메뉴 건너뛰기




Volumn 38, Issue 3, 2014, Pages 503-508

A comparison of conventional and patient-specific instruments in total knee arthroplasty

Author keywords

Component malalignment; Hip knee ankle angle; Neutral mechanical axis; Patient matched cutting blocks; Standard knee instrumentation; Total knee arthroplasty; Total knee replacement

Indexed keywords

ADULT; AGED; ARTICLE; FEMALE; HUMAN; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; PEROPERATIVE COMPLICATION; PERSONALIZED MEDICINE; PRIORITY JOURNAL; SURGICAL ANATOMY; TOTAL KNEE REPLACEMENT; VERY ELDERLY; X RAY; ANKLE; BONE MALALIGNMENT; CASE CONTROL STUDY; COHORT ANALYSIS; COMPUTER ASSISTED TOMOGRAPHY; DEVICES; HIP; INCIDENCE; KNEE; KNEE ARTHROPLASTY; KNEE PROSTHESIS; PROCEDURES; PROSTHESIS; RADIOGRAPHY; RETROSPECTIVE STUDY; SURGERY; TREATMENT OUTCOME;

EID: 84898842627     PISSN: 03412695     EISSN: 14325195     Source Type: Journal    
DOI: 10.1007/s00264-013-2028-9     Document Type: Article
Times cited : (65)

References (45)
  • 1
    • 84861188144 scopus 로고    scopus 로고
    • Custom-fit total knee arthroplasty: Our initial experience in 32 knees
    • 22285230 10.1016/j.arth.2011.12.006
    • Bali K, Walker P, Bruce W (2012) Custom-fit total knee arthroplasty: our initial experience in 32 knees. J Arthroplasty 27:1149-1154
    • (2012) J Arthroplasty , vol.27 , pp. 1149-1154
    • Bali, K.1    Walker, P.2    Bruce, W.3
  • 2
    • 84870234400 scopus 로고    scopus 로고
    • Patient specific cutting blocks are currently of no proven value
    • 1:STN:280:DC%2BC3s7hs1ejtw%3D%3D 23118393 10.1302/0301-620X.94B11.30834
    • Barrack RL, Ruh EL, Williams BM, Ford AD, Foreman K, Nunley RM (2012) Patient specific cutting blocks are currently of no proven value. J Bone Joint Surg Br 94(11 Suppl A):95-99
    • (2012) J Bone Joint Surg Br , vol.94 , Issue.11 SUPPL.. A , pp. 95-99
    • Barrack, R.L.1    Ruh, E.L.2    Williams, B.M.3    Ford, A.D.4    Foreman, K.5    Nunley, R.M.6
  • 3
    • 4043104035 scopus 로고    scopus 로고
    • Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique
    • 1:STN:280:DC%2BD2czntFGhtA%3D%3D 15274263 10.1302/0301-620X.86B5.14927
    • Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J (2004) Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86:682-687
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 682-687
    • Bathis, H.1    Perlick, L.2    Tingart, M.3    Luring, C.4    Zurakowski, D.5    Grifka, J.6
  • 4
    • 79956308778 scopus 로고    scopus 로고
    • Evaluating comorbidities in total hip and knee arthroplasty: Available instruments
    • 3014469 21076850 10.1007/s10195-010-0115-x
    • Bjorgul K, Novicoff WM, Saleh KJ (2010) Evaluating comorbidities in total hip and knee arthroplasty: available instruments. J Orthop Traumatol 11:203-209
    • (2010) J Orthop Traumatol , vol.11 , pp. 203-209
    • Bjorgul, K.1    Novicoff, W.M.2    Saleh, K.J.3
  • 5
    • 84865313117 scopus 로고    scopus 로고
