메뉴 건너뛰기




Volumn 4, Issue 2, 2012, Pages 133-141

An alternative solution to overcome carryover issues in bioanalysis

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ANALYTIC METHOD; ARTICLE; BIOASSAY; CONCENTRATION (PARAMETERS); FLUSHING; HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; LIMIT OF QUANTITATION; MASS SPECTROMETRY; NEEDLE; SAMPLER; SENSITIVITY AND SPECIFICITY;

EID: 84856035228     PISSN: 17576180     EISSN: 17576199     Source Type: Journal    
DOI: 10.4155/bio.11.300     Document Type: Article
Times cited : (10)

References (10)
  • 1
    • 38849144761 scopus 로고    scopus 로고
    • Determination of carryover and contamination for mass spectrometry-based chromatographic assays
    • DOI 10.1208/aapsj0903042, 42
    • Hughes N, Wong E, Fan J, Bajaj N. Determination of carryover and contamination for mass spectrometry based chromatographic assay. AAPS J. 9(3), E353-E360 (2007). (Pubitemid 351801761)
    • (2007) AAPS Journal , vol.9 , Issue.3
    • Hughes, N.C.1    Wong, E.Y.K.2    Fan, J.3    Bajaj, N.4
  • 2
    • 0036144001 scopus 로고    scopus 로고
    • Systematic troubleshooting for LC ms/ms: Part 2 large scale LC ms/ms and automation
    • Weng N, Hall T. Systematic troubleshooting for LC MS/MS: part 2 large scale LC MS/MS and automation. Biopharm. 49, 22-26 (2002).
    • (2002) Biopharm. , vol.49 , pp. 22-26
    • Weng, N.1    Hall, T.2
  • 3
    • 79951769600 scopus 로고    scopus 로고
    • 2009 White paper: Recent issues in regulated bioanalysis from 3rd Calibration and Validation Group Workshop
    • Savoie N, Garofolo N, van Amsterdam P et al. 2009 White paper: recent issues in regulated bioanalysis from 3rd Calibration and Validation Group Workshop. Bioanalysis 2(1), 53-68, (2010).
    • (2010) Bioanalysis , vol.2 , Issue.1 , pp. 53-68
    • Savoie, N.1    Garofolo, N.2    Van Amsterdam, P.3
  • 5
    • 79951737210 scopus 로고    scopus 로고
    • 2010 White paper: Recent issues in regulated bioanalysis and global harmonization of bioanalytical guidance
    • Savoie N, Garofolo N, van Amsterdam P et al. 2010 White paper: recent issues in regulated bioanalysis and global harmonization of bioanalytical guidance. Bioanalysis 2(12), 1945-1960 (2010).
    • (2010) Bioanalysis , vol.2 , Issue.12 , pp. 1945-1960
    • Savoie, N.1    Garofolo, N.2    Van Amsterdam, P.3
  • 8
    • 79951768879 scopus 로고    scopus 로고
    • White paper: The 2nd Calibration and Validation Group Workshop on recent Issues in good laboratory practice in bioanalysis
    • Savoie N, Booth B, Bradley T et al. White paper: the 2nd Calibration and Validation Group Workshop on recent issues in good laboratory practice in bioanalysis. Bioanalysis 1(1), 19-30 (2009).
    • (2009) Bioanalysis , vol.1 , Issue.1 , pp. 19-30
    • Savoie, N.1    Booth, B.2    Bradley, T.3
  • 9
    • 79959421480 scopus 로고    scopus 로고
    • White paper: Recommendations on: Internal standard criteria, stability, incurred sample reanalysis and recent 483s by the Global CRO council for bioanalysis
    • Lowes S, Jersey J, Shoup R et al. White paper: recommendations on: internal standard criteria, stability, incurred sample reanalysis and recent 483s by the Global CRO council for bioanalysis. Bioanalysis 3(12), 1323-1332 (2011).
    • (2011) Bioanalysis , vol.3 , Issue.12 , pp. 1323-1332
    • Lowes, S.1    Jersey, J.2    Shoup, R.3
  • 10
    • 84856061416 scopus 로고    scopus 로고
    • Shirota.Next generation autosampler for LC MS equipped with straight injection technology
    • Salt Lake City, UT, USA 23-27 May
    • Sugito Y, Kanedo T, Shirota. Next generation autosampler for LC MS equipped with straight injection technology. Presented at: 58th American Society for Mass Spectrometry Conference. Salt Lake City, UT, USA 23-27 May 2010.
    • (2010) Presented At: 58th American Society for Mass Spectrometry Conference
    • Sugito, Y.1    Kanedo, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.