메뉴 건너뛰기




Volumn 183, Issue , 2013, Pages 163-171

Evaluating the dynamic retention capacities of microfabricated vapor preconcentrators as a function of flow rate

Author keywords

Preconcentrator Microfabrication Vapor Wheeler Model VOC Microsystem

Indexed keywords

BREAKTHROUGH VOLUMES; DOWNSTREAM SEPARATION; MICRO ANALYTICAL SYSTEMS; OPERATING GUIDELINES; RELIABLE PERFORMANCE; VOLATILE ORGANIC COMPOUND (VOC); VOLUMETRIC FLOW RATE; WHEELER MODEL;

EID: 84876835856     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.03.105     Document Type: Article
Times cited : (14)

References (47)
  • 2
    • 0033803050 scopus 로고    scopus 로고
    • Performance evaluation of a sorbent tube sampling method using short path thermal desorption for volatile organic compounds
    • C.-Y. Peng, and S. Batterman Performance evaluation of a sorbent tube sampling method using short path thermal desorption for volatile organic compounds Journal of Environmental Monitoring 2 2000 313 324
    • (2000) Journal of Environmental Monitoring , vol.2 , pp. 313-324
    • Peng, C.-Y.1    Batterman, S.2
  • 3
    • 59349107483 scopus 로고    scopus 로고
    • Mass spectrometric investigations to obtain the first direct comparisons of endogenous breath and blood volatile organic compound concentrations in healthy volunteers
    • M.E. O'Hara, T.H. Clutton-Brock, S. Green, S. O'Hehir, and C.A. Mayhew Mass spectrometric investigations to obtain the first direct comparisons of endogenous breath and blood volatile organic compound concentrations in healthy volunteers International Journal of Mass Spectrometry 281 2009 92 96
    • (2009) International Journal of Mass Spectrometry , vol.281 , pp. 92-96
    • O'Hara, M.E.1    Clutton-Brock, T.H.2    Green, S.3    O'Hehir, S.4    Mayhew, C.A.5
  • 4
    • 79955478141 scopus 로고    scopus 로고
    • Analysis of the headspace composition of smokeless powders using GC-MS, GC-μECD and ion mobility spectrometry
    • M. Joshi, K. Rigsby, and J.R. Almirall Analysis of the headspace composition of smokeless powders using GC-MS, GC-μECD and ion mobility spectrometry Forensic Science International 208 2011 29 36
    • (2011) Forensic Science International , vol.208 , pp. 29-36
    • Joshi, M.1    Rigsby, K.2    Almirall, J.R.3
  • 7
    • 67949117037 scopus 로고    scopus 로고
    • Real-time monitoring of sub-ppb concentrations of aromatic volatiles with a MEMS-enabled miniaturized gas-chromatograph
    • S. Zampolli, I. Elmi, F. Mancarella, P. Betti, E. Dalcanale, G.C. Cardinali, and M. Severi Real-time monitoring of sub-ppb concentrations of aromatic volatiles with a MEMS-enabled miniaturized gas-chromatograph Sensors and Actuators B 141 2009 322 328
    • (2009) Sensors and Actuators B , vol.141 , pp. 322-328
    • Zampolli, S.1    Elmi, I.2    Mancarella, F.3    Betti, P.4    Dalcanale, E.5    Cardinali, G.C.6    Severi, M.7
  • 8
    • 80052792413 scopus 로고    scopus 로고
    • Microfabricated gas chromatograph for the selective determination of trichloroethylene vapor at sub-parts-per-billion concentrations in complex mixtures
    • S.K. Kim, H. Chang, and E.T. Zellers Microfabricated gas chromatograph for the selective determination of trichloroethylene vapor at sub-parts-per-billion concentrations in complex mixtures Analytical Chemistry 83 2011 7198 7206
    • (2011) Analytical Chemistry , vol.83 , pp. 7198-7206
    • Kim, S.K.1    Chang, H.2    Zellers, E.T.3
  • 9
    • 84861884620 scopus 로고    scopus 로고
    • Microfabricated gas chromatograph for on-site determination of trichloroethylene in indoor air arising from vapor intrusion. 1. Field evaluation
    • S.K. Kim, D.R. Burris, H. Chang, J. Bryant-Genevier, and E.T. Zellers Microfabricated gas chromatograph for on-site determination of trichloroethylene in indoor air arising from vapor intrusion. 1. Field evaluation Environmental Science and Technology 46 2012 6065 6072
