1
-
-
0001740359
-
Die Grundform des arteriellen pulses
-
O. Frank Die Grundform des arteriellen pulses Z Biol 37 1899 483 526
-
(1899)
Z Biol
, vol.37
, pp. 483-526
-
-
Frank, O.1
-
2
-
-
0027195184
-
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
-
K.H. Wesseling, J.R. Jansen, J.J. Settels Computation of aortic flow from pressure in humans using a nonlinear, three-element model J Appl Physiol 74 1993 2566 2573
-
(1993)
J Appl Physiol
, vol.74
, pp. 2566-2573
-
-
Wesseling, K.H.1
Jansen, J.R.2
Settels, J.J.3
-
3
-
-
0023730394
-
Assessment of Windkessel as a model of aortic input impedance
-
D. Burkhoff, J. Alexander Jr, J. Schipke Assessment of Windkessel as a model of aortic input impedance Am J Physiol 255 1988 H742 H753
-
(1988)
Am J Physiol
, vol.255
-
-
Burkhoff, D.1
Alexander, Jr.J.2
Schipke, J.3
-
4
-
-
0002220170
-
Photoelectric measurement of blood pressure, volume and flow in the finger
-
R. Albert, W.S. Vogt, W. Helbig, Conference Committee on the Xth International Conference on Medicine and Biological Engineering Dresden, Germany
-
J. Penaz Photoelectric measurement of blood pressure, volume and flow in the finger R. Albert, W.S. Vogt, W. Helbig, Digest of the International Conference on Medicine and Biological Engineering 1973 Conference Committee on the Xth International Conference on Medicine and Biological Engineering Dresden, Germany
-
(1973)
Digest of the International Conference on Medicine and Biological Engineering
-
-
Penaz, J.1
-
5
-
-
0001945079
-
Physiocal, calibrating finger vascular physiology for Finapres
-
K. Wesseling, B. DeWit, G. Van der Hoeven Physiocal, calibrating finger vascular physiology for Finapres Homeostasis 36 1995 67 82
-
(1995)
Homeostasis
, vol.36
, pp. 67-82
-
-
Wesseling, K.1
Dewit, B.2
Van Der Hoeven, G.3
-
6
-
-
0031051049
-
Models of brachial to finger pulse wave distortion and pressure decrement
-
P. Gizdulich, A. Prentza, K.H. Wesseling Models of brachial to finger pulse wave distortion and pressure decrement Cardiovasc Res 33 1997 698 705
-
(1997)
Cardiovasc Res
, vol.33
, pp. 698-705
-
-
Gizdulich, P.1
Prentza, A.2
Wesseling, K.H.3
-
7
-
-
0015147582
-
An artificial arterial system for pumping hearts
-
N. Westerhof, G. Elzinga, P. Sipkema An artificial arterial system for pumping hearts J Appl Physiol 31 1971 776 781
-
(1971)
J Appl Physiol
, vol.31
, pp. 776-781
-
-
Westerhof, N.1
Elzinga, G.2
Sipkema, P.3
-
8
-
-
0021249532
-
The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model
-
G.J. Langewouters, K.H. Wesseling, W.J. Goedhard The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model J Biomech 17 1984 425 435
-
(1984)
J Biomech
, vol.17
, pp. 425-435
-
-
Langewouters, G.J.1
Wesseling, K.H.2
Goedhard, W.J.3
-
9
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
J.M. Bland, D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
10
-
-
0033003166
-
A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
-
L.A. Critchley, J.A. Critchley A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques J Clin Monit Comput 15 1999 85 91
-
(1999)
J Clin Monit Comput
, vol.15
, pp. 85-91
-
-
Critchley, L.A.1
Critchley, J.A.2
-
11
-
-
0034757299
-
Cardiovascular magnetic resonance
-
D. Pennell Cardiovascular magnetic resonance Heart 85 2001 581 589
-
(2001)
Heart
, vol.85
, pp. 581-589
-
-
Pennell, D.1
-
12
-
-
0013978742
-
Development and evaluation of an impedance cardiac output system
-
W.G. Kubicek, J.N. Karnegis, R.P. Patterson Development and evaluation of an impedance cardiac output system Aerosp Med 37 1966 1208 1212
