메뉴 건너뛰기




Volumn 10, Issue 2, 2013, Pages 185-199

Percutaneous transcatheter aortic valve implantation: Present and future perspective

Author keywords

aortic stenosis; CoreValve ; Edwards SAPIEN XT ; PARTNER trial; transcatheter aortic valve implantation

Indexed keywords

AORTIC STENOSIS; BALLOON DILATATION; FUTURE PERSPECTIVES; PARTNER TRIAL; SHAPE-MEMORY MATERIALS; STANDARD OF CARES; THIRD GENERATION; TRANSCATHETER AORTIC VALVES;

EID: 84874874083     PISSN: 17434440     EISSN: 17452422     Source Type: Journal    
DOI: 10.1586/erd.12.78     Document Type: Review
Times cited : (7)

References (101)
  • 1
    • 84863337787 scopus 로고    scopus 로고
    • 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement
    • Holmes DR Jr, Mack MJ, Kaul S et al. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. J. Am. Coll. Cardiol. 59(13), 1200-1254 (2012).
    • (2012) J. Am. Coll. Cardiol. , vol.59 , Issue.13 , pp. 1200-1254
    • Holmes Jr., D.R.1    Mack, M.J.2    Kaul, S.3
  • 2
    • 33747116680 scopus 로고    scopus 로고
    • ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines
    • (writing committee to revise the 1998 Guidelines for the Management of Patients with Valvular Heart Disease): Developed in collaboration with the Society of Cardiovascular Anesthesiologists: Endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons
    • Bonow RO, Carabello BA, Kanu C et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (writing committee to revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): developed in collaboration with the Society of Cardiovascular Anesthesiologists: endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. Circulation 114(5), e84-231 (2006).
    • (2006) Circulation , vol.114 , Issue.5
    • Bonow, R.O.1    Carabello, B.A.2    Kanu, C.3
  • 3
    • 0038267070 scopus 로고    scopus 로고
    • A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease
    • Iung B, Baron G, Butchart EG et al. A prospective survey of patients with valvular heart disease in Europe: The Euro Heart Survey on Valvular Heart Disease. Eur. Heart J. 24(13), 1231-1243 (2003).
    • (2003) Eur. Heart J. , vol.24 , Issue.13 , pp. 1231-1243
    • Iung, B.1    Baron, G.2    Butchart, E.G.3
  • 4
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • Cribier A, Eltchaninoff H, Bash A et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 106(24), 3006-3008 (2002).
    • (2002) Circulation , vol.106 , Issue.24 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 5
    • 84874824282 scopus 로고    scopus 로고
    • Learning from the cases of TAVI
    • London, UK, 20-22 September
    • Kim W-J. Learning from the cases of TAVI. Presented at: IPS Congress, London, UK, 20-22 September 2010.
    • (2010) Presented At: IPS Congress
    • Kim, W.-J.1
  • 6
    • 83655184726 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Current and future approaches
    • Rodés-Cabau J. Transcatheter aortic valve implantation: current and future approaches. Nat. Rev. Cardiol. 9(1), 15-29 (2012).
    • (2012) Nat. Rev. Cardiol. , vol.9 , Issue.1 , pp. 15-29
    • Rodés-Cabau, J.1
  • 7
    • 0042859863 scopus 로고    scopus 로고
    • Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    • Blais C, Dumesnil JG, Baillot R, Simard S, Doyle D, Pibarot P. Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement. Circulation 108(8), 983-988 (2003).
    • (2003) Circulation , vol.108 , Issue.8 , pp. 983-988
    • Blais, C.1    Dumesnil, J.G.2    Baillot, R.3    Simard, S.4    Doyle, D.5    Pibarot, P.6
  • 8
    • 84874654878 scopus 로고    scopus 로고
    • Early and late improvement of global and regional left ventricular function after transcatheter aortic valve implantation in patients with severe aortic stenosis: An echocardiographic study
    • Giannini C, Petronio AS, Talini E et al. Early and late improvement of global and regional left ventricular function after transcatheter aortic valve implantation in patients with severe aortic stenosis: an echocardiographic study. Am. J. Cardiovasc. Dis. 1(3), 264-273 (2011).
    • (2011) Am. J. Cardiovasc. Dis. , vol.1 , Issue.3 , pp. 264-273
    • Giannini, C.1    Petronio, A.S.2    Talini, E.3
  • 9
    • 84859445235 scopus 로고    scopus 로고
    • First-in-man transcatheter aortic valve implantation of a 20-mm Edwards SAPIEN XT valve: One step forward for the treatment of patients with severe aortic stenosis and small aortic annulus
    • Rodés-Cabau J, DeLarochellière R, Dumont E. First-in-man transcatheter aortic valve implantation of a 20-mm Edwards SAPIEN XT valve: one step forward for the treatment of patients with severe aortic stenosis and small aortic annulus. Catheter. Cardiovasc. Interv. 79(5), 789-793 (2012).
    • (2012) Catheter. Cardiovasc. Interv. , vol.79 , Issue.5 , pp. 789-793
    • Rodés-Cabau, J.1    Delarochellière, R.2    Dumont, E.3
  • 10
    • 77952312586 scopus 로고    scopus 로고
    • Improved technique of transapical aortic valve implantation: 'The Berlin addition'
    • Pasic M, Dreysse S, Drews T et al. Improved technique of transapical aortic valve implantation: 'the Berlin addition'. Ann. Thorac. Surg. 89(6), 2058-2060 (2010).
    • (2010) Ann. Thorac. Surg. , vol.89 , Issue.6 , pp. 2058-2060
    • Pasic, M.1    Dreysse, S.2    Drews, T.3
  • 11
    • 84866396204 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation using the slow balloon inflation technique: Making balloonexpandable valves partially repositionable
    • Mok M, Dumont E, Doyle D, Rodés- Cabau J. Transcatheter aortic valve implantation using the slow balloon inflation technique: making balloonexpandable valves partially repositionable. J. Card. Surg. 27(5), 546-548 (2012).
