메뉴 건너뛰기




Volumn 3, Issue 11, 2011, Pages 1271-1285

The absolute quantification of endogenous levels of brain neuropeptides in vivo using LC-MS/MS

Author keywords

[No Author keywords available]

Indexed keywords

ALPHA ENDORPHIN; ANGIOTENSIN II [3-8]; BETA ENDORPHIN; CALCITONIN GENE RELATED PEPTIDE; CALCIUM ION; DYNORPHIN A; DYNORPHIN[1-8]; GAMMA ENDORPHIN; LEUCINE ENKEPHALIN; METENKEPHALIN; NEUROKININ A; NEUROPEPTIDE; NEUROTENSIN; NEUROTENSIN[8-13]; SUBSTANCE P;

EID: 79958751966     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.11.91     Document Type: Review
Times cited : (30)

References (81)
  • 2
    • 0038714965 scopus 로고    scopus 로고
    • Neuropeptides: Opportunities for drug discovery
    • DOI 10.1016/S1474-4422(03)00482-4
    • Hökfelt T, Bartfai T, Bloom F. Neuropeptides: opportunities for drug discovery. Lancet Neurol. 2(8), 463-472 (2003). (Pubitemid 36876103)
    • (2003) Lancet Neurology , vol.2 , Issue.8 , pp. 463-472
    • Hokfelt, T.1    Bartfai, T.2    Bloom, F.3
  • 4
    • 0035282614 scopus 로고    scopus 로고
    • The roles of co-transmission in neural network modulation
    • DOI 10.1016/S0166-2236(00)01723-9, PII S0166223600017239
    • Nusbaum MP, Blitz DM, Swensen AM, Wood D, Marder E. The roles of co-transmission in neural network modulation. Trends Neurosci. 24(3), 146-154 (2001). (Pubitemid 32166819)
    • (2001) Trends in Neurosciences , vol.24 , Issue.3 , pp. 146-154
    • Nusbaum, M.P.1    Blitz, D.M.2    Swensen, A.M.3    Wood, D.4    Marder, E.5
  • 5
    • 44649093249 scopus 로고    scopus 로고
    • Listening to neuropeptides by microdialysis: Echoes and new sounds?
    • Wotjak CT, Landgraf R, Engelmann M. Listening to neuropeptides by microdialysis: echoes and new sounds? Pharmacol. Biochem. Behav. 90(2), 125-134 (2008).
    • (2008) Pharmacol. Biochem. Behav. , vol.90 , Issue.2 , pp. 125-134
    • Wotjak, C.T.1    Landgraf, R.2    Engelmann, M.3
  • 6
    • 0002911726 scopus 로고    scopus 로고
    • Neuropeptides-immunoreactivity and their mRNA expression in kindling: Functional implications for limbic epileptogenesis
    • DOI 10.1016/S0165-0173(96)00005-7
    • Schwarzer C, Sperk G, Samanin R, Rizzi M, Gariboldi M, Vezzani A. Neuropeptides- immunoreactivity and their mRNA expression in kindling: functional implications for limbic epileptogenesis. Brain Res. Rev. 22(1), 27-50 (1996). (Pubitemid 26280896)
    • (1996) Brain Research Reviews , vol.22 , Issue.1 , pp. 27-50
    • Schwarzer, C.1    Sperk, G.2    Samanin, R.3    Rizzi, M.4    Gariboldi, M.5    Vezzani, A.6
  • 7
    • 61849130512 scopus 로고    scopus 로고
    • Research priorities in epilepsy for the next decade - A representative view of the european scientific community
    • Baulac M, Pitkänen A. Research priorities in epilepsy for the next decade - a representative view of the european scientific community. Epilepsia 50(3), 571-578 (2009).
    • (2009) Epilepsia , vol.50 , Issue.3 , pp. 571-578
    • Baulac, M.1    Pitkänen, A.2
  • 8
    • 79958750098 scopus 로고    scopus 로고
    • Neuropeptides: Epilepsy
    • Squire LR (Ed.). Elsevier Amsterdam, The Netherlands
    • Mazarati A. Neuropeptides: epilepsy. In: Encyclopedia of Neuroscience. Squire LR (Ed.). Elsevier, Amsterdam, The Netherlands 6, 907-914 (2009).
    • (2009) Encyclopedia of Neuroscience , vol.6 , pp. 907-914
    • Mazarati, A.1
  • 10
    • 34848920060 scopus 로고    scopus 로고
    • Nano-LC-MS/MS for the monitoring of angiotensin IV in rat brain microdialysates: Limitations and possibilities
    • DOI 10.1002/jssc.200700159
    • Lanckmans K, Stragier B, Sarre S, Smolders I, Michotte Y. Nano-LC-MS/MS for the monitoring of angiotensin IV in rat brain microdialysates: limitations and possibilities. J. Sep. Sci. 30(14), 2217-2224 (2007). (Pubitemid 47497022)
    • (2007) Journal of Separation Science , vol.30 , Issue.14 , pp. 2217-2224
    • Lanckmans, K.1    Stragier, B.2    Sarre, S.3    Smolders, I.4    Michotte, Y.5
  • 11
    • 28844480124 scopus 로고    scopus 로고
    • Neuropeptides in CNS tissue and body fluids: Functional aspects and strategies for their identification, purification, and characterization
    • Silberring J, Ekman R (Eds) John Wiley and Sons Inc., NY, USA
    • Nyberg F. Neuropeptides in CNS tissue and body fluids: functional aspects and strategies for their identification, purification, and characterization. In: Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research. Silberring J, Ekman R (Eds). John Wiley and Sons Inc., NY, USA, 11-45 (2002).
