메뉴 건너뛰기




Volumn 16, Issue 1, 2000, Pages 178-183

Scintigraphic comparison of budesonide deposition from two dry powder inhalers

Author keywords

Budesonide; Dry powder inhaler; Gamma scintigraphy; Total and regional lung deposition

Indexed keywords

BUDESONIDE; CHLOROFLUOROCARBON;

EID: 0033911733     PISSN: 09031936     EISSN: None     Source Type: Journal    
DOI: 10.1034/j.1399-3003.2000.16a29.x     Document Type: Article
Times cited : (107)

References (27)
  • 1
    • 0029030051 scopus 로고
    • Medical aerosol inhalers: Past, present and future
    • 1. Clark AR. Medical aerosol inhalers: past, present and future. Aerosol Sci Technol 1995; 22: 374-391.
    • (1995) Aerosol Sci Technol , vol.22 , pp. 374-391
    • Clark, A.R.1
  • 2
    • 0028031785 scopus 로고
    • Effect of different modes of inhalation on drug delivery from a dry powder inhaler
    • Newman SP, Hollingworth A, Clark AR. Effect of different modes of inhalation on drug delivery from a dry powder inhaler. Int J Pharm 1994; 102: 127-132.
    • (1994) Int J Pharm , vol.102 , pp. 127-132
    • Newman, S.P.1    Hollingworth, A.2    Clark, A.R.3
  • 3
    • 0002528755 scopus 로고    scopus 로고
    • Asta medica multidose dry powder inhaler
    • Dalby RN, Byron PR, Farr SJ, eds. Buffalo Grove, IL, USA, Interpharm Press
    • Berner B, Fyrnys B, de Boer A, Göttenhauer W, Wolf-Heuss E. Asta Medica multidose dry powder inhaler. In: Dalby RN, Byron PR, Farr SJ, eds. Respiratory Drug Delivery VI. Buffalo Grove, IL, USA, Interpharm Press, 1998; pp. 475-477.
    • (1998) Respiratory Drug Delivery VI , pp. 475-477
    • Berner, B.1    Fyrnys, B.2    De Boer, A.3    Göttenhauer, W.4    Wolf-Heuss, E.5
  • 4
    • 0028929044 scopus 로고
    • Comparison of gamma scintigraphy and a pharmaco-kinetic technique for assessing the pulmonary deposition of terbutaline sulphate delivered by pressurised metered dose inhaler
    • Newman SP, Steed KP, Hooper G, Källén A, Borgström L. Comparison of gamma scintigraphy and a pharmaco-kinetic technique for assessing the pulmonary deposition of terbutaline sulphate delivered by pressurised metered dose inhaler. Pharm Res 1995; 12: 231-236.
    • (1995) Pharm Res , vol.12 , pp. 231-236
    • Newman, S.P.1    Steed, K.P.2    Hooper, G.3    Källén, A.4    Borgström, L.5
  • 5
    • 0027478534 scopus 로고
    • Scintigraphic assessment of therapeutic aerosols
    • Newman SP. Scintigraphic assessment of therapeutic aerosols. Crit Rev Ther Drug Carrier Syst 1993; 10: 65-109.
    • (1993) Crit Rev Ther Drug Carrier Syst , vol.10 , pp. 65-109
    • Newman, S.P.1
  • 6
    • 0031837896 scopus 로고    scopus 로고
    • Scintigraphic assessment of pulmonary delivery systems
    • Newman SP. Scintigraphic assessment of pulmonary delivery systems. Pharm Tech 1998; 22: 78-94.
    • (1998) Pharm Tech , vol.22 , pp. 78-94
    • Newman, S.P.1
  • 9
    • 0028097650 scopus 로고
    • A comparison of the lung deposition of salbutamol inhaled from a new dry powder inhaler, at two inhaled flow rates
    • Pitcairn GR, Lunghetti G, Ventura P, Newman SP. A comparison of the lung deposition of salbutamol inhaled from a new dry powder inhaler, at two inhaled flow rates. Int J Pharm 1994; 102: 11-18.
    • (1994) Int J Pharm , vol.102 , pp. 11-18
    • Pitcairn, G.R.1    Lunghetti, G.2    Ventura, P.3    Newman, S.P.4
  • 10
    • 0031455263 scopus 로고    scopus 로고
