메뉴 건너뛰기




Volumn 22, Issue 5, 2013, Pages 534-539

Influence of different maintenance times of torque application on the removal torque values to loosen the prosthetic abutment screws of external hexagon implants

Author keywords

abutment screw; dental implants; detorque; removal torque

Indexed keywords

TOOTH IMPLANT;

EID: 84885174435     PISSN: 10566163     EISSN: None     Source Type: Journal    
DOI: 10.1097/ID.0b013e31829e548d     Document Type: Article
Times cited : (4)

References (38)
  • 1
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment fro. The time of prosthesis placement to the first annual checkup
    • Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: A study of treatment fro. The time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants. 1991;6:270-276.
    • (1991) J Oral Maxillofac Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 2
    • 84857375438 scopus 로고    scopus 로고
    • Long-term outcome of cemented versus screw-retained implant-supported partial restorations
    • Nissan J, Narobai D, Gross O, et al. Long-term outcome of cemented versus screw-retained implant-supported partial restorations. Int J Oral Maxillofac Implants. 2011;26:1102-1107.
    • (2011) J Oral Maxillofac Implants , vol.26 , pp. 1102-1107
    • Nissan, J.1    Narobai, D.2    Gross, O.3
  • 3
    • 0026125062 scopus 로고
    • Osseointegrated implants for single tooth replacement: A 1-year report from a multicenter prospective study
    • Jemt T, Laney WR, Harris D, et al. Osseointegrated implants for single tooth replacement: A 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants. 1991;6:29-36.
    • (1991) J Oral Maxillofac Implants , vol.6 , pp. 29-36
    • Jemt, T.1    Laney, W.R.2    Harris, D.3
  • 4
  • 5
    • 0031609120 scopus 로고    scopus 로고
    • Prosthodontic problems and limitations associated with osseointegration
    • Taylor TD. Prosthodontic problems and limitations associated with osseointegration. J Prosthet Dent. 1998;79:74-78.
    • (1998) J Prosthet Dent , vol.79 , pp. 74-78
    • Taylor, T.D.1
  • 6
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants. 1994;9:169-178.
    • (1994) J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 8
    • 0033158898 scopus 로고    scopus 로고
    • Multicenter retrospective analysis of the ITI implant system used for singletooth replacements: Results of loading for 2 or more years
    • Levine RA, Clem DS III, Wilson TG Jr, et al. Multicenter retrospective analysis of the ITI implant system used for singletooth replacements: Results of loading for 2 or more years. Int J Oral Maxillofac Implants. 1999;14:516-520.
    • (1999) J Oral Maxillofac Implants , vol.14 , pp. 516-520
    • Levine, R.A.1    Clem, D.S.2    Wilson Jr., T.G.3
  • 9
    • 0026921977 scopus 로고
    • Loads and designs of screw joints for single crowns supported by osseointegrated implants
    • Jörnéus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants. 1992;7:353-359.
    • (1992) J Oral Maxillofac Implants , vol.7 , pp. 353-359
    • Jörnéus, L.1    Jemt, T.2    Carlsson, L.3
  • 10
    • 33748550640 scopus 로고    scopus 로고
    • Fixed partial prostheses supported by 2 or 3 implants: A retrospective study up to 18 years
    • Eliasson A, Eriksson T, Johansson A, et al. Fixed partial prostheses supported by 2 or 3 implants: A retrospective study up to 18 years. Int J Oral Maxillofac Implants. 2006;21:567-574.
    • (2006) J Oral Maxillofac Implants , vol.21 , pp. 567-574
    • Eliasson, A.1    Eriksson, T.2    Johansson, A.3
  • 11
    • 63249086080 scopus 로고    scopus 로고