    • (2002) Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research , pp. 11-45
    • Nyberg, F.1
  • 12
    • 10444276636 scopus 로고    scopus 로고
    • Vasopressin and oxytocin release within the brain: A dynamic concept of multiple and variable modes of neuropeptide communication
    • DOI 10.1016/j.yfrne.2004.05.001, PII S0091302204000056
    • Landgraf R, Neumann ID. Vasopressin and oxytocin release within the brain: a dynamic concept of multiple and variable modes of neuropeptide communication. Front Neuroendocrinol. 25(3-4), 150-176 (2004). (Pubitemid 39642188)
    • (2004) Frontiers in Neuroendocrinology , vol.25 , Issue.3-4 , pp. 150-176
    • Landgraf, R.1    Neumann, I.D.2
  • 13
    • 0035497747 scopus 로고    scopus 로고
    • 2 at the attomole level for monitoring and discovering endogenous peptides in microdialysis samples collected in vivo
    • DOI 10.1021/ac010774d
    • Haskins WE, Wang Z, Watson CJ et al. Capillary LC-MS2 at the attomole level for monitoring and discovering endogenous peptides in microdialysis samples collected in vivo. Anal. Chem. 73(21). 5005-5014 (2001). (Pubitemid 33032211)
    • (2001) Analytical Chemistry , vol.73 , Issue.21 , pp. 5005-5014
    • Haskins, W.E.1    Wang, Z.2    Watson, C.J.3    Rostand, R.R.4    Witowski, S.R.5    Powell, D.H.6    Kennedy, R.T.7
  • 14
    • 0032051626 scopus 로고    scopus 로고
    • Mass spectrometry of peptides in neuroscience
    • DOI 10.1016/S0196-9781(97)00471-3, PII S0196978197004713
    • Nilsson CL, Karlsson G, Bergquist J, Westman A, Ekman R. Mass spectrometry of peptides in neuroscience. Peptides 19(4), 781-789 (1998). (Pubitemid 28255017)
    • (1998) Peptides , vol.19 , Issue.4 , pp. 781-789
    • Nilsson, C.L.1    Karlsson, G.2    Bergquist, J.3    Westman, A.4    Ekman, R.5
  • 15
    • 40449106198 scopus 로고    scopus 로고
    • Application of micro- and nano-HPLC to the determination and characterization of bioactive and biomarker peptides
    • DOI 10.1002/jssc.200700589, Analysis of Peptides
    • Saz JM, Marina ML. Application of micro- and nano-HPLC to the determination and characterization of bioactive and biomarker peptides. J. Sep. Sci. 31(3), 446-458 (2008). (Pubitemid 351351177)
    • (2008) Journal of Separation Science , vol.31 , Issue.3 , pp. 446-458
    • Saz, J.M.1    Marina, M.L.2
  • 16
    • 64649099661 scopus 로고    scopus 로고
    • Practical aspects of in vivo detection of neuropeptides by microdialysis coupled off-line to capillary LC with multistage MS
    • Li Q, Zubieta JK, Kennedy RT. Practical aspects of in vivo detection of neuropeptides by microdialysis coupled off-line to capillary LC with multistage MS. Anal. Chem. 81(6), 2242-2250 (2009).
    • (2009) Anal. Chem. , vol.81 , Issue.6 , pp. 2242-2250
    • Li, Q.1    Zubieta, J.K.2    Kennedy, R.T.3
  • 17
    • 34248545256 scopus 로고    scopus 로고
    • Mass spectrometry for the quantification of bioactive peptides in biological fluids
    • DOI 10.1002/mas.20120
    • Tamvakopoulos C. Mass spectrometry for the quantification of bioactive peptides in biological fluids. Mass Spectrom. Rev. 26(3), 389-402 (2007). (Pubitemid 46750376)
    • (2007) Mass Spectrometry Reviews , vol.26 , Issue.3 , pp. 389-402
    • Tamvakopoulos, C.1
  • 18
    • 70349436833 scopus 로고    scopus 로고
    • Review of recent advances in analytical techniques for the determination of neurotransmitters
    • Perry M, Li Q, Kennedy RT. Review of recent advances in analytical techniques for the determination of neurotransmitters. Anal. Chim. Acta 653(1), 1-22 (2009).
    • (2009) Anal. Chim. Acta , vol.653 , Issue.1 , pp. 1-22
    • Perry, M.1    Li, Q.2    Kennedy, R.T.3
  • 19
    • 4544240241 scopus 로고    scopus 로고
    • Discovery and neurochemical screening of peptides in brain extracellular fluid by chemical analysis of in vivo microdialysis samples
    • DOI 10.1021/ac049363y
    • Haskins WE, Watson CJ, Cellar NA, Powell DH, Kennedy RT. Discovery and neurochemical screening of peptides in brain extracellular fluid by chemical analysis of in vivo microdialysis samples. Anal. Chem. 76(18), 5523-5533 (2004). (Pubitemid 39249440)
    • (2004) Analytical Chemistry , vol.76 , Issue.18 , pp. 5523-5533
    • Haskins, W.E.1    Watson, C.J.2    Cellar, N.A.3    Powell, D.H.4    Kennedy, R.T.5
  • 20
    • 33745686442 scopus 로고    scopus 로고
    • Identification and quantification of neuropeptides in brain tissue by capillary liquid chromatography coupled off-line to MALDI-TOF and MALDI-TOF/TOF-MS
    • Wei H, Nolkrantz K, Parkin MC, Chisolm CN, O'Callaghan JP, Kennedy RT. Identification and quantification of neuropeptides in brain tissue by capillary liquid chromatography coupled off-line to MALDI-TOF and MALDI-TOF/TOF-MS. Anal. Chem. 78(13), 4342-4351 (2006).