    • Scintigraphic assessment of drug delivery from the ultrahaler dry powder inhaler
    • Pitcairn GR, Lim J, Hollingworth A, Newman SP. Scintigraphic assessment of drug delivery from the Ultrahaler dry powder inhaler. J Aerosol Med 1997; 10: 295-306.
    • (1997) J Aerosol Med , vol.10 , pp. 295-306
    • Pitcairn, G.R.1    Lim, J.2    Hollingworth, A.3    Newman, S.P.4
  • 11
    • 0029935248 scopus 로고    scopus 로고
    • Characteristics of radiolabelled versus unlabelled formulations
    • Newman SP. Characteristics of radiolabelled versus unlabelled formulations. J Aerosol Med 1996; 9 (Suppl. 1): S37-S47.
    • (1996) J Aerosol Med , vol.9 , Issue.SUPPL. 1
    • Newman, S.P.1
  • 12
    • 0030819111 scopus 로고    scopus 로고
    • Tissue attenuation corrections in gamma scintigraphy
    • Pitcairn GR, Newman SP. Tissue attenuation corrections in gamma scintigraphy. J Aerosol Med 1997; 10: 187-198.
    • (1997) J Aerosol Med , vol.10 , pp. 187-198
    • Pitcairn, G.R.1    Newman, S.P.2
  • 13
    • 0024433602 scopus 로고
    • Pressurised aerosol deposition in the human lung with and without an "open" spacer
    • Newman SP, Clark SR, Talaee N, Clarke SW. Pressurised aerosol deposition in the human lung with and without an "open" spacer. Thorax 1989; 44: 706-710.
    • (1989) Thorax , vol.44 , pp. 706-710
    • Newman, S.P.1    Clark, S.R.2    Talaee, N.3    Clarke, S.W.4
  • 15
    • 0031026029 scopus 로고    scopus 로고
    • New guidelines on asthma management
    • Keeley D, Rees J. New guidelines on asthma management. BMJ 1997; 314: 315-316.
    • (1997) BMJ , vol.314 , pp. 315-316
    • Keeley, D.1    Rees, J.2
  • 16
    • 0031034624 scopus 로고    scopus 로고
    • British guidelines on asthma management: 1995 review and position statement
    • British Asthma Guidelines Coordinating Committee. British guidelines on asthma management: 1995 review and position statement. Thorax 1997; 52: S1-S24.
    • (1997) Thorax , vol.52
  • 17
    • 0029785420 scopus 로고    scopus 로고
    • Delivery devices for inhaled asthma medication
    • Selroos O, Pietinalho A, Riska H. Delivery devices for inhaled asthma medication. Clin Immunother 1996; 6: 273-299.
    • (1996) Clin Immunother , vol.6 , pp. 273-299
    • Selroos, O.1    Pietinalho, A.2    Riska, H.3
  • 18
    • 0030987528 scopus 로고    scopus 로고
    • Airway deposition and airway effects of antiasthma drugs delivered from metered dose inhalers
    • Pauwels R, Newman SP, Borgström L. Airway deposition and airway effects of antiasthma drugs delivered from metered dose inhalers. Eur Respir J 1997; 10: 2127-2138.
    • (1997) Eur Respir J , vol.10 , pp. 2127-2138
    • Pauwels, R.1    Newman, S.P.2    Borgström, L.3
  • 19
    • 0033072264 scopus 로고    scopus 로고
    • Assessing lung deposition of inhaled medications
    • Snell NJC, Ganderton D. Assessing lung deposition of inhaled medications. Respir Med 1999; 93: 123-133.
    • (1999) Respir Med , vol.93 , pp. 123-133
    • Snell, N.J.C.1    Ganderton, D.2
  • 21
    • 0024584103 scopus 로고
    • Deposition and clinical efficacy of terbutaline sulphate from turbuhaler, a new multi-dose powder inhaler
    • Newman SP, Morén F, Trofast E, Talaee N, Clark SW. Deposition and clinical efficacy of terbutaline sulphate from Turbuhaler, a new multi-dose powder inhaler. Eur Respir J 1989; 2: 247-252.
    • (1989) Eur Respir J , vol.2 , pp. 247-252
