메뉴 건너뛰기




Volumn 17, Issue 2, 2014, Pages 69-91

Three-dimensional cephalometric analysis in orthodontics: A systematic review

Author keywords

Cephalometry; Cone beam computed tomography; Orthodontics; Spiral computed tomography; Three dimensional imaging

Indexed keywords

ANATOMIC LANDMARK; CEPHALOMETRY; CONE BEAM COMPUTED TOMOGRAPHY; HUMAN; ORTHODONTICS; PROCEDURES; RADIOGRAPHY; REPRODUCIBILITY; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; STATISTICS AND NUMERICAL DATA; THREE DIMENSIONAL IMAGING;

EID: 84897965835     PISSN: 16016335     EISSN: 16016343     Source Type: Journal    
DOI: 10.1111/ocr.12034     Document Type: Review
Times cited : (77)

References (62)
  • 1
    • 0004604603 scopus 로고
    • Bedeutung der Röntgenfern und Abstands Aufnahme für die Diagnostik der Kieferanomalien
    • Hofrath H. Bedeutung der Röntgenfern und Abstands Aufnahme für die Diagnostik der Kieferanomalien. Fortschr Orthod 1931;1:231-58.
    • (1931) Fortschr Orthod , vol.1 , pp. 231-258
    • Hofrath, H.1
  • 2
    • 0002784542 scopus 로고
    • A new x-ray technique and its application to orthodontia
    • Broadbent BH. A new x-ray technique and its application to orthodontia. Angle Orthodontists 1931;1:45-66.
    • (1931) Angle Orthodontists , vol.1 , pp. 45-66
    • Broadbent, B.H.1
  • 3
    • 0015156256 scopus 로고
    • The reliability of head film measurements. 2. Conventional angular and linear measures
    • Baumrind S, Frantz RC. The reliability of head film measurements. 2. Conventional angular and linear measures. Am J Orthod 1971;60:505-17.
    • (1971) Am J Orthod , vol.60 , pp. 505-517
    • Baumrind, S.1    Frantz, R.C.2
  • 4
    • 0015105142 scopus 로고
    • The reliability of head film measurements. 1. Landmark identification
    • Baumrind S, Frantz RC. The reliability of head film measurements. 1. Landmark identification. Am J Orthod 1971;60:111-27.
    • (1971) Am J Orthod , vol.60 , pp. 111-127
    • Baumrind, S.1    Frantz, R.C.2
  • 5
    • 0346286924 scopus 로고
    • Measurement on radiographs
    • Bjork A, Solow B. Measurement on radiographs. J Dent Res 1962;41:672-83.
    • (1962) J Dent Res , vol.41 , pp. 672-683
    • Bjork, A.1    Solow, B.2
  • 6
    • 34547670613 scopus 로고    scopus 로고
    • Precision and accuracy of low-dose CT protocols in the evaluation of skull landmarks
    • Connor SE, Arscott T, Berry J, Greene L, O'Gorman R. Precision and accuracy of low-dose CT protocols in the evaluation of skull landmarks. Dentomaxillofac Radiol 2007;36:270-6.
    • (2007) Dentomaxillofac Radiol , vol.36 , pp. 270-276
    • Connor, S.E.1    Arscott, T.2    Berry, J.3    Greene, L.4    O'Gorman, R.5
  • 7
    • 48649096171 scopus 로고    scopus 로고
    • Accuracy of three-dimensional (3D) craniofacial cephalometric landmarks on a low-dose 3D computed tomograph
    • Olszewski R, Reychler H, Cosnard G, Denis JM, Vynckier S, Zech F. Accuracy of three-dimensional (3D) craniofacial cephalometric landmarks on a low-dose 3D computed tomograph. Dentomaxillofac Radiol 2008;37:261-7.
