메뉴 건너뛰기




Volumn 27, Issue 1, 2013, Pages 184-189

Challenges after the first decade of transcatheter aortic valve replacement: Focus on vascular complications, stroke, and paravalvular leak

Author keywords

3 dimensional transesophageal echocardiography; annular circumference; annular sizing; atrial fibrillation; bleeding; dissection; elliptic aortic annulus; embolic protection device; fistula; hematoma; mortality; multidetector computed tomography; operator experience; paravalvular leak; pseudoaneurysm; renal failure; rupture; sheath diameter; standardized definitions; stroke; transcatheter aortic valve replacement; transfusion; Valve Academic Research Consortium; vascular complications

Indexed keywords

AORTA VALVE PROSTHESIS; ARTICLE; BLOOD TRANSFUSION; BRAIN EMBOLISM; CARDIOVASCULAR DISEASE; CEREBROVASCULAR ACCIDENT; DISEASE SEVERITY; ENDOLEAK; FUNCTIONAL DISEASE; HEART ATRIUM FIBRILLATION; HIGH RISK PATIENT; HUMAN; KIDNEY FAILURE; MULTIDETECTOR COMPUTED TOMOGRAPHY; OVERALL SURVIVAL; PARAVALVULAR LEAK; POSTOPERATIVE COMPLICATION; POSTOPERATIVE HEMORRHAGE; PRIORITY JOURNAL; SURGICAL MORTALITY; SURGICAL PATIENT; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 84872131922     PISSN: 10530770     EISSN: 15328422     Source Type: Journal    
DOI: 10.1053/j.jvca.2012.09.002     Document Type: Review
Times cited : (37)

References (70)
  • 1
    • 84867326319 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation 10-year anniversary: Review of current evidence and clinical implications
    • [Epub ahead of print]
    • P. Généreux, S.J. Head, D.A. Wood Transcatheter aortic valve implantation 10-year anniversary: Review of current evidence and clinical implications Eur Heart J 2012 [Epub ahead of print]
    • (2012) Eur Heart J
    • Généreux, P.1    Head, S.J.2    Wood, D.A.3
  • 2
    • 84867288685 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation 10-year anniversary: Part II: Clinical implications
    • [Epub ahead of print]
    • P. Genereux, S.J. Head, D.A. Wood Transcatheter aortic valve implantation 10-year anniversary: Part II: Clinical implications Eur Heart J 2012 [Epub ahead of print]
    • (2012) Eur Heart J
    • Genereux, P.1    Head, S.J.2    Wood, D.A.3
  • 3
    • 77952582953 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation - Part 1: Development and status of the procedure
    • J. Fassl, J.G. Augoustides Transcatheter aortic valve implantation - Part 1: Development and status of the procedure J Cardiothorac Vasc Anesth 24 2010 498 505
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 498-505
    • Fassl, J.1    Augoustides, J.G.2
  • 4
    • 77955717183 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation - Part 2: Anesthesia management
    • J. Fassl, J.G. Augoustides Transcatheter aortic valve implantation - Part 2: Anesthesia management J Cardiothorac Vasc Anesth 24 2010 691 699
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , pp. 691-699
    • Fassl, J.1    Augoustides, J.G.2
  • 5
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • A. Cribier, H. Eltchaninoff, A. Bash Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description Circulation 106 2002 3006 3008
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 6
    • 84863469191 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement - Part 3: The central role of perioperative transesophageal echocardiography
    • P.A. Patel, J. Fassl, A. Thompson Transcatheter aortic valve replacement - Part 3: The central role of perioperative transesophageal echocardiography J Cardiothorac Vasc Anesth 26 2012 698 710
    • (2012) J Cardiothorac Vasc Anesth , vol.26 , pp. 698-710
    • Patel, P.A.1    Fassl, J.2    Thompson, A.3
  • 7
    • 84864744842 scopus 로고    scopus 로고