    • Relation between implant/ abutment vertical misfit and torque loss of abutment screws
    • Barbosa GA, Bernardes SR, das Neves FD, et al. Relation between implant/ abutment vertical misfit and torque loss of abutment screws. Braz Dent J. 2008;19:358-363.
    • (2008) Braz Dent J , vol.19 , pp. 358-363
    • Barbosa, G.A.1    Bernardes, S.R.2    Das Neves, F.D.3
  • 12
    • 67650359881 scopus 로고    scopus 로고
    • Prosthetic screw torque removal values in implants retained as cast bar superstructures or bars modified be the Cresco Ti Precision technique-A comparative in vivo study
    • Schmitt J, Holst S, Eitner S, et al. Prosthetic screw torque removal values in implants retained as cast bar superstructures or bars modified be the Cresco Ti Precision technique-A comparative in vivo study. Int J Prosthodont. 2009;22:193-200.
    • (2009) J Prosthodont , vol.22 , pp. 193-200
    • Schmitt, J.1    Holst, S.2    Eitner, S.3
  • 13
    • 68949159617 scopus 로고    scopus 로고
    • Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants
    • Tsuge T, Hagiwara Y. Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants. Dent Mater J. 2009; 28:373-381.
    • (2009) Dent Mater J , vol.28 , pp. 373-381
    • Tsuge, T.1    Hagiwara, Y.2
  • 14
    • 80052343977 scopus 로고    scopus 로고
    • Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology
    • Guzaitis KL, Knoernschild KL, Viana MA. Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology. J Prosthet Dent. 2011;106:159-169.
    • (2011) J Prosthet Dent , vol.106 , pp. 159-169
    • Guzaitis, K.L.1    Knoernschild, K.L.2    Viana, M.A.3
  • 15
    • 79955758324 scopus 로고    scopus 로고
    • Evaluation of screw loosening on new abutment screws and after successive tightening
    • Barbosa GS, Silva-Neto JP, Simamoto-Júnior PC, et al. Evaluation of screw loosening on new abutment screws and after successive tightening. Braz Dent J. 2011;22:51-55.
    • (2011) Braz Dent J , vol.22 , pp. 51-55
    • Barbosa, G.S.1    Silva-Neto, J.P.2    Simamoto-Júnior, P.C.3
  • 16
    • 84866485762 scopus 로고    scopus 로고
    • The effect of clockwise and counterclockwise twisting moments on abutment screw loosening
    • Yao KT, Kao HC, Cheng CK, et al. The effect of clockwise and counterclockwise twisting moments on abutment screw loosening. Clin Oral Implants Res. 2012;23:1181-1186.
    • (2012) Clin Oral Implants Res , vol.23 , pp. 1181-1186
    • Yao, K.T.1    Kao, H.C.2    Cheng, C.K.3
  • 17
    • 0029421452 scopus 로고
    • Practical clinical guidelines to prevent screw loosening
    • Hurson S. Practical clinical guidelines to prevent screw loosening. Int J Dent Symp. 1995;3:22-25.
    • (1995) J Dent Symp , vol.3 , pp. 22-25
    • Hurson, S.1
  • 18
    • 7944225425 scopus 로고    scopus 로고
    • Screw loosening for standard and wide diameter implants in partially edentulous cases: 3-to 7-year longitudinal data
    • Cho SC, Small PN, Elian N, et al. Screw loosening for standard and wide diameter implants in partially edentulous cases: 3-to 7-year longitudinal data. Implant Dent. 2004;13:245-250.
    • (2004) Implant Dent , vol.13 , pp. 245-250
    • Cho, S.C.1    Small, P.N.2    Elian, N.3
  • 19
    • 0031629719 scopus 로고    scopus 로고
    • Reduction of implant loading using a modified centric occlusal anatomy
    • Weinberg LA. Reduction of implant loading using a modified centric occlusal anatomy. Int J Prosthodont. 1998;11:55-69.
    • (1998) J Prosthodont , vol.11 , pp. 55-69
    • Weinberg, L.A.1
  • 20
    • 0027829254 scopus 로고
    • Biomechanical concerns with fixed partial dentures involving implants
