메뉴 건너뛰기




Volumn 104, Issue 2, 2005, Pages 207-216

Enhanced detection of m-xylene using a preconcentrator with a chemiresistor sensor

Author keywords

Chemiresistor; Environmental monitoring; Limit of detection; m Xylene; Preconcentrator

Indexed keywords

CHEMICAL RESISTANCE; DESORPTION; ENVIRONMENTAL ENGINEERING; HYDROCARBONS; MICROSENSORS; PLASTIC FILMS; SOLVENTS; THERMAL EFFECTS; VAPOR PRESSURE; VOLATILE ORGANIC COMPOUNDS;

EID: 8744312792     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2004.04.120     Document Type: Article
Times cited : (57)

References (12)
  • 2
    • 0038535067 scopus 로고    scopus 로고
    • In-situ chemiresistor sensor package for real-time detection of volatile organic compounds in soil and groundwater
    • C.K. Ho, R.C. Hughes, In-situ chemiresistor sensor package for real-time detection of volatile organic compounds in soil and groundwater, Sensors 2 (2002) 23-34.
    • (2002) Sensors , vol.2 , pp. 23-34
    • Ho, C.K.1    Hughes, R.C.2
  • 3
    • 0033627093 scopus 로고    scopus 로고
    • Differentiation of chemical components in a binary solvent vapor mixture using carbon/polymer composite-based chemiresistors
    • S.V. Patel, M.W. Jenkins, R.C. Hughes, W. Graham Yelton, A.J. Ricco, Differentiation of chemical components in a binary solvent vapor mixture using carbon/polymer composite-based chemiresistors, Anal. Chem. 72 (2000) 1532-1542.
    • (2000) Anal. Chem. , vol.72 , pp. 1532-1542
    • Patel, S.V.1    Jenkins, M.W.2    Hughes, R.C.3    Graham Yelton, W.4    Ricco, A.J.5
  • 4
    • 0037099129 scopus 로고    scopus 로고
    • Dual-chemiresistor GC detector employing monolayer-protected metal nanocluster interfaces
    • Q.-Y. Cai, E.T. Zellers, Dual-chemiresistor GC detector employing monolayer-protected metal nanocluster interfaces, Anal. Chem. 74 (2002) 3533-3539.
    • (2002) Anal. Chem. , vol.74 , pp. 3533-3539
    • Cai, Q.-Y.1    Zellers, E.T.2
  • 7
    • 0032487350 scopus 로고    scopus 로고
    • Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: Selection and characterization of the preconcentrator adsorbent
    • W.A. Groves, E.T. Zellers, G.C. Frye, Analyzing organic vapors in exhaled breath using a surface acoustic wave sensor array with preconcentration: selection and characterization of the preconcentrator adsorbent, Anal. Chim. Acta 371 (1998) 131-143.
    • (1998) Anal. Chim. Acta , vol.371 , pp. 131-143
    • Groves, W.A.1    Zellers, E.T.2    Frye, G.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.