-
(1966)
Aerosp Med
, vol.37
, pp. 1208-1212
-
-
Kubicek, W.G.1
Karnegis, J.N.2
Patterson, R.P.3
-
13
-
-
77449150805
-
Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients
-
W. Raue, M. Swierzy, G. Koplin Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients Eur J Anaesthesiol 26 2009 1067 1071
-
(2009)
Eur J Anaesthesiol
, vol.26
, pp. 1067-1071
-
-
Raue, W.1
Swierzy, M.2
Koplin, G.3
-
14
-
-
27444433897
-
Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: A new tool for heart failure evaluation
-
P. Agostoni, G. Cattadori, A. Apostolo Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: A new tool for heart failure evaluation J Am Coll Cardiol 46 2005 1779 1781
-
(2005)
J Am Coll Cardiol
, vol.46
, pp. 1779-1781
-
-
Agostoni, P.1
Cattadori, G.2
Apostolo, A.3
-
15
-
-
0033974708
-
Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow
-
P. Christensen, P. Clemensen, P.K. Andersen Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow Crit Care Med 28 2000 51 56
-
(2000)
Crit Care Med
, vol.28
, pp. 51-56
-
-
Christensen, P.1
Clemensen, P.2
Andersen, P.K.3
-
16
-
-
68349110713
-
Noninvasive determination of cardiac output by the inert-gas-rebreathing method - Comparison with cardiovascular magnetic resonance imaging
-
J. Saur, S. Fluechter, F. Trinkmann Noninvasive determination of cardiac output by the inert-gas-rebreathing method - Comparison with cardiovascular magnetic resonance imaging Cardiology 114 2009 247 254
-
(2009)
Cardiology
, vol.114
, pp. 247-254
-
-
Saur, J.1
Fluechter, S.2
Trinkmann, F.3
-
17
-
-
77649249076
-
A novel noninvasive ultrasonic cardiac output monitor: Comparison with cardiac magnetic resonance
-
F. Trinkmann, C. Doesch, T. Papavassiliu A novel noninvasive ultrasonic cardiac output monitor: Comparison with cardiac magnetic resonance Clin Cardiol 33 2010 E8 E14
-
(2010)
Clin Cardiol
, vol.33
-
-
Trinkmann, F.1
Doesch, C.2
Papavassiliu, T.3
-
18
-
-
25144520471
-
Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery
-
K. Knobloch, A. Lichtenberg, M. Winterhalter Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery Ann Thorac Surg 80 2005 1479 1483
-
(2005)
Ann Thorac Surg
, vol.80
, pp. 1479-1483
-
-
Knobloch, K.1
Lichtenberg, A.2
Winterhalter, M.3
-
19
-
-
5044228901
-
Reconstruction of brachial pressure from finger arterial pressure during orthostasis
-
L.W. Bogert, M.P. Harms, F. Pott Reconstruction of brachial pressure from finger arterial pressure during orthostasis J Hypertens 22 2004 1873 1880
-
(2004)
J Hypertens
, vol.22
, pp. 1873-1880
-
-
Bogert, L.W.1
Harms, M.P.2
Pott, F.3
-
20
-
-
54449096406
-
Validation of brachial artery pressure reconstruction from finger arterial pressure
-
I. Guelen, B.E. Westerhof, G.L. van der Sar Validation of brachial artery pressure reconstruction from finger arterial pressure J Hypertens 26 2008 1321 1327
-
(2008)
J Hypertens
, vol.26
, pp. 1321-1327
-
-
Guelen, I.1
Westerhof, B.E.2
Van Der Sar, G.L.3
-
21
-
-
0034869820
-
A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
-
J.R. Jansen, J.J. Schreuder, J.P. Mulier A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients Br J Anaesth 87 2001 212 222
-
(2001)
Br J Anaesth
, vol.87
, pp. 212-222
-
-
Jansen, J.R.1
Schreuder, J.J.2
Mulier, J.P.3
-
22
-
-
0005928630
-
Continuous stroke volume monitoring by modeling flow from noninvasive measurement of arterial pressure in humans under orthostatic stress
-
