메뉴 건너뛰기




Volumn 33, Issue 2, 2010, Pages

A novel noninvasive ultrasonic cardiac output monitor: Comparison with cardiac magnetic resonance

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AORTA VALVE; ARTICLE; BODY MASS; CARDIOVASCULAR PARAMETERS; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DOPPLER ECHOCARDIOGRAPHY; FEMALE; GOLD STANDARD; HEART LEFT VENTRICLE OUTFLOW TRACT; HEART LEFT VENTRICLE OUTFLOW TRACT DIAMETER; HEART OUTPUT; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MEASUREMENT ERROR; NON INVASIVE MEASUREMENT; NUCLEAR MAGNETIC RESONANCE IMAGING; PROSPECTIVE STUDY; REPRODUCIBILITY; SINGLE BLIND PROCEDURE;

EID: 77649249076     PISSN: 01609289     EISSN: 19328737     Source Type: Journal    
DOI: 10.1002/clc.20612     Document Type: Article
Times cited : (19)

References (25)
  • 1
    • 9544228424 scopus 로고    scopus 로고
    • The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators
    • Connors AF Jr, Speroff T, Dawson NV, et al. The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA. 1996;276:889-897.
    • (1996) JAMA , vol.276 , pp. 889-897
    • Connors Jr, A.F.1    Speroff, T.2    Dawson, N.V.3
  • 2
    • 0043165013 scopus 로고    scopus 로고
    • Clinical use of cardiovascular magnetic resonance
    • Pohost GM, Hung L, Doyle M. Clinical use of cardiovascular magnetic resonance. Circulation. 2003;108:647-653.
    • (2003) Circulation , vol.108 , pp. 647-653
    • Pohost, G.M.1    Hung, L.2    Doyle, M.3
  • 3
    • 0034757299 scopus 로고    scopus 로고
    • Cardiovascular magnetic resonance
    • Pennell D. Cardiovascular magnetic resonance. Heart. 2001;85:581-589.
    • (2001) Heart , vol.85 , pp. 581-589
    • Pennell, D.1
  • 4
    • 0022975760 scopus 로고
    • Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients
    • Appel PL, Kram HB, Mackabee J, Fleming AW, Shoemaker WC. Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients. Crit Care Med. 1986;14:933-935.
    • (1986) Crit Care Med , vol.14 , pp. 933-935
    • Appel, P.L.1    Kram, H.B.2    Mackabee, J.3    Fleming, A.W.4    Shoemaker, W.C.5
  • 5
    • 0025916928 scopus 로고
    • Ideal measurement of cardiac output: Is impedance cardiography the answer?
    • Franko E, Van De Water J, Wang X. Ideal measurement of cardiac output: is impedance cardiography the answer? Vasc Endovascular Surg. 1991;25:550-558.
    • (1991) Vasc Endovascular Surg , vol.25 , pp. 550-558
    • Franko, E.1    Van De Water, J.2    Wang, X.3
  • 6
    • 23744481477 scopus 로고    scopus 로고
    • Comparison of impedance cardiography and thermodilutionderived measurements of stroke volume and cardiac output at rest and during exercise testing
    • Scherhag A, Kaden JJ, Kentschke E, Sueselbeck T, Borggrefe M. Comparison of impedance cardiography and thermodilutionderived measurements of stroke volume and cardiac output at rest and during exercise testing. Cardiovasc Drugs Ther. 2005;19:141-147.
    • (2005) Cardiovasc Drugs Ther , vol.19 , pp. 141-147
    • Scherhag, A.1    Kaden, J.J.2    Kentschke, E.3    Sueselbeck, T.4    Borggrefe, M.5
  • 7
    • 27444433897 scopus 로고    scopus 로고
    • Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: A new tool for heart failure evaluation
    • Agostoni P, Cattadori G, Apostolo A, et al. Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: a new tool for heart failure evaluation. J Am Coll Cardiol. 2005;46:1779-1781.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1779-1781
    • Agostoni, P.1    Cattadori, G.2    Apostolo, A.3
