메뉴 건너뛰기




Volumn 23, Issue 4, 2012, Pages 475-480

Torque removal evaluation of prosthetic screws after tightening and loosening cycles: An in vitro study

Author keywords

External hex; Implant retained prostheses; Prosthetic screws; Torque

Indexed keywords

ARTICLE; BONE SCREW; DENTAL PROCEDURE; DENTURE; DEVICE REMOVAL; IN VITRO STUDY; MATERIALS TESTING; MECHANICAL STRESS; NONPARAMETRIC TEST; STATISTICAL MODEL; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TORQUE;

EID: 84858075685     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2011.02165.x     Document Type: Article
Times cited : (42)

References (30)
  • 2
    • 0030098964 scopus 로고    scopus 로고
    • The effect of implant/abutment hexagonal misfit on screw joint stability
    • Binon, P.P. (1996) The effect of implant/abutment hexagonal misfit on screw joint stability. The International Journal of Prosthodontics9: 149-160.
    • (1996) The International Journal of Prosthodontics , vol.9 , pp. 149-160
    • Binon, P.P.1
  • 5
    • 33646240845 scopus 로고    scopus 로고
    • Preloads generated with repeated tightening in three types of screws used in dental implants assemblies
    • Byrne, D., Jacobs, S., O'Connell, B., Houston, F. & Claffey, N. (2006) Preloads generated with repeated tightening in three types of screws used in dental implants assemblies. Journal of Prosthodontics15: 164-171.
    • (2006) Journal of Prosthodontics , vol.15 , pp. 164-171
    • Byrne, D.1    Jacobs, S.2    O'Connell, B.3    Houston, F.4    Claffey, N.5
  • 7
    • 65649137671 scopus 로고    scopus 로고
    • Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections
    • an in vitro study.
    • Coppedê, R.A., de Mattos, Mda.G., Rodrigues, R.C. & Ribeiro, R.F. (2009) Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study. Clinical Oral Implants Research20: 624-632.
    • (2009) Clinical Oral Implants Research , vol.20 , pp. 624-632
    • Coppedê, R.A.1    de Mattos, M.2    Rodrigues, R.C.3    Ribeiro, R.F.4
  • 8
    • 50349090311 scopus 로고    scopus 로고
    • Probabilistic analysis of preload in the abutment screw of a dental implant complex
    • Guda, T., Ross, T.A., Lang, L.A. & Millwater, H.R. (2008) Probabilistic analysis of preload in the abutment screw of a dental implant complex. Journal of Prosthetic Dentistry100: 183-193.
    • (2008) Journal of Prosthetic Dentistry , vol.100 , pp. 183-193
    • Guda, T.1    Ross, T.A.2    Lang, L.A.3    Millwater, H.R.4
  • 12
    • 33746626004 scopus 로고    scopus 로고
    • Implant treatment in the edentulous maxillae
    • a 15-year follow-up study on 76 consecutive patients provided with fixed prostheses.
    • Jemt, T. & Johansson, J. (2006) Implant treatment in the edentulous maxillae: a 15-year follow-up study on 76 consecutive patients provided with fixed prostheses. Clinical Implant Dentistry & Related Research8: 61-69.
    • (2006) Clinical Implant Dentistry & Related Research , vol.8 , pp. 61-69
    • Jemt, T.1    Johansson, J.2
  • 14
    • 9644288015 scopus 로고    scopus 로고
    • Abutment screw loosening and bending resistance of external hexagon implant system after lateral cyclic loading
    • Khraisat, A., Abu-Hammad, O., Dar-Odeh, N. & Al-Kayed, A.M. (2004) Abutment screw loosening and bending resistance of external hexagon implant system after lateral cyclic loading. Clinical Implant Dentistry & Related Research6: 157-164.
    • (2004) Clinical Implant Dentistry & Related Research , vol.6 , pp. 157-164
    • Khraisat, A.1    Abu-Hammad, O.2    Dar-Odeh, N.3    Al-Kayed, A.M.4
  • 16
    • 35948932580 scopus 로고    scopus 로고
    • Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years
    • Kreissl, M.E., Gerds, T., Muche, R., Heydecke, G. & Strub, J.R. (2007) Technical complications of implant-supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clinical Oral Implants Research18: 720-726.