    • Preliminary experience with the patient-specific templating total knee arthroplasty
    • 3427630 22880715 10.3109/17453674.2012.711700
    • Boonen B, Schotanus MG, Kort NP (2012) Preliminary experience with the patient-specific templating total knee arthroplasty. Acta Orthop 83:387-393
    • (2012) Acta Orthop , vol.83 , pp. 387-393
    • Boonen, B.1    Schotanus, M.G.2    Kort, N.P.3
  • 6
    • 84874668905 scopus 로고    scopus 로고
    • A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement
    • 1:STN:280:DC%2BC3svitlWktQ%3D%3D 23450020 10.1302/0301-620X.95B3.29903
    • Chareancholvanich K, Narkbunnam R, Pornrattanamaneewong C (2013) A prospective randomised controlled study of patient-specific cutting guides compared with conventional instrumentation in total knee replacement. Bone Joint J 95-B:354-359
    • (2013) Bone Joint J , vol.95 , pp. 354-359
    • Chareancholvanich, K.1    Narkbunnam, R.2    Pornrattanamaneewong, C.3
  • 7
    • 2342432329 scopus 로고    scopus 로고
    • Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial
    • 1:STN:280:DC%2BD2c3is1amsw%3D%3D 15125124 10.1302/0301-620X.86B3.14643
    • Chauhan SK, Scott RG, Breidahl W, Beaver RJ (2004) Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial. J Bone Joint Surg Br 86:372-377
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 372-377
    • Chauhan, S.K.1    Scott, R.G.2    Breidahl, W.3    Beaver, R.J.4
  • 8
    • 84861707581 scopus 로고    scopus 로고
    • Little clinical advantage of computer-assisted navigation over conventional instrumentation in primary total knee arthroplasty at early follow-up
    • 1:CAS:528:DC%2BC38XhtVSmsr3E 22130355 10.1016/j.knee.2011.10.001
    • Cheng T, Pan XY, Mao X, Zhang GY, Zhang XL (2012) Little clinical advantage of computer-assisted navigation over conventional instrumentation in primary total knee arthroplasty at early follow-up. Knee 19:237-245
    • (2012) Knee , vol.19 , pp. 237-245
    • Cheng, T.1    Pan, X.Y.2    Mao, X.3    Zhang, G.Y.4    Zhang, X.L.5
  • 9
    • 23044438302 scopus 로고    scopus 로고
    • Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique
    • 16309998 10.1016/j.arth.2005.04.004
    • Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20:618-626
    • (2005) J Arthroplasty , vol.20 , pp. 618-626
    • Chin, P.L.1    Yang, K.Y.2    Yeo, S.J.3    Lo, N.N.4
  • 10
    • 34250223372 scopus 로고    scopus 로고
    • Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty
    • 17545435 10.2106/JBJS.F.00667
    • Collier MB, Engh CA Jr, McAuley JP, Engh GA (2007) Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty. J Bone Joint Surg Am 89:1306-1314
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 1306-1314
    • Collier, M.B.1    Engh, Jr.C.A.2    McAuley, J.P.3    Engh, G.A.4
  • 11
    • 84866712897 scopus 로고    scopus 로고
    • Are MRI-based, patient matched cutting jigs as accurate as the tibial guides?
