Volumn 215, Issue 1, 2013, Pages 78-87

Excimer laser deinsulation of Parylene-C on iridium for use in an activated iridium oxide film-coated Utah electrode array

Author keywords

Excimer laser; Iridium oxide; Laser deinsulation; Parylene; Photoablation; UEA

Indexed keywords

IRIDIUM; IRIDIUM OXIDE; METAL OXIDE; UNCLASSIFIED DRUG;

EID: 84875599548     PISSN: 01650270     EISSN: 1872678X     Source Type: Journal    
DOI: 10.1016/j.jneumeth.2013.02.010     Document Type: Article
Times cited : (17)

References (29)
  • 3
    • 44849136201 scopus 로고    scopus 로고
    • A novel method of fabricating convoluted shaped electrode arrays for neural and retinal prostheses
    • Bhandari R., Negi S., Rieth L., Normann R.A., Solzbacher F. A novel method of fabricating convoluted shaped electrode arrays for neural and retinal prostheses. Sens Actuators A: Phys 2008, 145-146:123-130.
    • (2008) Sens Actuators A: Phys , pp. 123-130
    • Bhandari, R.1    Negi, S.2    Rieth, L.3    Normann, R.A.4    Solzbacher, F.5
  • 4
    • 77955417168 scopus 로고    scopus 로고
    • A wafer-scale etching technique for high aspect ratio implantable MEMS structures
    • Bhandari R., Negi S., Rieth L., Solzbacher F. A wafer-scale etching technique for high aspect ratio implantable MEMS structures. Sens Actuators A: Phys 2010, 162:130-136.
    • (2010) Sens Actuators A: Phys , vol.162 , pp. 130-136
    • Bhandari, R.1    Negi, S.2    Rieth, L.3    Solzbacher, F.4
  • 6
    • 0026205082 scopus 로고
    • A silicon-based, three dimensional neural interface: manufacturing processes for an intra cortical electrode array
    • Campbell P.K., Jones K.E., Huber R.J., Horch K.W., Normann R.A. A silicon-based, three dimensional neural interface: manufacturing processes for an intra cortical electrode array. IEEE Trans Biomed Eng 1991, 38(38):758-768.
    • (1991) IEEE Trans Biomed Eng , vol.38 , Issue.38 , pp. 758-768
    • Campbell, P.K.1    Jones, K.E.2    Huber, R.J.3    Horch, K.W.4    Normann, R.A.5
  • 7
    • 50249084472 scopus 로고    scopus 로고
    • Neural stimulation and recording electrodes
    • Cogan S.F. Neural stimulation and recording electrodes. Annu Rev Biomed Eng 2008, 10:275-309.
    • (2008) Annu Rev Biomed Eng , vol.10 , pp. 275-309
    • Cogan, S.F.1
  • 8
    • 3242672495 scopus 로고    scopus 로고
    • Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation
    • Cogan S.F., Guzelian A.A., Agnew W.F., Yuen T.G.H., McCreery D.B. Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation. J Neurosci Methods 2004, 137:141-150.
    • (2004) J Neurosci Methods , vol.137 , pp. 141-150
    • Cogan, S.F.1    Guzelian, A.A.2    Agnew, W.F.3    Yuen, T.G.H.4    McCreery, D.B.5
  • 9
    • 0036260215 scopus 로고    scopus 로고
    • A model for the chemical vapor deposition of poly(para-xylylene) (Parylene) thin films
    • Fortin J.B., Lu T.M. A model for the chemical vapor deposition of poly(para-xylylene) (Parylene) thin films. Chem Mater 2002, 14:1945-1949.
    • (2002) Chem Mater , vol.14 , pp. 1945-1949
    • Fortin, J.B.1    Lu, T.M.2
  • 10
    • 0018468069 scopus 로고
    • Electrochromism in anodic iridium oxide films
    • Gottesfeld S., McIntyre J.D.E. Electrochromism in anodic iridium oxide films. J Electrochem Soc 1979, 126:742-750.
    • (1979) J Electrochem Soc , vol.126 , pp. 742-750
    • Gottesfeld, S.1    McIntyre, J.D.E.2
  • 11
    • 33746160271 scopus 로고    scopus 로고
