메뉴 건너뛰기




Volumn 7, Issue 1, 2011, Pages 41-48

Outcomes and complications of transcatheter aortic valve replacement using a balloon expandable valve according to the Valve Academic Research Consortium (VARC) guidelines

Author keywords

Aortic stenosis; Complications; Transcatheter aortic valve implantation

Indexed keywords

ACUTE KIDNEY FAILURE; AGED; ANATOMICAL VARIATION; AORTA VALVE PROSTHESIS; AORTA VALVE REGURGITATION; ARTICLE; CEREBROVASCULAR ACCIDENT; COHORT ANALYSIS; CONTROLLED STUDY; DEVICE SAFETY; EQUIPMENT DESIGN; ERYTHROCYTE TRANSFUSION; HUMAN; MAJOR CLINICAL STUDY; OUTCOME ASSESSMENT; POSTOPERATIVE HEMORRHAGE; PRACTICE GUIDELINE; PROSTHESIS FAILURE; SCORING SYSTEM; SURGICAL MORTALITY; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT RESPONSE; AORTA VALVE; BALLOON DILATATION; BLOOD TRANSFUSION; HEART CATHETERIZATION; HEART VALVE REPLACEMENT; INSTRUMENTATION; METHODOLOGY; MORTALITY; POSTOPERATIVE COMPLICATION; STROKE; TREATMENT OUTCOME;

EID: 80051751721     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV7I1A10     Document Type: Article
Times cited : (105)

