Dolan J.W. Autosampler carryover: why is the blank never clean 2006, Available at http://www.chromatographyonline.com/lcgc/Column%3A+LC+Troubleshooting/Autosampler-Carryover/ArticleStandard/Article/detail/377221 (accessed January 30, 2014). LCGC (Ed.).
-
(2006)
Autosampler carryover: why is the blank never clean
-
-
Dolan, J.W.1
-
71
-
-
84905747943
-
-
(accessed January 30, 2014), LCGC (Ed.)
-
Dolan J.W. Autosamplers Part I-Design Features 2001, Available at http://www.chromatographyonline.com/lcgc/data/articlestandard/lcgceurope/182002/18089/article.pdf (accessed January 30, 2014). LCGC (Ed.).
-
(2001)
Autosamplers Part I-Design Features
-
-
Dolan, J.W.1
-
72
-
-
44949170485
-
-
(accessed January 30, 2014), LCGC (Ed.)
-
Dolan J.W. Autosampler Carryover 2001, Available at http://www.chromatographyonline.com/lcgc/data/articlestandard//lcgceurope/042002/7657/article.pdf (accessed January 30, 2014). LCGC (Ed.).
-
(2001)
Autosampler Carryover
-
-
Dolan, J.W.1
-
73
-
-
33947724473
-
Use of a structural analogue versus a stable isotope labeled internal standard for the quantification of angiotensin IV in rat brain dialysates using nano-liquid chromatography/tandem mass spectrometry
-
Lanckmans K., Sarre S., Smolders I., Michotte Y. Use of a structural analogue versus a stable isotope labeled internal standard for the quantification of angiotensin IV in rat brain dialysates using nano-liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom. 2007, 21:1187-1195.
-
(2007)
Rapid Commun. Mass Spectrom.
, vol.21
, pp. 1187-1195
-
-
Lanckmans, K.1
Sarre, S.2
Smolders, I.3
Michotte, Y.4
-
74
-
-
0344212101
-
An improved method for tracking and reducing the void volume in nano HPLC-MS with micro trapping columns
-
Mitulovic G., Smoluch M., Chervet J.P., Steinmacher I., Kungl A., Mechtler K. An improved method for tracking and reducing the void volume in nano HPLC-MS with micro trapping columns. Anal. Bioanal. Chem. 2003, 376:946-951.
-
(2003)
Anal. Bioanal. Chem.
, vol.376
, pp. 946-951
-
-
Mitulovic, G.1
Smoluch, M.2
Chervet, J.P.3
Steinmacher, I.4
Kungl, A.5
Mechtler, K.6
-
75
-
-
33645462429
-
Two-dimensional reverse phase-reverse phase chromatography: a simple and robust platform for sensitive quantitative analysis of peptides by LC/MS. Hardware design
-
Rogatsky E., Stein D.T. Two-dimensional reverse phase-reverse phase chromatography: a simple and robust platform for sensitive quantitative analysis of peptides by LC/MS. Hardware design. J. Sep. Sci. 2006, 29:538-546.
-
(2006)
J. Sep. Sci.
, vol.29
, pp. 538-546
-
-
Rogatsky, E.1
Stein, D.T.2
-
76
-
-
26844575524
-
Reversed-phase high-performance liquid chromatographic prefractionation of immunodepleted human serum proteins to enhance mass spectrometry identification of lower-abundant proteins
-
Martosella J., Zolotarjova N., Liu H., Nicol G., Boyes B.E. Reversed-phase high-performance liquid chromatographic prefractionation of immunodepleted human serum proteins to enhance mass spectrometry identification of lower-abundant proteins. J. Proteome Res. 2005, 4:1522-1537.
-
(2005)
J. Proteome Res.
, vol.4
, pp. 1522-1537
-
-
Martosella, J.1
Zolotarjova, N.2
Liu, H.3
Nicol, G.4
Boyes, B.E.5
-
77
-
-
84905747944
-
-
(accessed December 22, 2013), Grace Vydac (Ed.), Grace Vydac
-
Grace Vydac Protein and Peptide Analysis and Purification 2011, Available at https://grace.com/pharma-and-biotech/en-us/Documents/Preparative%20and%20Process%20Purification/B562a_Vydac_Protein_and_Peptide_Handbook_LR_FINAL.pdf (accessed December 22, 2013). Grace Vydac (Ed.).
-
(2011)
Protein and Peptide Analysis and Purification
-
-
-
78
-
-
50049101979
-
Quantitative bioanalysis of peptides by liquid chromatography coupled to (tandem) mass spectrometry
-
van den Broek I., Sparidans R.W., Schellens J.H., Beijnen J.H. Quantitative bioanalysis of peptides by liquid chromatography coupled to (tandem) mass spectrometry. J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci. 2008, 872:1-22.