M.P. Harms, K.H. Wesseling, F. Pott Continuous stroke volume monitoring by modeling flow from noninvasive measurement of arterial pressure in humans under orthostatic stress Clin Sci (Lond) 97 1999 291 301
-
(1999)
Clin Sci (Lond)
, vol.97
, pp. 291-301
-
-
Harms, M.P.1
Wesseling, K.H.2
Pott, F.3
-
23
-
-
0032942194
-
Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: A comparison with bolus injection thermodilution
-
W.T. Jellema, K.H. Wesseling, A.B. Groeneveld Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: A comparison with bolus injection thermodilution Anesthesiology 90 1999 1317 1328
-
(1999)
Anesthesiology
, vol.90
, pp. 1317-1328
-
-
Jellema, W.T.1
Wesseling, K.H.2
Groeneveld, A.B.3
-
24
-
-
34648831355
-
Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: Effects of alterations in arterial waveform
-
S. Lorsomradee, S. Cromheecke, S.G. De Hert Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: Effects of alterations in arterial waveform J Cardiothorac Vasc Anesth 21 2007 636 643
-
(2007)
J Cardiothorac Vasc Anesth
, vol.21
, pp. 636-643
-
-
Lorsomradee, S.1
Cromheecke, S.2
De Hert, S.G.3
-
25
-
-
84863096128
-
Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): Comparison of two monitoring sites with the thermodilution cardiac output
-
S. Vasdev, S. Chauhan, M. Choudhury Arterial pressure waveform derived cardiac output FloTrac/Vigileo system (third generation software): Comparison of two monitoring sites with the thermodilution cardiac output J Clin Monit Comput 26 2012 115 120
-
(2012)
J Clin Monit Comput
, vol.26
, pp. 115-120
-
-
Vasdev, S.1
Chauhan, S.2
Choudhury, M.3
-
26
-
-
84858159074
-
Clinical comparison of an echocardiograph-derived versus pulse counter-derived cardiac output measurement in abdominal aortic aneurysm surgery
-
Y. Kusaka, K. Yoshitani, T. Irie Clinical comparison of an echocardiograph-derived versus pulse counter-derived cardiac output measurement in abdominal aortic aneurysm surgery J Cardiothorac Vasc Anesth 26 2012 223 226
-
(2012)
J Cardiothorac Vasc Anesth
, vol.26
, pp. 223-226
-
-
Kusaka, Y.1
Yoshitani, K.2
Irie, T.3
-
27
-
-
79954546313
-
Comparison of two methods for cardiac output measurement in critically ill patients
-
E. Saraceni, S. Rossi, P. Persona Comparison of two methods for cardiac output measurement in critically ill patients Br J Anaesth 106 2011 690 694
-
(2011)
Br J Anaesth
, vol.106
, pp. 690-694
-
-
Saraceni, E.1
Rossi, S.2
Persona, P.3
-
28
-
-
84858433268
-
Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients
-
X. Monnet, N. Anguel, M. Jozwiak Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients Br J Anaesth 108 2012 615 622
-
(2012)
Br J Anaesth
, vol.108
, pp. 615-622
-
-
Monnet, X.1
Anguel, N.2
Jozwiak, M.3
-
29
-
-
80053589129
-
Comparison of invasive and noninvasive measurements of haemodynamic parameters in patients with advanced heart failure
-
M. Sokolski, A. Rydlewska, B. Krakowiak Comparison of invasive and noninvasive measurements of haemodynamic parameters in patients with advanced heart failure J Cardiovasc Med (Hagerstown) 12 2011 773 778
-
(2011)
J Cardiovasc Med (Hagerstown)
, vol.12
, pp. 773-778
-
-
Sokolski, M.1
Rydlewska, A.2
Krakowiak, B.3
-
30
-
-
78049488760
-
Pulse contour cardiac output derived from noninvasive arterial pressure in cardiovascular disease
-
L.W. Bogert, K.H. Wesseling, O. Schraa Pulse contour cardiac output derived from noninvasive arterial pressure in cardiovascular disease J Anesth 65 2010 1119 1125
-
(2010)
J Anesth
, vol.65
, pp. 1119-1125
-
-
Bogert, L.W.1
Wesseling, K.H.2