    • (2006) Anal. Chem. , vol.78 , Issue.13 , pp. 4342-4351
    • Wei, H.1    Nolkrantz, K.2    Parkin, M.C.3    Chisolm, C.N.4    O'Callaghan, J.P.5    Kennedy, R.T.6
  • 21
    • 79958728891 scopus 로고    scopus 로고
    • Analysis of neuropeptides in cerebrospinal fluid and neural and neuroendocrine tissues by MALDI-TOFMS
    • Silberring J, Ekman R (Eds) John Wiley and Sons Inc., NY, USA
    • Nilsson C. Analysis of neuropeptides in cerebrospinal fluid and neural and neuroendocrine tissues by MALDI-TOFMS. In: Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research. Silberring J, Ekman R (Eds). John Wiley and Sons Inc., NY, USA, 467-482 (2002).
    • (2002) Mass Spectrometry and Hyphenated Techniques in Neuropeptide Research , pp. 467-482
    • Nilsson, C.1
  • 23
    • 0034852860 scopus 로고    scopus 로고
    • In vivo microdialysis for nonapeptides in rat brain - A practical guide
    • DOI 10.1006/meth.2000.1104
    • Horn TF, Engelmann M. In vivo microdialysis for nonapeptides in rat brain - a practical guide. Methods 23(1), 41-53 (2001). (Pubitemid 32846015)
    • (2001) Methods , vol.23 , Issue.1 , pp. 41-53
    • Horn, T.F.W.1    Engelmann, M.2
  • 24
    • 69649102907 scopus 로고    scopus 로고
    • Westerinck B, Cremers T (Eds), Elsevier, Amsterdam, The Netherlands
    • Westerinck B, Cremers T. Handbook of Microdialysis. Westerinck B, Cremers T (Eds). Elsevier, Amsterdam, The Netherlands (2007).
    • (2007) Handbook of Microdialysis
    • Westerinck, B.1    Cremers, T.2
  • 25
    • 18044370880 scopus 로고    scopus 로고
    • Microdialysis - Theoretical background and recent implementation in applied life-sciences
    • DOI 10.1016/j.ejps.2005.01.017
    • Plock N, Kloft C. Microdialysis-theoretical background and recent implementation in applied life-sciences. Eur. J. Pharm. Sci. 25(1), 1-24 (2005). (Pubitemid 40602191)
    • (2005) European Journal of Pharmaceutical Sciences , vol.25 , Issue.1 , pp. 1-24
    • Plock, N.1    Kloft, C.2
  • 26
    • 0028860382 scopus 로고
    • Specific molecular mass detection of endogenously released neuropeptides using in vivo microdialysis/mass spectrometry
    • Emmett MR, Andrén PE, Caprioli RM. Specific molecular mass detection of endogenously released neuropeptides using in vivo microdialysis/mass spectrometry. J. Neurosci. Methods 62(1-2), 141-147 (1995).
    • (1995) J. Neurosci. Methods , vol.62 , Issue.1-2 , pp. 141-147
    • Emmett, M.R.1    Andrén, P.E.2    Caprioli, R.M.3
  • 27
    • 7044240014 scopus 로고    scopus 로고
    • Analytical procedures for quantification of peptides in pharmaceutical research by liquid chromatography-mass spectrometry
    • DOI 10.1007/s00216-003-2298-y
    • John H, Walden M, Schafer S, Genz S, Forssmann W. Analytical procedures for quantification of peptides in pharmaceutical research by liquid chromatography-mass spectrometry. Anal. Bioanal. Chem. 378(4), 883-897 (2004). (Pubitemid 40890201)
    • (2004) Analytical and Bioanalytical Chemistry , vol.378 , Issue.4 , pp. 883-897
    • John, H.1    Walden, M.2    Schafer, S.3    Genz, S.4    Forssmann, W.-G.5
  • 28
    • 0037487098 scopus 로고    scopus 로고
    • Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: When does ESI turn into nano-ESI?
    • DOI 10.1016/S1044-0305(03)00128-4
    • Schmidt A, Karas M, D'lcks T. Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI? J. Am. Soc. Mass Spectrom. 14(5), 492-500 (2003). (Pubitemid 36871630)
    • (2003) Journal of the American Society for Mass Spectrometry , vol.14 , Issue.5 , pp. 492-500
    • Schmidt, A.1    Karas, M.2    Dulcks, T.3
  • 29
    • 0036067603 scopus 로고    scopus 로고
    • Nanoscale LC-MS(n): Technical design and applications to peptide and protein analysis
    • Meiring H, van der Heeft E, ten Hove G, de Jong A. Nanoscale LC-MS(n): technical design and applications to peptide and protein analysis. J. Sep. Sci. 557-568 (2002).
    • (2002) J. Sep. Sci. , pp. 557-568
    • Meiring, H.1    Van Der Heeft, E.2    Ten Hove, G.3    De Jong, A.4
  • 30
    • 0001544494 scopus 로고    scopus 로고
    • Instrumental requirements for nanoscale liquid chromatography
    • Chervet J, Ursem M, Salzmann J. Instrumental requirements for nanoscale liquid chromatography. Anal. Chem. 1507-1512 (1996).
