Volumn 84, Issue 2, 2000, Pages 194-199

Effect of repeated closures on opening torque values in seven abutment-implant systems

Author keywords

[No Author keywords available]

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; COMPARATIVE STUDY; DENTAL CARE; DENTAL TECHNOLOGY; DENTURE; FRICTION; HUMAN; INSTRUMENTATION; METHODOLOGY; NONPARAMETRIC TEST; STATISTICAL MODEL; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TORQUE;

EID: 0034242686     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1067/mpr.2000.108069     Document Type: Article
Times cited : (100)

References (14)
  • 1
    • 0022666201 scopus 로고
    • Modified single and short-span restorations supported by osseointegrated fixtures in the partially edentulous jaw
    • Jemt T. Modified single and short-span restorations supported by osseointegrated fixtures in the partially edentulous jaw. J Prosthet Dent 1986;55:243-7.
    • (1986) J Prosthet Dent , vol.55 , pp. 243-247
    • Jemt, T.1
  • 2
    • 0026218667 scopus 로고
    • Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: Astudy of treatment from the time of prosthesis placement to the first annual checkup
    • Jemt T. Failures and complications in 391 consecutively inserted fixed prostheses supported by Brånemark implants in edentulous jaws: astudy of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants 1991;6:270-6.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 270-276
    • Jemt, T.1
  • 3
    • 0026125062 scopus 로고
    • Osseointegrated implants for single tooth replacement: A 1-year report from a multicenter prospective study
    • Jemt T, Laney WR, Harris D, Henry PJ, Krogh PH, Polizzi G, et al. Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study. Int J Oral Maxillofac Implants 1991;6:29-36.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 29-36
    • Jemt, T.1    Laney, W.R.2    Harris, D.3    Henry, P.J.4    Krogh, P.H.5    Polizzi, G.6
  • 4
    • 0027650622 scopus 로고
    • A 3-year follow-up study on single implant treatment
    • Jemt T, Pettersson P. A 3-year follow-up study on single implant treatment. J Dent 1993;21:203-8.
    • (1993) J Dent , vol.21 , pp. 203-208
    • Jemt, T.1    Pettersson, P.2
  • 5
    • 0026810954 scopus 로고
    • A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism
    • Naert I, Quirynen M, van Steenberghe D, Darius P. A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992;67:236-45.
    • (1992) J Prosthet Dent , vol.67 , pp. 236-245
    • Naert, I.1    Quirynen, M.2    Van Steenberghe, D.3    Darius, P.4
  • 6
    • 0028390316 scopus 로고
    • Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
    • Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 1994;9:169-78.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 169-178
    • Kallus, T.1    Bessing, C.2
  • 7
    • 0039829366 scopus 로고
    • The role of screws in implant systems
    • Binon P. The role of screws in implant systems. Int J Oral Maxillofac Implants 1994;9(suppl):48-63.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 48-63
    • Binon, P.1
  • 8
    • 0028451094 scopus 로고
    • Tightening characteristics for screwed joints in osseointegrated implants
    • Burguete RL, Johns RB, King T, Patterson EA. Tightening characteristics for screwed joints in osseointegrated implants J Prosthet Dent 1994;71:592-9.
    • (1994) J Prosthet Dent , vol.71 , pp. 592-599
    • Burguete, R.L.1    Johns, R.B.2    King, T.3    Patterson, E.A.4
  • 10
    • 0030098964 scopus 로고    scopus 로고
    • The effect of implant/abutment hexagonal misfit on screw joint stability
    • Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996;9:149-60.
    • (1996) Int J Prosthodont , vol.9 , pp. 149-160
    • Binon, P.P.1
  • 11
    • 0033124057 scopus 로고    scopus 로고
    • Manual closing torque in five implant abutment systems: An in vitro comparative study
    • Gross M, Kozak D, Laufer BZ, Weiss B. Manual closing torque in five implant abutment systems: an in vitro comparative study. J Prosthet Dent 1999;81:574-88.
    • (1999) J Prosthet Dent , vol.81 , pp. 574-588
    • Gross, M.1    Kozak, D.2    Laufer, B.Z.3    Weiss, B.4
  • 12
    • 0026921977 scopus 로고
    • Loads and designs of screw joints for single crowns supported by osseointegrated implants
    • Jorneus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 1992;7:353-9.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 353-359
    • Jorneus, L.1    Jemt, T.2    Carlsson, L.3
  • 13
    • 0032617145 scopus 로고    scopus 로고
    • Micro leakage at the abutment-implant interface of osseointegrated implants: A comparative study
    • Gross M, Abramovich I, Weiss EI. Micro leakage at the abutment-implant interface of osseointegrated implants: a comparative study. Int J Oral Maxillofac Implants 1999;14:94-100.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 94-100
    • Gross, M.1    Abramovich, I.2    Weiss, E.I.3
  • 14
    • 0029268937 scopus 로고
    • Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogues
    • Binon PP. Evaluation of machining accuracy and consistency of selected implants, standard abutments, and laboratory analogues. Int J Prosthodont 1995;2:162-78.
    • (1995) Int J Prosthodont , vol.2 , pp. 162-178
    • Binon, P.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.