References (36)
  • 7
    • 33746862304 scopus 로고    scopus 로고
    • Transapical transcatheter aortic valve implantation in humans: Initial clinical experience
    • DOI 10.1161/CIRCULATIONAHA.106.632927, PII 0000301720060808000012
    • Lichtenstein SV, Cheung A, Ye J, Thompson CR, Carere RG, Pasupati S, Webb JG. Transapical transcatheter aortic valve implantation in humans: initial clinical experience. Circulation. 2006;114:591-596. (Pubitemid 44202060)
    • (2006) Circulation , vol.114 , Issue.6 , pp. 591-596
    • Lichtenstein, S.V.1    Cheung, A.2    Ye, J.3    Thompson, C.R.4    Carere, R.G.5    Pasupati, S.6    Webb, J.G.7
  • 10
    • 77954621513 scopus 로고    scopus 로고
    • Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • Thomas M, Schymik G, Walther T, Himbert D, Lefevre T, Treede H, Eggebrecht H, Rubino P, Michev I, Lange R, Anderson WN, Wendler O. Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation. 2010;122:62-69.
    • (2010) Circulation , vol.122 , pp. 62-69
    • Thomas, M.1    Schymik, G.2    Walther, T.3    Himbert, D.4    Lefevre, T.5    Treede, H.6    Eggebrecht, H.7    Rubino, P.8    Michev, I.9    Lange, R.10    Anderson, W.N.11    Wendler, O.12
  • 11
    • 67649576622 scopus 로고    scopus 로고
    • Procedural success and 30-day clinical outcomes after percutaneous aortic valve replacement using current third-generation self-expanding CoreValve prosthesis
    • Tamburino C, Capodanno D, Mule M, Scarabelli M, Cammalleri V, Barbanti M, Calafiore A, Ussia G. Procedural success and 30-day clinical outcomes after percutaneous aortic valve replacement using current third-generation self-expanding CoreValve prosthesis. J Invasive Cardiol. 2009;21:93-98.
    • (2009) J Invasive Cardiol , vol.21 , pp. 93-98
    • Tamburino, C.1    Capodanno, D.2    Mule, M.3    Scarabelli, M.4    Cammalleri, V.5    Barbanti, M.6    Calafiore, A.7    Ussia, G.8
  • 12
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N, Grube E, Gerckens U, den Heijer P, Linke A, Luha O, Ramondo A, Ussia G, Wenaweser P, Windecker S, Laborde JC, de Jaegere P, Serruys PW. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention. 2008;4:242-249.
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den Heijer, P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10    Laborde, J.C.11    De Jaegere, P.12    Serruys, P.W.13
  • 13
    • 77950137108 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for high risk patients with severe aortic stenosis using the Edwards Sapien balloon-expandable bioprosthesis: A single centre study with immediate and medium-term outcomes
    • Osten MD, Feindel C, Greutmann M, Chamberlain K, Meineri M, Rubin B, Mezody M, Ivanov J, Butany J, Horlick EM. Transcatheter aortic valve implantation for high risk patients With severe aortic stenosis using the Edwards Sapien balloon-expandable bioprosthesis: A single centre study with immediate and medium-term outcomes. Catheter Cardiovasc Interv. 2009
    • (2009) Catheter Cardiovasc Interv
    • Osten, M.D.1    Feindel, C.2    Greutmann, M.3    Chamberlain, K.4    Meineri, M.5    Rubin, B.6    Mezody, M.7    Ivanov, J.8    Butany, J.9    Horlick, E.M.10
  • 17
    • 0035014882 scopus 로고    scopus 로고
    • Hemodynamic comparison of second- and third-generation stented bioprostheses in aortic valve replacement
    • DOI 10.1016/S0003-4975(01)02540-1, PII S0003497501025401
    • Jamieson WR, Janusz MT, MacNab J, Henderson C. Hemodynamic comparison of second- and third-generation stented bioprostheses in aortic valve replacement. Ann Thorac Surg. 2001;71:S282-4. (Pubitemid 32436980)
    • (2001) Annals of Thoracic Surgery , vol.71 , Issue.5 SUPPL.
    • Jamieson, W.R.E.1    Janusz, M.T.2    MacNab, J.3    Henderson, C.4
  • 19
    • 67651166960 scopus 로고    scopus 로고
    • Comparison of the Carpentier-Edwards Perimount and St. Jude Medical Epic bioprostheses for aortic valve replacement - A retrospective echocardiographic short-term study
    • Goetzenich A, Langebartels G, Christiansen S, Hatam N, Autschbach R, Dohmen G. Comparison of the Carpentier-Edwards Perimount and St. Jude Medical Epic bioprostheses for aortic valve replacement - a retrospective echocardiographic short-term study. J Card Surg. 2009;24:260-264.
    • (2009) J Card Surg , vol.24 , pp. 260-264
    • Goetzenich, A.1    Langebartels, G.2    Christiansen, S.3    Hatam, N.4    Autschbach, R.5    Dohmen, G.6
  • 22
    • 80055119409 scopus 로고    scopus 로고
    • Determinants and Outcomes of Valvular Dysfunction Following Transcatheter Aortic Valve Implantation
    • AHA 2011 - Abstract
    • Jilaihawi H, Webb JG, Gurvitch R, Ye J, Cheung A, Chin D, Spyt T, Kovac J. Determinants and Outcomes of Valvular Dysfunction Following Transcatheter Aortic Valve Implantation. Circulation. 2010;122:A21129 (AHA 2011 - Abstract).
    • (2010) Circulation , vol.122
    • Jilaihawi, H.1    Webb, J.G.2    Gurvitch, R.3    Ye, J.4    Cheung, A.5    Chin, D.6    Spyt, T.7    Kovac, J.8
  • 30
    • 77953768281 scopus 로고    scopus 로고
    • The effect of the perioperative blood transfusion and blood conservation in cardiac surgery Clinical Practice Guidelines of the Society of Thoracic Surgeons and the Society of Cardiovascular Anesthesiologists upon clinical practices
    • Likosky DS, FitzGerald DC, Groom RC, Jones DK, Baker RA, Shann KG, Mazer CD, Spiess BD, Body SC. The effect of the perioperative blood transfusion and blood conservation in cardiac surgery Clinical Practice Guidelines of the Society of Thoracic Surgeons and the Society of Cardiovascular Anesthesiologists upon clinical practices. J Extra Corpor Technol. 2010;42:114-121.
    • (2010) J Extra Corpor Technol , vol.42 , pp. 114-121
    • Likosky, D.S.1    FitzGerald, D.C.2    Groom, R.C.3    Jones, D.K.4    Baker, R.A.5    Shann, K.G.6    Mazer, C.D.7    Spiess, B.D.8    Body, S.C.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.