    • (2012) J. Card. Surg. , vol.27 , Issue.5 , pp. 546-548
    • Mok, M.1    Dumont, E.2    Doyle, D.3    Rodés-Cabau, J.4
  • 12
    • 84859701154 scopus 로고    scopus 로고
    • Improved procedural results after CoreValve implantation with the new AccuTrak delivery system
    • Chorianopoulos E, Krumsdorf U, Pleger ST, Katus HA, Bekeredjian R. Improved procedural results after CoreValve implantation with the new AccuTrak delivery system. J. Interv. Cardiol. 25(2), 174-179 (2012).
    • (2012) J. Interv. Cardiol. , vol.25 , Issue.2 , pp. 174-179
    • Chorianopoulos, E.1    Krumsdorf, U.2    Pleger, S.T.3    Katus, H.A.4    Bekeredjian, R.5
  • 13
    • 84872165848 scopus 로고    scopus 로고
    • Update on the need for a permanent pacemaker after transcatheter aortic valve implantation using the CoreValve® Accutrak™ system
    • Tchetche D, Modine T, Farah B et al. Update on the need for a permanent pacemaker after transcatheter aortic valve implantation using the CoreValve® Accutrak™ system. EuroIntervention 8(5), 556-562 (2012).
    • (2012) EuroIntervention , vol.8 , Issue.5 , pp. 556-562
    • Tchetche, D.1    Modine, T.2    Farah, B.3
  • 14
    • 65249147294 scopus 로고    scopus 로고
    • Role of multislice computed tomography in transcatheter aortic valve replacement
    • Wood DA, Tops LF, Mayo JR et al. Role of multislice computed tomography in transcatheter aortic valve replacement. Am. J. Cardiol. 103(9), 1295-1301 (2009).
    • (2009) Am. J. Cardiol. , vol.103 , Issue.9 , pp. 1295-1301
    • Wood, D.A.1    Tops, L.F.2    Mayo, J.R.3
  • 15
    • 78649427705 scopus 로고    scopus 로고
    • Optimal projection estimation for transcatheter aortic valve implantation based on contrastaortography: Validation of a Prototype Software
    • Tzikas A, Schultz C, Van Mieghem NM, de Jaegere PP, Serruys PW. Optimal projection estimation for transcatheter aortic valve implantation based on contrastaortography: validation of a Prototype Software. Catheter. Cardiovasc. Interv. 76(4), 602-607 (2010).
    • (2010) Catheter. Cardiovasc. Interv. , vol.76 , Issue.4 , pp. 602-607
    • Tzikas, A.1    Schultz, C.2    Van Mieghem, N.M.3    De Jaegere, P.P.4    Serruys, P.W.5
  • 16
    • 77954515516 scopus 로고    scopus 로고
    • Percutaneous aortic valve implantation using novel imaging guidance
    • Dvir D, Kornowski R. Percutaneous aortic valve implantation using novel imaging guidance. Catheter. Cardiovasc. Interv. 76(3), 450-454 (2010).
    • (2010) Catheter. Cardiovasc. Interv. , vol.76 , Issue.3 , pp. 450-454
    • Dvir, D.1    Kornowski, R.2
  • 17
    • 80255137247 scopus 로고    scopus 로고
    • Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: The UK TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry
    • Moat NE, Ludman P, de Belder MA et al. Long-term outcomes after transcatheter aortic valve implantation in high-risk patients with severe aortic stenosis: the UK TAVI (United Kingdom Transcatheter Aortic Valve Implantation) Registry. J. Am. Coll. Cardiol. 58(20), 2130-2138 (2011).
    • (2011) J. Am. Coll. Cardiol. , vol.58 , Issue.20 , pp. 2130-2138
    • Moat, N.E.1    Ludman, P.2    De Belder, M.A.3
  • 18
    • 84860436228 scopus 로고    scopus 로고
    • FRANCE 2 Investigators. Registry of transcatheter aortic-valve implantation in high-risk patients
    • Gilard M, Eltchaninoff H, Iung B et al. FRANCE 2 Investigators. Registry of transcatheter aortic-valve implantation in high-risk patients. N. Engl. J. Med. 366(18), 1705-1715 (2012).
    • (2012) N. Engl. J. Med. , vol.366 , Issue.18 , pp. 1705-1715
    • Gilard, M.1    Eltchaninoff, H.2    Iung, B.3
  • 19
    • 84858793217 scopus 로고    scopus 로고
    • Rfsti CoreValve Italian Registry Investigators. Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis
    • Ussia GP, Barbanti M, Petronio AS et al. CoreValve Italian Registry Investigators. Transcatheter aortic valve implantation: 3-year outcomes of self-expanding CoreValve prosthesis. Eur. Heart J. 33(8), 969-976 (2012).
    • (2012) Eur. Heart J. , vol.33 , Issue.8 , pp. 969-976
    • Ussia, G.P.1    Barbanti, M.2    Petronio, A.S.3
  • 20
    • 79956206865 scopus 로고    scopus 로고
    • Belgian TAVI Registry Participants. Procedural, 30-day and one year outcome following CoreValve or Edwards transcatheter aortic valve implantation: Results of the Belgian national registry
    • Bosmans JM, Kefer J, De Bruyne B et al. Belgian TAVI Registry Participants. Procedural, 30-day and one year outcome following CoreValve or Edwards transcatheter aortic valve implantation: results of the Belgian national registry. Interact. Cardiovasc. Thorac. Surg. 12(5), 762-767 (2011).
    • (2011) Interact. Cardiovasc. Thorac. Surg. , vol.12 , Issue.5 , pp. 762-767
    • Bosmans, J.M.1    Kefer, J.2    De Bruyne, B.3
  • 21
    • 42249087162 scopus 로고    scopus 로고
    • Percutaneous implantation of the first repositionable aortic valve prosthesis in a patient with severe aortic stenosis
    • Buellesfeld L, Gerckens U, Grube E. Percutaneous implantation of the first repositionable aortic valve prosthesis in a patient with severe aortic stenosis. Catheter. Cardiovasc. Interv. 71(5), 579-584 (2008).
    • (2008) Catheter. Cardiovasc. Interv. , vol.71 , Issue.5 , pp. 579-584
    • Buellesfeld, L.1    Gerckens, U.2    Grube, E.3
  • 22
    • 79953697405 scopus 로고    scopus 로고
    • Transapical aortic valve implantation with a self-expanding anatomically oriented valve
    • Falk V, Walther T, Schwammenthal E et al. Transapical aortic valve implantation with a self-expanding anatomically oriented valve. Eur. Heart J. 32(7), 878-887 (2011).
