Volumn 199, Issue , 2014, Pages 470-478

All-plastic, low-power, disposable, continuous-flow PCR chip with integrated microheaters for rapid DNA amplification

Author keywords

Continuous flow; Flexible substrates; Microfluidics; microPCR; Polyimide

Indexed keywords

DNA; ELECTRIC HEATING ELEMENTS; HEATING; MICROCHANNELS; MICROFLUIDICS; POLYIMIDES; POLYMERS; SERPENTINE; SUBSTRATES;

EID: 84899804878     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2014.04.007     Document Type: Article
Times cited : (124)

References (36)
  • 2
    • 33747117373 scopus 로고    scopus 로고
    • The origins and the future of microfluidics
    • DOI 10.1038/nature05058, PII NATURE05058
    • G.M. Whitesides The origins and the future of microfluidics Nature 442 2006 368 373 (Pubitemid 44264779)
    • (2006) Nature , vol.442 , Issue.7101 , pp. 368-373
    • Whitesides, G.M.1
  • 4
    • 57849133899 scopus 로고    scopus 로고
    • Rapid detection of genetically modified organisms on a continuous-flow polymerase chain reaction microfluidics
    • Y. Li, D. Xing, and C. Zhang Rapid detection of genetically modified organisms on a continuous-flow polymerase chain reaction microfluidics Anal. Biochem. 385 1 2009 42 49
    • (2009) Anal. Biochem. , vol.385 , Issue.1 , pp. 42-49
    • Li, Y.1    Xing, D.2    Zhang, C.3
  • 5
    • 18544374127 scopus 로고    scopus 로고
    • Real-time PCR detection of Listeria monocytogenes using an integrated microfluidics platform
    • DOI 10.1016/j.snb.2004.10.022, PII S0925400504007142
    • N. Cady, S. Stelick, M.V. Kunnavakkam, and C.A. Batt Real-time PCR detection of Listeria monocytogenes using an integrated microfluidics platform Sens. Actuators B 107 2005 332 341 (Pubitemid 40655089)
    • (2005) Sensors and Actuators, B: Chemical , vol.107 , Issue.1 , pp. 332-341
    • Cady, N.C.1    Stelick, S.2    Kunnavakkam, M.V.3    Batt, C.A.4
  • 6
    • 33645844551 scopus 로고    scopus 로고
    • PCR microfluidic devices for DNA amplification
    • C. Zhang, J. Xu, W. Ma, and W. Zheng PCR microfluidic devices for DNA amplification Biotechnol. Adv. 24 2006 243 284
    • (2006) Biotechnol. Adv. , vol.24 , pp. 243-284
    • Zhang, C.1    Xu, J.2    Ma, W.3    Zheng, W.4
  • 7
    • 1842477059 scopus 로고    scopus 로고
    • Self-Contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and dna microarray detection
    • DOI 10.1021/ac0353029
    • R.H. Liu, J. Yang, R. Lenigk, J. Bonanno, and P. Grodzinski Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection Anal. Chem. 76 2004 1824 1831 (Pubitemid 38451495)
    • (2004) Analytical Chemistry , vol.76 , Issue.7 , pp. 1824-1831
    • Liu, R.H.1    Yang, J.2    Lenigk, R.3    Bonanno, J.4    Grodzinski, P.5
  • 8
    • 0032011519 scopus 로고    scopus 로고
    • A miniature analytical instrument for nucleic acids based on micromachined silicon reaction chambers
    • M. Allen Northrup, B. Benett, D. Hadley, P. Landre, S. Lehew, J. Richards, and P. Stratton A miniature analytical instrument for nucleic acids based on micromachined silicon reaction chambers Anal. Chem. 70 1998 918 922
    • (1998) Anal. Chem. , vol.70 , pp. 918-922
    • Allen Northrup, M.1    Benett, B.2    Hadley, D.3    Landre, P.4    Lehew, S.5    Richards, J.6    Stratton, P.7
  • 9
    • 0032524099 scopus 로고    scopus 로고
    • Chemical amplification: Continuous-flow PCR on a chip
    • DOI 10.1126/science.280.5366.1046
    • M.U. Kopp, A.J. De Mello, and A. Manz Chemical amplification: continuous-flow PCR on a chip Science 280 1998 1046 1048 (Pubitemid 28234939)
    • (1998) Science , vol.280 , Issue.5366 , pp. 1046-1048
    • Kopp, M.U.1    De Mello, A.J.2    Manz, A.3
  • 10
    • 2542490465 scopus 로고    scopus 로고
    • Microfabricated flow-through device for DNA amplification - Towards in situ gene analysis