  • 8
    • 33644797321 scopus 로고    scopus 로고
    • Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients
    • Dong L, Wang JA, Jiang CY. Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients. J Zhejiang Univ Sci B. 2005;6:1157-1162.
    • (2005) J Zhejiang Univ Sci B , vol.6 , pp. 1157-1162
    • Dong, L.1    Wang, J.A.2    Jiang, C.Y.3
  • 9
    • 0141749277 scopus 로고    scopus 로고
    • Noninvasive determination of cardiac output in ventilated patients. Clinical evaluation of a simplified quick method]. Article in German
    • Reutershan J, Kapp T, Unertl K, Fretschner R. [Noninvasive determination of cardiac output in ventilated patients. Clinical evaluation of a simplified quick method]. Article in German. Anaesthesist. 2003;52:778-786.
    • (2003) Anaesthesist , vol.52 , pp. 778-786
    • Reutershan, J.1    Kapp, T.2    Unertl, K.3    Fretschner, R.4
  • 10
    • 0033974708 scopus 로고    scopus 로고
    • Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow
    • Christensen P, Clemensen P, Andersen PK,Henneberg SW. Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow. Crit Care Med. 2000;28:51-56.
    • (2000) Crit Care Med , vol.28 , pp. 51-56
    • Christensen, P.1    Clemensen, P.2    Andersen, P.K.3    Henneberg, S.W.4
  • 11
    • 67651015616 scopus 로고    scopus 로고
    • Noninvasive determination of cardiac output: Comparison of a novel CW Doppler ultrasonic technique and inert gas rebreathing
    • doi:10.1016/j.ijcard.2008.04.057
    • Saur J, Trinkmann F, Weissmann J, Borggrefe M, Kaden JJ. Noninvasive determination of cardiac output: comparison of a novel CW Doppler ultrasonic technique and inert gas rebreathing. Int J Cardiol. 2008 doi:10.1016/j.ijcard.2008.04.057.
    • (2008) Int J Cardiol
    • Saur, J.1    Trinkmann, F.2    Weissmann, J.3    Borggrefe, M.4    Kaden, J.J.5
  • 12
    • 25144520471 scopus 로고    scopus 로고
    • Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery
    • Knobloch K, Lichtenberg A, Winterhalter M, Rossner D, Pichlmaier M, Phillips R. Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery. Ann Thorac Surg. 2005;80: 1479-1483.
    • (2005) Ann Thorac Surg , vol.80 , pp. 1479-1483
    • Knobloch, K.1    Lichtenberg, A.2    Winterhalter, M.3    Rossner, D.4    Pichlmaier, M.5    Phillips, R.6
  • 13
    • 14844354490 scopus 로고    scopus 로고
    • Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit
    • Tan HL, Pinder M, Parsons R, Roberts B, van Heerden PV. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth. 2005;94:287-291.
    • (2005) Br J Anaesth , vol.94 , pp. 287-291
    • Tan, H.L.1    Pinder, M.2    Parsons, R.3    Roberts, B.4    van Heerden, P.V.5
  • 14
    • 37049033068 scopus 로고    scopus 로고
    • USCOM (Ultrasonic Cardiac Output Monitors) lacks agreement with thermodilution cardiac output and transoesophageal echocardiography valve measurements
    • Van den Oever HL, Murphy EJ, Christie-Taylor GA. USCOM (Ultrasonic Cardiac Output Monitors) lacks agreement with thermodilution cardiac output and transoesophageal echocardiography valve measurements. Anaesth Intensive Care. 2007;35:903-910.
    • (2007) Anaesth Intensive Care , vol.35 , pp. 903-910
    • Van den Oever, H.L.1    Murphy, E.J.2    Christie-Taylor, G.A.3
  • 15
    • 46149097864 scopus 로고    scopus 로고
    • Cardiac output measurement in children: Comparison of the ultrasound cardiac output monitor with thermodilution cardiac output measurement