    • (2011) Eur. Heart J. , vol.32 , Issue.7 , pp. 878-887
    • Falk, V.1    Walther, T.2    Schwammenthal, E.3
  • 23
    • 80053967878 scopus 로고    scopus 로고
    • Trans-apical aortic valve implantation using a new self-expandable bioprosthesis: Initial outcomes
    • Kempfert J, Rastan AJ, Beyersdorf F et al. Trans-apical aortic valve implantation using a new self-expandable bioprosthesis: initial outcomes. Eur. J. Cardiothorac. Surg. 40(5), 1114-1119 (2011).
    • (2011) Eur. J. Cardiothorac. Surg. , vol.40 , Issue.5 , pp. 1114-1119
    • Kempfert, J.1    Rastan, A.J.2    Beyersdorf, F.3
  • 24
    • 79960921321 scopus 로고    scopus 로고
    • A new self-expanding transcatheter aortic valve for transapical implantation - First in man implantation of the JenaValve ™
    • Kempfert J, Rastan AJ, Mohr FW, Walther T. A new self-expanding transcatheter aortic valve for transapical implantation - first in man implantation of the JenaValve ™. Eur. J. Cardiothorac. Surg. 40(3), 761-763 (2011).
    • (2011) Eur. J. Cardiothorac. Surg. , vol.40 , Issue.3 , pp. 761-763
    • Kempfert, J.1    Rastan, A.J.2    Mohr, F.W.3    Walther, T.4
  • 25
    • 84865348112 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation using the JenaValve™ system: Acute and 30-day results of the multicentre CE-mark study
    • Treede H, Mohr FW, Baldus S et al. Transapical transcatheter aortic valve implantation using the JenaValve™ system: acute and 30-day results of the multicentre CE-mark study. Eur. J. Cardiothorac. Surg. 41(6), e131-e138 (2012).
    • (2012) Eur. J. Cardiothorac. Surg. , vol.41 , Issue.6
    • Treede, H.1    Mohr, F.W.2    Baldus, S.3
  • 26
    • 84864707358 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement with the St. Jude Medical Portico valve: First-in-human experience
    • Willson AB, Rodès-Cabau J, Wood DA et al. Transcatheter aortic valve replacement with the St. Jude Medical Portico valve: first-in-human experience. J. Am. Coll. Cardiol. 60(7), 581-586 (2012).
    • (2012) J. Am. Coll. Cardiol. , vol.60 , Issue.7 , pp. 581-586
    • Willson, A.B.1    Rodès-Cabau, J.2    Wood, D.A.3
  • 27
    • 58749090760 scopus 로고    scopus 로고
    • Retrograde transarterial implantation of a nonmetallic aortic valve prosthesis in high-surgical-risk patients with severe aortic stenosis: A first-in-man feasibility and safety study
    • Schofer J, Schlüter M, Treede H et al. Retrograde transarterial implantation of a nonmetallic aortic valve prosthesis in high-surgical-risk patients with severe aortic stenosis: a first-in-man feasibility and safety study. Circ. Cardiovasc. Interv. 1(2), 126-133 (2008).
    • (2008) Circ. Cardiovasc. Interv. , vol.1 , Issue.2 , pp. 126-133
    • Schofer, J.1    Schlüter, M.2    Treede, H.3
  • 28
    • 77956212922 scopus 로고    scopus 로고
    • Six-month results of a repositionable and retrievable pericardial valve for transcatheter aortic valve replacement: The direct flow medical aortic valve
    • Treede H, Tübler T, Reichenspurner H et al. Six-month results of a repositionable and retrievable pericardial valve for transcatheter aortic valve replacement: the direct flow medical aortic valve. J. Thorac. Cardiovasc. Surg. 140(4), 897-903 (2010).
    • (2010) J. Thorac. Cardiovasc. Surg. , vol.140 , Issue.4 , pp. 897-903
    • Treede, H.1    Tübler, T.2    Reichenspurner, H.3
  • 29
    • 78649953307 scopus 로고    scopus 로고
    • Transapical aortic valve implantation: Results of a Brazilian prosthesis
    • Gaia DF, Palma JH, Ferreira CB et al. Transapical aortic valve implantation: results of a Brazilian prosthesis. Rev. Bras. Cir. Cardiovasc. 25(3), 293-302 (2010).
    • (2010) Rev. Bras. Cir. Cardiovasc. , vol.25 , Issue.3 , pp. 293-302
    • Gaia, D.F.1    Palma, J.H.2    Ferreira, C.B.3
  • 30
    • 81355154220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Results of the current development and implantation of a new Brazilian prosthesis
    • Gaia DF, Palma JH, Ferreira CB et al. Transcatheter aortic valve implantation: results of the current development and implantation of a new Brazilian prosthesis. Rev. Bras. Cir. Cardiovasc. 26(3), 338-347 (2011).
    • (2011) Rev. Bras. Cir. Cardiovasc. , vol.26 , Issue.3 , pp. 338-347
    • Gaia, D.F.1    Palma, J.H.2    Ferreira, C.B.3
  • 31
    • 42449157246 scopus 로고    scopus 로고
    • Smart materials applications for pediatric cardiovascular devices
    • Levi DS, Kusnezov N, Carman GP. Smart materials applications for pediatric cardiovascular devices. Pediatr. Res. 63(5), 552-558 (2008).
    • (2008) Pediatr. Res. , vol.63 , Issue.5 , pp. 552-558
    • Levi, D.S.1    Kusnezov, N.2    Carman, G.P.3
  • 32
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • PARTNER Trial Investigators
    • Leon MB, Smith CR, Mack M et al. PARTNER Trial Investigators. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N. Engl. J. Med. 363(17), 1597-1607 (2010).
    • (2010) N. Engl. J. Med. , vol.363 , Issue.17 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 33
    • 84860494889 scopus 로고    scopus 로고
    • Transcatheter aortic-valve replacement for inoperable severe aortic stenosis
    • PARTNER Trial Investigators
    • Makkar RR, Fontana GP, Jilaihawi H et al. PARTNER Trial Investigators. Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. N. Engl. J. Med. 366(18), 1696-1704 (2012).