    • 3535040 22426932 10.1007/s00264-012-1522-9
    • Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A (2012) Are MRI-based, patient matched cutting jigs as accurate as the tibial guides? Int Orthop 36:1589-1593
    • (2012) Int Orthop , vol.36 , pp. 1589-1593
    • Conteduca, F.1    Iorio, R.2    Mazza, D.3    Caperna, L.4    Bolle, G.5    Argento, G.6    Ferretti, A.7
  • 12
    • 84871928682 scopus 로고    scopus 로고
    • Frontal plane alignment after total knee arthroplasty using patient-specific instruments
    • 3532632 23232654 10.1007/s00264-012-1732-1
    • Daniilidis K, Tibesku CO (2013) Frontal plane alignment after total knee arthroplasty using patient-specific instruments. Int Orthop 37:45-50
    • (2013) Int Orthop , vol.37 , pp. 45-50
    • Daniilidis, K.1    Tibesku, C.O.2
  • 13
    • 16244411067 scopus 로고    scopus 로고
    • Leg axis after computer-navigated total knee arthroplasty: A prospective randomized trial comparing computer-navigated and manual implantation
    • 15809943 10.1016/j.arth.2004.09.047
    • Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP (2005) Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20:282-288
    • (2005) J Arthroplasty , vol.20 , pp. 282-288
    • Decking, R.1    Markmann, Y.2    Fuchs, J.3    Puhl, W.4    Scharf, H.P.5
  • 15
    • 16844363744 scopus 로고    scopus 로고
    • Computer-assisted navigation increases precision of component placement in total knee arthroplasty
    • 15805951 10.1097/01.blo.0000150564.31880.c4
    • Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A (2005) Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res 433:152-159
    • (2005) Clin Orthop Relat Res , vol.433 , pp. 152-159
    • Haaker, R.G.1    Stockheim, M.2    Kamp, M.3    Proff, G.4    Breitenfelder, J.5    Ottersbach, A.6
  • 16
    • 33646007057 scopus 로고    scopus 로고
    • Computer-assisted total knee arthroplasty using patient-specific templating
    • 1:STN:280:DC%2BD287ms1CmsA%3D%3D 16446589 10.1097/01.blo.0000201148. 06454.ef
    • Hafez MA, Chelule KL, Seedhom BB, Sherman KP (2006) Computer-assisted total knee arthroplasty using patient-specific templating. Clin Orthop Relat Res 444:184-192
    • (2006) Clin Orthop Relat Res , vol.444 , pp. 184-192
    • Hafez, M.A.1    Chelule, K.L.2    Seedhom, B.B.3    Sherman, K.P.4
  • 17
    • 0346099499 scopus 로고    scopus 로고
    • Total knee arthroplasty implanted with and without kinematic navigation
    • 1:STN:280:DC%2BD3srptFyhtg%3D%3D 3461874 12942197 10.1007/s00264-003- 0501-6
    • Hart R, Janecek M, Chaker A, Bucek P (2003) Total knee arthroplasty implanted with and without kinematic navigation. Int Orthop 27:366-369
    • (2003) Int Orthop , vol.27 , pp. 366-369
    • Hart, R.1    Janecek, M.2    Chaker, A.3    Bucek, P.4
  • 18
    • 84892485168 scopus 로고    scopus 로고
    • Improved femoral component rotation in TKA using patient-specific instrumentation
    • 10.1016/j.knee.2012.10.009
    • Heyse TJ, Tibesku CO (2012) Improved femoral component rotation in TKA using patient-specific instrumentation. Knee. doi: 10.1016/j.knee.2012.10.009
    • (2012) Knee
    • Heyse, T.J.1    Tibesku, C.O.2
  • 19
    • 58149354595 scopus 로고    scopus 로고
    • Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients
    • 18814593 10.3928/01477447-20080901-15
    • Howell SM, Kuznik K, Hull ML, Siston RA (2008) Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients. Orthopedics 31:857-863
    • (2008) Orthopedics , vol.31 , pp. 857-863
    • Howell, S.M.1    Kuznik, K.2    Hull, M.L.3    Siston, R.A.4
  • 20
    • 0025856476 scopus 로고
    • Coronal alignment after total knee replacement
    • 1:STN:280:DyaK3MzntlCjug%3D%3D 1894655
    • Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73:709-714
    • (1991) J Bone Joint Surg Br , vol.73 , pp. 709-714
    • Jeffery, R.S.1    Morris, R.W.2    Denham, R.A.3
  • 21
    • 39849084917 scopus 로고    scopus 로고
    • Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres
    • 18262789 10.1016/j.knee.2007.12.004
    • Jenny JY, Miehlke RK, Giurea A (2008) Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres. Knee 15:80-84
    • (2008) Knee , vol.15 , pp. 80-84
    • Jenny, J.Y.1    Miehlke, R.K.2    Giurea, A.3
  • 22
    • 84861808002 scopus 로고    scopus 로고
