메뉴 건너뛰기




Volumn 8, Issue 1, 2012, Pages 51-56

First-in-man experience with a new embolic deflection device in transcatheter aortic valve interventions

Author keywords

Cerebral protection device; Stroke; TAVI

Indexed keywords

AGED; AORTA STENOSIS; ARTERY CATHETER; ARTICLE; BRAIN DAMAGE; BRAIN INFARCTION; CLINICAL ARTICLE; DEVICE SAFETY; DIFFUSION WEIGHTED IMAGING; DISEASE SEVERITY; EMBOLIC PROTECTION DEVICE; FEMALE; FEMORAL ARTERY; HUMAN; INVASIVE PROCEDURE; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; OPERATION DURATION; PILOT STUDY; POSTOPERATIVE PERIOD; STROKE; SURGICAL APPROACH; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSIENT ISCHEMIC ATTACK; TREATMENT OUTCOME;

EID: 84865452176     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV8I1A9     Document Type: Article
Times cited : (72)

References (17)
  • 2
    • 67651094208 scopus 로고    scopus 로고
    • Incidence and predictors of stroke associated with percutaneous coronary intervention
    • American College of Cardiology National Cardiovascular Data Registry
    • Aggarwal A, Dai D, Rumsfeld JS, Klein LW, Roe MT; American College of Cardiology National Cardiovascular Data Registry. Incidence and predictors of stroke associated with percutaneous coronary intervention. Am J Cardiol. 2009;104:349-53.
    • (2009) Am J Cardiol , vol.104 , pp. 349-353
    • Aggarwal, A.1    Dai, D.2    Rumsfeld, J.S.3    Klein, L.W.4    Roe, M.T.5
  • 3
    • 0032406941 scopus 로고    scopus 로고
    • Scraping of aortic debris by coronary guiding catheters: A prospective evaluation of 1,000 cases
    • Keeley EC, Grines CL. Scraping of aortic debris by coronary guiding catheters: a prospective evaluation of 1,000 cases. J Am Coll Cardiol. 1998;32:1861-5.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 1861-1865
    • Keeley, E.C.1    Grines, C.L.2
  • 7
    • 79960233361 scopus 로고    scopus 로고
    • Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: Comparison of transfemoral and transapical approaches using Edwards Sapiens valve
    • Astarci P, Glineur D, Kefer J, D'Hoore W, Renkin J, Vanoverschelde JL, El Khoury G, Grandin C. Magnetic resonance imaging evaluation of cerebral embolization during percutaneous aortic valve implantation: comparison of transfemoral and transapical approaches using Edwards Sapiens valve. Eur J Cardiothorac Surg. 2011;40:475-9.
    • (2011) Eur J Cardiothorac Surg , vol.40 , pp. 475-479
    • Astarci, P.1    Glineur, D.2    Kefer, J.3    D'Hoore, W.4    Renkin, J.5    Vanoverschelde, J.L.6    El Khoury, G.7    Grandin, C.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.