    • English CE. Biomechanical concerns with fixed partial dentures involving implants. Implant Dent. 1993;2:221-242.
    • (1993) Implant Dent , vol.2 , pp. 221-242
    • English, C.E.1
  • 22
    • 0029262468 scopus 로고
    • Brånemark single tooth implants: A preliminary report of 76 implants
    • Haas R, Mensdorff-Pouilly N, Mailath G, et al. Brånemark single tooth implants: A preliminary report of 76 implants. J Prosthet Dent. 1995;73:274-279.
    • (1995) J Prosthet Dent , vol.73 , pp. 274-279
    • Haas, R.1    Mensdorff-Pouilly, N.2    Mailath, G.3
  • 23
    • 84856424459 scopus 로고    scopus 로고
    • Preload evaluation of different screws in external hexagon joint
    • Assunção WG, Delben JA, Tabata LF, et al. Preload evaluation of different screws in external hexagon joint. Implant Dent. 2012;21:46-50.
    • (2012) Implant Dent , vol.21 , pp. 46-50
    • Assunção, W.G.1    Delben, J.A.2    Tabata, L.F.3
  • 24
    • 40749140675 scopus 로고    scopus 로고
    • Preload and torque removal evaluation of three different abutment screws for single standing implant restorations
    • Stüker RA, Teixeira ER, Beck JC, et al. Preload and torque removal evaluation of three different abutment screws for single standing implant restorations. J Appl Oral Sci. 2008;16:55-58.
    • (2008) J Appl Oral Sci , vol.16 , pp. 55-58
    • Stüker, R.A.1    Teixeira, E.R.2    Beck, J.C.3
  • 25
    • 84858075685 scopus 로고    scopus 로고
    • Torque removal evaluation of prosthetic screws after tightening and loosening cycles: An in vitro study
    • Cardoso M, Torres MF, Lourenço EJ, et al. Torque removal evaluation of prosthetic screws after tightening and loosening cycles: an in vitro study. Clin Oral Implants Res. 2012;23:475-480.
    • (2012) Clin Oral Implants Res , vol.23 , pp. 475-480
    • Cardoso, M.1    Torres, M.F.2    Lourenço, E.J.3
  • 26
    • 0028451094 scopus 로고
    • Tightening characteristics for screw joints in osseointegrated dental implants
    • Burguete RI, Johns RB, King T, et al. Tightening characteristics for screw joints in osseointegrated dental implants. J Prosthet Dent. 1994;71:592-599.
    • (1994) J Prosthet Dent , vol.71 , pp. 592-599
    • Burguete, R.I.1    Johns, R.B.2    King, T.3
  • 27
    • 0029377054 scopus 로고
    • Elongation and preload stress in dental implant abutment screws
    • Haack JE, Sakaguchi RL, Sun T, et al. Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants. 1995;10:529-536.
    • (1995) J Oral Maxillofac Implants , vol.10 , pp. 529-536
    • Haack, J.E.1    Sakaguchi, R.L.2    Sun, T.3
  • 28
    • 84860888472 scopus 로고    scopus 로고
    • The effect of repeated torque in small diameter implants with machined and premachined abutments
    • Saboury A, Neshandar Asli H, Vaziri S. The effect of repeated torque in small diameter implants with machined and premachined abutments. Clin Implant Dent Relat Res. 2012;14(suppl 1):e224-e230.
    • (2012) Clin Implant Dent Relat Res , vol.14 , Issue.SUPPL. 1
    • Saboury, A.1    Neshandar Asli, H.2    Vaziri, S.3
  • 29
    • 80053345427 scopus 로고    scopus 로고
    • Photoelastic stress analysis of external versus internal implant-abutment connections
    • Asvanund P, Morgano SM. Photoelastic stress analysis of external versus internal implant-abutment connections. J Prosthet Dent. 2011;106:266-271.
    • (2011) J Prosthet Dent , vol.106 , pp. 266-271
    • Asvanund, P.1    Morgano, S.M.2
  • 30
    • 84863584384 scopus 로고    scopus 로고
    • Screw loosening with interchangeable abutments in internally connected implants after cyclic loading
