Development and comparison of new high-efficiency dry powder inhalers for carrier-free formulations

Author keywords

3D rod array; Computational fluid dynamics (CFD); Excipient enhanced growth (EEG) delivery; Flow rate effects; High efficiency DPI; In vitro inhaler testing; Multiple formulations; Non dimensional specific dissipation (NDSD); PTFE coating; Respiratory drug delivery

Indexed keywords

SALBUTAMOL SULFATE; TERBUTALINE SULFATE;

EID: 84895922767     PISSN: 00223549     EISSN: 15206017     Source Type: Journal    
DOI: 10.1002/jps.23775     Document Type: Article
Times cited : (34)

References (49)
  • 1
    • 21744439532 scopus 로고    scopus 로고
    • Drug delivery devices: Issues in drug development
    • Byron PR. 2004. Drug delivery devices: Issues in drug development. Proc Am Thorac Soc 1:321-328.
    • (2004) Proc Am Thorac Soc , vol.1 , pp. 321-328
    • Byron, P.R.1
  • 3
    • 84859735921 scopus 로고    scopus 로고
    • Developing an efficient and reliable dry powder inhaler for pulmonary drug delivery-A review for multidisciplinary researchers
    • Islam N, Cleary MJ. 2012. Developing an efficient and reliable dry powder inhaler for pulmonary drug delivery-A review for multidisciplinary researchers. Med End Phys 34:409-427.
    • (2012) Med End Phys , vol.34 , pp. 409-427
    • Islam, N.1    Cleary, M.J.2
  • 4
    • 0036586884 scopus 로고    scopus 로고
    • Evolution of dry powder inhaler design, formulation, and performance
    • Newman SP, Busse WW. 2002. Evolution of dry powder inhaler design, formulation, and performance. Respir Med 96:293-304.
    • (2002) Respir Med , vol.96 , pp. 293-304
    • Newman, S.P.1    Busse, W.W.2
  • 5
    • 84856715725 scopus 로고    scopus 로고
    • Vitro tests for aerosol deposition. I. Scaling a physical model of the upper airways to predict drug deposition variation in normal humans
    • Delvadia R, Longest PW, Byron PR. 2012. In vitro tests for aerosol deposition. I. Scaling a physical model of the upper airways to predict drug deposition variation in normal humans. J Aerosol Med 25(1):32-40.
    • (2012) J Aerosol Med , vol.25 , Issue.1 , pp. 32-40
    • Delvadia, R.1    Longest, P.W.2    Byron, P.R.3
  • 6
    • 84862649849 scopus 로고    scopus 로고
    • Comparing MDI and DPI aerosol deposition using in vitro experiments and a new stochastic individual path (SIP) model of the conducting airways
    • Longest PW, Tian G, Walenga RL, Hindle M. 2012. Comparing MDI and DPI aerosol deposition using in vitro experiments and a new stochastic individual path (SIP) model of the conducting airways. Pharm Res 29:1670-1688.
    • (2012) Pharm Res , vol.29 , pp. 1670-1688
    • Longest, P.W.1    Tian, G.2    Walenga, R.L.3    Hindle, M.4
  • 7
    • 34648816355 scopus 로고    scopus 로고
    • In vivo-in vitro comparison of deposition in three mouth-throat models with Qvar and Turbuhaler inhalers
    • Zhang Y, Gilbertson K, Finlay WH. 2007. In vivo-in vitro comparison of deposition in three mouth-throat models with Qvar and Turbuhaler inhalers. J Aerosol Med 20(3):227-235.
    • (2007) J Aerosol Med , vol.20 , Issue.3 , pp. 227-235
    • Zhang, Y.1    Gilbertson, K.2    Finlay, W.H.3
  • 8
    • 84878413637 scopus 로고    scopus 로고
    • In vitro tests for aerosol deposition. II: IVIVCs for different dry powder inhalers in normal adults
    • Delvadia R, Hindle M, Longest PW, Byron PR. 2013. In vitro tests for aerosol deposition. II: IVIVCs for different dry powder inhalers in normal adults. J Aerosol Med Pulm Drug Deliv 26(3):138-144.
