Volumn 141, Issue 1, 2009, Pages 329-337

A miniaturized quantitative polymerase chain reaction system for DNA amplification and detection

Author keywords

MEMS; Microfluidics; Microheater; Micropump; PCR; Quantification

Indexed keywords

AMPLIFICATION; BIOASSAY; COMPUTER VIRUSES; DIAGNOSIS; DNA; GENES; HEATING EQUIPMENT; MEMS; MICROELECTROMECHANICAL DEVICES; MICROFLUIDICS; MOLECULAR BIOLOGY; NUCLEIC ACIDS; POLYMERIZATION; PUMPS; SERPENTINE; SILICATE MINERALS;

EID: 84984532237     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2009.06.034     Document Type: Article
Times cited : (48)

References (36)
  • 1
    • 33645844551 scopus 로고    scopus 로고
    • PCR microfluidic devices for DNA amplification
    • Zhang C., Xu J., Ma W., and Zheng W. PCR microfluidic devices for DNA amplification. Biotechnol. Adv. 24 (2006) 243-284
    • (2006) Biotechnol. Adv. , vol.24 , pp. 243-284
    • Zhang, C.1    Xu, J.2    Ma, W.3    Zheng, W.4
  • 2
    • 34547839765 scopus 로고    scopus 로고
    • Miniaturized PCR chips for nucleic acid amplification and analysis: latest advances and future trends
    • Zhang C., and Xing D. Miniaturized PCR chips for nucleic acid amplification and analysis: latest advances and future trends. Nucl. Acids Res. 35 (2007) 4223-4237
    • (2007) Nucl. Acids Res. , vol.35 , pp. 4223-4237
    • Zhang, C.1    Xing, D.2
  • 3
    • 0031022694 scopus 로고    scopus 로고
    • Continuous fluorescence monitoring of rapid cycle DNA amplification
    • Wittwer C.T., Herrmann M.G., Moss A.A., and Rasmussen R.P. Continuous fluorescence monitoring of rapid cycle DNA amplification. Biotechniques 22 (1997) 130-138
    • (1997) Biotechniques , vol.22 , pp. 130-138
    • Wittwer, C.T.1    Herrmann, M.G.2    Moss, A.A.3    Rasmussen, R.P.4
  • 4
    • 33746745365 scopus 로고    scopus 로고
    • Absolute and relative QPCR quantification of plasmid copy number in Escherichia coli
    • Lee C., Kim J., Shin S.G., and Hwang S. Absolute and relative QPCR quantification of plasmid copy number in Escherichia coli. J. Biotechnol. 123 (2006) 273-280
    • (2006) J. Biotechnol. , vol.123 , pp. 273-280
    • Lee, C.1    Kim, J.2    Shin, S.G.3    Hwang, S.4
  • 5
    • 0036852980 scopus 로고    scopus 로고
    • Precise temperature control and rapid thermal cycling in a micromachined DNA polymerase chain reaction chip
    • Yoon D.S., Lee Y.S., Lee Y., Cho H.J., Sung S.W., Oh K.W., Cha J., and Lim G. Precise temperature control and rapid thermal cycling in a micromachined DNA polymerase chain reaction chip. J. Micromech. Microeng. 12 (2002) 813-823
    • (2002) J. Micromech. Microeng. , vol.12 , pp. 813-823
    • Yoon, D.S.1    Lee, Y.S.2    Lee, Y.3    Cho, H.J.4    Sung, S.W.5    Oh, K.W.6    Cha, J.7    Lim, G.8
  • 6
    • 1642444032 scopus 로고    scopus 로고
    • Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated microheaters and temperature sensor
    • El-Ali J., Perch-Nielsen I.R., Poulsen C.R., Bang D.D., Telleman P., and Wolff A. Simulation and experimental validation of a SU-8 based PCR thermocycler chip with integrated microheaters and temperature sensor. Sens. Actuators A: Phys. 110 (2004) 3-10
    • (2004) Sens. Actuators A: Phys. , vol.110 , pp. 3-10
    • El-Ali, J.1    Perch-Nielsen, I.R.2    Poulsen, C.R.3    Bang, D.D.4    Telleman, P.5    Wolff, A.6
  • 7
    • 10044265053 scopus 로고    scopus 로고
    • Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases
    • Liao C.S., Lee G.B., Wu J.J., Chang C.C., Hsieh T.M., Huang F.C., and Luo C.H. Micromachined polymerase chain reaction system for multiple DNA amplification of upper respiratory tract infectious diseases. Biosens. Bioelectron. 20 (2005) 1341-1348
