메뉴 건너뛰기




Volumn 114, Issue 4, 2009, Pages 247-254

Noninvasive determination of cardiac output by the inert-gas-rebreathing method - Comparison with cardiovascular magnetic resonance imaging

Author keywords

Cardiac output; Cardiovascular magnetic resonance imaging; Inert gas; Rebreathing

Indexed keywords

INERT GAS;

EID: 68349110713     PISSN: 00086312     EISSN: None     Source Type: Journal    
DOI: 10.1159/000232407     Document Type: Article
Times cited : (46)

References (31)
  • 1
    • 0043165013 scopus 로고    scopus 로고
    • Clinical use of cardiovascular magnetic resonance
    • Pohost GM, Hung L, Doyle M: Clinical use of cardiovascular magnetic resonance. Circulation 2003; 108: 647-653.
    • (2003) Circulation , vol.108 , pp. 647-653
    • Pohost, G.M.1    Hung, L.2    Doyle, M.3
  • 2
    • 0034757299 scopus 로고    scopus 로고
    • Cardiovascular magnetic resonance
    • Pennell D: Cardiovascular magnetic resonance. Heart 2001; 85: 581-589.
    • (2001) Heart , vol.85 , pp. 581-589
    • Pennell, D.1
  • 3
    • 0033879659 scopus 로고    scopus 로고
    • Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography radionuclide ventriculography and cardiovascular magnetic resonance; Are they interchangeable?
    • Bellenger NG, Burgess MI, Ray SG, Lahiri A, Coats AJ, Cleland JG, Pennell DJ: Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable? Eur Heart J 2000; 21: 1387-1396.
    • (2000) Eur Heart J , vol.21 , pp. 1387-1396
    • Bellenger, N.G.1    Burgess, M.I.2    Ray, S.G.3    Lahiri, A.4    Coats, A.J.5    Cleland, J.G.6    Pennell, D.J.7
  • 4
    • 0022975760 scopus 로고
    • Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients
    • Appel PL, Kram HB, Mackabee J, Fleming AW, Shoemaker WC: Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients. Crit Care Med 1986; 14: 933-935.
    • (1986) Crit Care Med , vol.14 , pp. 933-935
    • Appel, P.L.1    Kram, H.B.2    MacKabee, J.3    Fleming, A.W.4    Shoemaker, W.C.5
  • 5
    • 0025916928 scopus 로고
    • Ideal measurement of cardiac output: Is impedance cardiography the answer?
    • Franko E, Van De Water J, Wang X: Ideal measurement of cardiac output: is impedance cardiography the answer? Vasc Endovascular Surg 1991; 25: 550-558.
    • (1991) Vasc Endovascular Surg , vol.25 , pp. 550-558
    • Franko, E.1    Van De Water, J.2    Wang, X.3
  • 6
    • 25144520471 scopus 로고    scopus 로고
    • Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery
    • DOI 10.1016/j.athoracsur.2004.12.034, PII S0003497504024798
    • Knobloch K, Lichtenberg A, Winterhalter M, Rossner D, Pichlmaier M, Phillips R: Noninvasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery. Ann Thorac Surg 2005; 80: 1479-1483. (Pubitemid 41354141)
    • (2005) Annals of Thoracic Surgery , vol.80 , Issue.4 , pp. 1479-1483
    • Knobloch, K.1    Lichtenberg, A.2    Winterhalter, M.3    Rossner, D.4    Pichlmaier, M.5    Phillips, R.6
  • 7
    • 14844354490 scopus 로고    scopus 로고
    • Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit
    • Tan HL, Pinder M, Parsons R, Roberts B, van Heerden PV: Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth 2005; 94: 287-291.
    • (2005) Br J Anaesth , vol.94 , pp. 287-291
    • Tan, H.L.1    Pinder, M.2    Parsons, R.3    Roberts, B.4    Van Heerden, P.V.5
  • 9
    • 0344640673 scopus 로고
    • Measurement of the blood flow through the lungs of man
    • Krogh A, Lindhard J: Measurement of the blood flow through the lungs of man. Scand Arch Physiol 1912; 27: 100-125.
    • (1912) Scand Arch Physiol , vol.27 , pp. 100-125
    • Krogh, A.1    Lindhard, J.2
  • 10
    • 0037289834 scopus 로고    scopus 로고
    • Performance of the partial CO 2 rebreathing technique under different hemodynamic and ventilation/perfusion matching conditions
    • Gama de Abreu M, Winkler T, Pahlitzsch T, Weismann D, Albrecht DM: Performance of the partial CO 2 rebreathing technique under different hemodynamic and ventilation/perfusion matching conditions. Crit Care Med 2003; 31: 543-551.
    • (2003) Crit Care Med , vol.31 , pp. 543-551
    • Gama De Abreu, M.1    Winkler, T.2    Pahlitzsch, T.3    Weismann, D.4    Albrecht, D.M.5