    • The benefits of customized patient instrumentation to lower-volume joint replacement surgeons: Results from practice
    • Johnson DR (2011) The benefits of customized patient instrumentation to lower-volume joint replacement surgeons: results from practice. Am J Orthop (Belle Mead NJ) 40(11 Suppl):13-16
    • (2011) Am J Orthop (Belle Mead NJ) , vol.40 , Issue.11 SUPPL.. , pp. 13-16
    • Johnson, D.R.1
  • 23
    • 34249791470 scopus 로고    scopus 로고
    • Alignment and orientation of the components in total knee replacement with and without navigation support: A prospective, randomised study
    • 17463114 10.1302/0301-620X.89B4.18878
    • Kim YH, Kim JS, Yoon SH (2007) Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br 89:471-476
    • (2007) J Bone Joint Surg Br , vol.89 , pp. 471-476
    • Kim, Y.H.1    Kim, J.S.2    Yoon, S.H.3
  • 24
    • 37349078592 scopus 로고    scopus 로고
    • Custom-fit total knee arthroplasty (OtisKnee) results in malalignment
    • 18165024 10.1016/j.arth.2007.10.001
    • Klatt BA, Goyal N, Austin MS, Hozack WJ (2008) Custom-fit total knee arthroplasty (OtisKnee) results in malalignment. J Arthroplasty 23:26-29
    • (2008) J Arthroplasty , vol.23 , pp. 26-29
    • Klatt, B.A.1    Goyal, N.2    Austin, M.S.3    Hozack, W.J.4
  • 25
    • 80052087247 scopus 로고    scopus 로고
    • Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplasty
    • 20688521 10.1016/j.knee.2010.06.008
    • Koeck FX, Beckmann J, Luring C, Rath B, Grifka J, Basad E (2011) Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplasty. Knee 18:294-299
    • (2011) Knee , vol.18 , pp. 294-299
    • Koeck, F.X.1    Beckmann, J.2    Luring, C.3    Rath, B.4    Grifka, J.5    Basad, E.6
  • 26
    • 84874562813 scopus 로고    scopus 로고
    • Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty
    • 23151366 10.1016/j.arth.2012.07.012
    • Lustig S, Scholes CJ, Oussedik SI, Kinzel V, Coolican MR, Parker DA (2013) Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. J Arthroplasty 28:469-473
    • (2013) J Arthroplasty , vol.28 , pp. 469-473
    • Lustig, S.1    Scholes, C.J.2    Oussedik, S.I.3    Kinzel, V.4    Coolican, M.R.5    Parker, D.A.6
  • 28
    • 33846839286 scopus 로고    scopus 로고
    • A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation
    • 17272435 10.2106/JBJS.F.00386
    • Matziolis G, Krocker D, Weiss U, Tohtz S, Perka C (2007) A prospective, randomized study of computer-assisted and conventional total knee arthroplasty. Three-dimensional evaluation of implant alignment and rotation. J Bone Joint Surg Am 89:236-243
    • (2007) J Bone Joint Surg Am , vol.89 , pp. 236-243
    • Matziolis, G.1    Krocker, D.2    Weiss, U.3    Tohtz, S.4    Perka, C.5
  • 29
    • 84878234059 scopus 로고    scopus 로고
    • Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty
    • 10.1016/j.knee.2012.12.009
    • Nam D, Maher PA, Rebolledo BJ, Nawabi DH, McLawhorn AS, Pearle AD (2013) Patient specific cutting guides versus an imageless, computer-assisted surgery system in total knee arthroplasty. Knee. doi: 10.1016/j.knee.2012.12.009
    • (2013) Knee
    • Nam, D.1    Maher, P.A.2    Rebolledo, B.J.3    Nawabi, D.H.4    McLawhorn, A.S.5    Pearle, A.D.6
  • 30
    • 84865102501 scopus 로고    scopus 로고
    • Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA
    • 3237987 21809150 10.1007/s11999-011-1996-6
    • Ng VY, DeClaire JH, Berend KR, Gulick BC, Lombardi AV Jr (2012) Improved accuracy of alignment with patient-specific positioning guides compared with manual instrumentation in TKA. Clin Orthop Relat Res 470:99-107
    • (2012) Clin Orthop Relat Res , vol.470 , pp. 99-107
    • Ng, V.Y.1    Declaire, J.H.2    Berend, K.R.3    Gulick, B.C.4    Lombardi, Jr.A.V.5
  • 31
    • 83555176169 scopus 로고    scopus 로고
    • The value of patient-matched instrumentation in total knee arthroplasty
    • 21908169 10.1016/j.arth.2011.07.006
    • Noble JW Jr, Moore CA, Liu N (2012) The value of patient-matched instrumentation in total knee arthroplasty. J Arthroplasty 27:153-155
    • (2012) J Arthroplasty , vol.27 , pp. 153-155
    • Noble, Jr.J.W.1    Moore, C.A.2    Liu, N.3
  • 32
    • 84856958576 scopus 로고    scopus 로고
    • Do patient-specific guides improve coronal alignment in total knee arthroplasty?