    • Current status of transcatheter aortic valve replacement
    • J.G. Webb, D.A. Wood Current status of transcatheter aortic valve replacement J Am Coll Cardiol 60 2012 483 492
    • (2012) J Am Coll Cardiol , vol.60 , pp. 483-492
    • Webb, J.G.1    Wood, D.A.2
  • 8
    • 78651489907 scopus 로고    scopus 로고
    • Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium
    • M.B. Leon, N. Piazza, E. Nikolsky Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: A consensus report from the Valve Academic Research Consortium Eur Heart J 32 2011 205 217
    • (2011) Eur Heart J , vol.32 , pp. 205-217
    • Leon, M.B.1    Piazza, N.2    Nikolsky, E.3
  • 9
    • 84866097368 scopus 로고    scopus 로고
    • Vascular complications after transcatheter aortic valve replacement: Insights from the PARTNER (Placement of AoRTic TraNscathetER Valve) trial
    • P. Genereux, J.G. Webb, L.G. Svensson Vascular complications after transcatheter aortic valve replacement: Insights from the PARTNER (Placement of AoRTic TraNscathetER Valve) trial J Am Coll Cardiol 60 2012 1043 1052
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1043-1052
    • Genereux, P.1    Webb, J.G.2    Svensson, L.G.3
  • 10
    • 84865493818 scopus 로고    scopus 로고
    • Sex differences in mortality after transcatheter aortic valve replacement for severe aortic stenosis
    • K.H. Humphries, S. Toggweiler, J. Rodés-Cabau Sex differences in mortality after transcatheter aortic valve replacement for severe aortic stenosis J Am Coll Cardiol 60 2012 882 886
    • (2012) J Am Coll Cardiol , vol.60 , pp. 882-886
    • Humphries, K.H.1    Toggweiler, S.2    Rodés-Cabau, J.3
  • 11
    • 84855409768 scopus 로고    scopus 로고
    • Optimizing transcatheter aortic valve sizing and minimizing vascular complications
    • C.E. Ruiz Optimizing transcatheter aortic valve sizing and minimizing vascular complications J Am Coll Cardiol 59 2012 128 129
    • (2012) J Am Coll Cardiol , vol.59 , pp. 128-129
    • Ruiz, C.E.1
  • 12
    • 84855403379 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement: Vascular outcomes with a fully percutaneous procedure
    • S. Toggweiler, R. Gurvitch, J. Leipsic Percutaneous aortic valve replacement: Vascular outcomes with a fully percutaneous procedure J Am Coll Cardiol 59 2012 113 118
    • (2012) J Am Coll Cardiol , vol.59 , pp. 113-118
    • Toggweiler, S.1    Gurvitch, R.2    Leipsic, J.3
  • 13
    • 84860389030 scopus 로고    scopus 로고
    • Transfemoral aortic valve implantation: New criteria to predict vascular complications
    • K. Havashida, T. Leievre, B. Chevalier Transfemoral aortic valve implantation: New criteria to predict vascular complications JACC Cardiovasc Interv 4 2011 851 858
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 851-858
    • Havashida, K.1    Leievre, T.2    Chevalier, B.3
  • 14
    • 84855583224 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Assessing the learning curve
    • O.O. Alli, J.D. Booker, R.J. Lennon Transcatheter aortic valve implantation: Assessing the learning curve JACC Cardiovasc Interv 5 2012 72 79
    • (2012) JACC Cardiovasc Interv , vol.5 , pp. 72-79
    • Alli, O.O.1    Booker, J.D.2    Lennon, R.J.3
  • 15
    • 84861155766 scopus 로고    scopus 로고
    • Multisociety (AATS, ACCF, SCAI, and STS) expert consensus statement: Operator and institutional requirements for transcatheter valve repair and replacement, part 1: Transcatheter aortic valve replacement
    • C.L. Tommaso, R.M. Bolman III, T. Feldman Multisociety (AATS, ACCF, SCAI, and STS) expert consensus statement: Operator and institutional requirements for transcatheter valve repair and replacement, part 1: Transcatheter aortic valve replacement J Thorac Cardiovasc Surg 143 2012 1254 1263
