메뉴 건너뛰기




Volumn 38, Issue SUPPL. 1, 2012, Pages 491-496

Effects of different abutment connection designs on the stress distribution around five different implants: A 3- dimensional finite element analysis

Author keywords

Abutment connection; Finite element; Implant; Prosthetics; Strain distribution

Indexed keywords

ARTICLE; BIOMECHANICS; COMPARATIVE STUDY; COMPUTER SIMULATION; DENTAL ABUTMENT; DENTAL PROCEDURE; FINITE ELEMENT ANALYSIS; HUMAN; INSTRUMENTATION; MATERIALS TESTING; METHODOLOGY; THEORETICAL MODEL; THREE DIMENSIONAL IMAGING; TOOTH IMPLANT; TOOTH IMPLANTATION;

EID: 84872040192     PISSN: 01606972     EISSN: 15481336     Source Type: Journal    
DOI: 10.1563/AAID-JOI-D-10-00127     Document Type: Article
Times cited : (47)

References (32)
  • 1
    • 0019435541 scopus 로고
    • Osseointegrated titanium implants: Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man
    • Albrektsson T, Branemark PI, Hansson HA, Lindstrom J. Osseointegrated titanium implants: requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man. Acta Orthop Scand. 1981;52:155-170.
    • (1981) Acta Orthop Scand , vol.52 , pp. 155-170
    • Albrektsson, T.1    Branemark, P.I.2    Hansson, H.A.3    Lindstrom, J.4
  • 2
    • 0035377329 scopus 로고    scopus 로고
    • Application of finite element analysis in implant dentistry: A review of the literature
    • Geng JP, Tan KBC, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent. 2001;85:585-598.
    • (2001) J Prosthet Dent , vol.85 , pp. 585-598
    • Geng, J.P.1    Kbc, T.2    Liu, G.R.3
  • 3
    • 85016033318 scopus 로고
    • Mechanical loading of Branemark implants affects interfacial bone modelling and remodeling
    • Hoshaw SJ, Brunski JB, Cochran GVB. Mechanical loading of Branemark implants affects interfacial bone modelling and remodeling. Int J Oral Maxillofac Implants. 1994;9:345-360.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 345-360
    • Hoshaw, S.J.1    Brunski, J.B.2    Gvb, C.3
  • 4
    • 0027616941 scopus 로고
    • On clinical loading of osteointegrated implants: A methodological and clinical study
    • Glantz PO, Rangert B, Svensson A, et al. On clinical loading of osteointegrated implants: a methodological and clinical study. Clin Oral Implants Res. 1993;4:99-105.
    • (1993) Clin Oral Implants Res , vol.4 , pp. 99-105
    • Glantz, P.O.1    Rangert, B.2    Svensson, A.3
  • 5
    • 0030155880 scopus 로고    scopus 로고
    • In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants
    • Mericske-Stern R, Zarb GA. In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants. Clin Oral Implants Res. 1996;7:153-161.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 153-161
    • Mericske-Stern, R.1    Zarb, G.A.2
  • 6
    • 0034574104 scopus 로고    scopus 로고
    • Mechanical complications of dental implants
    • Schwartz MS. Mechanical complications of dental implants. Clin Oral Implants Res. 2000;11:156-158.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 156-158
    • Schwartz, M.S.1
  • 7
    • 19044381224 scopus 로고    scopus 로고
    • Evaluation of design parameters of osseointegrated dental implants using finite element analysis
    • Chun HJ, Cheong YS, Han JH, et al. Evaluation of design parameters of osseointegrated dental implants using finite element analysis. J Oral Rehabil. 2002;29:565-571.
    • (2002) J Oral Rehabil , vol.29 , pp. 565-571
    • Chun, H.J.1    Cheong, Y.S.2    Han, J.H.3
  • 8
    • 61449169063 scopus 로고    scopus 로고
    • Platform switching of dental implants panacea for crestal bone loss?
    • Deshpande SS, Sarin SP, Parkhedkar RD. Platform switching of dental implants: panacea for crestal bone loss? J Clin Diagn Res.2009;3:1348-1352.
    • (2009) J Clin Diagn Res , vol.3 , pp. 1348-1352
    • Deshpande, S.S.1    Sarin, S.P.2    Parkhedkar, R.D.3
  • 9
    • 0024031358 scopus 로고
    • Biomaterials and biomechanics in dental implant design
    • Brunski JB. Biomaterials and biomechanics in dental implant design. Int J Oral Maxillofac Implants 1988;3:85-97.
    • (1988) Int J Oral Maxillofac Implants , vol.3 , pp. 85-97
    • Brunski, J.B.1
  • 13
    • 0027353003 scopus 로고
    • Occlusal force and mandibular movements in patients with removable overdentures and fixed prostheses supported by implants in the maxilla
