메뉴 건너뛰기




Volumn 84, Issue SUPPL. 2, 2002, Pages 90-98

Computer-assisted navigation in total knee replacement: Results of an initial experience in thirty-five patients

Author keywords

[No Author keywords available]

Indexed keywords

BONE SCREW; CLINICAL ARTICLE; COMPUTER ASSISTED SURGERY; CONFERENCE PAPER; HUMAN; INSTRUMENTATION; JOINT FUNCTION; KINEMATICS; PRIORITY JOURNAL; SURGICAL APPROACH; SURGICAL TECHNIQUE; TIBIA; TOTAL KNEE REPLACEMENT; TREATMENT OUTCOME;

EID: 0036394724     PISSN: 00219355     EISSN: None     Source Type: Journal    
DOI: 10.2106/00004623-200200002-00011     Document Type: Conference Paper
Times cited : (323)

References (36)
  • 1
    • 0022537079 scopus 로고    scopus 로고
    • Technical considerations in total knee arthroplasty
    • Dorr LD, Boiardo RA. Technical considerations in total knee arthroplasty. Clin Orthop. 1997;205:5-11.
    • (1997) Clin Orthop , vol.205 , pp. 5-11
    • Dorr, L.D.1    Boiardo, R.A.2
  • 2
    • 0023029715 scopus 로고
    • The influence of tibial-patellofemoral location on function of the knee in patients with posterior stabilized condylar knee prosthesis
    • Figgie HE 3rd, Goldberg VM, Heiple KG, Moller HS 3rd, Gordon NH. The influence of tibial-patellofemoral location on function of the knee in patients with posterior stabilized condylar knee prosthesis. J Bone Joint Surg Am. 1986;68:1035-40.
    • (1986) J Bone Joint Surg Am , vol.68 , pp. 1035-1040
    • Figgie H.E. III1    Goldberg, V.M.2    Heiple, K.G.3    Moller H.S. III4    Gordon, N.H.5
  • 4
    • 0022529498 scopus 로고
    • Clinical results of the Oxford knee. Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis
    • Goodfellow JW, O'Connor J. Clinical results of the Oxford knee. Surface arthroplasty of the tibiofemoral joint with a meniscal bearing prosthesis. Clin Orthop. 1986;205:21-42.
    • (1986) Clin Orthop , vol.205 , pp. 21-42
    • Goodfellow, J.W.1    O'Connor, J.2
  • 7
    • 0018346367 scopus 로고
    • The total condylar prosthesis. A report of two hundred and twenty cases
    • Insall J, Scott WN, Ranawat CS. The total condylar prosthesis. A report of two hundred and twenty cases. J Bone Joint Surg Am. 1979;61:173-80.
    • (1979) J Bone Joint Surg Am , vol.61 , pp. 173-180
    • Insall, J.1    Scott, W.N.2    Ranawat, C.S.3
  • 8
    • 0023868757 scopus 로고
    • Survivorship analysis and results of total condylar knee arthroplasty. Eight- to 11-year follow-up period
    • Ranawat CS, Boachie-Adjei O. Survivorship analysis and results of total condylar knee arthroplasty. Eight- to 11-year follow-up period. Clin Orthop. 1988;226:6-13.
    • (1988) Clin Orthop , vol.226 , pp. 6-13
    • Ranawat, C.S.1    Boachie-Adjei, O.2
  • 9
    • 0028839546 scopus 로고
    • Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty
    • Teter KE, Bregman D, Colwell CW Jr. Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty. Clin Orthop. 1995;321:106-10.
    • (1995) Clin Orthop , vol.321 , pp. 106-110
    • Teter, K.E.1    Bregman, D.2    Colwell C.W., Jr.3
  • 10
    • 0023098711 scopus 로고
    • Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines
    • Ecker ML, Lotke PA, Windsor RE, Cella JP. Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. Clin Orthop. 1987;216:151-8.
    • (1987) Clin Orthop , vol.216 , pp. 151-158
    • Ecker, M.L.1    Lotke, P.A.2    Windsor, R.E.3    Cella, J.P.4
  • 11
    • 0027954306 scopus 로고
    • Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces
    • Feng EL, Stulberg SD, Wixson RL. Progressive subluxation and polyethylene wear in total knee replacements with flat articular surfaces. Clin Orthop. 1994;229:60-71.
    • (1994) Clin Orthop , vol.229 , pp. 60-71
    • Feng, E.L.1    Stulberg, S.D.2    Wixson, R.L.3
  • 12
    • 0025239766 scopus 로고
    • Prediction of total knee motion using a three-dimensional computer-graphics model
    • Garg A, Walker PS. Prediction of total knee motion using a three-dimensional computer-graphics model. J Biomech. 1990;23:45-58.
    • (1990) J Biomech , vol.23 , pp. 45-58
    • Garg, A.1    Walker, P.S.2
  • 14
    • 0025342934 scopus 로고
    • Total condylar knee replacement in patients who have rheumatoid arthritis. A ten-year follow-up study
    • Laskin RS. Total condylar knee replacement in patients who have rheumatoid arthritis. A ten-year follow-up study. J Bone Joint Surg Am. 1990;72:529-35.
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 529-535
    • Laskin, R.S.1
  • 15
    • 0027170064 scopus 로고
    • Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty
    • Oswald MH, Jakob RP, Schneider E, Hoogewoud H. Radiological analysis of normal axial alignment of femur and tibia in view of total knee arthroplasty. J Arthroplasty. 1993;8:419-26.
    • (1993) J Arthroplasty , vol.8 , pp. 419-426
    • Oswald, M.H.1    Jakob, R.P.2    Schneider, E.3    Hoogewoud, H.4
  • 16
    • 0032029572 scopus 로고    scopus 로고
    • Posterior tilting of the tibial component decreases femoral rollback in posterior-substituting knee replacement: A computer simulation study
    • Piazza SJ, Delp SL, Stulberg SD, Stern SH. Posterior tilting of the tibial component decreases femoral rollback in posterior-substituting knee replacement: a computer simulation study. J Orthop Res. 1998;16:264-70.
    • (1998) J Orthop Res , vol.16 , pp. 264-270
    • Piazza, S.J.1    Delp, S.L.2    Stulberg, S.D.3    Stern, S.H.4
  • 17
    • 0028044658 scopus 로고
    • Postoperative alignment of total knee replacement. Its effect on survival
    • Ritter MA, Faris PM, Keating EM, Meding JB. Postoperative alignment of total knee replacement. Its effect on survival. Clin Orthop. 1994;299:153-6.
    • (1994) Clin Orthop , vol.299 , pp. 153-156
    • Ritter, M.A.1    Faris, P.M.2    Keating, E.M.3    Meding, J.B.4
  • 18
    • 0028344841 scopus 로고
    • Radiolucency at the bonecement interface in total knee replacement. The effects of bone-surfacing preparation and cement technique
    • Ritter MA, Herbst SA, Keating EM, Faris PM. Radiolucency at the bonecement interface in total knee replacement. The effects of bone-surfacing preparation and cement technique. J Bone Joint Surg Am. 1994;76:60-5.
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 60-65
    • Ritter, M.A.1    Herbst, S.A.2    Keating, E.M.3    Faris, P.M.4
  • 19
    • 0026803119 scopus 로고
    • Posterior stabilized prosthesis. Results after follow-up of nine to twelve years
    • Stern SH, Insall JN. Posterior stabilized prosthesis. Results after follow-up of nine to twelve years. J Bone Joint Surg Am. 1992;74:980-6.
    • (1992) J Bone Joint Surg Am , vol.74 , pp. 980-986
    • Stern, S.H.1    Insall, J.N.2
  • 20
    • 0027972449 scopus 로고
    • Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty
    • Wasielewski RC, Galante JO, Leighty R, Natarajan RN, Rosenberg AG. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop. 1994; 299:31-43.
    • (1994) Clin Orthop , vol.299 , pp. 31-43