    • (2012) J Thorac Cardiovasc Surg , vol.143 , pp. 1254-1263
    • Tommaso, C.L.1    Bolman Iii, R.M.2    Feldman, T.3
  • 16
    • 84864707358 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement with the St Jude Medical Portico Valve: First in-human experience
    • A.B. Willson, J. Rodès-Cabau, D.A. Wood Transcatheter aortic valve replacement with the St Jude Medical Portico Valve: First in-human experience J Am Coll Cardiol 60 2012 581 586
    • (2012) J Am Coll Cardiol , vol.60 , pp. 581-586
    • Willson, A.B.1    Rodès-Cabau, J.2    Wood, D.A.3
  • 17
    • 84870419588 scopus 로고    scopus 로고
    • First in-human valve-in-valve implantation of a 20mm balloon expandable transcatheter heart valve
    • [Epub ahead of print]
    • R.K. Binder, D. Wood, J.G. Webb First in-human valve-in-valve implantation of a 20mm balloon expandable transcatheter heart valve Catheter Cardiovasc Interv 2012 [Epub ahead of print]
    • (2012) Catheter Cardiovasc Interv
    • Binder, R.K.1    Wood, D.2    Webb, J.G.3
  • 18
    • 84859917974 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: The evolution of prostheses, delivery systems and approaches
    • J.G. Webb, R.K. Binder Transcatheter aortic valve implantation: The evolution of prostheses, delivery systems and approaches Arch. Cardiovasc Dis 105 2012 153 159
    • (2012) Arch. Cardiovasc Dis , vol.105 , pp. 153-159
    • Webb, J.G.1    Binder, R.K.2
  • 19
    • 84872168666 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: New developments and upcoming trials
    • C.V. Bourantas, V. Farooq, Y. Onuma Transcatheter aortic valve implantation: New developments and upcoming trials EuroIntervention 8 2012 617 627
    • (2012) EuroIntervention , vol.8 , pp. 617-627
    • Bourantas, C.V.1    Farooq, V.2    Onuma, Y.3
  • 20
    • 84864285663 scopus 로고    scopus 로고
    • Where should transcatheter aortic valve implantation go beyond 2012?
    • R. Dworakowski, P. Maccarthy Where should transcatheter aortic valve implantation go beyond 2012? J Cardiovasc Med (Hagerstown) 13 2012 516 523
    • (2012) J Cardiovasc Med (Hagerstown) , vol.13 , pp. 516-523
    • Dworakowski, R.1    MacCarthy, P.2
  • 21
    • 84860436228 scopus 로고    scopus 로고
    • Registry of transcatheter aortic-valve implantation in high-risk patients
    • M. Gilard, H. Eltchaninoff, B. Iung Registry of transcatheter aortic-valve implantation in high-risk patients N Engl J Med 366 2012 1705 1715
    • (2012) N Engl J Med , vol.366 , pp. 1705-1715
    • Gilard, M.1    Eltchaninoff, H.2    Iung, B.3
  • 22
    • 84862181480 scopus 로고    scopus 로고
    • Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: A weighted meta-analysis of 3,519 patients from 16 studies
    • P. Généreux, S.J. Head, N.M. Van Mieghem Clinical outcomes after transcatheter aortic valve replacement using valve academic research consortium definitions: A weighted meta-analysis of 3,519 patients from 16 studies J Am Coll Cardiol 59 2012 2317 2326
    • (2012) J Am Coll Cardiol , vol.59 , pp. 2317-2326
    • Généreux, P.1    Head, S.J.2    Van Mieghem, N.M.3
  • 23
    • 84255172532 scopus 로고    scopus 로고
    • A high-risk period for cerebrovascular events exists after transcatheter aortic valve implantation
    • E.L. Tay, R. Gurvitch, N. Wijesinghe A high-risk period for cerebrovascular events exists after transcatheter aortic valve implantation JACC Cardiovasc Interv 4 2011 1290 1297
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 1290-1297
    • Tay, E.L.1    Gurvitch, R.2    Wijesinghe, N.3
  • 24
    • 84863338349 scopus 로고    scopus 로고
    • Transcatheter (TAVR) versus surgical (AVR) aortic valve replacement: Occurrence, hazard, risk factors, and consequences of neurologic events in the PARTNER trial