    • (2012) N. Engl. J. Med. , vol.366 , Issue.18 , pp. 1696-1704
    • Makkar, R.R.1    Fontana, G.P.2    Jilaihawi, H.3
  • 34
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • PARTNER Trial Investigators
    • Smith CR, Leon MB, Mack MJ et al. PARTNER Trial Investigators. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N. Engl. J. Med. 364(23), 2187-2198 (2011).
    • (2011) N. Engl. J. Med. , vol.364 , Issue.23 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 35
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • PARTNER Trial Investigators
    • Kodali SK, Williams MR, Smith CR et al. PARTNER Trial Investigators. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N. Engl. J. Med. 366(18), 1686-1695 (2012).
    • (2012) N. Engl. J. Med. , vol.366 , Issue.18 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 36
    • 84857884549 scopus 로고    scopus 로고
    • Cost-effectiveness of transcatheter aortic valve replacement
    • Hlatky MA, Simons CT. Cost-effectiveness of transcatheter aortic valve replacement. Circulation 125(9), 1076-1077 (2012).
    • (2012) Circulation , vol.125 , Issue.9 , pp. 1076-1077
    • Hlatky, M.A.1    Simons, C.T.2
  • 37
    • 80055111953 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Lessons from the learning curve of the first high-risk patients
    • Gurvitch R, Tay EL, Wijesinghe N et al. Transcatheter aortic valve implantation: lessons from the learning curve of the first high-risk patients. Catheter. Cardiovasc. Interv. 78(7), 977-984 (2011)
    • (2011) Catheter. Cardiovasc. Interv. , vol.78 , Issue.7 , pp. 977-984
    • Gurvitch, R.1    Tay, E.L.2    Wijesinghe, N.3
  • 38
    • 78651489907 scopus 로고    scopus 로고
    • Standardized end point definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • Leon MB, Piazza N, Nikolsky E et al. Standardized end point definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium. Eur. Heart J. 32(2), 205-217 (2011).
    • (2011) Eur. Heart J. , vol.32 , Issue.2 , pp. 205-217
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 39
    • 84893345659 scopus 로고    scopus 로고
    • 30 Day outcome from the SOURCE XT TAVI post-approval Study
    • Paris, France, 15-18 May
    • Wendler O. 30 Day outcome from the SOURCE XT TAVI post-approval Study. Presented at: EuroPCR. Paris, France, 15-18 May (2012).
    • (2012) Presented At: EuroPCR
    • Wendler, O.1
  • 40
    • 78651506594 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: First results from a multi-centre real-world registry
    • German Transcatheter Aortic Valve Interventions-Registry Investigators
    • Zahn R, Gerckens U, Grube E et al. German Transcatheter Aortic Valve Interventions-Registry Investigators. Transcatheter aortic valve implantation: first results from a multi-centre real-world registry. Eur. Heart J. 32(2), 198-204 (2011).
    • (2011) Eur. Heart J. , vol.32 , Issue.2 , pp. 198-204
    • Zahn, R.1    Gerckens, U.2    Grube, E.3
  • 41
    • 78651520483 scopus 로고    scopus 로고
    • Group. One year follow-up of the multi-centre European PARTNER transcatheter heart valve study
    • PARTNER EU Investigator
    • Lefèvre T, Kappetein AP, Wolner E et al. PARTNER EU Investigator Group. One year follow-up of the multi-centre European PARTNER transcatheter heart valve study. Eur. Heart J. 32(2), 148-157 (2011).
    • (2011) Eur. Heart J. , vol.32 , Issue.2 , pp. 148-157
    • Lefèvre, T.1    Kappetein, A.P.2    Wolner, E.3
  • 42
    • 78651469380 scopus 로고    scopus 로고
    • FRANCE Registry Investigators Transcatheter aortic valve implantation: Early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry
    • Eltchaninoff H, Prat A, Gilard M et al. FRANCE Registry Investigators. Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry. Eur. Heart J. 32(2), 191-197 (2011).
    • (2011) Eur. Heart J. , vol.32 , Issue.2 , pp. 191-197
    • Eltchaninoff, H.1    Prat, A.2    Gilard, M.3
  • 43
    • 79961022681 scopus 로고    scopus 로고
    • One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: The European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • Thomas M, Schymik G, Walther T et al. One-year outcomes of cohort 1 in the Edwards SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) registry: the European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 124(4), 425-433 (2011).
    • (2011) Circulation , vol.124 , Issue.4 , pp. 425-433
    • Thomas, M.1    Schymik, G.2    Walther, T.3
  • 44
    • 77649113087 scopus 로고    scopus 로고
    • Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: A diffusion-weighted magnetic resonance imaging study
    • Kahlert P, Knipp SC, Schlamann M et al. Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study. Circulation 121(7), 870-878 (2010).
    • (2010) Circulation , vol.121 , Issue.7 , pp. 870-878
    • Kahlert, P.1    Knipp, S.C.2    Schlamann, M.3
  • 45
    • 77949918630 scopus 로고    scopus 로고
    • Risk and fate of cerebral embolism after transfemoral aortic valve implantation: A prospective pilot study with diffusionweighted magnetic resonance imaging
    • Ghanem A, Müller A, Nähle CP et al. Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusionweighted magnetic resonance imaging. J. Am. Coll. Cardiol. 55(14), 1427-1432 (2010).
    • (2010) J. Am. Coll. Cardiol. , vol.55 , Issue.14 , pp. 1427-1432
    • Ghanem, A.1    Müller, A.2    Nähle, C.P.3
  • 46
    • 78650573226 scopus 로고    scopus 로고
    • Cerebral embolism following transcatheter aortic valve implantation: Comparison of transfemoral and transapical approaches
    • Rodés-Cabau J, Dumont E, Boone RH et al. Cerebral embolism following transcatheter aortic valve implantation: comparison of transfemoral and transapical approaches. J. Am. Coll. Cardiol. 57(1), 18-28 (2011).