Schraa, O.3
-
31
-
-
70449646306
-
Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients
-
J.F. Stover, R. Stocker, R. Lenherr Noninvasive cardiac output and blood pressure monitoring cannot replace an invasive monitoring system in critically ill patients BMC Anesthesiol 9 2009 6
-
(2009)
BMC Anesthesiol
, vol.9
, pp. 6
-
-
Stover, J.F.1
Stocker, R.2
Lenherr, R.3
-
32
-
-
0036345861
-
Finapres arterial pulse wave analysis with Modelflow is not a reliable non-invasive method for assessment of cardiac output
-
J.J. Remmen, W.R. Aengevaeren, F.W. Verheugt Finapres arterial pulse wave analysis with Modelflow is not a reliable non-invasive method for assessment of cardiac output Clin Sci (Lond) 103 2002 143 149
-
(2002)
Clin Sci (Lond)
, vol.103
, pp. 143-149
-
-
Remmen, J.J.1
Aengevaeren, W.R.2
Verheugt, F.W.3
-
33
-
-
18044399456
-
Noninvasive estimation of cardiac output in critical care patients
-
U.M. Gerhardt, C. Schöller, D. Böcker Noninvasive estimation of cardiac output in critical care patients J Clin Monit Comput 16 2000 263 268
-
(2000)
J Clin Monit Comput
, vol.16
, pp. 263-268
-
-
Gerhardt, U.M.1
Schöller, C.2
Böcker, D.3
-
34
-
-
77956931912
-
Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery
-
C.M. Hofhuizen, J. Lemson, A.E. Hemelaar Continuous non-invasive finger arterial pressure monitoring reflects intra-arterial pressure changes in children undergoing cardiac surgery Br J Anaesth 105 2010 493 500
-
(2010)
Br J Anaesth
, vol.105
, pp. 493-500
-
-
Hofhuizen, C.M.1
Lemson, J.2
Hemelaar, A.E.3
-
35
-
-
0033035143
-
Noninvasive cardiac output assessment during moderate exercise: Pulse contour compared with CO2 rebreathing
-
S. Houtman, B. Oeseburg, M.T. Hopman Noninvasive cardiac output assessment during moderate exercise: Pulse contour compared with CO2 rebreathing Clin Physiol 19 1999 230 237
-
(1999)
Clin Physiol
, vol.19
, pp. 230-237
-
-
Houtman, S.1
Oeseburg, B.2
Hopman, M.T.3
-
36
-
-
83155181481
-
Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis
-
S.A. Bartels, W.J. Stok, R. Bezemer Noninvasive cardiac output monitoring during exercise testing: Nexfin pulse contour analysis compared to an inert gas rebreathing method and respired gas analysis J Clin Monit Comput 25 2011 315 321
-
(2011)
J Clin Monit Comput
, vol.25
, pp. 315-321
-
-
Bartels, S.A.1
Stok, W.J.2
Bezemer, R.3
-
37
-
-
22144477500
-
Noninvasive pulsatile arterial pressure and stroke volume changes from the human finger
-
L.W. Bogert, J.J. van Lieshout Noninvasive pulsatile arterial pressure and stroke volume changes from the human finger Exp Physiol 90 2005 437 446
-
(2005)
Exp Physiol
, vol.90
, pp. 437-446
-
-
Bogert, L.W.1
Van Lieshout, J.J.2
-
38
-
-
2142700056
-
Cardiac output by Modelflow method from intra-arterial and fingertip pulse pressure profiles
-
M. Azabji Kenfack, F. Lador, M. Licker Cardiac output by Modelflow method from intra-arterial and fingertip pulse pressure profiles Clin Sci (Lond) 106 2004 365 369
-
(2004)
Clin Sci (Lond)
, vol.106
, pp. 365-369
-
-
Azabji Kenfack, M.1
Lador, F.2
Licker, M.3
-
39
-
-
2142713077
-
Correction of cardiac output obtained by Modelflow from finger pulse pressure profiles with a respiratory method in humans
-
E. Tam, M. Azabji Kenfack, M. Cautero Correction of cardiac output obtained by Modelflow from finger pulse pressure profiles with a respiratory method in humans Clin Sci (Lond) 106 2004 371 376
-
(2004)
Clin Sci (Lond)
, vol.106
, pp. 371-376
-
-
Tam, E.1
Azabji Kenfack, M.2
Cautero, M.3
|