    • D.C. Miller, E.H. Blackstone, M.J. Mack Transcatheter (TAVR) versus surgical (AVR) aortic valve replacement: Occurrence, hazard, risk factors, and consequences of neurologic events in the PARTNER trial J Thorac Cardiovasc Surg 143 2012 832 843
    • (2012) J Thorac Cardiovasc Surg , vol.143 , pp. 832-843
    • Miller, D.C.1    Blackstone, E.H.2    MacK, M.J.3
  • 25
    • 77949918630 scopus 로고    scopus 로고
    • Risk and fate of cerebral embolism after transfemoral aortic valve implantation: A prospective pilot study with diffusion-weighted magnetic resonance imaging
    • A. Ghanem, A. Müller, C.P. Nähle Risk and fate of cerebral embolism after transfemoral aortic valve implantation: A prospective pilot study with diffusion-weighted magnetic resonance imaging J Am Coll Cardiol 55 2010 1427 1432
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1427-1432
    • Ghanem, A.1    Müller, A.2    Nähle, C.P.3
  • 26
    • 77649113087 scopus 로고    scopus 로고
    • Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: A diffusion-weighted magnetic resonance imaging study
    • P. Kahlert, S.C. Knipp, M. Schlamann Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: A diffusion-weighted magnetic resonance imaging study Circulation 121 2010 870 878
    • (2010) Circulation , vol.121 , pp. 870-878
    • Kahlert, P.1    Knipp, S.C.2    Schlamann, M.3
  • 27
    • 78650573226 scopus 로고    scopus 로고
    • Cerebral embolism following transcatheter aortic valve implantation: Comparison of transfemoral and transapical approaches
    • J. Rodés-Cabau, E. Dumont, R.H. Boone Cerebral embolism following transcatheter aortic valve implantation: Comparison of transfemoral and transapical approaches J Am Coll Cardiol 57 2011 18 28
    • (2011) J Am Coll Cardiol , vol.57 , pp. 18-28
    • Rodés-Cabau, J.1    Dumont, E.2    Boone, R.H.3
  • 28
    • 84855347288 scopus 로고    scopus 로고
    • Incidence, predictive factors, and prognostic value of new-onset atrial fibrillation following transcatheter aortic valve implantation
    • I.J. Amat-Santos, J. Rodés-Cabau, M. Urena Incidence, predictive factors, and prognostic value of new-onset atrial fibrillation following transcatheter aortic valve implantation J Am Coll Cardiol 59 2012 178 188
    • (2012) J Am Coll Cardiol , vol.59 , pp. 178-188
    • Amat-Santos, I.J.1    Rodés-Cabau, J.2    Urena, M.3
  • 29
    • 84861203276 scopus 로고    scopus 로고
    • Frequency and causes of stroke during or after transcatheter aortic valve implantation
    • R.J. Nuis, N.M. Van Mieghem, C.J. Schultz Frequency and causes of stroke during or after transcatheter aortic valve implantation Am J Cardiol 109 2012 1637 1643
    • (2012) Am J Cardiol , vol.109 , pp. 1637-1643
    • Nuis, R.J.1    Van Mieghem, N.M.2    Schultz, C.J.3
  • 30
    • 84055212819 scopus 로고    scopus 로고
    • Postprocedural atrial fibrillation after transcatheter aortic valve implantation versus surgical aortic valve replacement
    • L.J. Motloch, S. Reda, D. Rottlaender Postprocedural atrial fibrillation after transcatheter aortic valve implantation versus surgical aortic valve replacement Ann Thorac Surg 93 2012 124 131
    • (2012) Ann Thorac Surg , vol.93 , pp. 124-131
    • Motloch, L.J.1    Reda, S.2    Rottlaender, D.3
  • 31
    • 84865452176 scopus 로고    scopus 로고
    • First in-man experience with a new embolic deflection device in transcatheter aortic valve interventions
    • K. Onsea, P. Agostoni, M. Samim First in-man experience with a new embolic deflection device in transcatheter aortic valve interventions EuroIntervention 8 2012 51 56
    • (2012) EuroIntervention , vol.8 , pp. 51-56
    • Onsea, K.1    Agostoni, P.2    Samim, M.3
