메뉴 건너뛰기




Volumn 76, Issue 4, 2010, Pages 602-607

Optimal projection estimation for transcatheter aortic valve implantation based on contrast-aortography: Validation of a prototype software

Author keywords

aortic stenosis; C THV; multi slice computed tomography

Indexed keywords

AGED; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; AORTOGRAPHY; ARTICLE; COHORT ANALYSIS; CONTROLLED STUDY; DATA ANALYSIS SOFTWARE; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; PROSPECTIVE STUDY; RETROSPECTIVE STUDY; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 78649427705     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.22641     Document Type: Article
Times cited : (53)

References (9)
  • 1
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve Revalving System: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N, Grube E, Gerckens U, den Heijer P, Linke A, Luha O, Ramondo A, Ussia G, Wenaweser P, Windecker S, Laborde JC, de Jaegere P, Serruys PW,. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve Revalving System: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention 2008; 4: 242-249.
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den Heijer, P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10    Laborde, J.C.11    De Jaegere, P.12    Serruys, P.W.13
  • 8
    • 74049098326 scopus 로고    scopus 로고
    • Pre-procedural imaging of aortic root orientation and dimensions: Comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography
    • Kurra V, Kapadia SR, Tuzcu EM, Halliburton SS, Svensson L, Roselli EE, Schoenhagen P,. Pre-procedural imaging of aortic root orientation and dimensions: Comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography. JACC Cardiovasc Interv 2010; 3: 105-113.
    • (2010) JACC Cardiovasc Interv , vol.3 , pp. 105-113
    • Kurra, V.1    Kapadia, S.R.2    Tuzcu, E.M.3    Halliburton, S.S.4    Svensson, L.5    Roselli, E.E.6    Schoenhagen, P.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.