Volumn 6, Issue 3, 2006, Pages 784-794

Recent advancements in the gas-phase MicroChemLab

Author keywords

Acoustic detection microanalytical system; Gas chromatography; Gas phase analysis; Monolithic integration; Pivot plate resonator; Preconcentration; Surface acoustic wave array (SAW)

Indexed keywords

GAS CHROMATOGRAPHY; MICROCHANNELS; MICROMACHINING; MONOLITHIC INTEGRATED CIRCUITS; SILICON DETECTORS; TOXIC MATERIALS;

EID: 33947103078     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2006.874495     Document Type: Article
Times cited : (196)

References (19)
  • 7
    • 16644395906 scopus 로고    scopus 로고
    • Microfabrication of membrane-based devices by Deep-Reactive Ion Etching (DRIE) of silicon
    • Boston, MA, Nov. 1-6
    • R. P. Manginell, G. C. Frye-Mason, W. K. Schubert, R. J. Shul, and C. G. Willison, "Microfabrication of membrane-based devices by Deep-Reactive Ion Etching (DRIE) of silicon," in Proc. Electrochemical Society, Boston, MA, Nov. 1-6, 1998, vol. 98-2, p. 1151.
    • (1998) Proc. Electrochemical Society , vol.98 -2 , pp. 1151
    • Manginell, R.P.1    Frye-Mason, G.C.2    Schubert, W.K.3    Shul, R.J.4    Willison, C.G.5
  • 8
    • 0038547117 scopus 로고    scopus 로고
    • Microfabricated preconcentrator-focuser for a microscale gas Chromatograph
    • W. C. Tian, S. W. Pang, C. J. Lu, and E. T. Zellers, " Microfabricated preconcentrator-focuser for a microscale gas Chromatograph," J. Microelectromech. Syst., vol. 12, no. 4, pp. 264-27, 2003.
    • (2003) J. Microelectromech. Syst , vol.12 , Issue.4 , pp. 264-227
    • Tian, W.C.1    Pang, S.W.2    Lu, C.J.3    Zellers, E.T.4
  • 10
    • 33947186108 scopus 로고    scopus 로고
    • U.S. Patent 6068684
    • E. B. Overton, "," U.S. Patent 6068684.
    • Overton, E.B.1
  • 11
    • 0000891428 scopus 로고    scopus 로고
    • Sol-gel column technology for single-step deactivation, coating and stationary-phase immobilization in high-resolution capillary gas chromatography
    • D. X. Wang, S. L. Chong, and A. Malik, "Sol-gel column technology for single-step deactivation, coating and stationary-phase immobilization in high-resolution capillary gas chromatography," Analyt. Chem., vol. 69, no. 22, pp. 4566-457, 1997.
    • (1997) Analyt. Chem , vol.69 , Issue.22 , pp. 4566-4457
    • Wang, D.X.1    Chong, S.L.2    Malik, A.3
  • 14
    • 0030370190 scopus 로고    scopus 로고
    • Gas sensing with acoustic devices
    • S. J. Martin, "Gas sensing with acoustic devices," in Proc. Ultrasonics Symp., 1998, vol. 1, pp. 423-434.
    • (1998) Proc. Ultrasonics Symp , vol.1 , pp. 423-434
    • Martin, S.J.1
  • 15
    • 0034229409 scopus 로고    scopus 로고
    • Acoustic wave microsensor arrays for vapor sensing
    • J. W. Grate, "Acoustic wave microsensor arrays for vapor sensing," Chem. Rev., vol. 100, no. 7, pp. 2627-264, 2000.
    • (2000) Chem. Rev , vol.100 , Issue.7 , pp. 2627-2264
    • Grate, J.W.1
  • 16
    • 0033198573 scopus 로고    scopus 로고
    • Vapor recognition with small arrays of polymer-coated microsensors: A comprehensive analysis
    • J. Park, W. A. Groves, and E. T. Zellers, "Vapor recognition with small arrays of polymer-coated microsensors: a comprehensive analysis," Analyt. Chem., vol. 71, no. 17, pp. 3877-388, 1999.
    • (1999) Analyt. Chem , vol.71 , Issue.17 , pp. 3877-3388
    • Park, J.1    Groves, W.A.2    Zellers, E.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.