  • 32
    • 79959836271 scopus 로고    scopus 로고
    • A percutaneous aortic device for cerebral embolic protection during cardiovascular intervention
    • J.P. Carpenter, J.T. Carpenter, A. Tellez A percutaneous aortic device for cerebral embolic protection during cardiovascular intervention J Vasc Surg 54 2011 174 181
    • (2011) J Vasc Surg , vol.54 , pp. 174-181
    • Carpenter, J.P.1    Carpenter, J.T.2    Tellez, A.3
  • 34
    • 84855313590 scopus 로고    scopus 로고
    • Advances in the management of carotid artery disease: Focus on recent evidence and guidelines
    • J.G. Augoustides Advances in the management of carotid artery disease: Focus on recent evidence and guidelines J Cardiothorac Vasc Anesth 26 2012 166 171
    • (2012) J Cardiothorac Vasc Anesth , vol.26 , pp. 166-171
    • Augoustides, J.G.1
  • 35
    • 84866395864 scopus 로고    scopus 로고
    • The Thrombolysis in Myocardial Infarction (TIMI) study group experience
    • E. Braunwald, M. Sabatine The Thrombolysis In Myocardial Infarction (TIMI) study group experience J Thorac Cardiovasc Surg 144 2012 762 770
    • (2012) J Thorac Cardiovasc Surg , vol.144 , pp. 762-770
    • Braunwald, E.1    Sabatine, M.2
  • 36
    • 84860466759 scopus 로고    scopus 로고
    • Two-year outcomes after transcatheter or surgical aortic-valve replacement
    • S.K. Kodali, M.R. Williams, C.R. Smith Two-year outcomes after transcatheter or surgical aortic-valve replacement N Engl J Med 366 2012 1686 1695
    • (2012) N Engl J Med , vol.366 , pp. 1686-1695
    • Kodali, S.K.1    Williams, M.R.2    Smith, C.R.3
  • 37
    • 79251565276 scopus 로고    scopus 로고
    • Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis
    • C. Tamburino, D. Capodanno, A. Ramondo Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis Circulation 123 2011 299 308
    • (2011) Circulation , vol.123 , pp. 299-308
    • Tamburino, C.1    Capodanno, D.2    Ramondo, A.3
  • 38
    • 79955891681 scopus 로고    scopus 로고
    • Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome Results from the German transcatheter aortic valve interventions registry
    • M. Abdel-Wahab, R. Zahn, M. Horack Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome Results from the German transcatheter aortic valve interventions registry Heart 97 2011 899 906
    • (2011) Heart , vol.97 , pp. 899-906
    • Abdel-Wahab, M.1    Zahn, R.2    Horack, M.3
  • 39
    • 80051670759 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation in patients with severe symptomatic aortic valve stenosis - Predictors of mortality and poor treatment response
    • M. Gotzmann, A. Pljakic, W. Bojara Transcatheter aortic valve implantation in patients with severe symptomatic aortic valve stenosis - Predictors of mortality and poor treatment response Am Heart J 162 2011 238 245
    • (2011) Am Heart J , vol.162 , pp. 238-245
    • Gotzmann, M.1    Pljakic, A.2    Bojara, W.3
  • 40
    • 84859567725 scopus 로고    scopus 로고
    • A practical guide to multimodality imaging of transcatheter aortic valve replacement
    • G.S. Bloomfield, L.D. Gillam, R. Hahn A practical guide to multimodality imaging of transcatheter aortic valve replacement J Am Coll Cardiol Imaging 5 2012 441 455
    • (2012) J Am Coll Cardiol Imaging , vol.5 , pp. 441-455
    • Bloomfield, G.S.1    Gillam, L.D.2    Hahn, R.3
  • 41
    • 84856460597 scopus 로고    scopus 로고
    • Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation
    • K. Takagi, A. Latib, R. Al-Lamee Predictors of moderate-to-severe paravalvular aortic regurgitation immediately after CoreValve implantation and the impact of postdilatation Catheter Cardiovasc Interv 78 2011 432 443
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 432-443