    • (2008) Dentomaxillofac Radiol , vol.37 , pp. 261-267
    • Olszewski, R.1    Reychler, H.2    Cosnard, G.3    Denis, J.M.4    Vynckier, S.5    Zech, F.6
  • 8
    • 84871939031 scopus 로고    scopus 로고
    • Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography
    • Olszewski R, Frison L, Wisniewski M, Denis JM, Vynckier S, Cosnard G et al. Reproducibility of three-dimensional cephalometric landmarks in cone-beam and low-dose computed tomography. Clin Oral Investig 2013;17:285-92.
    • (2013) Clin Oral Investig , vol.17 , pp. 285-292
    • Olszewski, R.1    Frison, L.2    Wisniewski, M.3    Denis, J.M.4    Vynckier, S.5    Cosnard, G.6
  • 9
    • 34547666996 scopus 로고    scopus 로고
    • Comparison of conventional and cone-beam CT synthesized cephalograms
    • Kumar V, Ludlow JB, Mol A, Cevidanes L. Comparison of conventional and cone-beam CT synthesized cephalograms. Dentomaxillofac Radiol 2007;36:263-9.
    • (2007) Dentomaxillofac Radiol , vol.36 , pp. 263-269
    • Kumar, V.1    Ludlow, J.B.2    Mol, A.3    Cevidanes, L.4
  • 10
    • 34848918149 scopus 로고    scopus 로고
    • Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography
    • Moshiri M, Scarfe WC, Hilgers ML, Scheetz JP, Silveira AM, Farman AG. Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography. Am J Orthod Dentofacial Orthop 2007;132:550-60.
    • (2007) Am J Orthod Dentofacial Orthop , vol.132 , pp. 550-560
    • Moshiri, M.1    Scarfe, W.C.2    Hilgers, M.L.3    Scheetz, J.P.4    Silveira, A.M.5    Farman, A.G.6
  • 13
    • 50949089055 scopus 로고    scopus 로고
    • In vivo comparison of conventional and cone beam CT synthesized cephalograms
    • Kumar V, Ludlow J, Soares Cevidanes LH, Mol A. In vivo comparison of conventional and cone beam CT synthesized cephalograms. Angle Orthod 2008;78:873-9.
    • (2008) Angle Orthod , vol.78 , pp. 873-879
    • Kumar, V.1    Ludlow, J.2    Soares Cevidanes, L.H.3    Mol, A.4
  • 16
    • 77952689207 scopus 로고    scopus 로고
    • 3D cephalometrics: the new norm
    • Chenin DL. 3D cephalometrics: the new norm. Alpha Omegan 2010;103:51-6.
    • (2010) Alpha Omegan , vol.103 , pp. 51-56
    • Chenin, D.L.1
  • 17
    • 33748268672 scopus 로고    scopus 로고
    • A new method of 3-D cephalometry Part I: the anatomic Cartesian 3-D reference system
    • Swennen GR, Schutyser F, Barth EL, De Groeve P, De Mey A. A new method of 3-D cephalometry Part I: the anatomic Cartesian 3-D reference system. J Craniofac Surg 2006;17:314-25.
    • (2006) J Craniofac Surg , vol.17 , pp. 314-325
    • Swennen, G.R.1    Schutyser, F.2    Barth, E.L.3    De Groeve, P.4    De Mey, A.5
  • 18
  • 19
    • 33644877729 scopus 로고    scopus 로고
    • Three-dimensional cone beam computerized tomography in orthodontics
    • Kau CH, Richmond S, Palomo JM, Hans MG. Three-dimensional cone beam computerized tomography in orthodontics. J Orthod 2005;32:282-93.
    • (2005) J Orthod , vol.32 , pp. 282-293
    • Kau, C.H.1    Richmond, S.2    Palomo, J.M.3    Hans, M.G.4
  • 21
    • 84897958012 scopus 로고    scopus 로고
    • editors. Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy. Version 1.0: The Cochrane Collaboration;. Available from:
    • Deeks JJ, Bossuyt PM, Gatsonis C, editors. Cochrane Handbook for Systematic Reviews of Diagnostic Test Accuracy. Version 1.0: The Cochrane Collaboration; 2010. Available from: http://srdta.cochrane.org/handbook-dta-reviews.