    • (2005) Biosens. Bioelectron. , vol.20 , pp. 1341-1348
    • Liao, C.S.1    Lee, G.B.2    Wu, J.J.3    Chang, C.C.4    Hsieh, T.M.5    Huang, F.C.6    Luo, C.H.7
  • 8
    • 19944399439 scopus 로고    scopus 로고
    • Simulation and experimental study of PCR chip based on silicon
    • Yan W., Du L., Wang J., Ma L., and Zhu J. Simulation and experimental study of PCR chip based on silicon. Sens. Actuators B: Chem. 108 (2005) 695-699
    • (2005) Sens. Actuators B: Chem. , vol.108 , pp. 695-699
    • Yan, W.1    Du, L.2    Wang, J.3    Ma, L.4    Zhu, J.5
  • 10
    • 0032524099 scopus 로고    scopus 로고
    • Chemical amplification: continuous-flow PCR on a chip
    • Kopp M.U., deMello A.J., and Manz A. Chemical amplification: continuous-flow PCR on a chip. Science 280 (1998) 1046-1048
    • (1998) Science , vol.280 , pp. 1046-1048
    • Kopp, M.U.1    deMello, A.J.2    Manz, A.3
  • 11
    • 0036079139 scopus 로고    scopus 로고
    • A nanoliter rotary device for polymerase chain reaction
    • Liu J., Enzelberger M., and Quake S. A nanoliter rotary device for polymerase chain reaction. Electrophoresis 23 (2002) 1531-1536
    • (2002) Electrophoresis , vol.23 , pp. 1531-1536
    • Liu, J.1    Enzelberger, M.2    Quake, S.3
  • 13
    • 0037439263 scopus 로고    scopus 로고
    • Microfabricated device for DNA and RNA amplification by continuous-flow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection
    • Obeitn P.J., Christopoulos T.K., Crabtree H.J., and Backhouse C.J. Microfabricated device for DNA and RNA amplification by continuous-flow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection. Anal. Chem. 75 (2003) 288-295
    • (2003) Anal. Chem. , vol.75 , pp. 288-295
    • Obeitn, P.J.1    Christopoulos, T.K.2    Crabtree, H.J.3    Backhouse, C.J.4
  • 14
    • 1642524214 scopus 로고    scopus 로고
    • Microfluidic approaches to malaria detection
    • Gascoyne P., Satayavivad J., and Ruchirawat M. Microfluidic approaches to malaria detection. Acta Trop. 89 (2004) 357-369
    • (2004) Acta Trop. , vol.89 , pp. 357-369
    • Gascoyne, P.1    Satayavivad, J.2    Ruchirawat, M.3
  • 16
    • 34447299421 scopus 로고    scopus 로고
    • Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends
    • Zhang C., Xing D., and Li Y. Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends. Biotech. Adv. 25 (2007) 483-514
    • (2007) Biotech. Adv. , vol.25 , pp. 483-514
    • Zhang, C.1    Xing, D.2    Li, Y.3
  • 17
    • 34447278793 scopus 로고    scopus 로고
    • A pocket-sized convective PCR thermocycler
    • Agrawal N., Hassan Y.A., and Ugaz V.M. A pocket-sized convective PCR thermocycler. Angew. Chem. 46 (2007) 4316-4319
    • (2007) Angew. Chem. , vol.46 , pp. 4316-4319
    • Agrawal, N.1    Hassan, Y.A.2    Ugaz, V.M.3
  • 18
    • 34547133960 scopus 로고    scopus 로고
    • A circular ferrofluid driven microchip for rapid polymerase chain reaction
    • Sun Y., Kwok Y.C., and Nguyen N.T. A circular ferrofluid driven microchip for rapid polymerase chain reaction. Lap Chip 7 (2007) 1012-1017
    • (2007) Lap Chip , vol.7 , pp. 1012-1017
    • Sun, Y.1    Kwok, Y.C.2    Nguyen, N.T.3
  • 19
    • 47049088924 scopus 로고    scopus 로고
    • Clockwork PCR including sample preparation
    • Pipper J., Zhang Y., Neuzil P., and Hsieh T.M. Clockwork PCR including sample preparation. Angew. Chem. 47 (2008) 3900-3904
    • (2008) Angew. Chem. , vol.47 , pp. 3900-3904
    • Pipper, J.1    Zhang, Y.2    Neuzil, P.3    Hsieh, T.M.4
  • 20
    • 49449111633 scopus 로고    scopus 로고
    • High-throughput polymerase chain reaction in parallel circular loops using magnetic actuation
    • Sun Y., Nguyen N.T., and Kwok Y.C. High-throughput polymerase chain reaction in parallel circular loops using magnetic actuation. Anal. Chem. 80 (2008) 6127-6130
