메뉴 건너뛰기




Volumn 80, Issue 4, 2005, Pages 1479-1483

Non-invasive cardiac output determination by two-dimensional independent Doppler during and after cardiac surgery

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DOPPLER ECHOCARDIOGRAPHY; HEART MUSCLE REVASCULARIZATION; HEART OUTPUT; HEART RIGHT VENTRICLE OUTFLOW TRACT; HEART STROKE VOLUME; HEART SURGERY; HUMAN; INTRAOPERATIVE PERIOD; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; SWAN GANZ CATHETER; ULTRASOUND;

EID: 25144520471     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2004.12.034     Document Type: Article
Times cited : (66)

References (10)
  • 2
    • 0025685462 scopus 로고
    • Pulmonary artery catheter study group: A multicenter study of physicians' knowledge of the pulmonary artery catheter
    • T.J. Iberti, E.P. Fischer, A.B. Leibowitz, E.A. Panacek, J.H. Silverstein, T.E. Albertson Pulmonary artery catheter study group a multicenter study of physicians' knowledge of the pulmonary artery catheter JAMA 264 1990 2928 2932
    • (1990) JAMA , vol.264 , pp. 2928-2932
    • Iberti, T.J.1    Fischer, E.P.2    Leibowitz, A.B.3    Panacek, E.A.4    Silverstein, J.H.5    Albertson, T.E.6
  • 3
    • 0036481560 scopus 로고    scopus 로고
    • Recommendations for quantification of Doppler echocardiography: A report from the Doppler quantification task force of the nomenclature and standards committee of the American Society of echocardiography
    • C.M. Otto, M. Stoddard, A. Waggoner, W.A. Zoghbi Recommendations for quantification of Doppler echocardiography a report from the Doppler quantification task force of the nomenclature and standards committee of the American Society of echocardiography J Am Soc Echocardiogr 15 2002 167 184
    • (2002) J Am Soc Echocardiogr , vol.15 , pp. 167-184
    • Otto, C.M.1    Stoddard, M.2    Waggoner, A.3    Zoghbi, W.A.4
  • 4
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • L.A.H. Critchley, J.A.J.H. Critchley A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques J Clin Monit 15 1999 85 91
    • (1999) J Clin Monit , vol.15 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2
  • 6
    • 0036219991 scopus 로고    scopus 로고
    • Stroke volume variation for assessment of cardiac responsiveness to volume overloading in mechanically ventilated patients after cardiac surgery
    • D.A. Reuter, T.W. Felbinger, C. Schmidt, E. Kilger, O. Goedje, P. Lamm, A.E. Goetz Stroke volume variation for assessment of cardiac responsiveness to volume overloading in mechanically ventilated patients after cardiac surgery Intensive Care Med 28 2002 392 398
    • (2002) Intensive Care Med , vol.28 , pp. 392-398
    • Reuter, D.A.1    Felbinger, T.W.2    Schmidt, C.3    Kilger, E.4    Goedje, O.5    Lamm, P.6    Goetz, A.E.7
  • 7
    • 0035092478 scopus 로고    scopus 로고
    • Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock
    • M. Feissel, F. Michard, I. Mangin, O. Ruyer, J.P. Faller, J.T. Teboul Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock Chest 119 2001 867 873
    • (2001) Chest , vol.119 , pp. 867-873
    • Feissel, M.1    Michard, F.2    Mangin, I.3    Ruyer, O.4    Faller, J.P.5    Teboul, J.T.6
  • 9
    • 0027377406 scopus 로고
    • Reliability of a new generation transesophageal Doppler device for cardiac output monitoring
    • E.R. Schmid, D.R. Spahn, M. Tornic Reliability of a new generation transesophageal Doppler device for cardiac output monitoring Anesth Analg 77 1993 971 979
    • (1993) Anesth Analg , vol.77 , pp. 971-979
    • Schmid, E.R.1    Spahn, D.R.2    Tornic, M.3
  • 10
    • 0023258950 scopus 로고
    • Reproducibility of cardiac stroke volume estimated by Doppler echocardiography
    • H. Ihlen, K. Endersen, Y. Myreng, E. Myre Reproducibility of cardiac stroke volume estimated by Doppler echocardiography Am J Cardiol 59 1987 957 958
    • (1987) Am J Cardiol , vol.59 , pp. 957-958
    • Ihlen, H.1    Endersen, K.2    Myreng, Y.3    Myre, E.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.