-
(2008)
J. Chromatogr. B: Analyt. Technol. Biomed. Life Sci.
, vol.872
, pp. 1-22
-
-
van den Broek, I.1
Sparidans, R.W.2
Schellens, J.H.3
Beijnen, J.H.4
-
79
-
-
84866235919
-
Impact of mobile phase temperature on recovery and stability of monoclonal antibodies using recent reversed-phase stationary phases
-
Fekete S., Rudaz S., Veuthey J.L., Guillarme D. Impact of mobile phase temperature on recovery and stability of monoclonal antibodies using recent reversed-phase stationary phases. J. Sep. Sci. 2012, 35:3113-3123.
-
(2012)
J. Sep. Sci.
, vol.35
, pp. 3113-3123
-
-
Fekete, S.1
Rudaz, S.2
Veuthey, J.L.3
Guillarme, D.4
-
80
-
-
42649113384
-
High speed gradient elution reversed phase liquid chromatography of bases in buffered eluents. Part II. Full equilibrium
-
Schellinger A.P., Stoll D.R., Carr P.W. High speed gradient elution reversed phase liquid chromatography of bases in buffered eluents. Part II. Full equilibrium. J. Chromatogr. A 2008, 1192:54-61.
-
(2008)
J. Chromatogr. A
, vol.1192
, pp. 54-61
-
-
Schellinger, A.P.1
Stoll, D.R.2
Carr, P.W.3
-
81
-
-
0028556343
-
Temperature as a variable in reversed-phase high-performance liquid chromatographic separations of peptide and protein samples. I. Optimizing the separation of a growth hormone tryptic digest
-
Hancock W.S., Chloupek R.C., Kirkland J.J., Snyder L.R. Temperature as a variable in reversed-phase high-performance liquid chromatographic separations of peptide and protein samples. I. Optimizing the separation of a growth hormone tryptic digest. J. Chromatogr. A 1994, 686:31-43.
-
(1994)
J. Chromatogr. A
, vol.686
, pp. 31-43
-
-
Hancock, W.S.1
Chloupek, R.C.2
Kirkland, J.J.3
Snyder, L.R.4
-
82
-
-
55749096879
-
Chromatographic benefits of elevated temperature for the proteomic analysis of membrane proteins
-
Blackler A.R., Speers A.E., Wu C.C. Chromatographic benefits of elevated temperature for the proteomic analysis of membrane proteins. Proteomics 2008, 8:3956-3964.
-
(2008)
Proteomics
, vol.8
, pp. 3956-3964
-
-
Blackler, A.R.1
Speers, A.E.2
Wu, C.C.3
-
83
-
-
34347234182
-
Shotgun analysis of integral membrane proteins facilitated by elevated temperature
-
Speers A.E., Blackler A.R., Wu C.C. Shotgun analysis of integral membrane proteins facilitated by elevated temperature. Anal. Chem. 2007, 79:4613-4620.
-
(2007)
Anal. Chem.
, vol.79
, pp. 4613-4620
-
-
Speers, A.E.1
Blackler, A.R.2
Wu, C.C.3
-
84
-
-
77951786429
-
Quantitative improvements in peptide recovery at elevated chromatographic temperatures from microcapillary liquid chromatography-mass spectrometry analyses of brain using selected reaction monitoring
-
Farias S., Kline K.G., Klepacki J., Wu C.C. Quantitative improvements in peptide recovery at elevated chromatographic temperatures from microcapillary liquid chromatography-mass spectrometry analyses of brain using selected reaction monitoring. Anal. Chem. 2010, 82:3435-3440.
-
(2010)
Anal. Chem.
, vol.82
, pp. 3435-3440
-
-
Farias, S.1
Kline, K.G.2
Klepacki, J.3
Wu, C.C.4
-
85
-
-
0027654617
-
Rapid High-resolution HPLC separation of peptides using small particles at elevated-temperatures
-
Boyes B.E., Kirkland J.J., Rapid High-resolution HPLC separation of peptides using small particles at elevated-temperatures. Pept. Res. 1993, 6:249-258.
-
(1993)
Pept. Res.
, vol.6
, pp. 249-258
-
-
Boyes, B.E.1
Kirkland, J.J.2
-
86
-
-
77953476888
-
New trends in fast and high-resolution liquid chromatography: a critical comparison of existing approaches
-
Guillarme D., Ruta J., Rudaz S., Veuthey J.L. New trends in fast and high-resolution liquid chromatography: a critical comparison of existing approaches. Anal. Bioanal. Chem. 2010, 397:1069-1082.