    • (2011) J. Am. Coll. Cardiol. , vol.57 , Issue.1 , pp. 18-28
    • Rodés-Cabau, J.1    Dumont, E.2    Boone, R.H.3
  • 47
    • 78449237803 scopus 로고    scopus 로고
    • An embolic deflection device for aortic valve interventions
    • Nietlispach F, Wijesinghe N, Gurvitch R et al. An embolic deflection device for aortic valve interventions. JACC Cardiovasc. Interv. 3(11), 1133-1138 (2010).
    • (2010) JACC Cardiovasc. Interv. , vol.3 , Issue.11 , pp. 1133-1138
    • Nietlispach, F.1    Wijesinghe, N.2    Gurvitch, R.3
  • 48
    • 84860381197 scopus 로고    scopus 로고
    • First-in-man use of a novel embolic protection device for patients undergoing transcatheter aortic valve implantation
    • Naber CK, Ghanem A, Abizaid AA et al. First-in-man use of a novel embolic protection device for patients undergoing transcatheter aortic valve implantation. EuroIntervention 8(1), 43-50 (2012).
    • (2012) EuroIntervention , vol.8 , Issue.1 , pp. 43-50
    • Naber, C.K.1    Ghanem, A.2    Abizaid, A.A.3
  • 49
    • 84865452176 scopus 로고    scopus 로고
    • First-in-man experience with a new embolic deflection device in transcatheter aortic valve interventions
    • Onsea K, Agostoni P, Samim M et al. First-in-man experience with a new embolic deflection device in transcatheter aortic valve interventions. EuroIntervention 8(1), 51-56 (2012).
    • (2012) EuroIntervention , vol.8 , Issue.1 , pp. 51-56
    • Onsea, K.1    Agostoni, P.2    Samim, M.3
  • 50
    • 79955392949 scopus 로고    scopus 로고
    • Frequency, determinants, and prognostic effects of acute kidney injury and red blood cell transfusion in patients undergoing transcatheter aortic valve implantation
    • Nuis RJ, Van Mieghem NM, Tzikas A et al. Frequency, determinants, and prognostic effects of acute kidney injury and red blood cell transfusion in patients undergoing transcatheter aortic valve implantation. Catheter. Cardiovasc. Interv. 77(6), 881-889 (2011).
    • (2011) Catheter. Cardiovasc. Interv. , vol.77 , Issue.6 , pp. 881-889
    • Nuis, R.J.1    Van Mieghem, N.M.2    Tzikas, A.3
  • 51
    • 78449239621 scopus 로고    scopus 로고
    • Renal function as predictor of mortality in patients after percutaneous transcatheter aortic valve implantation
    • Sinning JM, Ghanem A, Steinhäuser H et al. Renal function as predictor of mortality in patients after percutaneous transcatheter aortic valve implantation. JACC. Cardiovasc. Interv. 3(11), 1141-1149 (2010).
    • (2010) JACC. Cardiovasc. Interv. , vol.3 , Issue.11 , pp. 1141-1149
    • Sinning, J.M.1    Ghanem, A.2    Steinhäuser, H.3
  • 52
    • 79953678960 scopus 로고    scopus 로고
    • Incidence and predictors of acute kidney injury in patients undergoing transcatheter aortic valve implantation
    • Elhmidi Y, Bleiziffer S, Piazza N et al. Incidence and predictors of acute kidney injury in patients undergoing transcatheter aortic valve implantation. Am. Heart J. 161(4), 735-739 (2011).
    • (2011) Am. Heart J. , vol.161 , Issue.4 , pp. 735-739
    • Elhmidi, Y.1    Bleiziffer, S.2    Piazza, N.3
  • 53
    • 84864724536 scopus 로고    scopus 로고
    • Left bundle-branch block induced by transcatheter aortic valve implantation increases risk of death
    • Houthuizen P, Van Garsse LA, Poels TT et al. Left bundle-branch block induced by transcatheter aortic valve implantation increases risk of death. Circulation 126(6), 720-728 (2012).
    • (2012) Circulation , vol.126 , Issue.6 , pp. 720-728
    • Houthuizen, P.1    Van Garsse, L.A.2    Poels, T.T.3
  • 54
    • 79951581461 scopus 로고    scopus 로고
    • Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation
    • Fraccaro C, Buja G, Tarantini G et al. Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation. Am. J. Cardiol. 107(5), 747-754 (2011).
    • (2011) Am. J. Cardiol. , vol.107 , Issue.5 , pp. 747-754
    • Fraccaro, C.1    Buja, G.2    Tarantini, G.3
  • 55
    • 79952738239 scopus 로고    scopus 로고
    • Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: Incidence and contributing factors (the UK CoreValve Collaborative)
    • Khawaja MZ, Rajani R, Cook A et al. Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: incidence and contributing factors (the UK CoreValve Collaborative). Circulation 123(9), 951-960 (2011).
    • (2011) Circulation , vol.123 , Issue.9 , pp. 951-960
    • Khawaja, M.Z.1    Rajani, R.2    Cook, A.3
  • 56
    • 84859631680 scopus 로고    scopus 로고
    • Management of acute left main obstruction after transcatheter aortic valve replacement: The tunnel technique
    • Fiorina C, Curello S, Maffeo D, Lorusso R, Chizzola G, Ettori F. Management of acute left main obstruction after transcatheter aortic valve replacement: the 'tunnel technique'. Cardiovasc. Revasc. Med. 13(2), 142.e5-142.e9 (2012).
    • (2012) Cardiovasc. Revasc. Med. , vol.13 , Issue.2
    • Fiorina, C.1    Curello, S.2    Maffeo, D.3    Lorusso, R.4    Chizzola, G.5    Ettori, F.6
  • 57
    • 72249096323 scopus 로고    scopus 로고
    • 'Valve-in-valve' for the treatment of paravalvular leaks following transcatheter aortic valve implantation
    • Rodés-Cabau J, Dumont E, Doyle D. 'Valve-in-valve' for the treatment of paravalvular leaks following transcatheter aortic valve implantation. Catheter. Cardiovasc. Interv. 74(7), 1116-1119 (2009).
    • (2009) Catheter. Cardiovasc. Interv. , vol.74 , Issue.7 , pp. 1116-1119
    • Rodés-Cabau, J.1    Dumont, E.2    Doyle, D.3
  • 58
    • 38349136447 scopus 로고    scopus 로고
    • Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults
    • Zegdi R, Ciobotaru V, Noghin M et al. Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults. J. Am. Coll. Cardiol. 51(5), 579-584 (2008).