    • Jemt T, Book K, Karlsson S. Occlusal force and mandibular movements in patients with removable overdentures and fixed prostheses supported by implants in the maxilla. Int J Oral Maxillofac Implants. 1993;8:301-308.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 301-308
    • Jemt, T.1    Book, K.2    Karlsson, S.3
  • 14
    • 0023882786 scopus 로고
    • A threedimensional mathematical model of the human masticatory system predicting maximum possible bite forces
    • Koolstra JH, Van Eijden TMGJ, Weijs WA, Naeije M. A threedimensional mathematical model of the human masticatory system predicting maximum possible bite forces. J Biomech. 1988;21:563-576.
    • (1988) J Biomech , vol.21 , pp. 563-576
    • Koolstra, J.H.1    Van Eijden Tmgj2    Weijs, W.A.3    Naeije, M.4
  • 15
    • 0030322825 scopus 로고    scopus 로고
    • Simultaneous force measurements in 3 dimensions on oral endosseous implants in vitro and in vivo
    • Mericke-Stern R, Asal P, Buergin W. Simultaneous force measurements in 3 dimensions on oral endosseous implants in vitro and in vivo. Clin Oral Implants Res. 1996;7:378-386.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 378-386
    • Mericke-Stern, R.1    Asal, P.2    Buergin, W.3
  • 17
    • 0346930610 scopus 로고    scopus 로고
    • A comparison of threedimensional finite element stress analysis with in vitro strain gauge measurements on dental implants
    • Akca K, C ehreli MC, I?plikciog? lu H. A comparison of threedimensional finite element stress analysis with in vitro strain gauge measurements on dental implants. Int J Prosthodont. 2002;15:115-121.
    • (2002) Int J Prosthodont , vol.15 , pp. 115-121
    • Akca, K.1    Cehreli, M.C.2    Iplikcioglu, H.3
  • 18
    • 19044381224 scopus 로고    scopus 로고
    • Evaluation of design parameters of osseointegrated dental implants using finite element analysis
    • Chun HJ, Cheong YS, Han JH, et al. Evaluation of design parameters of osseointegrated dental implants using finite element analysis. J Oral Rehabil. 2002;29:565-571.
    • (2002) J Oral Rehabil , vol.29 , pp. 565-571
    • Chun, H.J.1    Cheong, Y.S.2    Han, J.H.3
  • 19
    • 0026266914 scopus 로고
    • Three dimensional finite element stress analysis in and around the screw-vent implant
    • Clelland NL, Ismail Y, Zaki HS, Pipko D. Three dimensional finite element stress analysis in and around the screw-vent implant. Int J Oral Maxillofac Implants. 1991;6:391-398.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 391-398
    • Clelland, N.L.1    Ismail, Y.2    Zaki, H.S.3    Pipko, D.4
  • 20
    • 0029312993 scopus 로고
    • Basic research: A three-dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla
    • Clelland NL, Lee JK, Bimbenet OC, Brantley AW. Basic research: a three-dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. J Prosthod. 1995;4:95-100.
    • (1995) J Prosthod , vol.4 , pp. 95-100
    • Clelland, N.L.1    Lee, J.K.2    Bimbenet, O.C.3    Brantley, A.W.4
  • 22
    • 0031612903 scopus 로고    scopus 로고
    • Influence of restoration type on stress distribution in bone around implants: A three-dimensional finite element analysis
    • Stegaroiu R, Sato T, Kusakari H, Miyakawa O. Influence of restoration type on stress distribution in bone around implants: a three-dimensional finite element analysis. Int J Oral Maxillofac Implants. 1998;13:82-90.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 82-90
    • Stegaroiu, R.1    Sato, T.2    Kusakari, H.3    Miyakawa, O.4
  • 23
    • 0032197414 scopus 로고    scopus 로고
    • Influence of prosthesis material on stress distribution in bone and implant: A 3-dimensional finite element analysis
    • Stegaroiu R, Kusakari H, Nishiyama S, Miyakawa O. Influence of prosthesis material on stress distribution in bone and implant: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants. 1998;13:781-790.
    • (1998) Int J Oral Maxillofac Implants , vol.13 , pp. 781-790
    • Stegaroiu, R.1    Kusakari, H.2    Nishiyama, S.3    Miyakawa, O.4
  • 24
    • 0025463278 scopus 로고
    • Finite element analysis of fixed prosthesis attached to osseointegrated implants
    • Williams KR, Watson WM, Scott J, Gregory M, Sinobad D. Finite element analysis of fixed prosthesis attached to osseointegrated implants. Quintessence Int. 1990;21:563-570.
