메뉴 건너뛰기




Volumn 25, Issue 2, 2012, Pages 174-179

Improved procedural results after CoreValve implantation with the new AccuTrak delivery system

Author keywords

[No Author keywords available]

Indexed keywords

AGED; AORTA VALVE PROSTHESIS; AORTA VALVE REGURGITATION; AORTOGRAPHY; ARTICLE; ARTIFICIAL HEART PACEMAKER; CONTROLLED STUDY; ECHOCARDIOGRAPHY; FEMALE; HEART CATHETER; HEART LEFT VENTRICLE OUTFLOW TRACT; HUMAN; MAJOR CLINICAL STUDY; MALE; OUTCOME ASSESSMENT; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; RETROSPECTIVE STUDY; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 84859701154     PISSN: 08964327     EISSN: 15408183     Source Type: Journal    
DOI: 10.1111/j.1540-8183.2011.00695.x     Document Type: Article
Times cited : (7)

References (16)
  • 1
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • Tamburino C, Capodanno D, Ramondo A, et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 2011; 123: 299-308.
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 2
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    • Abdel-Wahab M, Zahn R, Horack M, et al. Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry. Heart 2011; 97: 899-906.
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3
  • 3
    • 78751655791 scopus 로고    scopus 로고
    • Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the MedtronicCoreValve Bioprosthesis
    • Sherif MA, Abdel-Wahab M, Stöcker B, et al. Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the MedtronicCoreValve Bioprosthesis. J Am Coll Cardiol 2010; 56: 1623-1629.
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1623-1629
    • Sherif, M.A.1    Abdel-Wahab, M.2    Stöcker, B.3
  • 4
    • 77950526783 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-CoreValve® bioprosthesis
    • Jilaihawi H, Chin D, Spyt T, et al. Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-CoreValve® bioprosthesis. Eur Heart J 2010; 31: 857-864.
    • (2010) Eur Heart J , vol.31 , pp. 857-864
    • Jilaihawi, H.1    Chin, D.2    Spyt, T.3
  • 5
    • 79958178970 scopus 로고    scopus 로고
    • Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation
    • Koos R, Mahnken AH, Dohmen G, et al. Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int J Cardiol 2011; 150: 142-145.
    • (2011) Int J Cardiol , vol.150 , pp. 142-145
    • Koos, R.1    Mahnken, A.H.2    Dohmen, G.3
  • 6
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010; 363: 1597-1607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    MacK, M.3
  • 7
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve: Implantation impact of device and annulus discongruence
    • Détaint D, Lepage L, Himbert D, et al. Determinants of significant paravalvular regurgitation after transcatheter aortic valve: Implantation impact of device and annulus discongruence. JACC Cardiovasc Interv 2009; 2 (9): 821-827.
    • (2009) JACC Cardiovasc Interv , vol.2 , Issue.9 , pp. 821-827
    • Détaint, D.1    Lepage, L.2    Himbert, D.3
  • 8
    • 79951581461 scopus 로고    scopus 로고
    • Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation
    • Fraccaro C, Buja G, Tarantini G, et al. Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation. Am J Cardiol 2011; 107: 747-754.
    • (2011) Am J Cardiol , vol.107 , pp. 747-754
    • Fraccaro, C.1    Buja, G.2    Tarantini, G.3
  • 9
    • 78349272042 scopus 로고    scopus 로고
    • Incidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis
    • Ferreira ND, Caeiro D, Adao L, et al. Incidence and predictors of permanent pacemaker requirement after transcatheter aortic valve implantation with a self-expanding bioprosthesis. Pacing Clin Electrophysiol 2010; 33: 1364-1372.
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 1364-1372
    • Ferreira, N.D.1    Caeiro, D.2    Adao, L.3
  • 10
    • 64349084245 scopus 로고    scopus 로고
    • Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis
    • Jilaihawi H, Chin D, Vasa-Nicotera M, et al. Predictors for permanent pacemaker requirement after transcatheter aortic valve implantation with the CoreValve bioprosthesis. Am Heart J 2009; 157: 860-866.
    • (2009) Am Heart J , vol.157 , pp. 860-866
    • Jilaihawi, H.1    Chin, D.2    Vasa-Nicotera, M.3
  • 11
    • 79952738239 scopus 로고    scopus 로고
    • Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: Incidence and contributing factors (the UKCoreValve Collaborative)
    • Khawaja MZ, Rajani R, Cook A, et al. Permanent pacemaker insertion after CoreValve transcatheter aortic valve implantation: Incidence and contributing factors (the UKCoreValve Collaborative). Circulation 2011; 123: 951-960.
    • (2011) Circulation , vol.123 , pp. 951-960
    • Khawaja, M.Z.1    Rajani, R.2    Cook, A.3
  • 12
    • 77649145354 scopus 로고    scopus 로고
    • Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis
    • Baan J Jr, Yong ZY, Koch KT, et al. Factors associated with cardiac conduction disorders and permanent pacemaker implantation after percutaneous aortic valve implantation with the CoreValve prosthesis. Am Heart J 2010; 159: 497-503.
    • (2010) Am Heart J , vol.159 , pp. 497-503
    • Baan Jr., J.1    Yong, Z.Y.2    Koch, K.T.3
  • 13
    • 77955651417 scopus 로고    scopus 로고
    • "Device landing zone" calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI
    • Latsios G, Gerckens U, Buellesfeld L, et al. "Device landing zone" calcification, assessed by MSCT, as a predictive factor for pacemaker implantation after TAVI. Catheter Cardiovasc Interv 2010; 76: 431-439.
    • (2010) Catheter Cardiovasc Interv , vol.76 , pp. 431-439
    • Latsios, G.1    Gerckens, U.2    Buellesfeld, L.3
  • 14
    • 79953856919 scopus 로고    scopus 로고
    • Two-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis
    • Buellesfeld L, Gerckens U, Schuler G, et al. Two-year follow-up of patients undergoing transcatheter aortic valve implantation using a self-expanding valve prosthesis. J Am Coll Cardiol 2011; 57: 1650-1657.
    • (2011) J Am Coll Cardiol , vol.57 , pp. 1650-1657
    • Buellesfeld, L.1    Gerckens, U.2    Schuler, G.3
  • 15
    • 79958176452 scopus 로고    scopus 로고
    • Mechanisms, treatment and course of paravalvular aortic regurgitation after percutaneous implantation of the CoreValve aortic prosthesis
    • Muñoz-García AJ, Alonso-Briales JH, Jiménez-Navarro MF, et al. Mechanisms, treatment and course of paravalvular aortic regurgitation after percutaneous implantation of the CoreValve aortic prosthesis. Int J Cardiol 2011; 149: 389-392.
    • (2011) Int J Cardiol , vol.149 , pp. 389-392
    • Muñoz-García, A.J.1    Alonso-Briales, J.H.2    Jiménez-Navarro, M.F.3
  • 16
    • 49749212248 scopus 로고
    • Left retrograde cardioangiography in acquired cardiac disease: Technique, indications and interpretations in 700 cases
    • Sellers RD, Levy MJ, Amplatz K, et al. Left retrograde cardioangiography in acquired cardiac disease: Technique, indications and interpretations in 700 cases. Am J Cardiol 1964; 14: 437-447.
    • (1964) Am J Cardiol , vol.14 , pp. 437-447
    • Sellers, R.D.1    Levy, M.J.2    Amplatz, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.