    • (2008) J. Am. Coll. Cardiol. , vol.51 , Issue.5 , pp. 579-584
    • Zegdi, R.1    Ciobotaru, V.2    Noghin, M.3
  • 59
    • 68949174075 scopus 로고    scopus 로고
    • Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis
    • Schultz CJ, Weustink A, Piazza N et al. Geometry and degree of apposition of the CoreValve ReValving system with multislice computed tomography after implantation in patients with aortic stenosis. J. Am. Coll. Cardiol. 54(10), 911-918 (2009).
    • (2009) J. Am. Coll. Cardiol. , vol.54 , Issue.10 , pp. 911-918
    • Schultz, C.J.1    Weustink, A.2    Piazza, N.3
  • 60
    • 67650403808 scopus 로고    scopus 로고
    • Symptomatic paravalvular leakage after mechanical aortic valve replacement in a critically ill patient: Why not just 'plug' the hole?
    • Hammerstingl C, Werner N, Nickenig G. Symptomatic paravalvular leakage after mechanical aortic valve replacement in a critically ill patient: why not just 'plug' the hole? Eur. J. Echocardiogr. 10(4), 576-578 (2009).
    • (2009) Eur. J. Echocardiogr. , vol.10 , Issue.4 , pp. 576-578
    • Hammerstingl, C.1    Werner, N.2    Nickenig, G.3
  • 61
    • 34249995406 scopus 로고    scopus 로고
    • Percutaneous closure of perivalvular leaks with Amplatzer occluders: Feasibility, safety, and shortterm results
    • Shapira Y, Hirsch R, Kornowski R et al. Percutaneous closure of perivalvular leaks with Amplatzer occluders: feasibility, safety, and shortterm results. J. Heart Valve Dis. 16(3), 305-313 (2007).
    • (2007) J. Heart Valve Dis. , vol.16 , Issue.3 , pp. 305-313
    • Shapira, Y.1    Hirsch, R.2    Kornowski, R.3
  • 62
    • 84874928787 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for severe regurgitation in native and degenerated bioprosthetic aortic valves
    • doi:10.1002/ccd.24479 Epub ahead of print
    • Sarkar K, Sardella G, Romeo F et al. Transcatheter aortic valve implantation for severe regurgitation in native and degenerated bioprosthetic aortic valves. Catheter. Cardiovasc. Interv. doi:10.1002/ ccd.24479 (2012) (Epub ahead of print).
    • (2012) Catheter. Cardiovasc. Interv.
    • Sarkar, K.1    Sardella, G.2    Romeo, F.3
  • 63
    • 84871928282 scopus 로고    scopus 로고
    • Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access
    • Greif M, Lange P, Mair H et al. Transcatheter Edwards Sapien XT valve in valve implantation in degenerated aortic bioprostheses via transfemoral access. Clin. Res. Cardiol. 101(12), 993-1001 (2012).
    • (2012) Clin. Res. Cardiol. , vol.101 , Issue.12 , pp. 993-1001
    • Greif, M.1    Lange, P.2    Mair, H.3
  • 64
    • 79960392734 scopus 로고    scopus 로고
    • Transapical aortic valve implantation after previous aortic valve replacement: Clinical proof of the 'valve-in-valve' concept
    • Pasic M, Unbehaun A, Dreysse S et al. Transapical aortic valve implantation after previous aortic valve replacement: clinical proof of the 'valve-in-valve' concept. J. Thorac. Cardiovasc. Surg. 142(2), 270-277 (2011).
    • (2011) J. Thorac. Cardiovasc. Surg. , vol.142 , Issue.2 , pp. 270-277
    • Pasic, M.1    Unbehaun, A.2    Dreysse, S.3
  • 65
    • 79953835907 scopus 로고    scopus 로고
    • Correction of aortic regurgitation after transcatheter aortic valve implantation of the Medtronic CoreValve™ prosthesis due to a too-low implantation, using transcatheter repositioning
    • Zahn R, Schiele R, Kilkowski C et al. Correction of aortic regurgitation after transcatheter aortic valve implantation of the Medtronic CoreValve™ prosthesis due to a too-low implantation, using transcatheter repositioning. J. Heart Valve Dis. 20(1), 64-69 (2011).
    • (2011) J. Heart Valve Dis. , vol.20 , Issue.1 , pp. 64-69
    • Zahn, R.1    Schiele, R.2    Kilkowski, C.3
  • 66
    • 76749127080 scopus 로고    scopus 로고
    • Effect of concomitant coronary artery disease on procedural and late outcomes of transcatheter aortic valve implantation
    • discussion 767
    • Dewey TM, Brown DL, Herbert MA et al. Effect of concomitant coronary artery disease on procedural and late outcomes of transcatheter aortic valve implantation. Ann. Thorac. Surg. 89(3), 758-767; discussion 767 (2010).
    • (2010) Ann. Thorac. Surg. , vol.89 , Issue.3 , pp. 758-767
    • Dewey, T.M.1    Brown, D.L.2    Herbert, M.A.3
  • 67
    • 84856487608 scopus 로고    scopus 로고
    • Comparison of outcomes in patients having isolated transcatheter aortic valve implantation versus combined with preprocedural percutaneous coronary intervention
    • Abdel-Wahab M, Mostafa AE, Geist V et al. Comparison of outcomes in patients having isolated transcatheter aortic valve implantation versus combined with preprocedural percutaneous coronary intervention. Am. J. Cardiol. 109(4), 581-586 (2012).
    • (2012) Am. J. Cardiol. , vol.109 , Issue.4 , pp. 581-586
    • Abdel-Wahab, M.1    Mostafa, A.E.2    Geist, V.3
  • 68
    • 78549256704 scopus 로고    scopus 로고
    • Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction
    • Clavel MA, Webb JG, Rodés-Cabau J et al. Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction. Circulation 122(19), 1928-1936 (2010).