    • (2008) Anal. Chem. , vol.80 , pp. 6127-6130
    • Sun, Y.1    Nguyen, N.T.2    Kwok, Y.C.3
  • 22
    • 36849019540 scopus 로고    scopus 로고
    • Ultrasensitive PCR and real-time detection from human genomic samples using a bidirectional flow microreactor
    • Chen L., West J., Auroux P.-A., Manz A., and Day P.J.R. Ultrasensitive PCR and real-time detection from human genomic samples using a bidirectional flow microreactor. Anal. Chem. 79 (2007) 9185-9190
    • (2007) Anal. Chem. , vol.79 , pp. 9185-9190
    • Chen, L.1    West, J.2    Auroux, P.-A.3    Manz, A.4    Day, P.J.R.5
  • 25
    • 0036350239 scopus 로고    scopus 로고
    • Real-time microchip polymerase-chain-reaction system
    • Lin Y.C., Li M., Chung M.T., Wu C.Y., and Young K.C. Real-time microchip polymerase-chain-reaction system. Sens. Mater. 14 (2002) 199-208
    • (2002) Sens. Mater. , vol.14 , pp. 199-208
    • Lin, Y.C.1    Li, M.2    Chung, M.T.3    Wu, C.Y.4    Young, K.C.5
  • 28
    • 2342570922 scopus 로고    scopus 로고
    • A novel real-time PCR machine with a miniature spectrometer for fluorescence sensing in a micro liter volume glass capillary
    • Lee D.S., Wu M.H., Ramesh U., Lin C.W., Lee T.M., and Chen P.H. A novel real-time PCR machine with a miniature spectrometer for fluorescence sensing in a micro liter volume glass capillary. Sens. Actuators B: Chem. 100 (2004) 401-410
    • (2004) Sens. Actuators B: Chem. , vol.100 , pp. 401-410
    • Lee, D.S.1    Wu, M.H.2    Ramesh, U.3    Lin, C.W.4    Lee, T.M.5    Chen, P.H.6
  • 29
    • 33845742675 scopus 로고    scopus 로고
    • An integrated fluorescence detection system for lab-on-a-chip applications
    • Novak L., Neuzil P., Pipper J., Zhang Y., and Lee S. An integrated fluorescence detection system for lab-on-a-chip applications. Lap Chip 7 (2007) 27-29
    • (2007) Lap Chip , vol.7 , pp. 27-29
    • Novak, L.1    Neuzil, P.2    Pipper, J.3    Zhang, Y.4    Lee, S.5
  • 31
    • 31444437947 scopus 로고    scopus 로고
    • Pneumatically-driven peristaltic micropumps utilizing serpentine-shape channels
    • Wang C.H., and Lee G.B. Pneumatically-driven peristaltic micropumps utilizing serpentine-shape channels. J. Micromech. Microeng. 16 (2006) 341-348
    • (2006) J. Micromech. Microeng. , vol.16 , pp. 341-348
    • Wang, C.H.1    Lee, G.B.2
  • 32
    • 40949165357 scopus 로고    scopus 로고
    • Enhancement of thermal uniformity for a microthermal cycler and its application for polymerase chain reaction
    • Hsieh T.M., Luo C.H., Huang F.C., Wang J.H., Chien L.J., and Lee G.B. Enhancement of thermal uniformity for a microthermal cycler and its application for polymerase chain reaction. Sens. Actuators B: Chem. 130 (2008) 848-856
    • (2008) Sens. Actuators B: Chem. , vol.130 , pp. 848-856
    • Hsieh, T.M.1    Luo, C.H.2    Huang, F.C.3    Wang, J.H.4    Chien, L.J.5    Lee, G.B.6
  • 34
    • 17344392308 scopus 로고    scopus 로고
    • A new mathematical model for relative quantification in real-time RT-PCR
    • Pfaffl M.W. A new mathematical model for relative quantification in real-time RT-PCR. Nucl. Acids Res. 29 (2001) 45-50
    • (2001) Nucl. Acids Res. , vol.29 , pp. 45-50
    • Pfaffl, M.W.1
  • 35
    • 0242322735 scopus 로고    scopus 로고
    • Cylindrical compact thermal-cycling device for continuous-flow polymerase chain reaction
    • Park N., Kim S., and Hahn J.H. Cylindrical compact thermal-cycling device for continuous-flow polymerase chain reaction. Anal. Chem. 75 (2003) 6029-6033
    • (2003) Anal. Chem. , vol.75 , pp. 6029-6033
    • Park, N.1    Kim, S.2    Hahn, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.