    • (1996) Anal. Chem. , pp. 1507-1512
    • Chervet, J.1    Ursem, M.2    Salzmann, J.3
  • 31
    • 0032911015 scopus 로고    scopus 로고
    • Comparison of conventional, narrow-bore and capillary liquid chromatography/mass spectrometry for electrospray ionization mass spectrometry: Practical considerations
    • DOI 10.1002/(SICI)1096-9888(19 9904)34:4<244::AID-JMS775>3.0.CO;2-0
    • Abian J, Oosterkamp A, Gelpi E. Comparison of conventional, narrow-bore and capillary liquid chromatography mass spectrometry for electrospray ionization mass spectrometry: Practical considerations. J. Mass Spectrom. 244-254 (1999). (Pubitemid 29182475)
    • (1999) Journal of Mass Spectrometry , vol.34 , Issue.4 , pp. 244-254
    • Abian, J.1    Oosterkamp, A.J.2    Gelpi, E.3
  • 32
    • 33749254404 scopus 로고    scopus 로고
    • Capillary and nano-liquid chromatography-tandem mass spectrometry for the quantification of small molecules in microdialysis samples: Comparison with microbore dimensions
    • DOI 10.1016/j.chroma.2006.07.090, PII S0021967306014269
    • Lanckmans K, Van Eeckhaut A, Sarre S, Smolders I, Michotte Y. Capillary and nano-liquid chromatography-tandem mass spectrometry for the quantification of small molecules in microdialysis samples: comparison with microbore dimensions. J. Chromatogr. A 1131(1-2), 166-175 (2006). (Pubitemid 44485675)
    • (2006) Journal of Chromatography A , vol.1131 , Issue.1-2 , pp. 166-175
    • Lanckmans, K.1    Van Eeckhaut, A.2    Sarre, S.3    Smolders, I.4    Michotte, Y.5
  • 33
    • 0034662190 scopus 로고    scopus 로고
    • Detection and quantification of neurotensin in human brain tissue by matrix-assisted laser desorption/ionization time-of- flight mass spectrometry
    • DOI 10.1021/ac991122g
    • Gobom J, Kraeuter KO, Persson R, Steen H, Roepstorff P, Ekman R. Detection and quantification of neurotensin in human brain tissue by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Anal. Chem. 72(14), 3320-3326 (2000). (Pubitemid 30482510)
    • (2000) Analytical Chemistry , vol.72 , Issue.14 , pp. 3320-3326
    • Gobom, J.1    Kraeuter, K.-O.2    Persson, R.3    Steen, H.4    Roepstorff, P.5    Ekman, R.6
  • 34
    • 0033467623 scopus 로고    scopus 로고
    • Nanoelectrospray - More than just a minimized-flow electrospray ionization source
    • DOI 10.1016/S1044-0305(98)00157-3, PII S1044030598001573
    • Juraschek R, D'lcks T, Karas M. Nanoelectrospray - more than just a minimized-flow electrospray ionization source. J. Am. Soc. Mass Spectrom. 10(4), 300-308 (1999). (Pubitemid 34467738)
    • (1999) Journal of the American Society for Mass Spectrometry , vol.10 , Issue.4 , pp. 300-308
    • Juraschek, R.1    Dulcks, T.2    Karas, M.3
  • 35
    • 50049101979 scopus 로고    scopus 로고
    • Quantitative bioanalysis of peptides by liquid chromatography coupled to (tandem) mass spectrometry
    • van den Broek I, Sparidans RW, Schellens JH, Beijnen JH. Quantitative bioanalysis of peptides by liquid chromatography coupled to (tandem) mass spectrometry. J. Chromatogr. B 872(1-2), 1-22 (2008).
    • (2008) J. Chromatogr. B , vol.872 , Issue.1-2 , pp. 1-22
    • Van Den Broek, I.1    Sparidans, R.W.2    Schellens, J.H.3    Beijnen, J.H.4
  • 36
    • 70350491152 scopus 로고    scopus 로고
    • Nanoelectrospray emitters: Trends and perspective
    • Gibson GT, Mugo SM, Oleschuk RD. Nanoelectrospray emitters: trends and perspective. Mass Spectrom. Rev. 28(6), 918-936 (2009).
    • (2009) Mass Spectrom. Rev. , vol.28 , Issue.6 , pp. 918-936
    • Gibson, G.T.1    Mugo, S.M.2    Oleschuk, R.D.3
  • 37
    • 70350575248 scopus 로고    scopus 로고
    • Fragmentation of peptides with intra-chain disulfide bonds in triple quadrupole mass spectrometry and its quantitative application to biological samples
    • Chen Y, Qiao S, Wang C. Fragmentation of peptides with intra-chain disulfide bonds in triple quadrupole mass spectrometry and its quantitative application to biological samples. Internat. J. Mass Spectrom. 288(1-3) 68-74 (2009).
    • (2009) Internat. J. Mass Spectrom. , vol.288 , Issue.1-3 , pp. 68-74
    • Chen, Y.1    Qiao, S.2    Wang, C.3
  • 38
    • 77957667141 scopus 로고    scopus 로고
    • A novel approach for quantitative peptides analysis by selected electron transfer reaction monitoring
    • Wei BY, Juang YM, Lai CC. A novel approach for quantitative peptides analysis by selected electron transfer reaction monitoring. J Chromatogr. A 1217(44), 6927-6931 (2010).
    • (2010) J Chromatogr. A , vol.1217 , Issue.44 , pp. 6927-6931
    • Wei, B.Y.1    Juang, Y.M.2    Lai, C.C.3
  • 39
    • 77955897878 scopus 로고    scopus 로고
    • Comparison between a linear ion trap and a triple quadruple MS in the sensitive detection of large peptides at femtomole amounts on column
    • Vatansever B, Lahrichi SL, Thiocone A et al. Comparison between a linear ion trap and a triple quadruple MS in the sensitive detection of large peptides at femtomole amounts on column. J. Sep. Sci. 33(16), 2478-2488 (2010).