    • (2013) J Aerosol Med Pulm Drug Deliv , vol.26 , Issue.3 , pp. 138-144
    • Delvadia, R.1    Hindle, M.2    Longest, P.W.3    Byron, P.R.4
  • 9
    • 33846076698 scopus 로고    scopus 로고
    • Degree of throat deposition can explain the variability in lung deposition of inhaled drugs
    • Borgstrom L, Olsson B, Thorsson L. 2006. Degree of throat deposition can explain the variability in lung deposition of inhaled drugs. J Aerosol Med 19:473-483.
    • (2006) J Aerosol Med , vol.19 , pp. 473-483
    • Borgstrom, L.1    Olsson, B.2    Thorsson, L.3
  • 10
    • 13544253826 scopus 로고    scopus 로고
    • Device selection and outcomes of aerosol therapy: ACCP/ACAAI evidence based guidelines
    • Dolovich MB, Ahrens RC, Hess D. 2005. Device selection and outcomes of aerosol therapy: ACCP/ACAAI evidence based guidelines. Chest 127:335-371.
    • (2005) Chest , vol.127 , pp. 335-371
    • Dolovich, M.B.1    Ahrens, R.C.2    Hess, D.3
  • 11
    • 33645473085 scopus 로고    scopus 로고
    • Advances in aerosols: Adult respiratory disease
    • Smaldone GC. 2006. Advances in aerosols: Adult respiratory disease. J Aerosol Med 19(1):36-46.
    • (2006) J Aerosol Med , vol.19 , Issue.1 , pp. 36-46
    • Smaldone, G.C.1
  • 14
    • 77955452827 scopus 로고    scopus 로고
    • Inhalation adjuvant therapy for lung cancer
    • Yi DD, Wiedmann TS. 2010. Inhalation adjuvant therapy for lung cancer. J Aerosol Med Pulm Drug Deliv 23(4):181-187.
    • (2010) J Aerosol Med Pulm Drug Deliv , vol.23 , Issue.4 , pp. 181-187
    • Yi, D.D.1    Wiedmann, T.S.2
  • 15
    • 82255167120 scopus 로고    scopus 로고
    • Pediatric aerosol therapy: New devices and new drugs
    • Rubin BK. 2011. Pediatric aerosol therapy: New devices and new drugs. Respir Care 56(9):1411-1421.
    • (2011) Respir Care , vol.56 , Issue.9 , pp. 1411-1421
    • Rubin, B.K.1
  • 16
  • 17
    • 0033062076 scopus 로고    scopus 로고
    • A critical comparison of the dose delivery characteristics of four alternative inhalation devices delivering salbutamol: Pressurized metered dose inhaler, Diskus inhaler, Diskhaler inhaler, and Turbuhaler inhaler
    • Prime D, Grant AC, Slater AL, Woodhouse RN. 1999. A critical comparison of the dose delivery characteristics of four alternative inhalation devices delivering salbutamol: Pressurized metered dose inhaler, Diskus inhaler, Diskhaler inhaler, and Turbuhaler inhaler. J Aerosol Med 12(2):75-84.
    • (1999) J Aerosol Med , vol.12 , Issue.2 , pp. 75-84
    • Prime, D.1    Grant, A.C.2    Slater, A.L.3    Woodhouse, R.N.4
  • 19
    • 0030581128 scopus 로고    scopus 로고
    • Inhalation characteristics and their effects on in vitro drug delivery from dry powder inhalers Part 2: Effect of peak flow rate (PIFR) and inspiration time on the in vitro drug release from three different types of commercial dry powder inhalers
    • de Boer AH, Gjaltema D, Hagedoorn P. 1996. Inhalation characteristics and their effects on in vitro drug delivery from dry powder inhalers Part 2: Effect of peak flow rate (PIFR) and inspiration time on the in vitro drug release from three different types of commercial dry powder inhalers. Int J Pharm 138:45-56.
