메뉴 건너뛰기




Volumn 145-146, Issue 1-2, 2008, Pages 123-130

A novel method of fabricating convoluted shaped electrode arrays for neural and retinal prostheses

Author keywords

Dicing; Electrode arrays; Micromachining; Neural and retinal prostheses; Wet isotropic etching

Indexed keywords

METALLIZING;

EID: 44849136201     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2007.10.072     Document Type: Article
Times cited : (44)

References (7)
  • 1
    • 0026205082 scopus 로고
    • A silicon-based, three dimensional neural interface: manufacturing processes for an intra cortical electrode array
    • Campbell P.K., Jones K.E., Huber R.J., Horch K.W., and Normann R.A. A silicon-based, three dimensional neural interface: manufacturing processes for an intra cortical electrode array. IEEE Trans. Biomed. Eng. 38 August (38) (1991) 758-768
    • (1991) IEEE Trans. Biomed. Eng. , vol.38 , Issue.August 38 , pp. 758-768
    • Campbell, P.K.1    Jones, K.E.2    Huber, R.J.3    Horch, K.W.4    Normann, R.A.5
  • 2
    • 0026735250 scopus 로고
    • A glass/silicon composite intra cortical electrode array
    • Jones K.E., Campbell P.K., and Normann R.A. A glass/silicon composite intra cortical electrode array. Ann. Biomed. Eng. 20 (1992) 423-437
    • (1992) Ann. Biomed. Eng. , vol.20 , pp. 423-437
    • Jones, K.E.1    Campbell, P.K.2    Normann, R.A.3
  • 3
    • 0348147669 scopus 로고    scopus 로고
    • Long term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
    • Branner A., Stein R.B., Fernandez E., Aoyagi Y., and Normann R.A. Long term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve. IEEE Trans. Biomed. Eng. 51 1 (2004) 146-157
    • (2004) IEEE Trans. Biomed. Eng. , vol.51 , Issue.1 , pp. 146-157
    • Branner, A.1    Stein, R.B.2    Fernandez, E.3    Aoyagi, Y.4    Normann, R.A.5
  • 4
    • 0026882265 scopus 로고
    • Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
    • Edell D.J., Toi V., McNeil V.M., and Clark D. Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex. IEEE Trans. Biomed. Eng. 39 (1992) 635-643
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 635-643
    • Edell, D.J.1    Toi, V.2    McNeil, V.M.3    Clark, D.4
  • 5
    • 0026720316 scopus 로고
    • Bio-compatibility considerations at stimulating electrode interface
    • Beard R.B., Hung B.N., and Schmukler R. Bio-compatibility considerations at stimulating electrode interface. Ann. Biomed. Eng. 20 (1992) 395-410
    • (1992) Ann. Biomed. Eng. , vol.20 , pp. 395-410
    • Beard, R.B.1    Hung, B.N.2    Schmukler, R.3
  • 7
    • 44849139916 scopus 로고    scopus 로고
    • J.M. Hsu, L. Rieth, S. Kammer, K.P. Koch, R.A. Normann, F. Solzbacher, PECVD a-SiC:H and Parylene encapsulation for chronically implanted neural recording devices, NIH/NINDS Neural Interfaces Workshop, Bethesda, MD, September 7-9, 2005.
    • J.M. Hsu, L. Rieth, S. Kammer, K.P. Koch, R.A. Normann, F. Solzbacher, PECVD a-SiC:H and Parylene encapsulation for chronically implanted neural recording devices, NIH/NINDS Neural Interfaces Workshop, Bethesda, MD, September 7-9, 2005.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.