메뉴 건너뛰기




Volumn 75, Issue 5, 2010, Pages 784-793

A new technique for vascular access management in transcatheter aortic valve implantation

Author keywords

Aortic valve; Closure devices; Percutaneous; TAVI; Vascular complications

Indexed keywords

AGED; AORTA VALVE REPLACEMENT; ARTERY AVULSION; ARTERY DISSECTION; ARTERY INJURY; ARTERY PERFORATION; ARTICLE; BLEEDING; FEMALE; HEMATOMA; HUMAN; MAJOR CLINICAL STUDY; MALE; SCROTAL HEMATOMA; SURGICAL TECHNIQUE; TRANCATHETER AORTIC VALVE IMPLANTATION; VASCULAR ACCESS DEVICE;

EID: 77950447534     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.22238     Document Type: Article
Times cited : (126)

References (9)
  • 1
    • 34547919242 scopus 로고    scopus 로고
    • Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis
    • Webb JG, Pasupati S, Humphries K, et al. Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation 2007;116:755-763.
    • (2007) Circulation , vol.116 , pp. 755-763
    • Webb, J.G.1    Pasupati, S.2    Humphries, K.3
  • 2
    • 34250815116 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- And current third-generation self-expanding CoreValve prosthesis: Device success and 30-day clinical outcome
    • Grube E, Schuler G, Buellesfeld L, et al. Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- and current third-generation self-expanding CoreValve prosthesis: Device success and 30-day clinical outcome. J Am Coll Cardiol 2007;50:69-76.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 69-76
    • Grube, E.1    Schuler, G.2    Buellesfeld, L.3
  • 3
    • 33644910414 scopus 로고    scopus 로고
    • Treatment of calcific aortic stenosis with the percutaneous heart valve: Mid-term follow- Up from the initial feasibility studies: The French experience
    • Cribier A, Eltchaninoff H, Tron C, et al. Treatment of calcific aortic stenosis with the percutaneous heart valve: Mid-term follow- up from the initial feasibility studies: The French experience. J Am Coll Cardiol 2006;47:1214-1223.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1214-1223
    • Cribier, A.1    Eltchaninoff, H.2    Tron, C.3
  • 4
    • 58249134729 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation: 1-year outcome in 26 patients
    • Ye J, Cheung A, Lichtenstein SV, et al. Transapical transcatheter aortic valve implantation: 1-year outcome in 26 patients. J Thorac Cardiovasc Surg 2009;137:167-173.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 167-173
    • Ye, J.1    Cheung, A.2    Lichtenstein, S.V.3
  • 5
    • 60849122611 scopus 로고    scopus 로고
    • First successful aortic valve implantation with the corevalve revalving system via right subclavian artery access: A case report
    • Ruge H, Lange R, Bleiziffer S, et al. First successful aortic valve implantation with the corevalve revalving system via right subclavian artery access: A case report. Heart Surg Forum 2008;11: E323-E324.
    • (2008) Heart Surg Forum , vol.11
    • Ruge, H.1    Lange, R.2    Bleiziffer, S.3
  • 6
    • 64749091757 scopus 로고    scopus 로고
    • Prevalence of significant peripheral artery disease in patients evaluated for percutaneous aortic valve insertion: Preprocedural assessment with multidetector computed tomography
    • Kurra V, Schoenhagen P, Roselli EE, et al. Prevalence of significant peripheral artery disease in patients evaluated for percutaneous aortic valve insertion: Preprocedural assessment with multidetector computed tomography. J Thorac Cardiovasc Surg 2009; 137:1258-1264.
    • (2009) J Thorac Cardiovasc Surg , vol.137 , pp. 1258-1264
    • Kurra, V.1    Schoenhagen, P.2    Roselli, E.E.3
  • 7
    • 58849144353 scopus 로고    scopus 로고
    • A modified "preclosure" technique after percutaneous aortic valve replacement
    • Kahlert P, Eggebrecht H, Erbel R, Sack S. A modified " preclosure" technique after percutaneous aortic valve replacement. Catheter Cardiovasc Interv 2008;72:877-884.
    • (2008) Catheter Cardiovasc Interv , vol.72 , pp. 877-884
    • Kahlert, P.1    Eggebrecht, H.2    Erbel, R.3    Sack, S.4
  • 8
    • 38549168988 scopus 로고    scopus 로고
    • A randomized trial comparing compression, perclose proglide and angio-seal VIP for arterial closure following percutaneous coronary intervention: The CAP trial
    • Martin JL, Pratsos A, Magargee E, et al. A randomized trial comparing compression, perclose proglide and angio-seal VIP for arterial closure following percutaneous coronary intervention: The CAP trial. Catheter Cardiovasc Interv 2008;71:1-5.
    • (2008) Catheter Cardiovasc Interv , vol.71 , pp. 1-5
    • Martin, J.L.1    Pratsos, A.2    Magargee, E.3
  • 9
    • 34249313684 scopus 로고    scopus 로고
    • Total percutaneous access for endovascular aortic aneurysm repair (Preclose technique)
    • Lee WA, Brown MP, Nelson PR, Huber TS. Total percutaneous access for endovascular aortic aneurysm repair (Preclose technique). J Vasc Surg 2007;45:1095-1101.
    • (2007) J Vasc Surg , vol.45 , pp. 1095-1101
    • Lee, W.A.1    Brown, M.P.2    Nelson, P.R.3    Huber, T.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.