    • (2012) Environmental Science and Technology , vol.46 , pp. 6065-6072
    • Kim, S.K.1    Burris, D.R.2    Chang, H.3    Bryant-Genevier, J.4    Zellers, E.T.5
  • 10
    • 84861849192 scopus 로고    scopus 로고
    • Microfabricated gas chromatograph for on-site determinations of TCE in indoor air arising from vapor intrusion. 2. Spatial/temporal monitoring
    • S.K. Kim, D.R. Burris, J. Bryant-Genevier, K.A. Gorder, E.M. Dettenmaier, and E.T. Zellers Microfabricated gas chromatograph for on-site determinations of TCE in indoor air arising from vapor intrusion. 2. Spatial/temporal monitoring Environmental Science and Technology 46 2012 6073 6080
    • (2012) Environmental Science and Technology , vol.46 , pp. 6073-6080
    • Kim, S.K.1    Burris, D.R.2    Bryant-Genevier, J.3    Gorder, K.A.4    Dettenmaier, E.M.5    Zellers, E.T.6
  • 11
    • 0023892531 scopus 로고
    • Preconcentration of gaseous organic pollutants in the atmosphere
    • J. Namiesnik Preconcentration of gaseous organic pollutants in the atmosphere Talanta 35 1988 567 587
    • (1988) Talanta , vol.35 , pp. 567-587
    • Namiesnik, J.1
  • 13
    • 33644528413 scopus 로고    scopus 로고
    • Evaluation of split/splitless operation and rapid heating of a multi-bed sorption trap used for gas chromatography analysis of large-volume air samples
    • J.J. Whiting, and R.D. Sacks Evaluation of split/splitless operation and rapid heating of a multi-bed sorption trap used for gas chromatography analysis of large-volume air samples Journal of Separation Science 29 2006 218 227
    • (2006) Journal of Separation Science , vol.29 , pp. 218-227
    • Whiting, J.J.1    Sacks, R.D.2
  • 14
    • 0035878105 scopus 로고    scopus 로고
    • A dual-adsorbent preconcentrator for a portable indoor-VOC microsensor system
    • C.J. Lu, and E.T. Zellers A dual-adsorbent preconcentrator for a portable indoor-VOC microsensor system Analytical Chemistry 73 2001 3449 3457
    • (2001) Analytical Chemistry , vol.73 , pp. 3449-3457
    • Lu, C.J.1    Zellers, E.T.2
  • 15
    • 0036677306 scopus 로고    scopus 로고
    • Multi-adsorbent preconcentration/focusing module for portable-GC/ microsensor-array analysis of complex vapor mixtures
    • C.J. Lu, and E.T. Zellers Multi-adsorbent preconcentration/focusing module for portable-GC/microsensor-array analysis of complex vapor mixtures Analyst 127 2002 1061 1068
    • (2002) Analyst , vol.127 , pp. 1061-1068
    • Lu, C.J.1    Zellers, E.T.2
  • 17
    • 22444451077 scopus 로고    scopus 로고
    • Multiple-stage microfabricated preconcentrator-focuser for micro gas chromatography system
    • DOI 10.1109/JMEMS.2005.844842
    • W.-C. Tian, H.K.L. Chan, C.J. Lu, S.W. Pang, and E.T. Zellers Multiple-stage microfabricated preconcentrator-focuser for micro gas chromatography system Journal of Microelectromechanical Systems 14 2005 498 507 (Pubitemid 41005069)
    • (2005) Journal of Microelectromechanical Systems , vol.14 , Issue.3 , pp. 498-507
    • Tian, W.-C.1    Chan, H.K.L.2    Lu, C.-J.3    Pang, S.W.4    Zellers, E.T.5
  • 19
    • 0038697738 scopus 로고    scopus 로고
    • A microfabricated microconcentrator for sensors and gas chromatography
    • DOI 10.1016/S0021-9673(03)00560-0
    • M. Kim, and S. Mitra A microfabricated micropreconcentrator for sensors and gas chromatography Journal of Chromatography A 996 2003 1 11 (Pubitemid 36627788)
    • (2003) Journal of Chromatography A , vol.996 , Issue.1-2 , pp. 1-11
    • Kim, M.1    Mitra, S.2
  • 22
    • 8744312792 scopus 로고    scopus 로고
    • Enhanced detection of m-xylene using a preconcentrator with a chemiresistor sensor
    • C.E. Davis, C.K. Ho, R.C. Hughes, and M.L. Thomas Enhanced detection of m-xylene using a preconcentrator with a chemiresistor sensor Sensors and Actuators B 104 2005 207 216
