메뉴 건너뛰기




Volumn 28, Issue 1, 2000, Pages 51-56

Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow

Author keywords

Cardiac output; Functional residual capacity; Intensive care; Intrapulmonary shunt fraction; Mass spectrometry; Mechanical ventilation; Noninvasive methods; Pulmonary gas exchange

Indexed keywords

INERT GAS;

EID: 0033974708     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003246-200001000-00008     Document Type: Article
Times cited : (46)

References (20)
  • 1
    • 0016606374 scopus 로고
    • Diffusing capacity, membrane diffusing capacity, capillary blood volume, pulmonary tissue volume, and cardiac output measured by a rebreathing technique
    • 1. Sackner MA, Greeneltch D, Heiman MS, et al: Diffusing capacity, membrane diffusing capacity, capillary blood volume, pulmonary tissue volume, and cardiac output measured by a rebreathing technique. Am Rev Respir Dis 1975; 111:157-164
    • (1975) Am Rev Respir Dis , vol.111 , pp. 157-164
    • Sackner, M.A.1    Greeneltch, D.2    Heiman, M.S.3
  • 2
    • 0017362189 scopus 로고
    • Noninvasive determination of cardiac output by a modified acetylene rebreathing procedure utilizing mass spectrometer measurements
    • 2. Triebwasser JH, Johnson RL, Burpo RP, et al: Noninvasive determination of cardiac output by a modified acetylene rebreathing procedure utilizing mass spectrometer measurements. Aviat Space Environ Med 1977; 48: 203-209
    • (1977) Aviat Space Environ Med , vol.48 , pp. 203-209
    • Triebwasser, J.H.1    Johnson, R.L.2    Burpo, R.P.3
  • 3
    • 0020627284 scopus 로고
    • Reproducibility of rebreathing parameters in normal humans
    • 3. Petrini MF, Phillips MS, Dwyer TM, et al: Reproducibility of rebreathing parameters in normal humans. Lung 1983; 161:327-335
    • (1983) Lung , vol.161 , pp. 327-335
    • Petrini, M.F.1    Phillips, M.S.2    Dwyer, T.M.3
  • 4
    • 0021707408 scopus 로고
    • Measurement of cardiopulmonary function by rebreathing methodology in piglets
    • 4. Mentz WM, Lawson EE, Friedman M: Measurement of cardiopulmonary function by rebreathing methodology in piglets. Pediatr Res 1984; 18:1167-1172
    • (1984) Pediatr Res , vol.18 , pp. 1167-1172
    • Mentz, W.M.1    Lawson, E.E.2    Friedman, M.3
  • 5
    • 0030931326 scopus 로고    scopus 로고
    • The non-invasive acetylene rebreathing method for estimation of cardiac output: Influence of breath-by-breath variation
    • 5. Hansen S, Wendelboe O, Christensen P: The non-invasive acetylene rebreathing method for estimation of cardiac output: Influence of breath-by-breath variation. Clin Physiol 1997; 17:193-202
    • (1997) Clin Physiol , vol.17 , pp. 193-202
    • Hansen, S.1    Wendelboe, O.2    Christensen, P.3
  • 6
    • 0021879076 scopus 로고
    • Effect of the rebreathing pattern on pulmonary tissue volume and capillary blood flow
    • 6. Kallay MC, Hyde RW, Fahey PJ, et al: Effect of the rebreathing pattern on pulmonary tissue volume and capillary blood flow. J Appl Physiol 1985; 58:1881-1894
    • (1985) J Appl Physiol , vol.58 , pp. 1881-1894
    • Kallay, M.C.1    Hyde, R.W.2    Fahey, P.J.3
  • 7
    • 0018243356 scopus 로고
    • Lung tissue volume and blood flow by rebreathing: Theory
    • 7. Petrini MF, Peterson BT, Hyde RW: Lung tissue volume and blood flow by rebreathing: Theory. J Appl Physiol 1978; 44:795-802
    • (1978) J Appl Physiol , vol.44 , pp. 795-802
    • Petrini, M.F.1    Peterson, B.T.2    Hyde, R.W.3
  • 8
    • 0000706297 scopus 로고
    • Determination of pulmonary parenchymal tissue volume and pulmonary capillary blood flow in man
    • 8. Cander L, Forster RE: Determination of pulmonary parenchymal tissue volume and pulmonary capillary blood flow in man. J Appl Physiol 1959; 14(4):541-551
    • (1959) J Appl Physiol , vol.14 , Issue.4 , pp. 541-551
    • Cander, L.1    Forster, R.E.2
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 9. Bland JM, Altman DC: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.C.2
  • 10
    • 0001704910 scopus 로고
    • Ein method zur vergleichenden messung des hertzschlag-volumens beim menschen
    • 10. Bornstein A: Ein method zur vergleichenden messung des hertzschlag-volumens beim menschen. Arch Ges Physiol 1910; 132: 307-318
    • (1910) Arch Ges Physiol , vol.132 , pp. 307-318
    • Bornstein, A.1
  • 11
    • 0001226022 scopus 로고