  • 11
    • 0037381750 scopus 로고    scopus 로고
    • Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present
    • Tachibana K, Imanaka H, Takeuchi M, Takauchi Y, Miyano H, Nishimura M: Noninvasive cardiac output measurement using partial carbon dioxide rebreathing is less accurate at settings of reduced minute ventilation and when spontaneous breathing is present. Anesthesiology 2003; 98: 830-837.
    • (2003) Anesthesiology , vol.98 , pp. 830-837
    • Tachibana, K.1    Imanaka, H.2    Takeuchi, M.3    Takauchi, Y.4    Miyano, H.5    Nishimura, M.6
  • 12
    • 0036140016 scopus 로고    scopus 로고
    • Effect of ventilatory settings on accuracy of cardiac output measurement using partial CO 2 - Rebreathing
    • Tachibana K, Imanaka H, Miyano H, Takeuchi M, Kumon K, Nishimura M: Effect of ventilatory settings on accuracy of cardiac output measurement using partial CO 2 - Rebreathing. Anesthesiology 2002; 96: 96-102.
    • (2002) Anesthesiology , vol.96 , pp. 96-102
    • Tachibana, K.1    Imanaka, H.2    Miyano, H.3    Takeuchi, M.4    Kumon, K.5    Nishimura, M.6
  • 13
    • 0742287108 scopus 로고    scopus 로고
    • A comparative evaluation of thermodilution and partial CO 2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation
    • Rocco M, Spadetta G, Morelli A, Dell'Utri D, Porzi P, Conti G, Pietropaoli P: A comparative evaluation of thermodilution and partial CO 2 rebreathing techniques for cardiac output assessment in critically ill patients during assisted ventilation. Intensive Care Med 2004; 30: 82-87.
    • (2004) Intensive Care Med , vol.30 , pp. 82-87
    • Rocco, M.1    Spadetta, G.2    Morelli, A.3    Dell'Utri, D.4    Porzi, P.5    Conti, G.6    Pietropaoli, P.7
  • 14
    • 0036676068 scopus 로고    scopus 로고
    • Partial CO 2 rebreathing technique versus thermodilution: Measurement of cardiac output before and after operations with extracorporeal circulation (in German)
    • Neuhauser C, Muller M, Brau M, Scholz S, Boning O, Roth P, Hempelmann G: Partial CO 2 rebreathing technique versus thermodilution: measurement of cardiac output before and after operations with extracorporeal circulation (in German). Anaesthesist 2002; 51: 625-633.
    • (2002) Anaesthesist , vol.51 , pp. 625-633
    • Neuhauser, C.1    Muller, M.2    Brau, M.3    Scholz, S.4    Boning, O.5    Roth, P.6    Hempelmann, G.7
  • 15
    • 0028227989 scopus 로고
    • A modified photo- and magnetoacoustic multigas analyzer applied in gas exchange measurements
    • Clemensen P, Christensen P, Norsk P, Gronlund J: A modified photo- and magnetoacoustic multigas analyzer applied in gas exchange measurements. J Appl Physiol 1994; 76: 2832-2839.
    • (1994) J Appl Physiol , vol.76 , pp. 2832-2839
    • Clemensen, P.1    Christensen, P.2    Norsk, P.3    Gronlund, J.4
  • 16
    • 27444433897 scopus 로고    scopus 로고
    • Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: A new tool for heart failure evaluation
    • Agostoni P, Cattadori G, Apostolo A, Contini M, Palermo P, Marenzi G, Wasserman K: Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: a new tool for heart failure evaluation. J Am Coll Cardiol 2005; 46: 1779-1781.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1779-1781
    • Agostoni, P.1    Cattadori, G.2    Apostolo, A.3    Contini, M.4    Palermo, P.5    Marenzi, G.6    Wasserman, K.7
  • 17
    • 33846428444 scopus 로고    scopus 로고
    • Ease of noninvasive measurement of cardiac output coupled with peak v O 2 determination at rest and during exercise in patients with heart failure
    • Lang CC, Karlin P, Haythe J, Tsao L, Mancini DM: Ease of noninvasive measurement of cardiac output coupled with peak V O 2 determination at rest and during exercise in patients with heart failure. Am J Cardiol 2007; 99: 404-405.
    • (2007) Am J Cardiol , vol.99 , pp. 404-405
    • Lang, C.C.1    Karlin, P.2    Haythe, J.3    Tsao, L.4    Mancini, D.M.5
  • 18
    • 33644797321 scopus 로고    scopus 로고
    • Validation of the use of foreign gas rebreathing method for noninvasive determination of cardiac output in heart disease patients