    • Kim SK, Koak JY, Heo SJ, et al. Screw loosening with interchangeable abutments in internally connected implants after cyclic loading. Int J Oral Maxillofac Implants. 2012;27:42-47.
    • (2012) J Oral Maxillofac Implants , vol.27 , pp. 42-47
    • Kim, S.K.1    Koak, J.Y.2    Heo, S.J.3
  • 31
    • 0027655334 scopus 로고
    • Torque required to loosen single-tooth implant abutment screws before and after simulated function
    • Breeding LC, Dixon DL, Nelson EW, et al. Torque required to loosen single-tooth implant abutment screws before and after simulated function. Int J Prosthodont. 1993;6:435-439.
    • (1993) J Prosthodont , vol.6 , pp. 435-439
    • Breeding, L.C.1    Dixon, D.L.2    Nelson, E.W.3
  • 32
    • 0029377916 scopus 로고
    • Comparison of screw loosening, rotation, and deflection among three implant designs
    • Dixon DL, Breeding LC, Sadler JP, et al. Comparison of screw loosening, rotation, and deflection among three implant designs. J Prosthet Dent. 1995; 74:270-278.
    • (1995) J Prosthet Dent , vol.74 , pp. 270-278
    • Dixon, D.L.1    Breeding, L.C.2    Sadler, J.P.3
  • 33
    • 0034242686 scopus 로고    scopus 로고
    • Effect of repeated closures on opening torque values in seven abutment-implant systems
    • Weiss EI, Kozak D, Gross MD. Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent. 2000;84:194-199.
    • (2000) J Prosthet Dent , vol.84 , pp. 194-199
    • Weiss, E.I.1    Kozak, D.2    Gross, M.D.3
  • 34
    • 0033192526 scopus 로고    scopus 로고
    • Effect of washers on reverse torque displacement of dental implant gold retaining screws
    • Korioth TWP, Cardoso AC, Versluis A. Effect of washers on reverse torque displacement of dental implant gold retaining screws. J Prosthet Dent. 2001; 82:312-316.
    • (2001) J Prosthet Dent , vol.82 , pp. 312-316
    • Korioth, T.W.P.1    Cardoso, A.C.2    Versluis, A.3
  • 35
    • 1342279629 scopus 로고    scopus 로고
    • Preload loss in gold prosthesis-retaining screws as a function of time
    • Cantwell A, Hobkirk JA. Preload loss in gold prosthesis-retaining screws as a function of time. Int J Oral Maxillofac Implants. 2004;19:124-132.
    • (2004) J Oral Maxillofac Implants , vol.19 , pp. 124-132
    • Cantwell, A.1    Hobkirk, J.A.2
  • 36
    • 0026167259 scopus 로고
    • Mechanical aspects of a Brånemark implant connected to a natural tooth: An in vitro study
    • Rangert B, Gunne J, Sullivan DY. Mechanical aspects of a Brånemark implant connected to a natural tooth: An in vitro study. Int J Oral Maxillofac Implants. 1991;6:177-186.
    • (1991) J Oral Maxillofac Implants , vol.6 , pp. 177-186
    • Rangert, B.1    Gunne, J.2    Sullivan, D.Y.3
  • 37
    • 84872040192 scopus 로고    scopus 로고
    • Effects of different abutment connection designs of the stress distribution around five different implants: A 3-dimensional finite element analysis
    • Balik A, Karatas MO, Keskin H. Effects of different abutment connection designs of the stress distribution around five different implants: A 3-dimensional finite element analysis. J Oral Implantol. 2012; 38:491-496.
    • (2012) J Oral Implantol , vol.38 , pp. 491-496
    • Balik, A.1    Karatas, M.O.2    Keskin, H.3
  • 38
    • 1942456934 scopus 로고    scopus 로고
    • Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system
    • Khraisat A, Hashimoto A, Nomura S, et al. Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system. J Prosthet Dent. 2004;91:326-334.
    • (2004) J Prosthet Dent , vol.91 , pp. 326-334
    • Khraisat, A.1    Hashimoto, A.2    Nomura, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.