    • (2010) J. Sep. Sci. , vol.33 , Issue.16 , pp. 2478-2488
    • Vatansever, B.1    Lahrichi, S.L.2    Thiocone, A.3
  • 40
    • 14744271199 scopus 로고    scopus 로고
    • 3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely-moving rats
    • DOI 10.1002/jms.733
    • Baseski HM, Watson CJ, Cellar NA, Shackman JG, Kennedy RT. Capillary liquid chromatography with MS3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely-moving rats. J. Mass Spectrom. 40(2), 146-153 (2005). (Pubitemid 40327254)
    • (2005) Journal of Mass Spectrometry , vol.40 , Issue.2 , pp. 146-153
    • Baseski, H.M.1    Watson, C.J.2    Cellar, N.A.3    Shackman, J.G.4    Kennedy, R.T.5
  • 41
    • 37449010910 scopus 로고    scopus 로고
    • Quantitative liquid chromatography/mass spectrometry for the analysis of microdialysates
    • Lanckmans K, Sarre S, Smolders I, Michotte Y. Quantitative liquid chromatography/mass spectrometry for the analysis of microdialysates. Talanta 74(4), 458-469 (2008).
    • (2008) Talanta , vol.74 , Issue.4 , pp. 458-469
    • Lanckmans, K.1    Sarre, S.2    Smolders, I.3    Michotte, Y.4
  • 42
    • 0023627577 scopus 로고
    • A microdialysis method allowing characterization of intercellular water space in humans
    • Lönnroth P, Jansson PA, Smith U. A microdialysis method allowing characterization of intercellular water space in humans. Am. J. Physiol. 253(2 Pt 1), 228-231 (1987).
    • (1987) Am. J. Physiol. , vol.253 , Issue.2 PART 1 , pp. 228-231
    • Lönnroth, P.1    Jansson, P.A.2    Smith, U.3
  • 43
    • 0024840234 scopus 로고
    • Microdialysis of extracellular endogenous opioid peptides from rat brain in vivo
    • Maidment NT, Brumbaugh DR, Rudolph VD, Erdelyi E, Evans CJ. Microdialysis of extracellular endogenous opioid peptides from rat brain in vivo. Neuroscience. 33(3), 549-557 (1989).
    • (1989) Neuroscience , vol.33 , Issue.3 , pp. 549-557
    • Maidment, N.T.1    Brumbaugh, D.R.2    Rudolph, V.D.3    Erdelyi, E.4    Evans, C.J.5
  • 44
    • 67649695504 scopus 로고    scopus 로고
    • In vivo peptidomics: Discovery and monitoring of neuropeptides using microdialysis and liquid chromatography with mass spectrometry
    • Westerinck B, Cremers T (Eds). Elsevier, Amsterdam, The Netherlands
    • Kennedy R. In vivo peptidomics: discovery and monitoring of neuropeptides using microdialysis and liquid chromatography with mass spectrometry. In: Handbook of microdialysis. Westerinck B, Cremers T (Eds). Elsevier, Amsterdam, The Netherlands, 279-295 (2007).
    • (2007) Handbook of Microdialysis , pp. 279-295
    • Kennedy, R.1
  • 46
    • 77049128212 scopus 로고    scopus 로고
    • A high recovery microsampling device based on a microdialysis probe for peptide sampling
    • Roy MC, Ikimura K, Nishino H, Naito T. A high recovery microsampling device based on a microdialysis probe for peptide sampling. Anal. Biochem. 399(2), 305-307 (2010).
    • (2010) Anal. Biochem. , vol.399 , Issue.2 , pp. 305-307
    • Roy, M.C.1    Ikimura, K.2    Nishino, H.3    Naito, T.4
  • 48
    • 69449093571 scopus 로고    scopus 로고
    • Current separation and detection methods in microdialysis the drive towards sensitivity and speed
    • Guihen E, O'Connor WT. Current separation and detection methods in microdialysis the drive towards sensitivity and speed. Electrophoresis. 30(12), 2062-2075 (2009).
    • (2009) Electrophoresis , vol.30 , Issue.12 , pp. 2062-2075
    • Guihen, E.1    O'Connor, W.T.2
  • 49
    • 59649101292 scopus 로고    scopus 로고
    • Separation, detection and quantitation of peptides by liquid chromatography and capillary electrochromatography
    • Issaq HJ, Chan KC, Blonder J, Ye X, Veenstra TD. Separation, detection and quantitation of peptides by liquid chromatography and capillary electrochromatography. J. Chromatogr. A. 1216(10), 1825-1837 (2009).