    • DOI 10.1016/j.cej.2003.11.016, PII S1385894703003231
    • T. Fukuba, T. Yamamoto, T. Naganuma, and T. Fujii Microfabricated flow-through device for DNA amplification - Towards in situ gene analysis Chem. Eng. J. 101 2004 151 156 (Pubitemid 38688757)
    • (2004) Chemical Engineering Journal , vol.101 , Issue.1-3 , pp. 151-156
    • Fukuba, T.1    Yamamoto, T.2    Naganuma, T.3    Fujii, T.4
  • 12
    • 40949136551 scopus 로고    scopus 로고
    • Continuous flow polymerase chain reaction using a hybrid PMMA-PC microchip with improved heat tolerance
    • DOI 10.1016/j.snb.2007.10.058, PII S0925400507008829
    • Y. Sun, M.V.D. Satyanarayan, N.T. Nguyen, and Y.C. Kwok Continuous flow polymerase chain reaction using a hybrid PMMA-PC microchip with improved heat tolerance Sens. Actuators B 130 2008 836 841 (Pubitemid 351417415)
    • (2008) Sensors and Actuators, B: Chemical , vol.130 , Issue.2 , pp. 836-841
    • Sun, Y.1    Satyanarayan, M.V.D.2    Nguyen, N.T.3    Kwok, Y.C.4
  • 13
    • 0035311755 scopus 로고    scopus 로고
    • Polymerase chain reaction in polymeric microchips: DNA amplification in less than 240 seconds
    • DOI 10.1006/abio.2000.4974
    • B.C. Giordano, J. Ferrance, S. Swedberg, A.F.R. Hühmer, and J.P. Landers Polymerase chain reaction in polymeric microchips: DNA amplification in less than 240 s Anal. Biochem. 291 2001 124 132 (Pubitemid 32324533)
    • (2001) Analytical Biochemistry , vol.291 , Issue.1 , pp. 124-132
    • Giordano, B.C.1    Ferrance, J.2    Swedberg, S.3    Huhmer, A.F.R.4    Landers, J.P.5
  • 14
    • 14744284141 scopus 로고    scopus 로고
    • A microchip-based PCR device using flexible printed circuit technology
    • DOI 10.1016/j.snb.2004.05.069, PII S0925400504004320
    • K. Shen, X. Chen, M. Guo, and J. Cheng A microchip-based PCR device using flexible printed circuit technology Sens. Actuators B 105 2005 251 258 (Pubitemid 40330095)
    • (2005) Sensors and Actuators, B: Chemical , vol.105 , Issue.2 , pp. 251-258
    • Shen, K.1    Chen, X.2    Guo, M.3    Cheng, J.4
  • 15
    • 0002429667 scopus 로고    scopus 로고
    • Polyimide-based microfluidic devices
    • S. Metz, R. Holzer, and P. Renaud Polyimide-based microfluidic devices Lab Chip 1 2001 29 34
    • (2001) Lab Chip , vol.1 , pp. 29-34
    • Metz, S.1    Holzer, R.2    Renaud, P.3
  • 16
    • 33745097761 scopus 로고    scopus 로고
    • Disposable real-time microPCR device: Lab-on-A-chip at a low cost
    • DOI 10.1039/b605957k
    • P. Neuzil, J. Pipper, and T.M. Hsieh Disposable real-time microPCR device: lab-on-a-chip at a low cost Mol. Biosyst. 2 2006 292 298 (Pubitemid 43882750)
    • (2006) Molecular BioSystems , vol.2 , Issue.6 , pp. 292-298
    • Neuzil, P.1    Pipper, J.2    Hsieh, T.M.3
  • 17
    • 37549023085 scopus 로고    scopus 로고
    • Polymer microfabrication technologies for microfluidic systems
    • H. Becker, and C. Gärtner Polymer microfabrication technologies for microfluidic systems Anal. Bioanal. Chem. 390 2008 89 111
    • (2008) Anal. Bioanal. Chem. , vol.390 , pp. 89-111
    • Becker, H.1    Gärtner, C.2
  • 20
    • 0037095347 scopus 로고    scopus 로고
    • A heater-integrated transparent microchannel chip for continuous-flow PCR
    • DOI 10.1016/S0925-4005(02)00016-3, PII S0925400502000163
    • K. Sun, A. Yamaguchi, Y. Ishida, S. Matsuo, and H. Misawa A heater-integrated transparent microchannel chip for continuous-flow PCR Sens. Actuators B 84 2002 283 289 (Pubitemid 34704180)
    • (2002) Sensors and Actuators, B: Chemical , vol.84 , Issue.2-3 , pp. 283-289
    • Sun, K.1    Yamaguchi, A.2    Ishida, Y.3    Matsuo, S.4    Misawa, H.5
  • 21
    • 44649158304 scopus 로고    scopus 로고
    • A disposable plastic-silicon micro PCR chip using flexible printed circuit board protocols and its application to genomic DNA amplification