-
(2010)
Anal. Bioanal. Chem.
, vol.397
, pp. 1069-1082
-
-
Guillarme, D.1
Ruta, J.2
Rudaz, S.3
Veuthey, J.L.4
-
87
-
-
33644755630
-
Improved protein recovery in reversed-phase liquid chromatography by the use of ultrahigh pressures
-
Eschelbach J.W., Jorgenson J.W. Improved protein recovery in reversed-phase liquid chromatography by the use of ultrahigh pressures. Anal. Chem. 2006, 78:1697-1706.
-
(2006)
Anal. Chem.
, vol.78
, pp. 1697-1706
-
-
Eschelbach, J.W.1
Jorgenson, J.W.2
-
88
-
-
42649100987
-
Silanization of inner surfaces of nanoelectrospray ionization emitters for reduced analyte adsorption
-
Choi Y.S., Wood T.D. Silanization of inner surfaces of nanoelectrospray ionization emitters for reduced analyte adsorption. Rapid Commun. Mass Spectrom. 2008, 22:1265-1274.
-
(2008)
Rapid Commun. Mass Spectrom.
, vol.22
, pp. 1265-1274
-
-
Choi, Y.S.1
Wood, T.D.2
-
89
-
-
84879597199
-
Applications of selected reaction monitoring (SRM)-mass spectrometry (MS) for quantitative measurement of signaling pathways
-
Zhao Y., Brasier A.R. Applications of selected reaction monitoring (SRM)-mass spectrometry (MS) for quantitative measurement of signaling pathways. Methods 2013, 61:313-322.
-
(2013)
Methods
, vol.61
, pp. 313-322
-
-
Zhao, Y.1
Brasier, A.R.2
-
90
-
-
34548127563
-
A systematic evaluation of chip-based nanoelectrospray parameters for rapid identification of proteins from a complex mixture
-
Pereira-Medrano A.G., Sterling A., Snijders A.P., Reardon K.F., Wright P.C. A systematic evaluation of chip-based nanoelectrospray parameters for rapid identification of proteins from a complex mixture. J. Am. Soc. Mass Spectrom. 2007, 18:1714-1725.
-
(2007)
J. Am. Soc. Mass Spectrom.
, vol.18
, pp. 1714-1725
-
-
Pereira-Medrano, A.G.1
Sterling, A.2
Snijders, A.P.3
Reardon, K.F.4
Wright, P.C.5
-
91
-
-
11244292241
-
Validating regulatory-compliant wide dynamic range bioanalytical assays using chip-based nanoelectrospray tandem mass spectrometry
-
Wickremsinhe E.R., Ackermann B.L., Chaudhary A.K. Validating regulatory-compliant wide dynamic range bioanalytical assays using chip-based nanoelectrospray tandem mass spectrometry. Rapid Commun. Mass Spectrom. 2005, 19:47-56.
-
(2005)
Rapid Commun. Mass Spectrom.
, vol.19
, pp. 47-56
-
-
Wickremsinhe, E.R.1
Ackermann, B.L.2
Chaudhary, A.K.3
-
92
-
-
51649093301
-
Increased throughput and reduced carryover of mass spectrometry-based proteomics using a high-efficiency nonsplit nanoflow parallel dual-column capillary HPLC system
-
Wang H., Hanash S.M. Increased throughput and reduced carryover of mass spectrometry-based proteomics using a high-efficiency nonsplit nanoflow parallel dual-column capillary HPLC system. J. Proteome Res. 2008, 7:2743-2755.
-
(2008)
J. Proteome Res.
, vol.7
, pp. 2743-2755
-
-
Wang, H.1
Hanash, S.M.2
-
93
-
-
0034282498
-
A fully integrated monolithic microchip electrospray device for mass spectrometry
-
Schultz G.A., Corso T.N., Prosser S.J., Zhang S. A fully integrated monolithic microchip electrospray device for mass spectrometry. Anal. Chem. 2000, 72:4058-4063.
-
(2000)
Anal. Chem.
, vol.72
, pp. 4058-4063
-
-
Schultz, G.A.1
Corso, T.N.2
Prosser, S.J.3
Zhang, S.4
-
94
-
-
0037442314
-
Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry
-
Dethy J.M., Ackermann B.L., Delatour C., Henion J.D., Schultz G.A. Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry. Anal. Chem. 2003, 75:805-811.
-
(2003)
Anal. Chem.
, vol.75
, pp. 805-811
-
-
Dethy, J.M.1
Ackermann, B.L.2
Delatour, C.3
Henion, J.D.4
Schultz, G.A.5
|