메뉴 건너뛰기




Volumn 23, Issue 10, 2012, Pages 1181-1186

The effect of clockwise and counterclockwise twisting moments on abutment screw loosening

Author keywords

Abutment screw loosening; Dental implant; Internal hexagonal connection; Twisting moment

Indexed keywords

ARTICLE; DENTAL ABUTMENT; DENTAL PROCEDURE; DENTAL SURGERY; INSTRUMENTATION; MATERIALS TESTING; NONPARAMETRIC TEST; SCANNING ELECTRON MICROSCOPY; SURFACE PROPERTY; TOOTH IMPLANT; TOOTH PROSTHESIS; TORQUE;

EID: 84866485762     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2011.02282.x     Document Type: Article
Times cited : (22)

References (31)
  • 1
    • 16244400507 scopus 로고    scopus 로고
    • Finite element analyses of two antirotational designs of implant fixtures
    • Akour, S.N., Fayyad, M.A. & Nayfeh, J.F. (2005) Finite element analyses of two antirotational designs of implant fixtures. Implant Dentistry 14: 77-81.
    • (2005) Implant Dentistry , vol.14 , pp. 77-81
    • Akour, S.N.1    Fayyad, M.A.2    Nayfeh, J.F.3
  • 2
    • 0030098964 scopus 로고    scopus 로고
    • The effect of implant/abutment hexagonal misfit on screw joint stability
    • Binon, P.P. (1996) The effect of implant/abutment hexagonal misfit on screw joint stability. International Journal of Prosthodontics 9: 149-160.
    • (1996) International Journal of Prosthodontics , vol.9 , pp. 149-160
    • Binon, P.P.1
  • 3
    • 0030275656 scopus 로고    scopus 로고
    • The effect of eliminating implant/abutment rotational misfit on screw joint stability
    • Binon, P.P. & McHugh, M.J. (1996) The effect of eliminating implant/abutment rotational misfit on screw joint stability. International Journal of Prosthodontics 9: 511-519.
    • (1996) International Journal of Prosthodontics , vol.9 , pp. 511-519
    • Binon, P.P.1    McHugh, M.J.2
  • 4
    • 33646240845 scopus 로고    scopus 로고
    • Preloads generated with repeated tightening in three types of screws used in dental implant assemblies
    • Byrne, D., Jacobs, S., O'Connell, B., Houston, F. & Claffey, N. (2006) Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. Journal of Prosthodontics 15: 164-171.
    • (2006) Journal of Prosthodontics , vol.15 , pp. 164-171
    • Byrne, D.1    Jacobs, S.2    O'Connell, B.3    Houston, F.4    Claffey, N.5
  • 5
    • 65649137671 scopus 로고    scopus 로고
    • Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study
    • Coppede, A. Ricciardi, de Mattos Mda, G., Rodrigues, R.C. & Ribeiro, R.F. (2009) Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study. Clinical Oral Implants Research 20: 624-632.
    • (2009) Clinical Oral Implants Research , vol.20 , pp. 624-632
    • Coppede, A.R.1    de Mattos Mda, G.2    Rodrigues, R.C.3    Ribeiro, R.F.4
  • 10
    • 0027650622 scopus 로고
    • A 3-year follow-up study on single implant treatment
    • Jemt, T. & Pettersson, P. (1993) A 3-year follow-up study on single implant treatment. Journal of Dentistry 21: 203-208.
    • (1993) Journal of Dentistry , vol.21 , pp. 203-208
    • Jemt, T.1    Pettersson, P.2
  • 12
  • 13
    • 1942456934 scopus 로고    scopus 로고
    • Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system
    • Khraisat, A., Hashimoto, A., Nomura, S. & Miyakawa, O. (2004b) Effect of lateral cyclic loading on abutment screw loosening of an external hexagon implant system. Journal of Prosthetic Dentistry 91: 326-334.
    • (2004) Journal of Prosthetic Dentistry , vol.91 , pp. 326-334
    • Khraisat, A.1    Hashimoto, A.2    Nomura, S.3    Miyakawa, O.4
  • 15
    • 0026271048 scopus 로고
    • Restorative advantages of the coronally hexed implant
    • Lazzara, R.J. (1991) Restorative advantages of the coronally hexed implant. Compendium 12: 924.
    • (1991) Compendium , vol.12 , pp. 924
    • Lazzara, R.J.1
  • 17
    • 0002002656 scopus 로고
    • Jaw movements and forces during chewing and swallowing and their clinical significance
    • eds. In, Boston: John Wright.
    • Lundeen, H. C., Gibbs, C.H., eds. (1982) Jaw movements and forces during chewing and swallowing and their clinical significance. In: Advanced in Occlusion, 2-32. Boston: John Wright.
    • (1982) Advanced in Occlusion , pp. 2-32
    • Lundeen, H.C.1    Gibbs, C.H.2
  • 18
    • 33645347993 scopus 로고    scopus 로고
    • In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication
    • Maeda, Y., Satoh, T. & Sogo, M. (2006) In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication. Journal of Oral Rehabilitation 33: 75-78.
