메뉴 건너뛰기




Volumn 21, Issue 1, 2012, Pages 46-50

Preload evaluation of different screws in external hexagon joint

Author keywords

dental implants; implantsupported dental prosthesis; prosthesis failure; torque

Indexed keywords

BIOMATERIAL; GOLD ALLOY; TITANIUM; TITANIUM NITRIDE;

EID: 84856424459     PISSN: 10566163     EISSN: None     Source Type: Journal    
DOI: 10.1097/ID.0b013e31823fcbce     Document Type: Article
Times cited : (38)

References (26)
  • 1
    • 7044249030 scopus 로고    scopus 로고
    • Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants
    • DOI 10.1016/j.jbiomech.2004.03.006, PII S0021929004001423
    • Bozkaya D, MüftüS. Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants. J Biomech. 2005;38:87-97. (Pubitemid 39424982)
    • (2005) Journal of Biomechanics , vol.38 , Issue.1 , pp. 87-97
    • Bozkaya, D.1    Muftu, S.2
  • 3
    • 37849054339 scopus 로고    scopus 로고
    • A systematic review of the 5-year survival and complication rates of implantsupported single crowns
    • Jung RE, Pjetursson BE, Glauser R, et al. A systematic review of the 5-year survival and complication rates of implantsupported single crowns. Clin Oral Impl Res. 2008;19:119-130.
    • (2008) Clin Oral Impl Res. , vol.19 , pp. 119-130
    • Jung, R.E.1    Pjetursson, B.E.2    Glauser, R.3
  • 4
    • 35948932580 scopus 로고    scopus 로고
    • Technical complications of implantsupported fixed partial dentures in partially edentulous cases after an average observation period of 5 years
    • Kreissl ME, Gerds T, Muche R, et al. Technical complications of implantsupported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clin Oral Impl Res. 2007;18:720-726.
    • (2007) Clin Oral Impl Res. , vol.18 , pp. 720-726
    • Kreissl, M.E.1    Gerds, T.2    Muche, R.3
  • 5
    • 50349090311 scopus 로고    scopus 로고
    • Probabilistic analysis of preload in the abutment screw of a dental implant complex
    • Guda T, Ross TA, Lang LA, et al. Probabilistic analysis of preload in the abutment screw of a dental implant complex. J Prosthet Dent. 2008;100:183-193.
    • (2008) J Prosthet Dent. , vol.100 , pp. 183-193
    • Guda, T.1    Ross, T.A.2    Lang, L.A.3
  • 6
    • 0025657547 scopus 로고
    • 3-year follow up study of early single implant restorations ad modum Brånemark
    • Jemt T, Lekholm U, Grondahl K. 3-year follow up study of early single implant restorations ad modum Brånemark. Int J Periodontics Restorative Dent. 1990; 10:340-349.
    • (1990) Int J Periodontics Restorative Dent. , vol.10 , pp. 340-349
    • Jemt, T.1    Lekholm, U.2    Grondahl, K.3
  • 7
    • 12244275012 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years: I. Implant-supported FPDs
    • DOI 10.1111/j.1600-0501.2004.01117.x
    • Pjetursson BE, Tan K, Lang NP, et al. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. I. Implant-supported FPDs. Clin Oral Impl Res. 2004;15:625-642. (Pubitemid 40115751)
    • (2004) Clinical Oral Implants Research , vol.15 , Issue.6 , pp. 625-642
    • Pjetursson, B.E.1    Tan, K.2    Lang, N.P.3    Bragger, U.4    Egger, M.5    Zwahlen, M.6
  • 8
    • 0034242686 scopus 로고    scopus 로고
    • Effect of repeated closures on opening torque values in seven abutment-implant systems
    • Weiss EI, Kozak D, Gross MD. Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent. 2000;84:194-199.
    • (2000) J Prosthet Dent. , vol.84 , pp. 194-199
    • Weiss, E.I.1    Kozak, D.2    Gross, M.D.3
  • 9
    • 33646240845 scopus 로고    scopus 로고
    • Preloads generated with repeated tightening in three types of screws used in dental implant assemblies
    • DOI 10.1111/j.1532-849X.2006.00096.x
    • Byrne D, Jacobs S, O'Connell B, et al. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J Prosthodont. 2006;15:164-171. (Pubitemid 43653911)
    • (2006) Journal of Prosthodontics , vol.15 , Issue.3 , pp. 164-171
    • Byrne, D.1    Jacobs, S.2    O'Connell, B.3    Houston, F.4    Claffey, N.5
  • 10
    • 0035406731 scopus 로고    scopus 로고
    • Implant abutment screw rotations and preloads for four different screw materials and surfaces
    • DOI 10.1067/mpr.2001.116230
    • Martin WC, Woody RD, Miller BH, et al. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent. 2001; 86:24-32. (Pubitemid 33601396)
    • (2001) Journal of Prosthetic Dentistry , vol.86 , Issue.1 , pp. 24-32
    • Martin, W.C.1    Woody, R.D.2    Miller, B.H.3    Miller, A.W.4
  • 11
    • 0029383396 scopus 로고
    • Geometric comparison of five interchangeable implant prosthetic retaining screws
    • Jaarda MJ, Razzoog ME, Gratton DG. Geometric comparison of five interchangeable implant prosthetic retaining screws. J Prosthet Dent. 1995;74:373-379.