    • (1996) Int J Pharm , vol.138 , pp. 45-56
    • De Boer, A.H.1    Gjaltema, D.2    Hagedoorn, P.3
  • 20
    • 1542291134 scopus 로고    scopus 로고
    • Predicting extrathoracic deposition from dry powder inhalers
    • DeHaan WH, Finlay WH. 2004. Predicting extrathoracic deposition from dry powder inhalers. J Aerosol Sci 35:309-331.
    • (2004) J Aerosol Sci , vol.35 , pp. 309-331
    • Dehaan, W.H.1    Finlay, W.H.2
  • 21
    • 84949237016 scopus 로고    scopus 로고
    • Performance of combination drug and hygroscopic excipient submicrometer particles from a softmist inhaler in a characteristic model of the airways
    • Longest PW, Tian G, Li X, Son Y-J, Hindle M. 2012. Performance of combination drug and hygroscopic excipient submicrometer particles from a softmist inhaler in a characteristic model of the airways. Ann Biomed Eng 40(12):2596-2610.
    • (2012) Ann Biomed Eng , vol.40 , Issue.12 , pp. 2596-2610
    • Longest, P.W.1    Tian, G.2    Li, X.3    Son, Y.-J.4    Hindle, M.5
  • 22
    • 84861927754 scopus 로고    scopus 로고
    • Condensational growth of combination drug-excipient submicrometer particles: Comparison of CFD predictions with experimental results
    • Longest PW, Hindle M. 2012. Condensational growth of combination drug-excipient submicrometer particles: Comparison of CFD predictions with experimental results. Pharm Res 29:707-721.
    • (2012) Pharm Res , vol.29 , pp. 707-721
    • Longest, P.W.1    Hindle, M.2
  • 23
    • 84864668511 scopus 로고    scopus 로고
    • Condensational growth of combination drug-excipient submicrometer particles for targeted high efficiency pulmonary delivery: Evaluation of formulation and delivery device
    • Hindle M, Longest PW. 2012. Condensational growth of combination drug-excipient submicrometer particles for targeted high efficiency pulmonary delivery: Evaluation of formulation and delivery device. J Pharm Pharmacol 64(9):1254-1263.
    • (2012) J Pharm Pharmacol , vol.64 , Issue.9 , pp. 1254-1263
    • Hindle, M.1    Longest, P.W.2
  • 24
    • 85012432882 scopus 로고    scopus 로고
    • Numerical model to characterize the size increase of combination drug and hygroscopic excipient nanoparticle aerosols
    • Longest PW, Hindle M. 2011. Numerical model to characterize the size increase of combination drug and hygroscopic excipient nanoparticle aerosols. Aerosol Sci Technol 45:884-899.
    • (2011) Aerosol Sci Technol , vol.45 , pp. 884-899
    • Longest, P.W.1    Hindle, M.2
  • 25
    • 84878529022 scopus 로고    scopus 로고
    • Targeting aerosol deposition to and within the lung airways using excipient enhanced growth
    • Tian G, Longest PW, Li X, Hindle M. 2013. Targeting aerosol deposition to and within the lung airways using excipient enhanced growth. J Aerosol Med Pulm Drug Deliv 26(5):248-265.
    • (2013) J Aerosol Med Pulm Drug Deliv , vol.26 , Issue.5 , pp. 248-265
    • Tian, G.1    Longest, P.W.2    Li, X.3    Hindle, M.4
  • 26
    • 84873048683 scopus 로고    scopus 로고
    • Aerosolization characteristics of dry powder inhaler formulations for the excipient enhanced growth (EEG) application: Effect of spray drying process conditions on aerosol performance
    • Son Y-J, Longest PW, Hindle M. 2013. Aerosolization characteristics of dry powder inhaler formulations for the excipient enhanced growth (EEG) application: Effect of spray drying process conditions on aerosol performance. Int J Pharm 443:137-145.