    • The determination of cardiac output of man by the use of acetylene
    • 11. Grollmann A: The determination of cardiac output of man by the use of acetylene. Am J Physiol 1929; 88:432-445
    • (1929) Am J Physiol , vol.88 , pp. 432-445
    • Grollmann, A.1
  • 12
    • 0003189637 scopus 로고
    • The cardiac output in rest and work determined simultaneously by the acetylene and dye injection methods
    • 12. Asmussen E, Nielsen M: The cardiac output in rest and work determined simultaneously by the acetylene and dye injection methods. Ada Physiol Scand 1953; 27:217-230
    • (1953) Acta Physiol Scand , vol.27 , pp. 217-230
    • Asmussen, E.1    Nielsen, M.2
  • 13
    • 0022510712 scopus 로고
    • Evaluation of a modified acetylene rebreathing method for the determination of cardiac output
    • 13. Nyström J, Celsing F, Carlens P, et al: Evaluation of a modified acetylene rebreathing method for the determination of cardiac output. Clin Physiol 1986; 6:253-268
    • (1986) Clin Physiol , vol.6 , pp. 253-268
    • Nyström, J.1    Celsing, F.2    Carlens, P.3
  • 14
    • 0017758958 scopus 로고
    • The pulmonary hemodynamic effects of aerosols of isoproterenol and ipratropium in normal subjects and patients with reversible airway obstruction
    • 14. Sackner MA, Friedman M, Silva G, et al: The pulmonary hemodynamic effects of aerosols of isoproterenol and ipratropium in normal subjects and patients with reversible airway obstruction. Am Rev Respir Dis 1977; 116: 1013-1022
    • (1977) Am Rev Respir Dis , vol.116 , pp. 1013-1022
    • Sackner, M.A.1    Friedman, M.2    Silva, G.3
  • 15
    • 0024560407 scopus 로고
    • Noninvasive determination of effective (non-shunted) pulmonary blood flow in normal and injured lungs
    • 15. Steinhart CM, Burch KD, Brudno S, et al: Noninvasive determination of effective (non-shunted) pulmonary blood flow in normal and injured lungs. Crit Care Med 1989; 17: 349-353
    • (1989) Crit Care Med , vol.17 , pp. 349-353
    • Steinhart, C.M.1    Burch, K.D.2    Brudno, S.3
  • 16
    • 0022650693 scopus 로고
    • Measurement of cardiopulmonary function in ventilated neonates with respiratory distress syndrome using rebreathing methodology
    • 16. Bose CL, Lawson EE, Greene A, et al: Measurement of cardiopulmonary function in ventilated neonates with respiratory distress syndrome using rebreathing methodology. Pediatr Res 1986; 20:316-320
    • (1986) Pediatr Res , vol.20 , pp. 316-320
    • Bose, C.L.1    Lawson, E.E.2    Greene, A.3
  • 17
    • 0025171199 scopus 로고
    • Repeatability of the acetylene rebreathing method in measuring cardiac output: Influence of acetylene concentration
    • 17. Nielsen OW, Hansen S, Christensen P, et al: Repeatability of the acetylene rebreathing method in measuring cardiac output: Influence of acetylene concentration. Acta Anaesthesiol Scand 1990; 34:354-357
    • (1990) Acta Anaesthesiol Scand , vol.34 , pp. 354-357
    • Nielsen, O.W.1    Hansen, S.2    Christensen, P.3
  • 18
    • 0018874013 scopus 로고
    • Analysis of rebreathing measurements of pulmonary tissue volume in pulmonary edema
    • 18. Friedman M, Kaufman SH, Wilkins SA: Analysis of rebreathing measurements of pulmonary tissue volume in pulmonary edema. J Appl Physiol 1980; 48:66-71
    • (1980) J Appl Physiol , vol.48 , pp. 66-71
    • Friedman, M.1    Kaufman, S.H.2    Wilkins, S.A.3
  • 19
    • 0008882129 scopus 로고
    • Lung water and cardiac output determination by noninvasive trace gas analysis of dual breathholds in a single breath
    • 19. Severinghaus JW, Ozanne CM, Louderbough HC, et al: Lung water and cardiac output determination by noninvasive trace gas analysis of dual breathholds in a single breath. Prog Respir Res 1979; 11:280-296
    • (1979) Prog Respir Res , vol.11 , pp. 280-296
    • Severinghaus, J.W.1    Ozanne, C.M.2    Louderbough, H.C.3
  • 20
    • 0019133531 scopus 로고
    • Pulmonary blood flow and tissue volume. Assessment of a non-invasive technique of measurement
    • 20. Salt JC, Gothard JWW, Brantwaite MA: Pulmonary blood flow and tissue volume. Assessment of a non-invasive technique of measurement. Anaesthesiology 1980; 35: 1054-1059
    • (1980) Anaesthesiology , vol.35 , pp. 1054-1059
    • Salt, J.C.1    Gothard, J.W.W.2    Brantwaite, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.