    • (2010)
    • Deeks, J.J.1    Bossuyt, P.M.2    Gatsonis, C.3
  • 22
    • 85100415918 scopus 로고    scopus 로고
    • editors. Cochrane Handbook for Systematic Reviews of Interventions. Version 5.1.0 [updated March 2011]: The Cochrane Collaboration;. Available from:
    • Higgins JPT, Green S, editors. Cochrane Handbook for Systematic Reviews of Interventions. Version 5.1.0 [updated March 2011]: The Cochrane Collaboration; 2011. Available from: http://www.cochrane-handbook.org/.
    • (2011)
    • Higgins, J.P.T.1    Green, S.2
  • 23
    • 0028012745 scopus 로고
    • Users' guides to the medical literature. III. How to use an article about a diagnostic test. A. Are the results of the study valid? Evidence-Based Medicine Working Group
    • Jaeschke R, Guyatt G, Sackett DL. Users' guides to the medical literature. III. How to use an article about a diagnostic test. A. Are the results of the study valid? Evidence-Based Medicine Working Group. JAMA 1994;271:389-91.
    • (1994) JAMA , vol.271 , pp. 389-391
    • Jaeschke, R.1    Guyatt, G.2    Sackett, D.L.3
  • 24
    • 0028760247 scopus 로고
    • Users' guides to the medical literature. III. How to use an article about a diagnostic test. B. What are the results and will they help me in caring for my patients? The Evidence-Based Medicine Working Group
    • Jaeschke R, Guyatt GH, Sackett DL. Users' guides to the medical literature. III. How to use an article about a diagnostic test. B. What are the results and will they help me in caring for my patients? The Evidence-Based Medicine Working Group. JAMA 1994;271:703-7.
    • (1994) JAMA , vol.271 , pp. 703-707
    • Jaeschke, R.1    Guyatt, G.H.2    Sackett, D.L.3
  • 25
    • 2942700307 scopus 로고    scopus 로고
    • The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews
    • Whiting P, Rutjes AW, Reitsma JB, Bossuyt PM, Kleijnen J. The development of QUADAS: a tool for the quality assessment of studies of diagnostic accuracy included in systematic reviews. BMC Med Res Methodol 2003;3:25.
    • (2003) BMC Med Res Methodol , vol.3 , pp. 25
    • Whiting, P.1    Rutjes, A.W.2    Reitsma, J.B.3    Bossuyt, P.M.4    Kleijnen, J.5
  • 26
    • 68549101842 scopus 로고    scopus 로고
    • The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration
    • Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gotzsche PC, Ioannidis JP et al. The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate healthcare interventions: explanation and elaboration. BMJ 2009;339:b2700.
    • (2009) BMJ , vol.339
    • Liberati, A.1    Altman, D.G.2    Tetzlaff, J.3    Mulrow, C.4    Gotzsche, P.C.5    Ioannidis, J.P.6
  • 28
    • 7944229474 scopus 로고    scopus 로고
    • Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications
    • Cavalcanti MG, Rocha SS, Vannier MW. Craniofacial measurements based on 3D-CT volume rendering: implications for clinical applications. Dentomaxillofac Radiol 2004;33:170-6.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 170-176
    • Cavalcanti, M.G.1    Rocha, S.S.2    Vannier, M.W.3
  • 29
    • 67649628169 scopus 로고    scopus 로고
    • Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo
    • Chien PC, Parks ET, Eraso F, Hartsfield JK, Roberts WE, Ofner S. Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo. Dentomaxillofac Radiol 2009;38:262-73.