    • (2013) Int J Pharm , vol.443 , pp. 137-145
    • Son, Y.-J.1    Longest, P.W.2    Hindle, M.3
  • 27
    • 84877664887 scopus 로고    scopus 로고
    • Evaluation and modification of commercial dry powder inhalers for the aerosolization of submicrometer excipient enhanced growth (EEG) formulation
    • Son Y-J, Longest PW, Hindle M. 2013. Evaluation and modification of commercial dry powder inhalers for the aerosolization of submicrometer excipient enhanced growth (EEG) formulation. Eur J Pharm Sci 49:390-399.
    • (2013) Eur J Pharm Sci , vol.49 , pp. 390-399
    • Son, Y.-J.1    Longest, P.W.2    Hindle, M.3
  • 28
    • 84896736547 scopus 로고    scopus 로고
    • Development of a high efficiency dry powder inhaler: Effects of a new capsule orientation and surface coatings
    • DOI:10.1007/s11095-013-1165-6
    • Behara SRB, Farkas DR, Hindle M, Longest PW. 2013. Development of a high efficiency dry powder inhaler: Effects of a new capsule orientation and surface coatings. Pharm Res. DOI:10.1007/s11095-013-1165-6.
    • (2013) Pharm Res
    • Behara, S.R.B.1    Farkas, D.R.2    Hindle, M.3    Longest, P.W.4
  • 29
    • 84877736373 scopus 로고    scopus 로고
    • Aerodynamic factors responsible for the deaggregation of carrier-free drug powders to form micrometer and submicrometer aerosols
    • Longest PW, Son Y-J, Holbrook LT, Hindle M. 2013. Aerodynamic factors responsible for the deaggregation of carrier-free drug powders to form micrometer and submicrometer aerosols. Pharm Res 30:1608-1627.
    • (2013) Pharm Res , vol.30 , pp. 1608-1627
    • Longest, P.W.1    Son, Y.-J.2    Holbrook, L.T.3    Hindle, M.4
  • 30
    • 0028814516 scopus 로고
    • Dose emissions from marketed dry powder inhalers
    • Hindle M, Byron PR. 1995. Dose emissions from marketed dry powder inhalers. Int J Pharm 116(2):169-177.
    • (1995) Int J Pharm , vol.116 , Issue.2 , pp. 169-177
    • Hindle, M.1    Byron, P.R.2
  • 31
    • 84895918178 scopus 로고    scopus 로고
    • Physical tests and determinations: Aerosols, nasal sprays, metered-dose inhalers, and dry powder inhalers
    • USP, Rockville, Maryland: United States Pharmacopeial Convention
    • USP. 2005. Physical tests and determinations: Aerosols, nasal sprays, metered-dose inhalers, and dry powder inhalers. United States Pharmacopeia First Supplement, 28-NF, General Chapter (601). Rockville, Maryland: United States Pharmacopeial Convention, pp 3298-3316.
    • (2005) United States Pharmacopeia First Supplement, 28-NF, General Chapter (601) , pp. 3298-3316
  • 33
    • 70349286796 scopus 로고    scopus 로고
    • Quantitative analysis and design of a spray aerosol inhaler. Part 1: Effects of dilution air inlets and flow paths
    • Longest PW, Hindle M. 2009. Quantitative analysis and design of a spray aerosol inhaler. Part 1: Effects of dilution air inlets and flow paths. J Aerosol Med Pulm Drug Deliv 22(3):271-283.