    • Wasielewski, R.C.1    Galante, J.O.2    Leighty, R.3    Natarajan, R.N.4    Rosenberg, A.G.5
  • 24
    • 0000550744 scopus 로고    scopus 로고
    • A computer-assisted total knee replacement surgical system using a calibrated robot
    • Taylor RH, Lavallee S, Burdea GC, Mosges R, editors. Cambridge, MA: The MIT Press
    • Kienzle TC, Stulberg SD, Peshkin M, et al. A computer-assisted total knee replacement surgical system using a calibrated robot. In: Taylor RH, Lavallee S, Burdea GC, Mosges R, editors. Computer-integrated surgery: technology and clinical applications. Cambridge, MA: The MIT Press; 1996. p 409-16.
    • (1996) Computer-integrated surgery: technology and clinical applications , pp. 409-416
    • Kienzle, T.C.1    Stulberg, S.D.2    Peshkin, M.3
  • 26
    • 0027428016 scopus 로고
    • Robotic assistance in orthopaedic surgery. A proof of principle using distal femoral arthroplasty
    • Matsen FA 3rd, Garbini JL, Sidles JA, Pratt B, Baumgarten D, Kalura R. Robotic assistance in orthopaedic surgery. A proof of principle using distal femoral arthroplasty. Clin Orthop. 1993;296:178-86.
    • (1993) Clin Orthop , vol.296 , pp. 178-186
    • Matsen F.A. III1    Garbini, J.L.2    Sidles, J.A.3    Pratt, B.4    Baumgarten, D.5    Kalura, R.6
  • 28
    • 0010797058 scopus 로고    scopus 로고
    • Early clinical results with the Orthopilot System
    • Picard F, Leitner F, Raoult O, et al. Early clinical results with the Orthopilot System [abstract]. Comput Aided Surg. 1999.
    • (1999) Comput Aided Surg
    • Picard, F.1    Leitner, F.2    Raoult, O.3
  • 29
    • 0002009157 scopus 로고    scopus 로고
    • Computer-assisted total knee replacement arthroplasty
    • Stulberg SD, Picard F, Saragaglia D. Computer-assisted total knee replacement arthroplasty. Op Tech Orthop. 2000;10:25-39.
    • (2000) Op Tech Orthop , vol.10 , pp. 25-39
    • Stulberg, S.D.1    Picard, F.2    Saragaglia, D.3
  • 33
    • 0010799370 scopus 로고    scopus 로고
    • Computer navigated implantation of total knee prostheses - A radiological study
    • Böhler M, Messner M, Glos W, Riegler M. Computer navigated implantation of total knee prostheses-a radiological study. Acta Chir Austriaca. 2001; 33(Suppl 175):63.
    • (2001) Acta Chir Austriaca , vol.33 , Issue.SUPPL. 175 , pp. 63
    • Böhler, M.1    Messner, M.2    Glos, W.3    Riegler, M.4
  • 34
    • 0035024525 scopus 로고    scopus 로고
    • Navigated implantation of total knee endoprostheses - A comparison with conventional instrumentation
    • German
    • Jenny JY, Boeri C. [Navigated implantation of total knee endoprostheses-a comparison with conventional instrumentation]. Z Orthop Ihre Grenzgeb. 2001;139:117-9. German
    • (2001) Z Orthop Ihre Grenzgeb , vol.139 , pp. 117-119
    • Jenny, J.Y.1    Boeri, C.2
  • 35
    • 0035022484 scopus 로고    scopus 로고
    • Navigation in knee endopros Thesis implantation-preliminary clinical experiences and prospective comparative study with conventional implantation technique
    • German
    • Mielke RK, Clemens U, Jens JH, Kershally S. [Navigation in knee endopros thesis implantation-preliminary clinical experiences and prospective comparative study with conventional implantation technique]. Z Orthop Ihre Grenzgeb. 2001;139:109-16. German.
    • (2001) Z Orthop Ihre Grenzgeb , vol.139 , pp. 109-116
    • Mielke, R.K.1    Clemens, U.2    Jens, J.H.3    Kershally, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.