    • Dong L, Wang JA, Jiang CY: Validation of the use of foreign gas rebreathing method for noninvasive determination of cardiac output in heart disease patients. J Zhejiang Univ Sci B 2005; 6: 1157-1162.
    • (2005) J Zhejiang Univ Sci B , vol.6 , pp. 1157-1162
    • Dong, L.1    Wang, J.A.2    Jiang, C.Y.3
  • 19
    • 0141749277 scopus 로고    scopus 로고
    • Noninvasive determination of cardiac output in ventilated patients. Clinical evaluation of a simplified quick method (in German)
    • Reutershan J, Kapp T, Unertl K, Fretschner R: Noninvasive determination of cardiac output in ventilated patients. Clinical evaluation of a simplified quick method (in German). Anaesthesist 2003; 52: 778-786.
    • (2003) Anaesthesist , vol.52 , pp. 778-786
    • Reutershan, J.1    Kapp, T.2    Unertl, K.3    Fretschner, R.4
  • 20
    • 0033974708 scopus 로고    scopus 로고
    • Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow
    • Christensen P, Clemensen P, Andersen PK, Henneberg SW: Thermodilution versus inert gas rebreathing for estimation of effective pulmonary blood flow. Crit Care Med 2000; 28: 51-56.
    • (2000) Crit Care Med , vol.28 , pp. 51-56
    • Christensen, P.1    Clemensen, P.2    Andersen, P.K.3    Henneberg, S.W.4
  • 21
    • 18244361864 scopus 로고    scopus 로고
    • Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique
    • Gabrielsen A, Videbaek R, Schou M, Damgaard M, Kastrup J, Norsk P: Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique. Clin Sci (Lond) 2002; 102: 247-252.
    • (2002) Clin Sci (Lond) , vol.102 , pp. 247-252
    • Gabrielsen, A.1    Videbaek, R.2    Schou, M.3    Damgaard, M.4    Kastrup, J.5    Norsk, P.6
  • 22
    • 0020445597 scopus 로고
    • Reliability of the thermodilution method in the determination of cardiac output in clinical practice
    • Stetz CW, Miller RG, Kelly GE, Raffin TA: Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis 1982; 126: 1001-1004.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 1001-1004
    • Stetz, C.W.1    Miller, R.G.2    Kelly, G.E.3    Raffin, T.A.4
  • 24
    • 20344403100 scopus 로고    scopus 로고
    • Effects of ventilation on cardiac output determined by inert gas rebreathing
    • Damgaard M, Norsk P: Effects of ventilation on cardiac output determined by inert gas rebreathing. Clin Physiol Funct Imaging 2005; 25: 142-147.
    • (2005) Clin Physiol Funct Imaging , vol.25 , pp. 142-147
    • Damgaard, M.1    Norsk, P.2
  • 26
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 27
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • Critchley LA, Critchley JA: A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999; 15: 85-91.
    • (1999) J Clin Monit Comput , vol.15 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 29
    • 0034963214 scopus 로고    scopus 로고
    • Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output
    • Nilsson LB, Eldrup N, Berthelsen PG: Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output. Acta Anaesthesiol Scand 2001; 45: 680-685.
    • (2001) Acta Anaesthesiol Scand , vol.45 , pp. 680-685
    • Nilsson, L.B.1    Eldrup, N.2    Berthelsen, P.G.3
  • 30
    • 20944450900 scopus 로고    scopus 로고
    • Agreement of an inert gas rebreathing device with thermodilution and the direct oxygen Fick method in measurement of pulmonary blood flow
    • Peyton PJ, Thompson B: Agreement of an inert gas rebreathing device with thermodilution and the direct oxygen Fick method in measurement of pulmonary blood flow. J Clin Monit Comput 2004; 18: 373-378.
    • (2004) J Clin Monit Comput , vol.18 , pp. 373-378
    • Peyton, P.J.1    Thompson, B.2
  • 31
    • 0036385496 scopus 로고    scopus 로고
    • Lack of agreement between thermodilution and Fick cardiac output in critically ill patients
    • Dhingra VK, Fenwick JC, Walley KR, Chittock DR, Ronco JJ: Lack of agreement between thermodilution and Fick cardiac output in critically ill patients. Chest 2002; 122: 990-997.
    • (2002) Chest , vol.122 , pp. 990-997
    • Dhingra, V.K.1    Fenwick, J.C.2    Walley, K.R.3    Chittock, D.R.4    Ronco, J.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.