    • (2009) Dentomaxillofac Radiol , vol.38 , pp. 262-273
    • Chien, P.C.1    Parks, E.T.2    Eraso, F.3    Hartsfield, J.K.4    Roberts, W.E.5    Ofner, S.6
  • 30
    • 84855968543 scopus 로고    scopus 로고
    • A three-dimensional comparison of a morphometric and conventional cephalometric midsagittal planes for craniofacial asymmetry
    • Damstra J, Fourie Z, De Wit M, Ren Y. A three-dimensional comparison of a morphometric and conventional cephalometric midsagittal planes for craniofacial asymmetry. Clin Oral Investig 2012;16:285-94.
    • (2012) Clin Oral Investig , vol.16 , pp. 285-294
    • Damstra, J.1    Fourie, Z.2    De Wit, M.3    Ren, Y.4
  • 31
    • 80052359768 scopus 로고    scopus 로고
    • Reliability and the smallest detectable difference of measurements on 3-dimensional cone-beam computed tomography images
    • Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y. Reliability and the smallest detectable difference of measurements on 3-dimensional cone-beam computed tomography images. Am J Orthod Dentofacial Orthop 2011;140:e107-14.
    • (2011) Am J Orthod Dentofacial Orthop , vol.140
    • Damstra, J.1    Fourie, Z.2    Huddleston Slater, J.J.3    Ren, Y.4
  • 32
    • 79959310027 scopus 로고    scopus 로고
    • Comparison between two-dimensional and midsagittal three-dimensional cephalometric measurements of dry human skulls
    • Damstra J, Fourie Z, Ren Y. Comparison between two-dimensional and midsagittal three-dimensional cephalometric measurements of dry human skulls. Br J Oral Maxillofac Surg 2011;49:392-5.
    • (2011) Br J Oral Maxillofac Surg , vol.49 , pp. 392-395
    • Damstra, J.1    Fourie, Z.2    Ren, Y.3
  • 34
    • 78649707135 scopus 로고    scopus 로고
    • Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans
    • Gribel BF, Gribel MN, Frazao DC, McNamara JA Jr, Manzi FR. Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans. Angle Orthod 2011;81:26-35.
    • (2011) Angle Orthod , vol.81 , pp. 26-35
    • Gribel, B.F.1    Gribel, M.N.2    Frazao, D.C.3    McNamara Jr, J.A.4    Manzi, F.R.5
  • 35
    • 78649716732 scopus 로고    scopus 로고
    • From 2D to 3D: an algorithm to derive normal values for 3-dimensional computerized assessment
    • Gribel BF, Gribel MN, Manzi FR, Brooks SL, McNamara JA Jr. From 2D to 3D: an algorithm to derive normal values for 3-dimensional computerized assessment. Angle Orthod 2011;81:3-10.
    • (2011) Angle Orthod , vol.81 , pp. 3-10
    • Gribel, B.F.1    Gribel, M.N.2    Manzi, F.R.3    Brooks, S.L.4    McNamara Jr, J.A.5
  • 36
    • 84875123611 scopus 로고    scopus 로고
    • Precision of identifying cephalometric landmarks with cone beam computed tomography in vivo
    • Hassan B, Nijkamp P, Verheij H, Tairie J, Vink C, Stelt PV et al. Precision of identifying cephalometric landmarks with cone beam computed tomography in vivo. Eur J Orthod 2013;35:38-44.
    • (2013) Eur J Orthod , vol.35 , pp. 38-44
    • Hassan, B.1    Nijkamp, P.2    Verheij, H.3    Tairie, J.4    Vink, C.5    Stelt, P.V.6
  • 38
    • 68349083593 scopus 로고    scopus 로고
    • Reliability of traditional cephalometric landmarks as seen in three-dimensional analysis in maxillary expansion treatments
    • Lagravère MO, Gordon JM, Guedes IH, Flores-Mir C, Carey JP, Heo G et al. Reliability of traditional cephalometric landmarks as seen in three-dimensional analysis in maxillary expansion treatments. Angle Orthod 2009;79:1047-56.