    • Neuronal ensemble control of prosthetic devices by a human with tetraplegia
    • Hochberg L.R., Serruya M.D., Friehs G.M., Mukand J.A., Saleh M., Caplan A.H., et al. Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature 2006, 442:164-171.
    • (2006) Nature , vol.442 , pp. 164-171
    • Hochberg, L.R.1    Serruya, M.D.2    Friehs, G.M.3    Mukand, J.A.4    Saleh, M.5    Caplan, A.H.6
  • 12
    • 84939692967 scopus 로고
    • An in vitro analysis of metal electrodes for use in the neural environment
    • Johnson P.F., Hench L.L. An in vitro analysis of metal electrodes for use in the neural environment. Brain Behav Evol 1977, 14:23-45.
    • (1977) Brain Behav Evol , vol.14 , pp. 23-45
    • Johnson, P.F.1    Hench, L.L.2
  • 14
    • 0026692278 scopus 로고
    • X-ray photoelectron spectroscopy and electrochemical surface characterization of iridium(IV) oxide+ruthenium(IV) oxide electrodes
    • Kodintsev I.M., Trasatti S., Rubel M., Wieckowski A., Kaufher N. X-ray photoelectron spectroscopy and electrochemical surface characterization of iridium(IV) oxide+ruthenium(IV) oxide electrodes. Langmuir 1992, 8:283-290.
    • (1992) Langmuir , vol.8 , pp. 283-290
    • Kodintsev, I.M.1    Trasatti, S.2    Rubel, M.3    Wieckowski, A.4    Kaufher, N.5
  • 15
    • 51149205512 scopus 로고
    • Ambient gas effects on debris formed during KrF laser ablation of polyimide
    • Kuper S., Brannon J. Ambient gas effects on debris formed during KrF laser ablation of polyimide. Appl Phys Lett 1992, 60:1633-1635.
    • (1992) Appl Phys Lett , vol.60 , pp. 1633-1635
    • Kuper, S.1    Brannon, J.2
  • 16
    • 84855772496 scopus 로고    scopus 로고
    • KrF excimer laser micromachining of MEMS materials: characterization and applications
    • Liu K., NiCkolov Z., Oh J., Noh H.M. KrF excimer laser micromachining of MEMS materials: characterization and applications. J Micromech Microeng 2012, 22:015012.
    • (2012) J Micromech Microeng , vol.22 , pp. 015012
    • Liu, K.1    NiCkolov, Z.2    Oh, J.3    Noh, H.M.4
  • 17
    • 0017368305 scopus 로고
    • Parylene as a chronically stable, reproducible microelectrode insulator
    • Loeb G.E., Bak M.J., Salcman M., Schmidt E.M. Parylene as a chronically stable, reproducible microelectrode insulator. IEEE Trans Biomed Eng 1977, BME-24:121-128.
    • (1977) IEEE Trans Biomed Eng , vol.24 BME , pp. 121-128
    • Loeb, G.E.1    Bak, M.J.2    Salcman, M.3    Schmidt, E.M.4
  • 18
    • 84932429844 scopus 로고
    • Modification of apparent electrocatalysis for anodic chlorine evolution on electrochemically conditioned oxide films at iridium anodes
    • Mozota J., Conway B.E. Modification of apparent electrocatalysis for anodic chlorine evolution on electrochemically conditioned oxide films at iridium anodes. J Electrochem Soc 1981, 128:2142-2149.
    • (1981) J Electrochem Soc , vol.128 , pp. 2142-2149
    • Mozota, J.1    Conway, B.E.2
  • 19
    • 85027918817 scopus 로고    scopus 로고
    • UV laser ablation of Parylene films from gold substrates
    • Musaev O., Scott P., Wrobel J., Wolf J., Kruger M. UV laser ablation of Parylene films from gold substrates. J Mater Sci 2011, 46:183-187.
    • (2011) J Mater Sci , vol.46 , pp. 183-187
    • Musaev, O.1    Scott, P.2    Wrobel, J.3    Wolf, J.4    Kruger, M.5
  • 20
    • 60549083275 scopus 로고    scopus 로고
    • Effect of sputtering pressure on pulsed-DC sputtered iridium oxide films