    • (2010) Circulation , vol.122 , Issue.19 , pp. 1928-1936
    • Clavel, M.A.1    Webb, J.G.2    Rodés-Cabau, J.3
  • 69
    • 84860258139 scopus 로고    scopus 로고
    • Impact of transcatheter aortic valve implantation with the CoreValve prosthesis in patients with severe aortic stenosis and left ventricular dysfunction
    • Muñoz-García AJ, Jiménez-Navarro MF, Rodríguez-Bailón I et al. Impact of transcatheter aortic valve implantation with the CoreValve prosthesis in patients with severe aortic stenosis and left ventricular dysfunction. Int. J. Cardiol. 157(1), 124-125 (2012).
    • (2012) Int. J. Cardiol. , vol.157 , Issue.1 , pp. 124-125
    • Muñoz-García, A.J.1    Jiménez-Navarro, M.F.2    Rodríguez-Bailón, I.3
  • 70
    • 84863437092 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve replacement in patients with cardiogenic shock
    • D'Ancona G, Pasic M, Buz S et al. Transapical transcatheter aortic valve replacement in patients with cardiogenic shock. Interact. Cardiovasc. Thorac. Surg. 14(4), 426-430 (2012).
    • (2012) Interact. Cardiovasc. Thorac. Surg. , vol.14 , Issue.4 , pp. 426-430
    • D'Ancona, G.1    Pasic, M.2    Buz, S.3
  • 71
    • 84865453807 scopus 로고    scopus 로고
    • Indication and structures and management of transcatheter aortic valve implantation: A review of the literature
    • Doebler K, Boukamp K, Mayer ED. Indication and structures and management of transcatheter aortic valve implantation: a review of the literature. Thorac. Cardiovasc. Surg. 60(5), 309-318 (2012).
    • (2012) Thorac. Cardiovasc. Surg. , vol.60 , Issue.5 , pp. 309-318
    • Doebler, K.1    Boukamp, K.2    Mayer, E.D.3
  • 72
    • 77957945557 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort
    • Gurvitch R, Wood DA, Tay EL et al. Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort. Circulation 122(13), 1319-1327 (2010).
    • (2010) Circulation , vol.122 , Issue.13 , pp. 1319-1327
    • Gurvitch, R.1    Wood, D.A.2    Tay, E.L.3
  • 73
    • 82555172331 scopus 로고    scopus 로고
    • Dual antiplatelet therapy versus aspirin alone in patients undergoing transcatheter aortic valve implantation
    • Ussia GP, Scarabelli M, Mulè M et al. Dual antiplatelet therapy versus aspirin alone in patients undergoing transcatheter aortic valve implantation. Am. J. Cardiol. 108(12), 1772-1776 (2011).
    • (2011) Am. J. Cardiol. , vol.108 , Issue.12 , pp. 1772-1776
    • Ussia, G.P.1    Scarabelli, M.2    Mulè, M.3
  • 74
    • 34748910153 scopus 로고    scopus 로고
    • Transapical minimally invasive aortic valve implantation: Multicenter experience
    • Walther T, Simon P, Dewey T et al. Transapical minimally invasive aortic valve implantation: multicenter experience. Circulation 116(11 Suppl.), I240-I245 (2007).
    • (2007) Circulation , vol.116 , Issue.11 SUPPL.
    • Walther, T.1    Simon, P.2    Dewey, T.3
  • 75
    • 79958151944 scopus 로고    scopus 로고
    • Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes
    • Wenaweser P, Pilgrim T, Roth N et al. Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes. Am. Heart J. 161(6), 1114-1124 (2011).
    • (2011) Am. Heart J. , vol.161 , Issue.6 , pp. 1114-1124
    • Wenaweser, P.1    Pilgrim, T.2    Roth, N.3
  • 76
    • 84856264422 scopus 로고    scopus 로고
    • Local versus general anesthesia for transfemoral aortic valve implantation
    • Motloch LJ, Rottlaender D, Reda S et al. Local versus general anesthesia for transfemoral aortic valve implantation. Clin. Res. Cardiol. 101(1), 45-53 (2012).
    • (2012) Clin. Res. Cardiol. , vol.101 , Issue.1 , pp. 45-53
    • Motloch, L.J.1    Rottlaender, D.2    Reda, S.3
  • 77
    • 77950447534 scopus 로고    scopus 로고
    • A new technique for vascular access management in transcatheter aortic valve implantation
    • Sharp AS, Michev I, Maisano F et al. A new technique for vascular access management in transcatheter aortic valve implantation. Catheter. Cardiovasc. Interv. 75(5), 784-793 (2010).
    • (2010) Catheter. Cardiovasc. Interv. , vol.75 , Issue.5 , pp. 784-793
    • Sharp, A.S.1    Michev, I.2    Maisano, F.3
  • 78
    • 79952535488 scopus 로고    scopus 로고
    • Percutaneous femoral artery access with Prostar device for innovative mitral and aortic interventions
    • Vergnat M, Finet G, Rioufol G, Obadia JF. Percutaneous femoral artery access with Prostar device for innovative mitral and aortic interventions. Eur. J. Cardiothorac. Surg. 39(4), 600-602 (2011).
    • (2011) Eur. J. Cardiothorac. Surg. , vol.39 , Issue.4 , pp. 600-602
    • Vergnat, M.1    Finet, G.2    Rioufol, G.3    Obadia, J.F.4
  • 79
    • 84857552892 scopus 로고    scopus 로고
    • True percutaneous approach for transfemoral aortic valve implantation using the Prostar XL device: Impact of learning curve on vascular complications
    • Hayashida K, Lefèvre T, Chevalier B et al. True percutaneous approach for transfemoral aortic valve implantation using the Prostar XL device: impact of learning curve on vascular complications. JACC Cardiovasc. Interv. 5(2), 207-214 (2012).
    • (2012) JACC Cardiovasc. Interv. , vol.5 , Issue.2 , pp. 207-214
    • Hayashida, K.1    Lefèvre, T.2    Chevalier, B.3
  • 80
    • 84859907083 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Surgical perspectives
    • Walther T, Kempfert J, Mohr FW. Transcatheter aortic valve implantation: surgical perspectives. Arch. Cardiovasc. Dis. 105(3), 174-180 (2012).