    • (2009) Angle Orthod , vol.79 , pp. 1047-1056
    • Lagravère, M.O.1    Gordon, J.M.2    Guedes, I.H.3    Flores-Mir, C.4    Carey, J.P.5    Heo, G.6
  • 39
    • 77954670876 scopus 로고    scopus 로고
    • Intraexaminer and interexaminer reliabilities of landmark identification on digitized lateral cephalograms and formatted 3-dimensional cone-beam computerized tomography images
    • Lagravère MO, Low C, Flores-Mir C, Chung R, Carey JP, Heo G et al. Intraexaminer and interexaminer reliabilities of landmark identification on digitized lateral cephalograms and formatted 3-dimensional cone-beam computerized tomography images. Am J Orthod Dentofacial Orthop 2010;137:598-604.
    • (2010) Am J Orthod Dentofacial Orthop , vol.137 , pp. 598-604
    • Lagravère, M.O.1    Low, C.2    Flores-Mir, C.3    Chung, R.4    Carey, J.P.5    Heo, G.6
  • 41
    • 69249228690 scopus 로고    scopus 로고
    • Precision of cephalometric landmark identification: cone-beam computed tomography vs conventional cephalometric views
    • discussion 12-3.
    • Ludlow JB, Gubler M, Cevidanes L, Mol A. Precision of cephalometric landmark identification: cone-beam computed tomography vs conventional cephalometric views. Am J Orthod Dentofacial Orthop 2009;136: 312 e1-10; discussion 12-3.
    • (2009) Am J Orthod Dentofacial Orthop , vol.136 , Issue.312
    • Ludlow, J.B.1    Gubler, M.2    Cevidanes, L.3    Mol, A.4
  • 42
    • 84864024385 scopus 로고    scopus 로고
    • Application of cone beam volumetric tomography in endodontics
    • Tyndall DA, Kohltfarber H. Application of cone beam volumetric tomography in endodontics. Austral Dent J 2012;57(Suppl 1):72-81.
    • (2012) Austral Dent J , vol.57 , Issue.SUPPL 1 , pp. 72-81
    • Tyndall, D.A.1    Kohltfarber, H.2
  • 43
    • 34249112582 scopus 로고    scopus 로고
    • Cone beam computed tomographic findings in refractory chronic suppurative osteomyelitis of the mandible
    • Fullmer JM, Scarfe WC, Kushner GM, Alpert B, Farman AG. Cone beam computed tomographic findings in refractory chronic suppurative osteomyelitis of the mandible. Br J Oral Maxillofac Surg 2007;45:364-71.
    • (2007) Br J Oral Maxillofac Surg , vol.45 , pp. 364-371
    • Fullmer, J.M.1    Scarfe, W.C.2    Kushner, G.M.3    Alpert, B.4    Farman, A.G.5
  • 44
    • 77649185880 scopus 로고    scopus 로고
    • Reproducibility of osseous landmarks used for computed tomography based three-dimensional cephalometric analyses
    • Olszewski R, Tanesy O, Cosnard G, Zech F, Reychler H. Reproducibility of osseous landmarks used for computed tomography based three-dimensional cephalometric analyses. J Craniomaxillofac Surg 2010;38:214-21.
    • (2010) J Craniomaxillofac Surg , vol.38 , pp. 214-221
    • Olszewski, R.1    Tanesy, O.2    Cosnard, G.3    Zech, F.4    Reychler, H.5
  • 45
    • 34548501279 scopus 로고    scopus 로고
    • Three-dimensional computed tomography cephalometric craniofacial analysis: experimental validation in vitro
    • Olszewski R, Zech F, Cosnard G, Nicolas V, Macq B, Reychler H. Three-dimensional computed tomography cephalometric craniofacial analysis: experimental validation in vitro. Int J Oral Maxillofac Surg 2007;36:828-33.
