computer navigation; custom guides; knee; total knee arthroplasty
Indexed keywords
ADULT;
AGED;
ARTICLE;
CASE REPORT;
CONTROLLED STUDY;
FEMALE;
FEMUR;
HUMAN;
MALE;
NUCLEAR MAGNETIC RESONANCE IMAGING;
PREOPERATIVE PERIOD;
RANGE OF MOTION;
TIBIA;
TOTAL KNEE REPLACEMENT;
VALGUS DEFORMITY;
The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot
Green G.V. The effects of varus tibial alignment on proximal tibial surface strain in total knee arthroplasty: the posteromedial hot spot. J Arthroplasty 17 (2002) 8
Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique
Bathis H. Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br 86 (2004) 5
Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation
Decking R. Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty 20 (2005) 3
Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses
Jenny J.Y. Consistency of implantation of a total knee arthroplasty with a non-image-based navigation system: a case-control study of 235 cases compared with 235 conventionally implanted prostheses. J Arthroplasty 20 (2005) 7
Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study
Sparmann M. Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85 (2003) 6
The effect of tibial polyethylene insert design on range of motion: evaluation of in vivo knee kinematics by a computerized navigation system during total knee arthroplasty
Klein G.R. The effect of tibial polyethylene insert design on range of motion: evaluation of in vivo knee kinematics by a computerized navigation system during total knee arthroplasty. J Arthroplasty 19 (2004) 8
The effect of knee component design changes on range of motion evaluation in vivo by a computerized navigation system
Klein G.R. The effect of knee component design changes on range of motion evaluation in vivo by a computerized navigation system. J Arthroplasty 21 (2006) 5
The effectiveness of sequential medial soft tissue release on coronal alignment in total knee arthroplasty: using a computer navigation model
Luring C. The effectiveness of sequential medial soft tissue release on coronal alignment in total knee arthroplasty: using a computer navigation model. J Arthroplasty 21 (2006) 3
Clinical experience using a minimally invasive surgical approach for total knee arthroplasty: early results of a prospective randomized study compared to a standard approach
Kolisek F.R. Clinical experience using a minimally invasive surgical approach for total knee arthroplasty: early results of a prospective randomized study compared to a standard approach. J Arthroplasty 22 (2007) 1