메뉴 건너뛰기




Volumn 35, Issue 1, 2013, Pages 38-44

Precision of identifying cephalometric landmarks with cone beam computed tomography in vivo

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ANATOMIC LANDMARK; ARTICLE; CEPHALOMETRY; CONE BEAM COMPUTED TOMOGRAPHY; EVALUATION; FACIAL BONE; FEMALE; HUMAN; MALE; METHODOLOGY; OBSERVER VARIATION; RADIOGRAPHY; REPRODUCIBILITY; STANDARD; THREE DIMENSIONAL IMAGING;

EID: 84875123611     PISSN: 01415387     EISSN: 14602210     Source Type: Journal    
DOI: 10.1093/ejo/cjr050     Document Type: Article
Times cited : (51)

References (35)
  • 3
    • 67649628169 scopus 로고    scopus 로고
    • Comparison of reliability in, anatomical landmark identification using two-dimensional, digital cephalometrics and three-dimensional cone beam computed tomography in vivo
    • Chien P.C, Parks E.T, Eraso F, Hartsfield J.K, Roberts W.E, Ofner S.2009 Comparison of reliability in, anatomical landmark identification using two-dimensional, digital cephalometrics and three-dimensional cone beam computed tomography in vivo . Dentomaxillofacial Radiology 38 : 262-273
    • (2009) Dentomaxillofacial Radiology , vol.38 , pp. 262-273
    • Chien, P.C.1    Parks, E.T.2    Eraso, F.3    Hartsfield, J.K.4    Roberts, W.E.5    Ofner, S.6
  • 6
    • 77952429751 scopus 로고    scopus 로고
    • Infiuence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomography
    • Hassan B, Couto Souza P, Jacobs R, de Azambuja Berti S, van der Stelt P.2010 Infiuence of scanning and reconstruction parameters on quality of three-dimensional surface models of the dental arches from cone beam computed tomography . Clinical Oral Investigations 14 : 303-310
    • (2010) Clinical Oral Investigations , vol.14 , pp. 303-310
    • Hassan, B.1    Couto Souza, P.2    Jacobs, R.3    De Azambuja Berti, S.4    Van Der Stelt, P.5
  • 7
    • 67649227108 scopus 로고    scopus 로고
    • Accuracy of three-dimensional measurements obtained from cone beam computed tomography surfacerendered images for cephalometric analysis: Infiuence of patient scanning position
    • Hassan B, van der Stelt P, Sanderink G.2009 Accuracy of three-dimensional measurements obtained from cone beam computed tomography surfacerendered images for cephalometric analysis: infiuence of patient scanning position . European Journal of Orthodontics 31 : 129-134
    • (2009) European Journal of Orthodontics , vol.31 , pp. 129-134
    • Hassan, B.1    Van Der Stelt, P.2    Sanderink, G.3
  • 9
    • 33644877729 scopus 로고    scopus 로고
    • Three-dimensional cone beam computerized tomography in orthodontics
    • Kau C.H, Richmond S, Palomo J.M, Hans M.G.2005 Three-dimensional cone beam computerized tomography in orthodontics . Journal of Orthodontics 32 : 282-293
    • (2005) Journal of Orthodontics , vol.32 , pp. 282-293
    • Kau, C.H.1    Richmond, S.2    Palomo, J.M.3    Hans, M.G.4
  • 10
    • 0030972483 scopus 로고    scopus 로고
    • Comparison of the reliability of craniofacial anatomic landmarks based on cephalometric radiographs and three-dimensional ct scans
    • Kragskov J, Bosch C, Gyldensted C, Sindet-Pedersen S.1997 Comparison of the reliability of craniofacial anatomic landmarks based on cephalometric radiographs and three-dimensional CT scans . Cleft Palate-Craniofacial Journal 34 : 111-116
    • (1997) Cleft Palate-Craniofacial Journal , vol.34 , pp. 111-116
    • Kragskov, J.1    Bosch, C.2    Gyldensted, C.3    Sindet-Pedersen, S.4
  • 11
    • 50949089055 scopus 로고    scopus 로고
    • In vivo comparison of conventional and cone beam ct synthesized cephalograms
    • Kumar V, Ludlow J, Cevidanes L.H.S, Mol A.2008 In Vivo comparison of conventional and cone beam CT synthesized cephalograms . Angle Orthodontist 78 : 873-879
    • (2008) Angle Orthodontist , vol.78 , pp. 873-879
    • Kumar, V.1    Ludlow, J.2    Cevidanes, L.H.S.3    Mol, A.4