    • Knirsch W, Kretschmar O, Tomaske M, et al. Cardiac output measurement in children: comparison of the ultrasound cardiac output monitor with thermodilution cardiac output measurement. Intensive Care Med. 2008;34:1060-1064.
    • (2008) Intensive Care Med , vol.34 , pp. 1060-1064
    • Knirsch, W.1    Kretschmar, O.2    Tomaske, M.3
  • 16
    • 33846979129 scopus 로고    scopus 로고
    • Measurement of cardiac output with a non-invasive continuous wave Doppler device versus the pulmonary artery catheter: A comparative study
    • Chan JS, Segara D, Nair P. Measurement of cardiac output with a non-invasive continuous wave Doppler device versus the pulmonary artery catheter: a comparative study. Crit Care Resusc. 2006;8:309-314.
    • (2006) Crit Care Resusc , vol.8 , pp. 309-314
    • Chan, J.S.1    Segara, D.2    Nair, P.3
  • 17
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • Stetz CW, Miller RG, Kelly GE, Raffin TA. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis. 1982;126:1001-1004.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3    Raffin, T.A.4
  • 18
    • 0036385496 scopus 로고    scopus 로고
    • Lack of agreement between thermodilution and fick cardiac output in critically ill patients
    • Dhingra VK, Fenwick JC, Walley KR, Chittock DR, Ronco JJ. Lack of agreement between thermodilution and fick cardiac output in critically ill patients. Chest. 2002;122:990-997.
    • (2002) Chest , vol.122 , pp. 990-997
    • Dhingra, V.K.1    Fenwick, J.C.2    Walley, K.R.3    Chittock, D.R.4    Ronco, J.J.5
  • 19
    • 0026506397 scopus 로고
    • New perspectives in the assessment of cardiac chamber dimensions during development and adulthood
    • Nidorf SM, Picard MH, Triulzi MO, et al. New perspectives in the assessment of cardiac chamber dimensions during development and adulthood. J Am Coll Cardiol. 1992;19:983-988.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 983-988
    • Nidorf, S.M.1    Picard, M.H.2    Triulzi, M.O.3
  • 20
    • 20744453356 scopus 로고    scopus 로고
    • Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging
    • Papavassiliu T, Kuhl HP, Schroder M, et al. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology. 2005;236:57-64.
    • (2005) Radiology , vol.236 , pp. 57-64
    • Papavassiliu, T.1    Kuhl, H.P.2    Schroder, M.3
  • 21
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 22
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85-91.
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 23
    • 43049154414 scopus 로고    scopus 로고
    • Non-invasive ultrasonic cardiac output monitoring in exercise testing
    • Knobloch K, Hoeltke V, Jakob E, Vogt PM, Phillips R. Non-invasive ultrasonic cardiac output monitoring in exercise testing. Int J Cardiol. 2008;126:445-447.
    • (2008) Int J Cardiol , vol.126 , pp. 445-447
    • Knobloch, K.1    Hoeltke, V.2    Jakob, E.3    Vogt, P.M.4    Phillips, R.5
  • 24
    • 0037392139 scopus 로고    scopus 로고
    • Cardiac output measurement after coronary artery bypass grafting using bolus thermodilution, continuous thermodilution, and whole-body impedance cardiography
    • Kaukinen S, Koobi T, Bi Y, Turjanmaa VM. Cardiac output measurement after coronary artery bypass grafting using bolus thermodilution, continuous thermodilution, and whole-body impedance cardiography. J Cardiothorac Vasc Anesth. 2003;17:199-203.
    • (2003) J Cardiothorac Vasc Anesth , vol.17 , pp. 199-203
    • Kaukinen, S.1    Koobi, T.2    Bi, Y.3    Turjanmaa, V.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.