    • (1995) J Prosthet Dent. , vol.74 , pp. 373-379
    • Jaarda, M.J.1    Razzoog, M.E.2    Gratton, D.G.3
  • 12
    • 0346219409 scopus 로고    scopus 로고
    • Finite element analysis to determine implant preload
    • DOI 10.1016/j.prosdent.2003.09.012
    • Lang LA, Kang B, Wang RF, et al. Finite element analysis to determine implant preload. J Prosthet Dent. 2003;90: 539-546. (Pubitemid 37532504)
    • (2003) Journal of Prosthetic Dentistry , vol.90 , Issue.6 , pp. 539-546
    • Lang, L.A.1    Kang, B.2    Wang, R.-F.3    Lang, B.R.4
  • 13
    • 33645959184 scopus 로고    scopus 로고
    • Effect of casting procedures on screw loosening in UCLA-type abutments
    • DOI 10.1111/j.1532-849X.2006.00078.x
    • Kano SC, Binon P, Bonfante G, et al. Effect of casting procedures on screw loosening in UCLA-type abutments. J Prosthodont. 2006;15:77-81. (Pubitemid 43597971)
    • (2006) Journal of Prosthodontics , vol.15 , Issue.2 , pp. 77-81
    • Kano, S.C.1    Binon, P.2    Bonfante, G.3    Curtis, D.A.4
  • 15
    • 33644878581 scopus 로고    scopus 로고
    • Analysis of changes in implant screws subject to occlusal loading: A preliminary analysis
    • Yousef H, Luke A, Ricci J, et al. Analysis of changes in implant screws subject to occlusal loading: A preliminary analysis. Implant Dent. 2005;14:378-382.
    • (2005) Implant Dent. , vol.14 , pp. 378-382
    • Yousef, H.1    Luke, A.2    Ricci, J.3
  • 16
    • 0036673514 scopus 로고    scopus 로고
    • The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws
    • DOI 10.1067/mpr.2002.127604
    • Tzenakis GK, Nagy WW, Fournelle RA, et al. The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws. J Prosthet Dent. 2002;88:183-191. (Pubitemid 40433881)
    • (2002) Journal of Prosthetic Dentistry , vol.88 , Issue.2 , pp. 183-191
    • Tzenakis, G.K.1    Nagy, W.W.2    Fournelle, R.A.3    Dhuru, V.B.4
  • 18
    • 85047681494 scopus 로고    scopus 로고
    • Micromotion and dynamic fatigue properties of the dental implant-abutment interface
    • DOI 10.107/mpr.2001.112796
    • Gratton DG, Aquilino SA, Stanford CM. Micromotion and dynamic fatigue properties of the dental implant-abutment interface. J Prosthet Dent. 2001;85: 47-52. (Pubitemid 33660929)
    • (2001) Journal of Prosthetic Dentistry , vol.85 , Issue.1 , pp. 47-52
    • Gratton, D.G.1    Aquilino, S.A.2    Stanford, C.M.3
  • 20
    • 1942456934 scopus 로고    scopus 로고
    • Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system
    • DOI 10.1016/j.prosdent.2004.01.001, PII S0022391304000022
    • Khraisat A, Hashimoto A, Nomura S, et al. Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system. J Prosthet Dent. 2004;91:326-334. (Pubitemid 38515792)
    • (2004) Journal of Prosthetic Dentistry , vol.91 , Issue.4 , pp. 326-334
    • Khraisat, A.1    Hashimoto, A.2    Nomura, S.3    Miyakawa, O.4
  • 21
    • 0029377916 scopus 로고
    • Comparison of screw loosening, rotation, and deflection among three implant designs
    • Dixon DL, Breeding LC, Sadler JP, et al. Comparison of screw loosening, rotation, and deflection among three implant designs. J Prosthet Dent. 1995;74:270-278.
    • (1995) J Prosthet Dent. , vol.74 , pp. 270-278
    • Dixon, D.L.1    Breeding, L.C.2    Sadler, J.P.3
  • 22
    • 0026829920 scopus 로고
    • Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants
    • Patterson EA, Johns RB. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants. 1992;7:26-33.
    • (1992) Int J Oral Maxillofac Implants. , vol.7 , pp. 26-33
    • Patterson, E.A.1    Johns, R.B.2
  • 23
    • 84856488877 scopus 로고    scopus 로고
    • Implants and implant restorative components
    • Ames, IA: Blackwell Publications;
    • Drago C. Implants and implant restorative components. Implant Restorations-A Step-by-Step Guide. Ames, IA: Blackwell Publications; 2007: 17-54.
    • (2007) Implant Restorations-A Step-by-Step Guide , pp. 17-54
    • Drago, C.1
  • 24
    • 70349194587 scopus 로고    scopus 로고
    • Effect of misfit on preload maintenance of retention screws of implant-supported prostheses
    • Assunção WG, dos Santos PH, Delben JA, et al. Effect of misfit on preload maintenance of retention screws of implant-supported prostheses. J Mater Eng Perform. 2009;18:935-938.
    • (2009) J Mater Eng Perform. , vol.18 , pp. 935-938
    • Assunção, W.G.1    Dos Santos, P.H.2    Delben, J.A.3
  • 26
    • 0026921977 scopus 로고
    • Loads and designs of screw joints for single crowns supported by osseointegrated implants
    • Jorneas L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implant. 1992;7:353-359.
    • (1992) Int J Oral Maxillofac Implant. , vol.7 , pp. 353-359
    • Jorneas, L.1    Jemt, T.2    Carlsson, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.