    • (2009) J Aerosol Med Pulm Drug Deliv , vol.22 , Issue.3 , pp. 271-283
    • Longest, P.W.1    Hindle, M.2
  • 34
    • 24044542653 scopus 로고    scopus 로고
    • Influence of air flow on the performance of a dry powder inhaler using computational and experimental analyses
    • Coates MS, Chan H-K, Fletcher DF, Raper JA. 2005. Influence of air flow on the performance of a dry powder inhaler using computational and experimental analyses. Pharm Res 22(9):1445-1453.
    • (2005) Pharm Res , vol.22 , Issue.9 , pp. 1445-1453
    • Coates, M.S.1    Chan, H.-K.2    Fletcher, D.F.3    Raper, J.A.4
  • 35
    • 33745056503 scopus 로고    scopus 로고
    • Effect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 2: Air inlet size
    • Coates MS, Chan H-K, Fletcher DF, Raper JA. 2006. Effect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 2: Air inlet size. J Pharm Sci 95(6):1382-1392.
    • (2006) J Pharm Sci , vol.95 , Issue.6 , pp. 1382-1392
    • Coates, M.S.1    Chan, H.-K.2    Fletcher, D.F.3    Raper, J.A.4
  • 36
    • 8644282632 scopus 로고    scopus 로고
    • Effect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 1: Grid structure and mouthpiece length
    • Coates MS, Fletcher DF, Chan H-K, Raper JA. 2004. Effect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 1: Grid structure and mouthpiece length. J Pharm Sci 93(11):2863-2876.
    • (2004) J Pharm Sci , vol.93 , Issue.11 , pp. 2863-2876
    • Coates, M.S.1    Fletcher, D.F.2    Chan, H.-K.3    Raper, J.A.4
  • 38
    • 67549098260 scopus 로고    scopus 로고
    • Evaluation of the respimat soft mist inhaler using a concurrent CFD and in vitro approach
    • Longest PW, Hindle M. 2009. Evaluation of the respimat soft mist inhaler using a concurrent CFD and in vitro approach. J Aerosol Med Pulm Drug Deliv 22(2):99-112.
    • (2009) J Aerosol Med Pulm Drug Deliv , vol.22 , Issue.2 , pp. 99-112
    • Longest, P.W.1    Hindle, M.2
  • 39
    • 45049088663 scopus 로고    scopus 로고
    • Comparison of ambient and spray aerosol deposition in a standard induction port and more realistic mouth-throat geometry
    • Longest PW, Hindle M, Das Choudhuri S, Xi J. 2008. Comparison of ambient and spray aerosol deposition in a standard induction port and more realistic mouth-throat geometry. J Aerosol Sci 39:572-591.
    • (2008) J Aerosol Sci , vol.39 , pp. 572-591
    • Longest, P.W.1    Hindle, M.2    Das Choudhuri, S.3    Xi, J.4
  • 40
    • 80051622991 scopus 로고    scopus 로고
    • Development of a stochastic individual path (SIP) model for predicting the tracheobronchial deposition of pharmaceutical aerosols: Effects of transient inhalation and sampling the airways
    • Tian G, Longest PW, Su G, Walenga RL, Hindle M. 2011. Development of a stochastic individual path (SIP) model for predicting the tracheobronchial deposition of pharmaceutical aerosols: Effects of transient inhalation and sampling the airways. J Aerosol Sci 42:781-799.
    • (2011) J Aerosol Sci , vol.42 , pp. 781-799
    • Tian, G.1    Longest, P.W.2    Su, G.3    Walenga, R.L.4    Hindle, M.5
  • 41
    • 80051905596 scopus 로고    scopus 로고
    • Kinetics of emitted mass-A study with three dry powder inhaler devices. Chem Eng Sci 66(21):5284-5292.2006. Emitted dose estimates from Seretide (R) Diskus (R) and Symbicort (R) Turbuhaler (R) following inhalation by severe asthmatics
    • Behara SRB, Kippax P, Larson I, Morton DAV, Stewart P. 2011. Kinetics of emitted mass-A study with three dry powder inhaler devices. Chem Eng Sci 66(21):5284-5292.2006. Emitted dose estimates from Seretide (R) Diskus (R) and Symbicort (R) Turbuhaler (R) following inhalation by severe asthmatics. Int J Pharm 316(1-2):131-137.