    • (2006) Journal of Oral Rehabilitation , vol.33 , pp. 75-78
    • Maeda, Y.1    Satoh, T.2    Sogo, M.3
  • 20
    • 0034218915 scopus 로고    scopus 로고
    • Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection
    • Merz, B.R., Hunenbart, S. & Belser, U.C. (2000) Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. International Journal of Oral & Maxillofacial Implants 15: 519-526.
    • (2000) International Journal of Oral & Maxillofacial Implants , vol.15 , pp. 519-526
    • Merz, B.R.1    Hunenbart, S.2    Belser, U.C.3
  • 21
    • 0033074393 scopus 로고    scopus 로고
    • Assessment of cold welding properties of the internal conical interface of two commercially available implant systems
    • Norton, M.R. (1999) Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. Journal of Prosthetic Dentistry 81: 159-166.
    • (1999) Journal of Prosthetic Dentistry , vol.81 , pp. 159-166
    • Norton, M.R.1
  • 22
    • 0036779584 scopus 로고    scopus 로고
    • Fatigue resistance of iti implant-abutment connectors - a comparison of the standard cone with a novel internally keyed design
    • Perriard, J., Wiskott, W.A., Mellal, A., Scherrer, S.S., Botsis, J. & Belser, U.C. (2002) Fatigue resistance of iti implant-abutment connectors - a comparison of the standard cone with a novel internally keyed design. Clinical Oral Implants Research 13: 542-549.
    • (2002) Clinical Oral Implants Research , vol.13 , pp. 542-549
    • Perriard, J.1    Wiskott, W.A.2    Mellal, A.3    Scherrer, S.S.4    Botsis, J.5    Belser, U.C.6
  • 23
    • 43149105399 scopus 로고    scopus 로고
    • Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system
    • Quek, H.C., Tan, K.B. & Nicholls, J.I. (2008) Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system. International Journal of Oral & Maxillofacial Implants 23: 253-262.
    • (2008) International Journal of Oral & Maxillofacial Implants , vol.23 , pp. 253-262
    • Quek, H.C.1    Tan, K.B.2    Nicholls, J.I.3
  • 24
    • 0034574104 scopus 로고    scopus 로고
    • Mechanical complications of dental implants
    • Schwarz, M.S. (2000) Mechanical complications of dental implants. Clinical Oral Implants Research 11(Suppl. 1): 156-158.
    • (2000) Clinical Oral Implants Research , vol.11 , Issue.SUPPL. 1 , pp. 156-158
    • Schwarz, M.S.1
  • 25
    • 0036357495 scopus 로고    scopus 로고
    • Relationship between implant preload and screw loosening on implant-supported prostheses
    • Siamos, G., Winkler, S. & Boberick, K.G. (2002) Relationship between implant preload and screw loosening on implant-supported prostheses. Journal of Oral Implantology 28: 67-73.
    • (2002) Journal of Oral Implantology , vol.28 , pp. 67-73
    • Siamos, G.1    Winkler, S.2    Boberick, K.G.3
  • 26
    • 55649083146 scopus 로고    scopus 로고
    • Implant-abutment interface design affects fatigue and fracture strength of implants
    • Steinebrunner, L., Wolfart, S., Ludwig, K. & Kern, M. (2008) Implant-abutment interface design affects fatigue and fracture strength of implants. Clinical Oral Implants Research 19: 1276-1284.
    • (2008) Clinical Oral Implants Research , vol.19 , pp. 1276-1284
    • Steinebrunner, L.1    Wolfart, S.2    Ludwig, K.3    Kern, M.4
  • 27
    • 7244237988 scopus 로고    scopus 로고
    • Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter
    • Tan, B.F., Tan, K.B. & Nicholls, J.I. (2004) Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter. International Journal of Oral & Maxillofacial Implants 19: 648-658.
    • (2004) International Journal of Oral & Maxillofacial Implants , vol.19 , pp. 648-658
    • Tan, B.F.1    Tan, K.B.2    Nicholls, J.I.3
  • 29
    • 68949159617 scopus 로고    scopus 로고
    • Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants
    • Tsuge, T. & Hagiwara, Y. (2009) Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants. Dental Materials Journal 28: 373-381.
    • (2009) Dental Materials Journal , vol.28 , pp. 373-381
    • Tsuge, T.1    Hagiwara, Y.2
  • 30
    • 0034242686 scopus 로고    scopus 로고
    • Effect of repeated closures on opening torque values in seven abutment-implant systems
    • Weiss, E.I., Kozak, D. & Gross, M.D. (2000) Effect of repeated closures on opening torque values in seven abutment-implant systems. Journal of Prosthetic Dentistry 84: 194-199.
    • (2000) Journal of Prosthetic Dentistry , vol.84 , pp. 194-199
    • Weiss, E.I.1    Kozak, D.2    Gross, M.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.