    • (2007) Int J Oral Maxillofac Surg , vol.36 , pp. 828-833
    • Olszewski, R.1    Zech, F.2    Cosnard, G.3    Nicolas, V.4    Macq, B.5    Reychler, H.6
  • 46
    • 33646185460 scopus 로고    scopus 로고
    • A proposal for a new analysis of craniofacial morphology by 3-dimensional computed tomography
    • Park SH, Yu HS, Kim KD, Lee KJ, Baik HS. A proposal for a new analysis of craniofacial morphology by 3-dimensional computed tomography. Am J Orthod Dentofacial Orthop 2006;129(600):e23-34.
    • (2006) Am J Orthod Dentofacial Orthop , vol.129 , Issue.600
    • Park, S.H.1    Yu, H.S.2    Kim, K.D.3    Lee, K.J.4    Baik, H.S.5
  • 47
    • 43449117523 scopus 로고    scopus 로고
    • Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program
    • Periago DR, Scarfe WC, Moshiri M, Scheetz JP, Silveira AM, Farman AG. Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program. Angle Orthod 2008;78:387-95.
    • (2008) Angle Orthod , vol.78 , pp. 387-395
    • Periago, D.R.1    Scarfe, W.C.2    Moshiri, M.3    Scheetz, J.P.4    Silveira, A.M.5    Farman, A.G.6
  • 48
    • 0029000970 scopus 로고
    • Precision, repeatability, and validation of the localization of cranial landmarks using computed tomography scans
    • Richtsmeier JT, Paik CH, Elfert PC, Cole TM 3rd, Dahlman HR. Precision, repeatability, and validation of the localization of cranial landmarks using computed tomography scans. Cleft Palate Craniofac J 1995;32:217-27.
    • (1995) Cleft Palate Craniofac J , vol.32 , pp. 217-227
    • Richtsmeier, J.T.1    Paik, C.H.2    Elfert, P.C.3    Cole III, T.M.4    Dahlman, H.R.5
  • 49
    • 84866480248 scopus 로고    scopus 로고
    • Reproducibility of three-dimensional coordinate systems based on craniofacial landmarks
    • Shibata M, Nawa H, Kise Y, Fuyamada M, Yoshida K, Katsumata A et al. Reproducibility of three-dimensional coordinate systems based on craniofacial landmarks. Angle Orthod 2012;82:776-84.
    • (2012) Angle Orthod , vol.82 , pp. 776-784
    • Shibata, M.1    Nawa, H.2    Kise, Y.3    Fuyamada, M.4    Yoshida, K.5    Katsumata, A.6
  • 50
    • 84861647924 scopus 로고    scopus 로고
    • Consistency and precision of landmark identification in three-dimensional cone beam computed tomography scans
    • Schlicher W, Nielsen I, Huang JC, Maki K, Hatcher DC, Miller AJ. Consistency and precision of landmark identification in three-dimensional cone beam computed tomography scans. Eur J Orthod 2012;34:263-75.
    • (2012) Eur J Orthod , vol.34 , pp. 263-275
    • Schlicher, W.1    Nielsen, I.2    Huang, J.C.3    Maki, K.4    Hatcher, D.C.5    Miller, A.J.6
  • 51
    • 84861607567 scopus 로고    scopus 로고
    • Repeatability and reproducibility of landmarks-a three-dimensional computed tomography study
    • Titiz I, Laubinger M, Keller T, Hertrich K, Hirschfelder U. Repeatability and reproducibility of landmarks-a three-dimensional computed tomography study. Eur J Orthod 2012;34:276-86.
    • (2012) Eur J Orthod , vol.34 , pp. 276-286
    • Titiz, I.1    Laubinger, M.2    Keller, T.3    Hertrich, K.4    Hirschfelder, U.5
  • 52
    • 84864920814 scopus 로고    scopus 로고
    • A comparison of three-dimensional and two-dimensional cephalometric evaluations of children with cleft lip and palate
    • Tulunoglu O, Esenlik E, Gulsen A, Tulunoglu I. A comparison of three-dimensional and two-dimensional cephalometric evaluations of children with cleft lip and palate. Eur J Dent 2011;5:451-8.