    • (2009) J. Chromatogr. A. , vol.1216 , Issue.10 , pp. 1825-1837
    • Issaq, H.J.1    Chan, K.C.2    Blonder, J.3    Ye, X.4    Veenstra, T.D.5
  • 50
    • 23244444793 scopus 로고    scopus 로고
    • Online microdialysis-dynamic nanoelectrospray ionization-mass spectrometry for monitoring neuropeptide secretion
    • DOI 10.1002/jms.869
    • Jakubowski JA, Hatcher NG, Sweedler JV. Online microdialysis-dynamic nanoelectrospray ionization-mass spectrometry for monitoring neuropeptide secretion. J. Mass. Spectrom. 40(7), 924-931 (2005). (Pubitemid 41098079)
    • (2005) Journal of Mass Spectrometry , vol.40 , Issue.7 , pp. 924-931
    • Jakubowski, J.A.1    Hatcher, N.G.2    Sweedler, J.V.3
  • 51
  • 52
    • 33947724473 scopus 로고    scopus 로고
    • Use of a structural analogue versus a stable isotope labeled internal standard for the quantification of angiotensin IV in rat brain dialysates using nano-liquid chromatography/tandem mass spectrometry
    • DOI 10.1002/rcm.2950
    • Lanckmans K, Sarre S, Smolders I, Michotte Y. Use of a structural analogue versus a stable isotope labeled internal standard for the quantification of angiotensin IV in rat brain dialysates using nano-liquid chromatography/tandem mass spectrometry. Rapid Commun. Mass Spectrom. 21(7), 1187-1195 (2007). (Pubitemid 46506572)
    • (2007) Rapid Communications in Mass Spectrometry , vol.21 , Issue.7 , pp. 1187-1195
    • Lanckmans, K.1    Sarre, S.2    Smolders, I.3    Michotte, Y.4
  • 53
    • 33645216681 scopus 로고    scopus 로고
    • Quantification of Gluten Exorphin A5 in cerebrospinal fluid by liquid chromatography-mass spectrometry
    • Fanciulli G, Azara E, Wood TD, Dettori A, Delitala G, Marchetti M. Quantification of Gluten Exorphin A5 in cerebrospinal fluid by liquid chromatography-mass spectrometry. J. Chromatogr. B. 833(2), 204-209 (2006).
    • (2006) J. Chromatogr. B. , vol.833 , Issue.2 , pp. 204-209
    • Fanciulli, G.1    Azara, E.2    Wood, T.D.3    Dettori, A.4    Delitala, G.5    Marchetti, M.6
  • 55
    • 33847359572 scopus 로고    scopus 로고
    • Improvement of recovery and repeatability in liquid chromatography-mass spectrometry analysis of peptides
    • DOI 10.1021/pr0604099
    • van Midwoud PM, Rieux L, Bischoff R, Verpoorte E, Niederländer HA. Improvement of recovery and repeatability in liquid chromatography-mass spectrometry analysis of peptides. J. Proteome Res. 6(2), 781-791 (2007). (Pubitemid 46340181)
    • (2007) Journal of Proteome Research , vol.6 , Issue.2 , pp. 781-791
    • Van Midwoud, P.M.1    Rieux, L.2    Bischoff, R.3    Verpoorte, E.4    Niederlander, H.A.G.5
  • 56
    • 36349018372 scopus 로고    scopus 로고
    • Differential recovery of peptides from sample tubes and the reproducibility of quantitative proteomic data
    • DOI 10.1021/pr070294o
    • Bark SJ, Hook V. Differential recovery of peptides from sample tubes and the reproducibility of quantitative proteomic data. J. Proteome Res. 6(11), 4511-4516 (2007). (Pubitemid 350158526)
    • (2007) Journal of Proteome Research , vol.6 , Issue.11 , pp. 4511-4516
    • Bark, S.J.1    Hook, V.2
  • 57
    • 0742269697 scopus 로고    scopus 로고
    • Adsorption of the decapeptide Cetrorelix depends both on the composition of dissolution medium and the type of solid surface
    • DOI 10.1016/j.ejps.2003.10.008
    • Grohganz H, Rischer M, Brandl M. Adsorption of the decapeptide Cetrorelix depends both on the composition of dissolution medium and the type of solid surface. Eur. J. Pharm. Sci. 21(2-3), 191-196 (2004). (Pubitemid 38156156)
    • (2004) European Journal of Pharmaceutical Sciences , vol.21 , Issue.2-3 , pp. 191-196
    • Grohganz, H.1    Rischer, M.2    Brandl, M.3
  • 58
    • 0029078173 scopus 로고
    • Influence of surfactants upon protein peptide adsorption to glass and polypropylene
    • Duncan M, Lee J, Warchol M. Influence of surfactants upon protein peptide adsorption to glass and polypropylene. Internat. J. Pharmaceutics. 120(2), 179-188 (1995).
    • (1995) Internat. J. Pharmaceutics. , vol.120 , Issue.2 , pp. 179-188
    • Duncan, M.1    Lee, J.2    Warchol, M.3
  • 59
    • 42649100987 scopus 로고    scopus 로고
    • Silanization of inner surfaces of nanoelectrospray ionization emitters for reduced analyte adsorption
    • DOI 10.1002/rcm.3502
    • Choi YS, Wood TD. Silanization of inner surfaces of nanoelectrospray ionization emitters for reduced analyte adsorption. Rapid Commun. Mass Spectrom. 22(8), 1265-1274 (2008). (Pubitemid 351600777)
    • (2008) Rapid Communications in Mass Spectrometry , vol.22 , Issue.8 , pp. 1265-1274
    • Yong, S.C.1    Wood, T.D.2
  • 60
    • 67650735898 scopus 로고    scopus 로고
    • Preventing carryover of peptides and proteins in nano LC-MS separations
    • Mituloví G, Stingl C, Steinmacher I et al. Preventing carryover of peptides and proteins in nano LC-MS separations. Anal. Chem. 81(14), 5955-5960 (2009).