    • Negi S., Bhandari R., Rieth L., Solzbacher F. Effect of sputtering pressure on pulsed-DC sputtered iridium oxide films. Sens Actuators B: Chem 2009, 137:370-378.
    • (2009) Sens Actuators B: Chem , vol.137 , pp. 370-378
    • Negi, S.1    Bhandari, R.2    Rieth, L.3    Solzbacher, F.4
  • 21
    • 77950870803 scopus 로고    scopus 로고
    • In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays
    • Negi S., Bhandari R., Rieth L., Solzbacher F. In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays. Biomed Mater 2010, 5:015007.
    • (2010) Biomed Mater , vol.5 , pp. 015007
    • Negi, S.1    Bhandari, R.2    Rieth, L.3    Solzbacher, F.4
  • 22
    • 72449176835 scopus 로고    scopus 로고
    • Neural electrode degradation from continuous electrical stimulation: comparison of sputtered and activated iridium oxide
    • Negi S., Bhandari R., Rieth L., Wagenen R.W., Solzbacher F. Neural electrode degradation from continuous electrical stimulation: comparison of sputtered and activated iridium oxide. J Neurosci Methods 2010, 8-17.
    • (2010) J Neurosci Methods , pp. 8-17
    • Negi, S.1    Bhandari, R.2    Rieth, L.3    Wagenen, R.W.4    Solzbacher, F.5
  • 23
    • 34547636880 scopus 로고    scopus 로고
    • Technology insight: future neuroprosthetic therapies for disorders of the nervous system
    • Normann R.A. Technology insight: future neuroprosthetic therapies for disorders of the nervous system. Nat Clin Pract Neurol 2007, 3:444-452.
    • (2007) Nat Clin Pract Neurol , vol.3 , pp. 444-452
    • Normann, R.A.1
  • 24
    • 0002407384 scopus 로고
    • A model for anodic hydrous oxide growth at iridium
    • Pickup P.G., Birss V.I. A model for anodic hydrous oxide growth at iridium. J Electroanal Chem Interf 1987, 220:83-100.
    • (1987) J Electroanal Chem Interf , vol.220 , pp. 83-100
    • Pickup, P.G.1    Birss, V.I.2
  • 25
    • 84948600170 scopus 로고
    • Activated Ir: An electrode suitable for reversible charge injection in saline solution
    • Robblee L.S., Lefko J.L., Brummer S.B., Activated Ir: An electrode suitable for reversible charge injection in saline solution. J Electrochem Soc 1983, 130:731-733.
    • (1983) J Electrochem Soc , vol.130 , pp. 731-733
    • Robblee, L.S.1    Lefko, J.L.2    Brummer, S.B.3
  • 26
    • 34249289377 scopus 로고    scopus 로고
    • An optically powered single-channel stimulation implant as test system for chronic biocompatibility and biostability of miniaturized retinal vision prostheses
    • Schanze T., Hesse L., Lau C., Greve N., Haberer W., Kammer S., et al. An optically powered single-channel stimulation implant as test system for chronic biocompatibility and biostability of miniaturized retinal vision prostheses. IEEE Trans Biomed Eng 2007, 54:983-992.
    • (2007) IEEE Trans Biomed Eng , vol.54 , pp. 983-992
    • Schanze, T.1    Hesse, L.2    Lau, C.3    Greve, N.4    Haberer, W.5    Kammer, S.6
  • 29
    • 84867947730 scopus 로고    scopus 로고
    • Hybrid laser and reactive ion etching of Parylene-C for deinsulation of a Utah electrode array
    • Yoo J.-M., Song J.-I., Tathireddy P., Solzbacher F., Rieth L.W. Hybrid laser and reactive ion etching of Parylene-C for deinsulation of a Utah electrode array. J Micromech Microeng 2012, 22:105036.
    • (2012) J Micromech Microeng , vol.22 , pp. 105036
    • Yoo, J.-M.1    Song, J.-I.2    Tathireddy, P.3    Solzbacher, F.4    Rieth, L.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.