    • Newman, S.P.1    Morén, F.2    Trofast, E.3    Talaee, N.4    Clark, S.W.5
  • 22
    • 0027986957 scopus 로고
    • Lung deposition of budesonide from turbuhaler is twice that from a pressurised metered dose inhaler
    • Thorsson L, Edsbäcker S, Conradson T-B. Lung deposition of budesonide from Turbuhaler is twice that from a pressurised metered dose inhaler. Eur Respir J 1994; 7: 1839-1844.
    • (1994) Eur Respir J , vol.7 , pp. 1839-1844
    • Thorsson, L.1    Edsbäcker, S.2    Conradson, T.-B.3
  • 23
    • 0028354478 scopus 로고
    • Lung deposition of budesonide inhaled via turbuhaler: A comparison with terbutaline sulphate in normal subjects
    • Borgström L, Bondesson E, Morén F, Trofast E, Newman SP. Lung deposition of budesonide inhaled via Turbuhaler: a comparison with terbutaline sulphate in normal subjects. Eur Respir J 1994; 7: 69-73.
    • (1994) Eur Respir J , vol.7 , pp. 69-73
    • Borgström, L.1    Bondesson, E.2    Morén, F.3    Trofast, E.4    Newman, S.P.5
  • 24
    • 0029972560 scopus 로고    scopus 로고
    • The inhalation device influences lung deposition and bronchodilating effects of terbutaline
    • Borgström L, Derom E, Stahl E, Wahlin-Boll E, Pauwels R. The inhalation device influences lung deposition and bronchodilating effects of terbutaline. Am J Respir Crit Care Med 1996; 153: 1636-1640.
    • (1996) Am J Respir Crit Care Med , vol.153 , pp. 1636-1640
    • Borgström, L.1    Derom, E.2    Stahl, E.3    Wahlin-Boll, E.4    Pauwels, R.5
  • 25
    • 0027159864 scopus 로고
    • Lung deposition patterns of directly labelled salbutamol in normal subjects and in patients with reversible airways obstruction
    • Melchor R, Biddiscombe MF, Mak VHF, Short MD, Spiro SG. Lung deposition patterns of directly labelled salbutamol in normal subjects and in patients with reversible airways obstruction. Thorax 1993; 48: 506-511.
    • (1993) Thorax , vol.48 , pp. 506-511
    • Melchor, R.1    Biddiscombe, M.F.2    Mak, V.H.F.3    Short, M.D.4    Spiro, S.G.5
  • 26
    • 0001413022 scopus 로고    scopus 로고
    • Effect of inhalation flow profiles on the deposition of radiolabelled bDP from a novel dry powder inhaler (clickhaler), a conventional metered dose inhaler and MDI plus spacer
    • Dalby RN, Byron PR, Fair SJ, eds. Buffalo Grove, IL, USA, Interpharm Press
    • Warren SJ, Taylor G. Effect of inhalation flow profiles on the deposition of radiolabelled BDP from a novel dry powder inhaler (Clickhaler), a conventional metered dose inhaler and MDI plus spacer. In: Dalby RN, Byron PR, Fair SJ, eds. Respiratory Drug Delivery VI. Buffalo Grove, IL, USA, Interpharm Press, 1998; pp. 453-455.
    • (1998) Respiratory Drug Delivery VI , pp. 453-455
    • Warren, S.J.1    Taylor, G.2
  • 27
    • 0002876090 scopus 로고    scopus 로고
    • Understanding regional lung deposition in gamma scintigraphy
    • Dalby RN, Byron PR, Farr SJ, eds. Buffalo Grove, IL, USA, Interpharm Press
    • Newman SP, Hirst PH, Pitcairn GR, Clark AR. Understanding regional lung deposition in gamma scintigraphy. In: Dalby RN, Byron PR, Farr SJ, eds. Respiratory Drug Delivery VI. Buffalo Grove, IL, USA, Interpharm Press, 1998; pp. 9-15.
    • (1998) Respiratory Drug Delivery Vi , pp. 9-15
    • Newman, S.P.1    Hirst, P.H.2    Pitcairn, G.R.3    Clark, A.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.