    • (2011) Eur J Dent , vol.5 , pp. 451-458
    • Tulunoglu, O.1    Esenlik, E.2    Gulsen, A.3    Tulunoglu, I.4
  • 53
    • 65149085052 scopus 로고    scopus 로고
    • A comparison between two-dimensional and three-dimensional cephalometry on frontal radiographs and on cone beam computed tomography scans of human skulls
    • van Vlijmen OJ, Maal TJ, Berge SJ, Bronkhorst EM, Katsaros C, Kuijpers-Jagtman AM. A comparison between two-dimensional and three-dimensional cephalometry on frontal radiographs and on cone beam computed tomography scans of human skulls. Eur J Oral Sci 2009;117:300-5.
    • (2009) Eur J Oral Sci , vol.117 , pp. 300-305
    • van Vlijmen, O.J.1    Maal, T.J.2    Berge, S.J.3    Bronkhorst, E.M.4    Katsaros, C.5    Kuijpers-Jagtman, A.M.6
  • 56
    • 0026579856 scopus 로고
    • Craniofacial skeletal measurements based on computed tomography: Part II. Normal values and growth trends
    • Waitzman AA, Posnick JC, Armstrong DC, Pron GE. Craniofacial skeletal measurements based on computed tomography: Part II. Normal values and growth trends. Cleft Palate Craniofac J 1992;29:118-28.
    • (1992) Cleft Palate Craniofac J , vol.29 , pp. 118-128
    • Waitzman, A.A.1    Posnick, J.C.2    Armstrong, D.C.3    Pron, G.E.4
  • 58
    • 84863904771 scopus 로고    scopus 로고
    • A study on the reproducibility of cephalometric landmarks when undertaking a three-dimensional (3D) cephalometric analysis
    • Zamora N, Llamas JM, Cibrian R, Gandia JL, Paredes V. A study on the reproducibility of cephalometric landmarks when undertaking a three-dimensional (3D) cephalometric analysis. Med Oral Patol Oral Cir Bucal 2012;17:e678-88.
    • (2012) Med Oral Patol Oral Cir Bucal , vol.17
    • Zamora, N.1    Llamas, J.M.2    Cibrian, R.3    Gandia, J.L.4    Paredes, V.5
  • 59
    • 84897960034 scopus 로고    scopus 로고
    • European Commission. Guidelines on CBCT for Dental and Maxillofacial Radiology: Evidence Based Guidelines: Radiation Protection Publication; 2012. Available from:
    • European Commission. Guidelines on CBCT for Dental and Maxillofacial Radiology: Evidence Based Guidelines: Radiation Protection Publication; 2012. Available from: http://www.sedentexct.eu/content/guidelines-cbct-dental-and-maxillofacial-radiology.
  • 60
    • 84880204254 scopus 로고    scopus 로고
    • Clinical recommendations regarding use of cone beam computed tomography in orthodontic treatment. Position statement by the American Academy of Oral and Maxillofacial Radiology
    • American Academy of Oral and Maxillofacial Radiology.
    • American Academy of Oral and Maxillofacial Radiology. Clinical recommendations regarding use of cone beam computed tomography in orthodontic treatment. Position statement by the American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol 2013;116:238-57.
    • (2013) Oral Surg Oral Med Oral Pathol Oral Radiol , vol.116 , pp. 238-257
  • 62
    • 84857260226 scopus 로고    scopus 로고
    • Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms
    • Theodorakou C, Walker A, Horner K, Pauwels R, Bogaerts R, Jacobs R et al. Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms. Br J Radiol 2012;85:153-60.
    • (2012) Br J Radiol , vol.85 , pp. 153-160
    • Theodorakou, C.1    Walker, A.2    Horner, K.3    Pauwels, R.4    Bogaerts, R.5    Jacobs, R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.