    • (2005) Sensors and Actuators B , vol.104 , pp. 207-216
    • Davis, C.E.1    Ho, C.K.2    Hughes, R.C.3    Thomas, M.L.4
  • 24
    • 46449112643 scopus 로고    scopus 로고
    • MEMS-based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents
    • B. Alfeeli, D. Cho, M. Ashraf-Khorassani, L.T. Taylor, and M. Agah MEMS-based multi-inlet/outlet preconcentrator coated by inkjet printing of polymer adsorbents Sensors and Actuators B 133 2008 24 32
    • (2008) Sensors and Actuators B , vol.133 , pp. 24-32
    • Alfeeli, B.1    Cho, D.2    Ashraf-Khorassani, M.3    Taylor, L.T.4    Agah, M.5
  • 25
    • 84869879336 scopus 로고    scopus 로고
    • A preconcentrator chip employing μ-SPME array coated with in-situ-synthesized carbon adsorbent film for VOCs analysis
    • M.-Y. Wong, W.-R. Cheng, M.-H. Liu, W.-C. Tian, and C.J. Lu A preconcentrator chip employing μ-SPME array coated with in-situ-synthesized carbon adsorbent film for VOCs analysis Talanta 101 2012 307 313
    • (2012) Talanta , vol.101 , pp. 307-313
    • Wong, M.-Y.1    Cheng, W.-R.2    Liu, M.-H.3    Tian, W.-C.4    Lu, C.J.5
  • 26
    • 79451473208 scopus 로고    scopus 로고
    • Solventless sample preparation techniques based on solid- and vapour-phase extraction
    • M. Urbanowicz, B. Zabiegata, and J. Namiesnik Solventless sample preparation techniques based on solid- and vapour-phase extraction Analytical and Bioanalytical Chemistry 399 2011 277 300
    • (2011) Analytical and Bioanalytical Chemistry , vol.399 , pp. 277-300
    • Urbanowicz, M.1    Zabiegata, B.2    Namiesnik, J.3
  • 27
    • 80053616207 scopus 로고    scopus 로고
    • Recent developments in solid-phase microextraction for on-site sampling and sample preparation
    • C. Duan, Z. Shen, D. Wu, and Y. Guan Recent developments in solid-phase microextraction for on-site sampling and sample preparation TrAC - Trends in Analytical Chemistry 30 2011 1568 1574
    • (2011) TrAC - Trends in Analytical Chemistry , vol.30 , pp. 1568-1574
    • Duan, C.1    Shen, Z.2    Wu, D.3    Guan, Y.4
  • 28
    • 0242664063 scopus 로고    scopus 로고
    • Novel preconcentration technique for on-line coupling to high-speed narrow-bore capillary gas chromatography: Sample enrichment by equilibrium (ab)sorption. I. Principles and theoretical aspects
    • DOI 10.1016/S0021-9673(97)00771-1, PII S0021967397007711
    • H.P. Tuan, H.G. Janssen, and C.A. Cramers Novel preconcentration technique for on-line coupling to high-speed narrow-bore capillary gas chromatography: sample enrichment by equilibrium (ab) sorption: I. Principles and theoretical aspects Journal of Chromatography A 791 1997 177 185 (Pubitemid 28064785)
    • (1997) Journal of Chromatography A , vol.791 , Issue.1-2 , pp. 177-185
    • Pham Tuan, H.1    Janssen, H.-G.2    Cramers, C.A.3
  • 32
    • 84862001742 scopus 로고    scopus 로고
    • Design and fabrication of a micropreconcentrator focuser for sensitivity enhancement of chemical sensing systems
    • A.B.A. Dow, and W. Lang Design and fabrication of a micropreconcentrator focuser for sensitivity enhancement of chemical sensing systems IEEE Sensors Journal 12 2012 2528 2534
    • (2012) IEEE Sensors Journal , vol.12 , pp. 2528-2534
    • Dow, A.B.A.1    Lang, W.2
  • 33
    • 33947195897 scopus 로고    scopus 로고
    • Membrane-suspended microgrid as a gas preconcentrator for chromatographic applications
    • DOI 10.1016/j.sna.2006.07.005, PII S0924424706005036, Special Issue of The Micromechanics section of Sensors and Actuators
    • A.M. Ruiz, I. Gràcia, N. Sabaté, P. Ivanov, A. Sánchez, M. Duch, M. Gerbolés, A. Moreno, and C. Cané Membrane-suspended microgrid as a gas preconcentrator for chromatographic applications Sensors and Actuators A 135 2007 192 196 (Pubitemid 46428098)