    • (2009) Anal. Chem. , vol.81 , Issue.14 , pp. 5955-5960
    • Mituloví, G.1    Stingl, C.2    Steinmacher, I.3
  • 61
    • 38849144761 scopus 로고    scopus 로고
    • Determination of carryover and contamination for mass spectrometry-based chromatographic assays
    • DOI 10.1208/aapsj0903042, 42
    • Hughes NC, Wong EY, Fan J, Bajaj N. Determination of carryover and contamination for mass spectrometry-based chromatographic assays. AAPS J. 9(3), E353-E360 (2007). (Pubitemid 351801761)
    • (2007) AAPS Journal , vol.9 , Issue.3
    • Hughes, N.C.1    Wong, E.Y.K.2    Fan, J.3    Bajaj, N.4
  • 63
    • 30344460017 scopus 로고    scopus 로고
    • Determination of bradykinin and arg-bradykinin in rat muscle tissue by microdialysis and capillary column-switching liquid chromatography with mass spectrometric detection
    • DOI 10.1002/jssc.200500062
    • Wilson SR, Boix F, Holm A, Molander P, Lundanes E, Greibrokk T. Determination of bradykinin and arg-bradykinin in rat muscle tissue by microdialysis and capillary column-switching liquid chromatography with mass spectrometric detection. J. Sep. Sci. 28(14), 1751-1758 (2005). (Pubitemid 43055020)
    • (2005) Journal of Separation Science , vol.28 , Issue.14 , pp. 1751-1758
    • Wilson, S.R.1    Boix, F.2    Holm, A.3    Molander, P.4    Lundanes, E.5    Greibrokk, T.6
  • 64
    • 34347230956 scopus 로고    scopus 로고
    • Polyaniline-coated nanoelectrospray emitters treated with hydrophobic polymers at the tip
    • DOI 10.1002/rcm.3068
    • Choi YS, Wood TD. Polyaniline-coated nanoelectrospray emitters treated with hydrophobic polymers at the tip. Rapid Commun. Mass Spectrom. 21(13), 2101-2108 (2007). (Pubitemid 46999264)
    • (2007) Rapid Communications in Mass Spectrometry , vol.21 , Issue.13 , pp. 2101-2108
    • Yong, S.C.1    Wood, T.D.2
  • 66
    • 8644226225 scopus 로고    scopus 로고
    • Properties of an electrospray emitter coated with material of low surface energy
    • DOI 10.1016/j.chroma.2004.06.122, PII S0021967304010957
    • Tojo H. Properties of an electrospray emitter coated with material of low surface energy. J. Chromatogr. A. 1056(1-2), 223-228 (2004). (Pubitemid 39505127)
    • (2004) Journal of Chromatography A , vol.1056 , Issue.SPEC.ISS. , pp. 223-228
    • Tojo, H.1
  • 67
    • 0032232005 scopus 로고    scopus 로고
    • Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis
    • Emmett MR, White FM, Hendrickson CL, Shi SD, Marshall AG. Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysis. J Am Soc Mass Spectrom. 9(4), 333-340 (1998).
    • (1998) J Am Soc Mass Spectrom. , vol.9 , Issue.4 , pp. 333-340
    • Emmett, M.R.1    White, F.M.2    Hendrickson, C.L.3    Shi, S.D.4    Marshall, A.G.5
  • 68
    • 3042779748 scopus 로고    scopus 로고
    • Electrospray ionization with a pointed carbon fiber emitter
    • DOI 10.1021/ac030419i
    • Liu J, Ro KW, Busman M, Knapp DR. Electrospray ionization with a pointed carbon fiber emitter. Anal. Chem. 76(13), 3599-3606 (2004). (Pubitemid 38868820)
    • (2004) Analytical Chemistry , vol.76 , Issue.13 , pp. 3599-3606
    • Liu, J.1    Ro, K.W.2    Busman, M.3    Knapp, D.R.4
  • 69
    • 67349281746 scopus 로고    scopus 로고
    • Mass spectrometric quantification of MIF-1 in mouse brain by multiple reaction monitoring
    • Kheterpal I, Kastin AJ, Mollah S, Yu C, Hsuchou H, Pan W. Mass spectrometric quantification of MIF-1 in mouse brain by multiple reaction monitoring. Peptides. 30(7), 1276-1281 (2009).
    • (2009) Peptides , vol.30 , Issue.7 , pp. 1276-1281
    • Kheterpal, I.1    Kastin, A.J.2    Mollah, S.3    Yu, C.4    Hsuchou, H.5    Pan, W.6
  • 70
    • 51949090814 scopus 로고    scopus 로고
    • Quantitative measurements of cell-cell signaling peptides with single-cell MALDI MS
    • Rubakhin SS, Sweedler JV. Quantitative measurements of cell-cell signaling peptides with single-cell MALDI MS. Anal. Chem. 80(18), 7128-7136 (2008).
    • (2008) Anal. Chem. , vol.80 , Issue.18 , pp. 7128-7136
    • Rubakhin, S.S.1    Sweedler, J.V.2
  • 71
    • 70349480988 scopus 로고    scopus 로고
    • Identification, characterization and quantification of specific neuropeptides in rat spinal cord by liquid chromatography electrospray quadrupole ion trap mass spectrometry
    • Beaudry F, Ferland CE, Vachon P. Identification, characterization and quantification of specific neuropeptides in rat spinal cord by liquid chromatography electrospray quadrupole ion trap mass spectrometry. Biomed. Chromatogr. 23(9), 940-950 (2009).