  • 14
    • 77955554713 scopus 로고    scopus 로고
    • Acomparative evaluation of cone beam computed tomography (cbct) and multi-slice ct (msct). Part ii: On 3d model accuracy
    • Liang X.et al. 2009 A.comparative evaluation of Cone Beam Computed Tomography (CBCT) and Multi-Slice CT (MSCT). Part II: on 3D model accuracy . European Journal of Radiology 75 : 270-274
    • (2009) European Journal of Radiology , vol.75 , pp. 270-274
    • Liang, X.1
  • 16
    • 34547358852 scopus 로고    scopus 로고
    • Acomparison of jaw dimensional and quality assessments of bone characteristics with cone-beam ct, spiral tomography, and multi-slice spiral ct
    • Loubele M, Guerrero M.E, Jacobs R, Suetens P, van Steenberghe D.2007 A.comparison of jaw dimensional and quality assessments of bone characteristics with cone-beam CT, spiral tomography, and multi-slice spiral CT . International Journal of Oral Maxillofacial Implants 22 : 446-454
    • (2007) International Journal of Oral Maxillofacial Implants , vol.22 , pp. 446-454
    • Loubele, M.1    Guerrero, M.E.2    Jacobs, R.3    Suetens, P.4    Van Steenberghe, D.5
  • 17
    • 52649106470 scopus 로고    scopus 로고
    • Image quality vs radiation dose of four cone beam computed tomography scanners
    • Loubele M.et al. 2008a Image quality vs radiation dose of four cone beam computed tomography scanners . Dentomaxillofacial Radiology 37 : 309-319
    • (2008) Dentomaxillofacial Radiology , vol.37 , pp. 309-319
    • Loubele, M.1
  • 21
    • 0029285719 scopus 로고
    • Natural head position and natural head orientation: Basic considerations in cephalometric analysis and research
    • Lundström A, Lundström F, Lebret L.M, Moorrees C.F 1995 Natural head position and natural head orientation: basic considerations in cephalometric analysis and research . European Journal of Orthodontics 17 : 111-120
    • (1995) European Journal of Orthodontics , vol.17 , pp. 111-120
    • Lundström, A.1    Lundström, F.2    Lebret, L.M.3    Moorrees, C.F.4
  • 25
    • 33751109966 scopus 로고    scopus 로고
    • 3d ct-based cephalometric analysis: 3d cephalometric theoretical concept and software
    • Olszewski R, Cosnard G, Macq B, Mahy P, Reychler H.2006 3D CT-based cephalometric analysis: 3D cephalometric theoretical concept and software . Neuroradiology 48 : 853-862
    • (2006) Neuroradiology , vol.48 , pp. 853-862
    • Olszewski, R.1    Cosnard, G.2    Macq, B.3    Mahy, P.4    Reychler, H.5
  • 27
    • 43449117523 scopus 로고    scopus 로고
    • Linear accuracy and reliability of cone beam ct derived 3-dimensional images constructed using an orthodontic volumetric rendering program
    • Periago D.R, Scarfe W.C, Moshiri M, Scheetz J.P, Silveira A.M, Farman A.G 2008 Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program . Angle Orthodontist 78 : 387-395
    • (2008) Angle Orthodontist , vol.78 , pp. 387-395
    • Periago, D.R.1    Scarfe, W.C.2    Moshiri, M.3    Scheetz, J.P.4    Silveira, A.M.5    Farman, A.G.6
  • 29
    • 0019351396 scopus 로고
    • Acomparison of traditional and computerized methods of cephalometric analysis
    • Richardson A.1981 A.comparison of traditional and computerized methods of cephalometric analysis . European Journal of Orthodontics 1 : 15-20
    • (1981) European Journal of Orthodontics , vol.1 , pp. 15-20
    • Richardson, A.1
  • 32
    • 69249102664 scopus 로고    scopus 로고
    • Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
    • Suomalainen A, Kiljunen T, Käser Y, Peltola J, Kortesniemi M.2009 Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners . Dentomaxillofacial Radiology 38 : 367-378
    • (2009) Dentomaxillofacial Radiology , vol.38 , pp. 367-378
    • Suomalainen, A.1    Kiljunen, T.2    Käser, Y.3    Peltola, J.4    Kortesniemi, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.