    • (2007) Clinical Oral Implants Research , vol.18 , pp. 720-726
    • Kreissl, M.E.1    Gerds, T.2    Muche, R.3    Heydecke, G.4    Strub, J.R.5
  • 18
    • 33645347993 scopus 로고    scopus 로고
    • In vitro differences of stress concentrations for internal and external hex implant-abutment connections
    • a short communication.
    • Maeda, Y., Satoh, T. & Sogo, M. (2006) In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication. Journal of Oral Rehabilitation33: 75-78.
    • (2006) Journal of Oral Rehabilitation , vol.33 , pp. 75-78
    • Maeda, Y.1    Satoh, T.2    Sogo, M.3
  • 19
    • 0035406731 scopus 로고    scopus 로고
    • Implant abutment screw rotations and preloads for four different screw materials and surfaces
    • Martin, W.C., Woody, R.D., Miller, B.H. & Miller, A.W. (2001) Implant abutment screw rotations and preloads for four different screw materials and surfaces. Journal of Prosthetic Dentistry86: 24-32.
    • (2001) Journal of Prosthetic Dentistry , vol.86 , pp. 24-32
    • Martin, W.C.1    Woody, R.D.2    Miller, B.H.3    Miller, A.W.4
  • 20
  • 22
    • 34250625230 scopus 로고    scopus 로고
    • Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs)
    • Pjetursson, B.E., Brägger, U., Lang, N.P. & Zwahlen, M. (2007) Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs). Clinical Oral Implants Research18: 97-113.
    • (2007) Clinical Oral Implants Research , vol.18 , pp. 97-113
    • Pjetursson, B.E.1    Brägger, U.2    Lang, N.P.3    Zwahlen, M.4
  • 23
    • 12244275012 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. I. Implant-supported FPDs
    • Pjetursson, B.E., Tan, K., Lang, N.P., Brägger, U., Egger, M. & Zwahlen, M. (2004) A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. I. Implant-supported FPDs. Clinical Oral Implants Research15: 625-642.
    • (2004) Clinical Oral Implants Research , vol.15 , pp. 625-642
    • Pjetursson, B.E.1    Tan, K.2    Lang, N.P.3    Brägger, U.4    Egger, M.5    Zwahlen, M.6
  • 25
    • 40749140675 scopus 로고    scopus 로고
    • Preload and torque removal evaluation of three different abutment screws for single standing implant restorations
    • Stüker, R.A., Teixeira, E.R., Beck, J.C. & da Costa, N.P. (2008) Preload and torque removal evaluation of three different abutment screws for single standing implant restorations. Journal of Applied Oral Science16: 55-58.
    • (2008) Journal of Applied Oral Science , vol.16 , pp. 55-58
    • Stüker, R.A.1    Teixeira, E.R.2    Beck, J.C.3    da Costa, N.P.4
  • 27
    • 68949159617 scopus 로고    scopus 로고
    • Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants
    • Tsuge, T. & Hagiwara, Y. (2009) Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants. Dental Materials Journal28: 373-381.
    • (2009) Dental Materials Journal , vol.28 , pp. 373-381
    • Tsuge, T.1    Hagiwara, Y.2
  • 28
    • 0036673514 scopus 로고    scopus 로고
    • The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws
    • Tzenakis, G.K., Nagy, W.W., Fournelle, R.A. & Dhuru, V.B. (2002) The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws. Journal of Prosthetic Dentistry88: 183-191.
    • (2002) Journal of Prosthetic Dentistry , vol.88 , pp. 183-191
    • Tzenakis, G.K.1    Nagy, W.W.2    Fournelle, R.A.3    Dhuru, V.B.4
  • 30
    • 0034242686 scopus 로고    scopus 로고
    • Effect of repeated closures on opening torque values in seven abutment-implant systems
    • Weiss, E.I., Kozak, D. & Gross, M.D. (2000) Effect of repeated closures on opening torque values in seven abutment-implant systems. Journal of Prosthetic Dentistry84: 194-199.
    • (2000) Journal of Prosthetic Dentistry , vol.84 , pp. 194-199
    • Weiss, E.I.1    Kozak, D.2    Gross, M.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.