    • DOI 10.1109/JSEN.2008.918923, 4529142
    • D.S. Lee, S.H. Park, K.H. Chung, and H.-B. Pyo A disposable plastic-silicon micro PCR chip using flexible printed circuit board protocols and its application to genomic DNA amplification IEEE Sens. J. 8 5 2008 558 564 (Pubitemid 351780239)
    • (2008) IEEE Sensors Journal , vol.8 , Issue.5 , pp. 558-564
    • Lee, D.-S.1    Park, S.H.2    Chung, K.H.3    Pyo, H.-B.4
  • 22
    • 10744227060 scopus 로고    scopus 로고
    • Miniaturized flow-through PCR with different template types in a silicon chip thermocycler
    • I. Schneegab, R. Brautigam, and J.M. Kohler Miniaturized flow-through PCR with different template types in a silicon chip thermocycler Lab Chip 1 2001 42 49
    • (2001) Lab Chip , vol.1 , pp. 42-49
    • Schneegab, I.1    Brautigam, R.2    Kohler, J.M.3
  • 23
    • 0027627674 scopus 로고
    • Polyimides as biomaterials: Preliminary biocompatibility testing
    • DOI 10.1016/0142-9612(93)90183-3
    • R.R. Richardson Jr., J.A. Miller, and W.M. Reichert Polyimides as biomaterials: preliminary biocompatibility testing Biomaterials 14 1993 627 635 (Pubitemid 23219810)
    • (1993) Biomaterials , vol.14 , Issue.8 , pp. 627-635
    • Richardson Jr., R.R.1    Miller, J.A.2    Reichert, W.M.3
  • 25
    • 84857158352 scopus 로고    scopus 로고
    • A continuous flow μpCR device with integrated microheaters on a flexible polyimide substrate
    • E. Mavraki, D. Moschou, G. Kokkoris, N. Vourdas, S. Chatzandroulis, and A. Tserepi A continuous flow μPCR device with integrated microheaters on a flexible polyimide substrate Procedia Eng. 25 2011 1245 1248
    • (2011) Procedia Eng. , vol.25 , pp. 1245-1248
    • Mavraki, E.1    Moschou, D.2    Kokkoris, G.3    Vourdas, N.4    Chatzandroulis, S.5    Tserepi, A.6
  • 29
    • 84899790257 scopus 로고    scopus 로고
    • www.comsol.com
  • 32
    • 65949102536 scopus 로고    scopus 로고
    • Simply and reliably integrating micro heaters/sensors in a monolithic PCR-CE microfluidic genetic analysis system
    • R. Zhong, X. Pan, L. Jiang, Z. Dai, J. Qin, and B. Lin Simply and reliably integrating micro heaters/sensors in a monolithic PCR-CE microfluidic genetic analysis system Electrophoresis 30 8 2009 1297 1305
    • (2009) Electrophoresis , vol.30 , Issue.8 , pp. 1297-1305
    • Zhong, R.1    Pan, X.2    Jiang, L.3    Dai, Z.4    Qin, J.5    Lin, B.6
  • 33
    • 33244485246 scopus 로고    scopus 로고
    • Microheater-integrated single gas sensor array chip fabricated on flexible polyimide substrate
    • DOI 10.1016/j.snb.2005.06.016, PII S0925400505005423
    • Y.S. Kim Microheater-integrated single gas sensor array chip fabricated on flexible polyimide substrate Sens. Actuators B 114 1 2006 410 417 (Pubitemid 43276206)
    • (2006) Sensors and Actuators, B: Chemical , vol.114 , Issue.1 , pp. 410-417
    • Kim, Y.S.1
  • 34
    • 84886575122 scopus 로고    scopus 로고
    • Development of a continuous-flow polymerase chain reaction device utilizing a polymer disk with a spiral microchannel of gradually varying width
    • K.H. Chung, Y.H. Choi, and S. Park Development of a continuous-flow polymerase chain reaction device utilizing a polymer disk with a spiral microchannel of gradually varying width Sens. Actuators B 191 2014 75 81
    • (2014) Sens. Actuators B , vol.191 , pp. 75-81
    • Chung, K.H.1    Choi, Y.H.2    Park, S.3
  • 36
    • 84862491918 scopus 로고    scopus 로고
    • Miniaturized nucleic acid amplification systems for rapid and point-of-care diagnostics: A review
    • F. Ahmad, and S.A. Hashsham Miniaturized nucleic acid amplification systems for rapid and point-of-care diagnostics: a review Anal. Chim. Acta 733 2012 1 15
    • (2012) Anal. Chim. Acta , vol.733 , pp. 1-15
    • Ahmad, F.1    Hashsham, S.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.