    • (2007) Sensors and Actuators, A: Physical , vol.135 , Issue.1 , pp. 192-196
    • Ruiz, A.M.1    Gracia, I.2    Sabate, N.3    Ivanov, P.4    Sanchez, A.5    Duch, M.6    Gerboles, M.7    Moreno, A.8    Cane, C.9
  • 37
    • 2342564530 scopus 로고    scopus 로고
    • The Wheeler Jonas equation: A versatile tool for the prediction of carbon bed breakthrough times
    • P. Lodewyckx, G.O. Wood, and S. Ryu The Wheeler Jonas equation: a versatile tool for the prediction of carbon bed breakthrough times Carbon 42 2004 1351 1355
    • (2004) Carbon , vol.42 , pp. 1351-1355
    • Lodewyckx, P.1    Wood, G.O.2    Ryu, S.3
  • 38
    • 0024445790 scopus 로고
    • A review of the Wheeler equation and comparison of its applications to organic vapor respirator cartridge breakthrough data
    • G.O. Wood, and E.S. Moyer A review of the Wheeler equation and comparison of its applications to organic vapor respirator cartridge breakthrough data American Industrial Hygiene Association Journal 50 1989 400 407 (Pubitemid 19263280)
    • (1989) American Industrial Hygiene Association Journal , vol.50 , Issue.8 , pp. 400-407
    • Wood, G.O.1    Moyer, E.S.2
  • 39
    • 0025720214 scopus 로고
    • A review and comparison of adsorption isotherm equations used to correlate and predict organic vapor cartridge capacities
    • G.O. Wood, and E.S. Moyer A review and comparison of adsorption isotherm equations used to correlate and predict organic vapor cartridge capacities American Industrial Hygiene Association Journal 52 1991 235 242
    • (1991) American Industrial Hygiene Association Journal , vol.52 , pp. 235-242
    • Wood, G.O.1    Moyer, E.S.2
  • 41
    • 0141926588 scopus 로고    scopus 로고
    • An extended equation for rate coefficients for adsorption of organic vapors and gases on activated carbons in air-purifying respirator cartridges
    • DOI 10.1202/443.1
    • G.O. Wood, and P. Lodewyckyx An extended equation for rate coefficients for adsorption of organic vapors and gases on activated carbons in air-purifying respirator cartridges American Industrial Hygiene Association Journal 64 2003 646 650 (Pubitemid 37248247)
    • (2003) American Industrial Hygiene Association Journal , vol.64 , Issue.5 , pp. 646-650
    • Wood, G.O.1    Lodewyckx, P.2
  • 43
    • 0000600338 scopus 로고
    • The kinetics of adsorption of carbon tetrachloride and chloroform from air mixtures by activated carbon
    • L.A. Jonas, and W. Svirbely The kinetics of adsorption of carbon tetrachloride and chloroform from air mixtures by activated carbon Journal of Catalysis 24 1972 446 459
    • (1972) Journal of Catalysis , vol.24 , pp. 446-459
    • Jonas, L.A.1    Svirbely, W.2
  • 45
    • 79953198314 scopus 로고    scopus 로고
    • Multi-stage preconcentrator/focuser module designed to enable trace level determinations of trichloroethylene in indoor air with a microfabricated gas chromatograph
    • T. Sukaew, H. Chang, G. Serrano, and E.T. Zellers Multi-stage preconcentrator/focuser module designed to enable trace level determinations of trichloroethylene in indoor air with a microfabricated gas chromatograph Analyst 136 2011 1664 1674
    • (2011) Analyst , vol.136 , pp. 1664-1674
    • Sukaew, T.1    Chang, H.2    Serrano, G.3    Zellers, E.T.4
  • 46
    • 84873286141 scopus 로고    scopus 로고
    • Hybrid preconcentrator/focuser module for determinations of explosive marker compounds with a micro-scale gas chromatograph
    • G. Serrano, T. Sukaew, and E.T. Zellers Hybrid preconcentrator/focuser module for determinations of explosive marker compounds with a micro-scale gas chromatograph Journal of Chromatography A 1279 2013 76 85
    • (2013) Journal of Chromatography A , vol.1279 , pp. 76-85
    • Serrano, G.1    Sukaew, T.2    Zellers, E.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.