    • (2009) Biomed. Chromatogr. , vol.23 , Issue.9 , pp. 940-950
    • Beaudry, F.1    Ferland, C.E.2    Vachon, P.3
  • 72
    • 28844471908 scopus 로고    scopus 로고
    • A new electrochemical HPLC method for analysis of enkephalins and endomorphins
    • DOI 10.1016/j.jneumeth.2005.06.001, PII S0165027005001949
    • Lisi TL, Sluka KA. A new electrochemical HPLC method for analysis of enkephalins and endomorphins. J. Neurosci. Methods. 150(1), 74-79 (2006). (Pubitemid 41770800)
    • (2006) Journal of Neuroscience Methods , vol.150 , Issue.1 , pp. 74-79
    • Lisi, T.L.1    Sluka, K.A.2
  • 73
    • 67649306038 scopus 로고    scopus 로고
    • Quantification of endogenous a- and g-endorphins in rat brain by liquid chromatography-tandem mass spectrometry
    • Kosanam H, Ramagiri S, Dass C. Quantification of endogenous a- and g-endorphins in rat brain by liquid chromatography-tandem mass spectrometry. Anal. Biochem. 392(1), 83-89 (2009).
    • (2009) Anal. Biochem. , vol.392 , Issue.1 , pp. 83-89
    • Kosanam, H.1    Ramagiri, S.2    Dass, C.3
  • 74
    • 0032559166 scopus 로고    scopus 로고
    • Quantitative analysis of methionine enkephalin and β-endorphin in the pituitary by liquid secondary ion mass spectrometry and tandem mass spectrometry
    • DOI 10.1016/S0021-9673(97)00670-5, PII S0021967397006705
    • Desiderio DM, Zhu X. Quantitative analysis of methionine enkephalin and b-endorphin in the pituitary by liquid secondary ion mass spectrometry and tandem mass spectrometry. J. Chromatogr. A. 794(1-2), 85-96 (1998). (Pubitemid 28083603)
    • (1998) Journal of Chromatography A , vol.794 , Issue.1-2 , pp. 85-96
    • Desiderio, D.M.1    Zhu, X.2
  • 75
    • 0031578713 scopus 로고    scopus 로고
    • Monitoring of met-enkephalin in vivo with 5-min temporal resolution using microdialysis sampling and capillary liquid chromatography with electrochemical detection
    • DOI 10.1016/S0378-4347(97)00436-2, PII S0378434797004362
    • Shen H, Lada MW, Kennedy RT. Monitoring of met-enkephalin in vivo with 5-min temporal resolution using microdialysis sampling and capillary liquid chromatography with electrochemical detection. J. Chromatogr. B. 704(1-2), 43-52 (1997). (Pubitemid 28021887)
    • (1997) Journal of Chromatography B: Biomedical Applications , vol.704 , Issue.1-2 , pp. 43-52
    • Shen, H.1    Lada, M.W.2    Kennedy, R.T.3
  • 76
    • 41549087399 scopus 로고    scopus 로고
    • Assay of bradykinin-related peptides in human body fluids using capillary electrophoresis with laser-induced fluorescence detection
    • DOI 10.1002/elps.200700594
    • Chen Y, Xu L, Lin J, Chen G. Assay of bradykinin-related peptides in human body fluids using capillary electrophoresis with laser-induced fluorescence detection. Electrophoresis 29(6), 1302-1307 (2008). (Pubitemid 351461083)
    • (2008) Electrophoresis , vol.29 , Issue.6 , pp. 1302-1307
    • Chen, Y.1    Xu, L.2    Lin, J.3    Chen, G.4
  • 77
    • 0032825145 scopus 로고    scopus 로고
    • Determination of extracellular release of neurotensin in discrete rat brain regions utilizing in vivo microdialysis/electrospray mass spectrometry
    • DOI 10.1016/S0006-8993(99)01751-5, PII S0006899399017515
    • Andrén PE, Caprioli RM. Determination of extracellular release of neurotensin in discrete rat brain regions utilizing in vivo microdialysis/ electrospray mass spectrometry. Brain Res. 845(2), 123-129 (1999). (Pubitemid 29486451)
    • (1999) Brain Research , vol.845 , Issue.2 , pp. 123-129
    • Andren, P.E.1    Caprioli, R.M.2
  • 78
    • 47749139994 scopus 로고    scopus 로고
    • Separation and determination of peptide hormones by capillary electrophoresis with laser-induced fluorescence coupled with transient pseudo-isotachophoresis preconcentration
    • Chen Y, Xu L, Zhang L, Chen G. Separation and determination of peptide hormones by capillary electrophoresis with laser-induced fluorescence coupled with transient pseudo-isotachophoresis preconcentration. Anal. Biochem. 380(2), 297-302 (2008).
    • (2008) Anal. Biochem. , vol.380 , Issue.2 , pp. 297-302
    • Chen, Y.1    Xu, L.2    Zhang, L.3    Chen, G.4
  • 79
    • 33846208636 scopus 로고    scopus 로고
    • Determination of substance P in rat spinal cord by high-performance liquid chromatography electrospray quadrupole ion trap mass spectrometry
    • DOI 10.1002/bmc.703
    • Beaudry F, Vachon P. Determination of substance P in rat spinal cord by high-performance liquid chromatography electrospray quadrupole ion trap mass spectrometry. Biomed. Chromatogr. 20(12), 1344-1350 (2006). (Pubitemid 46099742)
    • (2006) Biomedical Chromatography , vol.20 , Issue.12 , pp. 1344-1350
    • Beaudry, F.1    Vachon, P.2
  • 80
    • 0005905707 scopus 로고    scopus 로고
    • Food and Drug Administration US Department of Health and Human Services. Guidance for Industry
    • Food and Drug Administration US Department of Health and Human Services. Guidance for Industry. Bioanalytical Method Validation (2001). www.fda.gov/cder/guidance/index.htm
    • (2001) Bioanalytical Method Validation


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.