    • 3270188 22183477 10.1007/s11999-011-2222-2
    • Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470:895-902
    • (2012) Clin Orthop Relat Res , vol.470 , pp. 895-902
    • Nunley, R.M.1    Ellison, B.S.2    Zhu, J.3    Ruh, E.L.4    Howell, S.M.5    Barrack, R.L.6
  • 33
    • 0028044658 scopus 로고
    • Postoperative alignment of total knee replacement. Its effect on survival
    • 8119010
    • Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop Relat Res 299:153-156
    • (1994) Clin Orthop Relat Res , vol.299 , pp. 153-156
    • Ritter, M.A.1    Faris, P.M.2    Keating, E.M.3    Meding, J.B.4
  • 34
    • 58649104415 scopus 로고    scopus 로고
    • The statistical relationship between varus deformity, surgeon's experience, BMI and tourniquet time for computer assisted total knee replacements
    • 19013071 10.1016/j.knee.2008.09.008
    • Sampath SA, Voon SH, Sangster M, Davies H (2009) The statistical relationship between varus deformity, surgeon's experience, BMI and tourniquet time for computer assisted total knee replacements. Knee 16:121-124
    • (2009) Knee , vol.16 , pp. 121-124
    • Sampath, S.A.1    Voon, S.H.2    Sangster, M.3    Davies, H.4
  • 36
    • 53649099385 scopus 로고    scopus 로고
    • Alignment in total knee replacement
    • 1:STN:280:DC%2BD1crntFOlsA%3D%3D 18757949 10.1302/0301-620X.90B9.20793
    • Sikorski JM (2008) Alignment in total knee replacement. J Bone Joint Surg Br 90:1121-1127
    • (2008) J Bone Joint Surg Br , vol.90 , pp. 1121-1127
    • Sikorski, J.M.1
  • 37
    • 0043030086 scopus 로고    scopus 로고
    • Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study
    • 1:STN:280:DC%2BD3szpsVGjtg%3D%3D 12931800
    • Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85:830-835
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 830-835
    • Sparmann, M.1    Wolke, B.2    Czupalla, H.3    Banzer, D.4    Zink, A.5
  • 38
    • 72349096775 scopus 로고    scopus 로고
    • Initial experience with custom-fit total knee replacement: Intra-operative events and long-leg coronal alignment
    • 2899191 19099305 10.1007/s00264-008-0693-x
    • Spencer BA, Mont MA, McGrath MS, Boyd B, Mitrick MF (2009) Initial experience with custom-fit total knee replacement: intra-operative events and long-leg coronal alignment. Int Orthop 33:1571-1575
    • (2009) Int Orthop , vol.33 , pp. 1571-1575
    • Spencer, B.A.1    Mont, M.A.2    McGrath, M.S.3    Boyd, B.4    Mitrick, M.F.5
  • 39
    • 84865371365 scopus 로고    scopus 로고
    • Effect of tibial component varus on wear in total knee arthroplasty
    • 22206820 10.1016/j.knee.2011.11.003
    • Srivastava A, Lee GY, Steklov N, Colwell CW Jr, Ezzet KA, D'Lima DD (2012) Effect of tibial component varus on wear in total knee arthroplasty. Knee 19:560-563
    • (2012) Knee , vol.19 , pp. 560-563
    • Srivastava, A.1    Lee, G.Y.2    Steklov, N.3    Colwell, Jr.C.W.4    Ezzet, K.A.5    D'Lima, D.D.6
  • 40
    • 4444334669 scopus 로고    scopus 로고