    • (2011) Int J Pharm , vol.316 , Issue.1-2 , pp. 131-137
    • Behara, S.R.B.1    Kippax, P.2    Larson, I.3    Morton, D.A.V.4    Stewart, P.5
  • 42
    • 75749105483 scopus 로고    scopus 로고
    • Electrostatics of pharmaceutical inhalation aerosols
    • Kwok PCL, Chan HK. 2009. Electrostatics of pharmaceutical inhalation aerosols. J Pharm Pharmacol 61(12):1587-1599.
    • (2009) J Pharm Pharmacol , vol.61 , Issue.12 , pp. 1587-1599
    • Kwok, P.C.L.1    Chan, H.K.2
  • 43
    • 0030982757 scopus 로고    scopus 로고
    • Aerosol electrostatics I: Properties of fine powders before and after aerosolization by dry powder inhalers
    • Byron PR, Peart J, Staniforth JN. 1997. Aerosol electrostatics I: Properties of fine powders before and after aerosolization by dry powder inhalers. Pharm Res 14(6):698-705.
    • (1997) Pharm Res , vol.14 , Issue.6 , pp. 698-705
    • Byron, P.R.1    Peart, J.2    Staniforth, J.N.3
  • 45
    • 21244438369 scopus 로고    scopus 로고
    • The role of capsule on the performance of a dry powder inhaler using computational and experimental analyses
    • Coates MS, Fletcher DF, Chan H-K, Raper JA. 2005. The role of capsule on the performance of a dry powder inhaler using computational and experimental analyses. Pharm Res 22(6):923-932.
    • (2005) Pharm Res , vol.22 , Issue.6 , pp. 923-932
    • Coates, M.S.1    Fletcher, D.F.2    Chan, H.-K.3    Raper, J.A.4
  • 46
    • 84869139244 scopus 로고    scopus 로고
    • Effect of device design on the in vitro performance and comparability for capsule-based dry powder inhalers
    • Shur J, Lee SL, Adams W, Lionberger R, Tibbatts J, Price R. 2012. Effect of device design on the in vitro performance and comparability for capsule-based dry powder inhalers. AAPS J 14(4):667-676.
    • (2012) AAPS J , vol.14 , Issue.4 , pp. 667-676
    • Shur, J.1    Lee, S.L.2    Adams, W.3    Lionberger, R.4    Tibbatts, J.5    Price, R.6
  • 47
    • 0037032434 scopus 로고    scopus 로고
    • Deagglomeration of dry powder pharmaceutical aerosols
    • Voss AP, Finlay WH. 2002. Deagglomeration of dry powder pharmaceutical aerosols. Int J Pharm 248:39-40.
    • (2002) Int J Pharm , vol.248 , pp. 39-40
    • Voss, A.P.1    Finlay, W.H.2
  • 48
    • 78349311366 scopus 로고    scopus 로고
    • Influence of size and surface roughness of large lactose carrier particles in dry powder inhaler formulations
    • Donovan MJ, Smyth HDC. 2010. Influence of size and surface roughness of large lactose carrier particles in dry powder inhaler formulations. Int J Pharm 402:1-9.
    • (2010) Int J Pharm , vol.402 , pp. 1-9
    • Donovan, M.J.1    Smyth, H.D.C.2
  • 49
    • 0001817527 scopus 로고
    • Factors influencing the dispersion of dry powders as aerosols
    • Hickey AJ, Concession NM, Van Oort M, Platz M. 1994. Factors influencing the dispersion of dry powders as aerosols. Pharm Tech 8:58-82.
    • (1994) Pharm Tech , vol.8 , pp. 58-82
    • Hickey, A.J.1    Concession, N.M.2    Van Oort, M.3    Platz, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.