    • (2012) Arch. Cardiovasc. Dis. , vol.105 , Issue.3 , pp. 174-180
    • Walther, T.1    Kempfert, J.2    Mohr, F.W.3
  • 81
    • 77952781134 scopus 로고    scopus 로고
    • Transaortic transcatheter aortic valve implantation: A novel approach for the truly 'no-access option' patients
    • Latsios G, Gerckens U, Grube E. Transaortic transcatheter aortic valve implantation: a novel approach for the truly 'no-access option' patients. Catheter. Cardiovasc. Interv. 75(7), 1129-1136 (2010).
    • (2010) Catheter. Cardiovasc. Interv. , vol.75 , Issue.7 , pp. 1129-1136
    • Latsios, G.1    Gerckens, U.2    Grube, E.3
  • 82
    • 84859443978 scopus 로고    scopus 로고
    • Transaortic Transcatheter Aortic valve implantation using Edwards Sapien valve: A novel approach
    • Bapat V, Khawaja MZ, Attia R et al. Transaortic Transcatheter Aortic valve implantation using Edwards Sapien valve: a novel approach. Catheter. Cardiovasc. Interv. 79(5), 733-740 (2012).
    • (2012) Catheter. Cardiovasc. Interv. , vol.79 , Issue.5 , pp. 733-740
    • Bapat, V.1    Khawaja, M.Z.2    Attia, R.3
  • 83
    • 84863845878 scopus 로고    scopus 로고
    • Transaortic transcatheter aortic valve implantation: Potential issues associated with the use of the ASCENDRA transapical delivery system
    • Nombela-Franco L, Rodés-Cabau J, Doyle D et al. Transaortic transcatheter aortic valve implantation: potential issues associated with the use of the ASCENDRA transapical delivery system. J. Card. Surg. 27(4), 438-440 (2012).
    • (2012) J. Card. Surg. , vol.27 , Issue.4 , pp. 438-440
    • Nombela-Franco, L.1    Rodés-Cabau, J.2    Doyle, D.3
  • 84
    • 79952228319 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation using transfemoral/ transsubclavian or transapical approach: 30-day follow-up of the initial 30 patients
    • Witkowski A, Dabrowski M, Chmielak Z et al. Transcatheter aortic valve implantation using transfemoral/ transsubclavian or transapical approach: 30-day follow-up of the initial 30 patients. Kardiol. Pol. 69(2), 105-114 (2011).
    • (2011) Kardiol. Pol. , vol.69 , Issue.2 , pp. 105-114
    • Witkowski, A.1    Dabrowski, M.2    Chmielak, Z.3
  • 85
    • 84857883199 scopus 로고    scopus 로고
    • Transaxillary approach: Short- and mid-term results in a single-center experience
    • Cioni M, Taramasso M, Giacomini A et al. Transaxillary approach: short- and mid-term results in a single-center experience. Innovations (Phila.) 6(6), 361-365 (2011).
    • (2011) Innovations (Phila.) , vol.6 , Issue.6 , pp. 361-365
    • Cioni, M.1    Taramasso, M.2    Giacomini, A.3
  • 86
    • 84861563917 scopus 로고    scopus 로고
    • Direct percutaneous access technique for transaxillary transcatheter aortic valve implantation: 'The Hamburg Sankt Georg approach'
    • Schäfer U, Ho Y, Frerker C et al. Direct percutaneous access technique for transaxillary transcatheter aortic valve implantation: 'the Hamburg Sankt Georg approach'. JACC Cardiovasc. Interv. 5(5), 477-486 (2012).
    • (2012) JACC Cardiovasc. Interv. , vol.5 , Issue.5 , pp. 477-486
    • Schäfer, U.1    Ho, Y.2    Frerker, C.3
  • 87
    • 80052594884 scopus 로고    scopus 로고
    • Percutaneous endoscopic transapical aortic valve implantation: Three experimental transcatheter models
    • Chu MW, Falk V, Mohr FW, Walther T. Percutaneous endoscopic transapical aortic valve implantation: three experimental transcatheter models. Interact. Cardiovasc. Thorac. Surg. 13(3), 251-256 (2011).
    • (2011) Interact. Cardiovasc. Thorac. Surg. , vol.13 , Issue.3 , pp. 251-256
    • Chu, M.W.1    Falk, V.2    Mohr, F.W.3    Walther, T.4
  • 89
    • 77954621513 scopus 로고    scopus 로고
    • Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • Thomas M, Schymik G, Walther T et al. Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 122(1), 62-69 (2010).
    • (2010) Circulation , vol.122 , Issue.1 , pp. 62-69
    • Thomas, M.1    Schymik, G.2    Walther, T.3
  • 90
    • 77649212932 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: Acute and late outcomes of the multicenter Canadian experience
    • Rodés-Cabau J, Webb JG, Cheung A et al. Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. J. Am. Coll. Cardiol. 55(11), 1080-1090 (2010).
    • (2010) J. Am. Coll. Cardiol. , vol.55 , Issue.11 , pp. 1080-1090
    • Rodés-Cabau, J.1    Webb, J.G.2    Cheung, A.3
  • 91
    • 80051751721 scopus 로고    scopus 로고
    • Outcomes and complications of transcatheter aortic valve replacement using a balloon expandable valve according to the Valve Academic Research Consortium (VARC) guidelines
    • Gurvitch R, Toggweiler S, Willson AB et al. Outcomes and complications of transcatheter aortic valve replacement using a balloon expandable valve according to the Valve Academic Research Consortium (VARC) guidelines. EuroIntervention 7(1), 41-48 (2011).
    • (2011) EuroIntervention , vol.7 , Issue.1 , pp. 41-48
    • Gurvitch, R.1    Toggweiler, S.2    Willson, A.B.3
  • 92
    • 80055113552 scopus 로고    scopus 로고
    • The role of sex on VARC outcomes following transcatheter aortic valve implantation with both Edwards SAPIEN ™ and Medtronic CoreValve ReValving System® devices: The Milan registry
    • Buchanan GL, Chieffo A, Montorfano M et al. The role of sex on VARC outcomes following transcatheter aortic valve implantation with both Edwards SAPIEN ™ and Medtronic CoreValve ReValving System® devices: the Milan registry. EuroIntervention 7(5), 556-563 (2011).
    • (2011) EuroIntervention , vol.7 , Issue.5 , pp. 556-563
    • Buchanan, G.L.1    Chieffo, A.2    Montorfano, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.