    • Navigation improves accuracy of rotational alignment in total knee arthroplasty
    • 15346071 10.1097/01.blo.0000136835.40566.d9
    • Stockl B, Nogler M, Rosiek R, Fischer M, Krismer M, Kessler O (2004) Navigation improves accuracy of rotational alignment in total knee arthroplasty. Clin Orthop Relat Res 426:180-186
    • (2004) Clin Orthop Relat Res , vol.426 , pp. 180-186
    • Stockl, B.1    Nogler, M.2    Rosiek, R.3    Fischer, M.4    Krismer, M.5    Kessler, O.6
  • 41
    • 0036394724 scopus 로고    scopus 로고
    • Computer-assisted navigation in total knee replacement: Results of an initial experience in thirty-five patients
    • 12479344
    • Stulberg SD, Loan P, Sarin V (2002) Computer-assisted navigation in total knee replacement: results of an initial experience in thirty-five patients. J Bone Joint Surg Am 84-A(Suppl 2):90-98
    • (2002) J Bone Joint Surg Am , vol.84 , Issue.SUPPL. 2 , pp. 90-98
    • Stulberg, S.D.1    Loan, P.2    Sarin, V.3
  • 42
    • 0023933597 scopus 로고
    • A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty
    • 3365891
    • Tillett ED, Engh GA, Petersen T (1988) A comparative study of extramedullary and intramedullary alignment systems in total knee arthroplasty. Clin Orthop Relat Res 230:176-181
    • (1988) Clin Orthop Relat Res , vol.230 , pp. 176-181
    • Tillett, E.D.1    Engh, G.A.2    Petersen, T.3
  • 43
    • 10444234298 scopus 로고    scopus 로고
    • The effect of valgus/varus malalignment on load distribution in total knee replacements
    • 15598463 10.1016/j.jbiomech.2004.02.024
    • Werner FW, Ayers DC, Maletsky LP, Rullkoetter PJ (2005) The effect of valgus/varus malalignment on load distribution in total knee replacements. J Biomech 38:349-355
    • (2005) J Biomech , vol.38 , pp. 349-355
    • Werner, F.W.1    Ayers, D.C.2    Maletsky, L.P.3    Rullkoetter, P.J.4
  • 44
    • 84867798395 scopus 로고    scopus 로고
    • Component sizing in total knee arthroplasty: Patient-specific guides vs. Cmputer-assisted navigation
    • 10.1515/bmt-2011-0093
    • Yaffe MA, Patel A, Mc Coy BW, Luo M, Cayo M, Ghate R, Stulberg SD (2012) Component sizing in total knee arthroplasty: patient-specific guides vs. computer-assisted navigation. Biomed Tech (Berl) 57:277-282
    • (2012) Biomed Tech (Berl) , vol.57 , pp. 277-282
    • Yaffe, M.A.1    Patel, A.2    Mc Coy, B.W.3    Luo, M.4    Cayo, M.5    Ghate, R.6    Stulberg, S.D.7
  • 45
    • 43349106247 scopus 로고    scopus 로고
    • Computer navigation did not improve alignment in a lower-volume total knee practice
    • 1:STN:280:DC%2BD1c7nsFSgtw%3D%3D 2504660 18259827 10.1007/s11999-008- 0144-4
    • Yau WP, Chiu KY, Zuo JL, Tang WM, Ng TP (2008) Computer navigation did not improve alignment in a lower-volume total knee practice. Clin Orthop Relat Res 466:935-945
    • (2008) Clin Orthop Relat Res , vol.466 , pp. 935-945
    • Yau, W.P.1    Chiu, K.Y.2    Zuo, J.L.3    Tang, W.M.4    Ng, T.P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.