-
1
-
-
0036632491
-
Twenty years of progress in implant prosthodontics
-
Taylor TD, Agar JR. Twenty years of progress in implant prosthodontics. J Prosthet Dent 2002;88:89-95.
-
(2002)
J Prosthet Dent
, vol.88
, pp. 89-95
-
-
Taylor, T.D.1
Agar, J.R.2
-
3
-
-
0031301642
-
Fit of implant frameworks fabricated by different techniques
-
Riedy SJ, Lang BR, Lang BE. Fit of implant frameworks fabricated by different techniques. J Prosthet Dent 1997;78:596-604.
-
(1997)
J Prosthet Dent
, vol.78
, pp. 596-604
-
-
Riedy, S.J.1
Lang, B.R.2
Lang, B.E.3
-
5
-
-
0028522448
-
A new method to routinely achieve passive fit of ceramometal prostheses over Brånemark osseointegrated implants: A two-year report
-
Aparicio C. A new method to routinely achieve passive fit of ceramometal prostheses over Brånemark osseointegrated implants: a two-year report. Int J Periodontics Restorative Dent 1994;14:405-419.
-
(1994)
Int J Periodontics Restorative Dent
, vol.14
, pp. 405-419
-
-
Aparicio, C.1
-
6
-
-
0034154709
-
Analysis of stress distribution in a screw-retained implant prosthesis
-
Watanabe F, Uno I, Hata Y, Neuendorff G, Kirsch A. Analysis of stress distribution in a screw-retained implant prosthesis. Int J Oral Maxillofac Implants 2000;15:209-218.
-
(2000)
Int J Oral Maxillofac Implants
, vol.15
, pp. 209-218
-
-
Watanabe, F.1
Uno, I.2
Hata, Y.3
Neuendorff, G.4
Kirsch, A.5
-
8
-
-
0028390316
-
Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
-
Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9:169-178.
-
(1994)
Int J Oral Maxillofac Implants
, vol.9
, pp. 169-178
-
-
Kallus, T.1
Bessing, C.2
-
10
-
-
0028451094
-
Tightening characteristics for screwed joints in osseointegrated dental implants
-
Burguete RL, Johns RB, King T, Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosthet Dent 1994;71:592-599.
-
(1994)
J Prosthet Dent
, vol.71
, pp. 592-599
-
-
Burguete, R.L.1
Johns, R.B.2
King, T.3
Patterson, E.A.4
-
12
-
-
0027829234
-
Nonlinear finite element contact analysis of dental implant components
-
Sakaguchi RL, Borgersen SE. Nonlinear finite element contact analysis of dental implant components. Int J Oral Maxillofac Implants 1993;8:655-661.
-
(1993)
Int J Oral Maxillofac Implants
, vol.8
, pp. 655-661
-
-
Sakaguchi, R.L.1
Borgersen, S.E.2
-
13
-
-
0030098964
-
The effect of implant/abutment hexagonal misfit on screw joint stability
-
Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996;9:149-160.
-
(1996)
Int J Prosthodont
, vol.9
, pp. 149-160
-
-
Binon, P.P.1
-
14
-
-
0030275656
-
The effect of eliminating implant/abutment rotational misfit on screw joint stability
-
Binon PP, McHugh MJ. The effect of eliminating implant/abutment rotational misfit on screw joint stability. Int J Prosthodont 1996;9:511-519.
-
(1996)
Int J Prosthodont
, vol.9
, pp. 511-519
-
-
Binon, P.P.1
McHugh, M.J.2
-
15
-
-
0036632491
-
Twenty years of progress in implant prosthodontics
-
Taylor TD, Agar JR. Twenty years of progress in implant prosthodontics. J Prosthet Dent 2002;88:89-95.
-
(2002)
J Prosthet Dent
, vol.88
, pp. 89-95
-
-
Taylor, T.D.1
Agar, J.R.2
-
16
-
-
0020823258
-
Osseointegration and its experimental background
-
Brånemark PI. Osseointegration and its experimental background. J Prosthet Dent 1983;50:399-410.
-
(1983)
J Prosthet Dent
, vol.50
, pp. 399-410
-
-
Brånemark, P.I.1
-
17
-
-
0022308868
-
Comparison of accuracy of multiunit one-piece castings
-
Schiffleger BE, Ziebert GJ, Dhuru VB, Brantley WA, Sigaroudi K. Comparison of accuracy of multiunit one-piece castings. J Prosthet Dent 1985;54:770-776.
-
(1985)
J Prosthet Dent
, vol.54
, pp. 770-776
-
-
Schiffleger, B.E.1
Ziebert, G.J.2
Dhuru, V.B.3
Brantley, W.A.4
Sigaroudi, K.5
-
18
-
-
0033113639
-
Characterization of the interface between prefabricated gold copings and cast dental alloy in implant restorations
-
Carotenuto G, Palumbo M, Zarone F, Nicolais L. Characterization of the interface between prefabricated gold copings and cast dental alloy in implant restorations. Clin Oral Implants Res 1999;10:131-138.
-
(1999)
Clin Oral Implants Res
, vol.10
, pp. 131-138
-
-
Carotenuto, G.1
Palumbo, M.2
Zarone, F.3
Nicolais, L.4
-
19
-
-
1342271919
-
Preload comparison between as-received and cast-to implant cylinders
-
Carr AB, Brunski JB, Hurley E. Preload comparison between as-received and cast-to implant cylinders. J Dent Research 1993;72:190-195.
-
(1993)
J Dent Research
, vol.72
, pp. 190-195
-
-
Carr, A.B.1
Brunski, J.B.2
Hurley, E.3
-
20
-
-
0032018774
-
Description and evaluation of a simplified method to achieve passive fit between cast titanium frameworks and implants
-
Helldén LB, Dérand T. Description and evaluation of a simplified method to achieve passive fit between cast titanium frameworks and implants. Int J Oral Maxillofac Implants 1998;13:190-196.
-
(1998)
Int J Oral Maxillofac Implants
, vol.13
, pp. 190-196
-
-
Helldén, L.B.1
Dérand, T.2
|