1
-
-
38849144761
-
Determination of carryover and contamination for mass spectrometry-based chromatographic assays
-
DOI 10.1208/aapsj0903042, 42
-
Hughes N, Wong E, Fan J, Bajaj N. Determination of carryover and contamination for mass spectrometry based chromatographic assay. AAPS J. 9(3), E353-E360 (2007). (Pubitemid 351801761)
-
(2007)
AAPS Journal
, vol.9
, Issue.3
-
-
Hughes, N.C.1
Wong, E.Y.K.2
Fan, J.3
Bajaj, N.4
-
2
-
-
0036144001
-
Systematic troubleshooting for LC ms/ms: Part 2 large scale LC ms/ms and automation
-
Weng N, Hall T. Systematic troubleshooting for LC MS/MS: part 2 large scale LC MS/MS and automation. Biopharm. 49, 22-26 (2002).
-
(2002)
Biopharm.
, vol.49
, pp. 22-26
-
-
Weng, N.1
Hall, T.2
-
3
-
-
79951769600
-
2009 White paper: Recent issues in regulated bioanalysis from 3rd Calibration and Validation Group Workshop
-
Savoie N, Garofolo N, van Amsterdam P et al. 2009 White paper: recent issues in regulated bioanalysis from 3rd Calibration and Validation Group Workshop. Bioanalysis 2(1), 53-68, (2010).
-
(2010)
Bioanalysis
, vol.2
, Issue.1
, pp. 53-68
-
-
Savoie, N.1
Garofolo, N.2
Van Amsterdam, P.3
-
4
-
-
11144302045
-
Elimination of autosampler carryover in a bioanalytical HPLC-MS/MS method: A case study
-
DOI 10.1016/j.jpba.2004.09.010, PII S0731708504004315
-
Vallano PT, Shugarts SB, Woolf EJ, Matuszewski BK. Elimination of autosampler carryover in a bioanalytical HPLC MS/MS method: a case study. J. Pharm. Biomed. Anal. 36, 1073-1078 (2005). (Pubitemid 40037828)
-
(2005)
Journal of Pharmaceutical and Biomedical Analysis
, vol.36
, Issue.5
, pp. 1073-1078
-
-
Vallano, P.T.1
Shugarts, S.B.2
Woolf, E.J.3
Matuszewski, B.K.4
-
5
-
-
79951737210
-
2010 White paper: Recent issues in regulated bioanalysis and global harmonization of bioanalytical guidance
-
Savoie N, Garofolo N, van Amsterdam P et al. 2010 White paper: recent issues in regulated bioanalysis and global harmonization of bioanalytical guidance. Bioanalysis 2(12), 1945-1960 (2010).
-
(2010)
Bioanalysis
, vol.2
, Issue.12
, pp. 1945-1960
-
-
Savoie, N.1
Garofolo, N.2
Van Amsterdam, P.3
-
8
-
-
79951768879
-
White paper: The 2nd Calibration and Validation Group Workshop on recent Issues in good laboratory practice in bioanalysis
-
Savoie N, Booth B, Bradley T et al. White paper: the 2nd Calibration and Validation Group Workshop on recent issues in good laboratory practice in bioanalysis. Bioanalysis 1(1), 19-30 (2009).
-
(2009)
Bioanalysis
, vol.1
, Issue.1
, pp. 19-30
-
-
Savoie, N.1
Booth, B.2
Bradley, T.3
-
9
-
-
79959421480
-
White paper: Recommendations on: Internal standard criteria, stability, incurred sample reanalysis and recent 483s by the Global CRO council for bioanalysis
-
Lowes S, Jersey J, Shoup R et al. White paper: recommendations on: internal standard criteria, stability, incurred sample reanalysis and recent 483s by the Global CRO council for bioanalysis. Bioanalysis 3(12), 1323-1332 (2011).
-
(2011)
Bioanalysis
, vol.3
, Issue.12
, pp. 1323-1332
-
-
Lowes, S.1
Jersey, J.2
Shoup, R.3
-
10
-
-
84856061416
-
Shirota.Next generation autosampler for LC MS equipped with straight injection technology
-
Salt Lake City, UT, USA 23-27 May
-
Sugito Y, Kanedo T, Shirota. Next generation autosampler for LC MS equipped with straight injection technology. Presented at: 58th American Society for Mass Spectrometry Conference. Salt Lake City, UT, USA 23-27 May 2010.
-
(2010)
Presented At: 58th American Society for Mass Spectrometry Conference
-
-
Sugito, Y.1
Kanedo, T.2
|