    • (1990) Quintessence Int , vol.21 , pp. 563-570
    • Williams, K.R.1    Watson, W.M.2    Scott, J.3    Gregory, M.4    Sinobad, D.5
  • 25
    • 0031986671 scopus 로고    scopus 로고
    • Evaluating parameters of osseointegrated dental implants using finite element analysis: A two dimensional comparative study examining the effects of implant diameter, implant shape, and load direction
    • Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis: a two dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol. 1998;24:80-84.
    • (1998) J Oral Implantol , vol.24 , pp. 80-84
    • Holmgren, E.P.1    Seckinger, R.J.2    Kilgren, L.M.3    Mante, F.4
  • 26
    • 0026873529 scopus 로고
    • Failures and complications in 92 consecutively inserted overdentures supported by Branemark implants in severely resorbed edentulous maxillae: A study from prosthetic treatment to first annual check-up
    • Jemt T, Book K, Linden, Urde G. Failures and complications in 92 consecutively inserted overdentures supported by Branemark implants in severely resorbed edentulous maxillae: a study from prosthetic treatment to first annual check-up. Int J Oral Maxillofac Implants. 1992;7:162-167.
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 162-167
    • Jemt, T.1    Book, K.2    Linden3    Urde, G.4
  • 27
    • 0031088298 scopus 로고    scopus 로고
    • A multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: Preliminary results at six or more months of loading
    • Levine R, Clem D, Wilson T, Higgenbottom F, Saunders S. A multicenter retrospective analysis of the ITI implant system used for single-tooth replacements: preliminary results at six or more months of loading. Int J Oral Maxillofacial Implants. 1997;12:237-242.
    • (1997) Int J Oral Maxillofacial Implants , vol.12 , pp. 237-242
    • Levine, R.1    Clem, D.2    Wilson, T.3    Higgenbottom, F.4    Saunders, S.5
  • 28
    • 84995770421 scopus 로고
    • The new restorative concept of the ITI dental implant system: Design and engineering
    • Sutter F, Weber H, Sorenson J, Belser U. The new restorative concept of the ITI dental implant system: design and engineering. Int J Periodont Restor Dent. 1993;13:408-431.
    • (1993) Int J Periodont Restor Dent , vol.13 , pp. 408-431
    • Sutter, F.1    Weber, H.2    Sorenson, J.3    Belser, U.4
  • 29
    • 0028451094 scopus 로고
    • Tightening characteristics for screwed joints in osseointegrated dental implants
    • Burguete RL, Johns RB, King T, Patterson EA. Tightening characteristics for screwed joints in osseointegrated dental implants. J Prosth Dent. 1994;71:592-599.
    • (1994) J Prosth Dent , vol.71 , pp. 592-599
    • Burguete, R.L.1    Johns, R.B.2    King, T.3    Patterson, E.A.4
  • 30
    • 0034218915 scopus 로고    scopus 로고
    • Mechanics of the implant-abutment connection: An 8-degree taper compared to a butt joint connection
    • Merz BR, Hunenbart S, Belser UC. Mechanics of the implant-abutment connection: an 8-degree taper compared to a butt joint connection. Int J Oral Maxillofacial Implants. 2000;15:519-526.
    • (2000) Int J Oral Maxillofacial Implants , vol.15 , pp. 519-526
    • Merz, B.R.1    Hunenbart, S.2    Belser, U.C.3
  • 31
    • 0141832052 scopus 로고    scopus 로고
    • Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant: A nonlinear finite element stress analysis
    • Akca K, C ehreli MC, I?plikciog? lu H. Evaluation of the mechanical characteristics of the implant-abutment complex of a reduced-diameter morse-taper implant: a nonlinear finite element stress analysis. Clin Oral Impl Res. 2003;14:444-454.
    • (2003) Clin Oral Impl Res , vol.14 , pp. 444-454
    • Akca, K.1    Cehreli, M.C.2    Iplikciog Lu, H.3
  • 32
    • 33645347993 scopus 로고    scopus 로고
    • In vitro differences of stress concentrations for internal and external hex implant-abutment connections: A short communication
    • Maeda Y, Satoh T, Sogo M. In vitro differences of stress concentrations for internal and external hex implant-abutment connections: a short communication. J Oral Rehabil. 2006;33:75-78.
    • (2006) J Oral Rehabil , vol.33 , pp. 75-78
    • Maeda, Y.1    Satoh, T.2    Sogo, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.