    • Takagi, K.1    Latib, A.2    Al-Lamee, R.3
  • 42
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve implantation: Impact of device and annulus discongruence
    • D. Detaint, L. Lepage, D. Himbert Determinants of significant paravalvular regurgitation after transcatheter aortic valve implantation: Impact of device and annulus discongruence JACC Cardiovasc Interv 2 2009 821 827
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 821-827
    • Detaint, D.1    Lepage, L.2    Himbert, D.3
  • 43
    • 78751655791 scopus 로고    scopus 로고
    • Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis
    • M.A. Sherif, M. Abdel-Wahab, B. Stöcker Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the Medtronic CoreValve bioprosthesis J Am Coll Cardiol 56 2010 1623 1629
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1623-1629
    • Sherif, M.A.1    Abdel-Wahab, M.2    Stöcker, B.3
  • 44
    • 84871878818 scopus 로고    scopus 로고
    • A refined hemispheric model of normal human aortic valve and root geometry
    • [Epub ahead of print]
    • J.S. Rankin, M.C. Bone, P.M. Fries A refined hemispheric model of normal human aortic valve and root geometry J Thorac Cardiovasc Surg 2012 [Epub ahead of print]
    • (2012) J Thorac Cardiovasc Surg
    • Rankin, J.S.1    Bone, M.C.2    Fries, P.M.3
  • 45
    • 81855227692 scopus 로고    scopus 로고
    • Aortic annulus diameter determination by multidetector computed tomography: Reproducibility, applicability, and implications for transcatheter aortic valve implantation
    • R. Gurvitch, J.G. Webb, R. Yuan Aortic annulus diameter determination by multidetector computed tomography: Reproducibility, applicability, and implications for transcatheter aortic valve implantation JACC Cardiovasc Interv 4 2011 1235 1245
    • (2011) JACC Cardiovasc Interv , vol.4 , pp. 1235-1245
    • Gurvitch, R.1    Webb, J.G.2    Yuan, R.3
  • 46
    • 84869494217 scopus 로고    scopus 로고
    • Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation
    • [Epub ahead of print]
    • O. Husser, S. Rauch, D.H. Endemann Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation Catheter Cardiovasc Interv 2012 [Epub ahead of print]
    • (2012) Catheter Cardiovasc Interv
    • Husser, O.1    Rauch, S.2    Endemann, D.H.3
  • 47
    • 84870327852 scopus 로고    scopus 로고
    • Multidetector computed tomography is equivalent to transesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation
    • [Epub ahead of print]
    • J. Rixe, A. Schuhbaeck, C. Liebetrau Multidetector computed tomography is equivalent to transesophageal echocardiography for the assessment of the aortic annulus before transcatheter aortic valve implantation Eur Radiol 2012 [Epub ahead of print]
    • (2012) Eur Radiol
    • Rixe, J.1    Schuhbaeck, A.2    Liebetrau, C.3
  • 48
    • 84859160648 scopus 로고    scopus 로고
    • 3-Dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: A multicenter retrospective analysis
    • A.B. Willson, J.G. Webb, T.M. LaBounty 3-Dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: A multicenter retrospective analysis J Am Coll Cardiol 59 2012 1287 1294
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1287-1294
    • Willson, A.B.1    Webb, J.G.2    Labounty, T.M.3
  • 49
    • 84864831418 scopus 로고    scopus 로고
    • Everything is better in 3D: Why transcatheter aortic valve replacement should be guided by multidetector computed tomography
    • C.J. Hague, J. Leipsic Everything is better in 3D: Why transcatheter aortic valve replacement should be guided by multidetector computed tomography Future Cardiol 8 2012 485 487
    • (2012) Future Cardiol , vol.8 , pp. 485-487
    • Hague, C.J.1    Leipsic, J.2
  • 50
    • 84859164235 scopus 로고    scopus 로고
    • Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation
    • H. Jilaihawi, M. Kashif, G. Fontana Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation J Am Coll Cardiol 59 2012 1275 1286
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1275-1286
    • Jilaihawi, H.1    Kashif, M.2    Fontana, G.3
  • 51
    • 84866386726 scopus 로고    scopus 로고
    • Transcatheter aortic valve replacement using DynaCT
    • K. Maeda, T. Kuratani, K. Torikai Transcatheter aortic valve replacement using DynaCT J Card Surg 27 2012 551 553
    • (2012) J Card Surg , vol.27 , pp. 551-553
    • Maeda, K.1    Kuratani, T.2    Torikai, K.3
  • 52
    • 84860822227 scopus 로고    scopus 로고
    • Prediction of optimal deployment projection for transcatheter aortic valve replacement: Angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography
    • R.K. Binder, J. Leipsic, D. Wood Prediction of optimal deployment projection for transcatheter aortic valve replacement: Angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography Circ Cardiovasc Interv 5 2012 247 252
    • (2012) Circ Cardiovasc Interv , vol.5 , pp. 247-252
    • Binder, R.K.1    Leipsic, J.2    Wood, D.3
  • 53
    • 84879692516 scopus 로고    scopus 로고
    • Optimization of acquisition and contrast injection protocol for C-arm CT imaging in transcatheter aortic valve implantation: Initial experience in a swine model
    • [Epub ahead of print]
    • U.D. Numburi, S.R. Kapadia, P. Schoenhagen Optimization of acquisition and contrast injection protocol for C-arm CT imaging in transcatheter aortic valve implantation: Initial experience in a swine model Int J Cardiovasc Imaging 2012 [Epub ahead of print]
    • (2012) Int J Cardiovasc Imaging
    • Numburi, U.D.1    Kapadia, S.R.2    Schoenhagen, P.3
  • 54
    • 84869875174 scopus 로고    scopus 로고
    • Use of cardiovascular magnetic resonance imaging for TAVR assessment in patients with bioprosthetic aortic valves: Comparison with computed tomography
    • [Epub ahead of print]
    • M.A. Quail, J. Nordmeyer, S. Schievano Use of cardiovascular magnetic resonance imaging for TAVR assessment in patients with bioprosthetic aortic valves: Comparison with computed tomography Eur J Radiol 2012 [Epub ahead of print]
    • (2012) Eur J Radiol
    • Quail, M.A.1    Nordmeyer, J.2    Schievano, S.3
  • 55
    • 84867515040 scopus 로고    scopus 로고
    • Prosthesis/annulus discongruence assessed by three-dimensional transesophageal echocardiography: A predictor of significant paravalvular aortic regurgitation after transcatheter aortic valve implantation
    • [Epub ahead of print]
    • N. Santos, J.A. de Agustin, C. Almeria Prosthesis/annulus discongruence assessed by three-dimensional transesophageal echocardiography: A predictor of significant paravalvular aortic regurgitation after transcatheter aortic valve implantation Eur Heart J Cardiovasc Imaging 2012 [Epub ahead of print]
    • (2012) Eur Heart J Cardiovasc Imaging
    • Santos, N.1    De Agustin, J.A.2    Almeria, C.3
  • 56
    • 80052673562 scopus 로고    scopus 로고
    • Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation
    • E. Altiok, R. Koos, J. Schröder Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation Heart 97 2011 1578 1584
    • (2011) Heart , vol.97 , pp. 1578-1584
    • Altiok, E.1    Koos, R.2    Schröder, J.3
  • 57
    • 84862226341 scopus 로고    scopus 로고
    • Feasibility and accuracy of 3D TEE versus CT for the evaluation of aortic valve annulus to left main ostium distance before transcatheter aortic valve implantation
    • G. Tamborini, L. Fusini, P. Gripari Feasibility and accuracy of 3D TEE versus CT for the evaluation of aortic valve annulus to left main ostium distance before transcatheter aortic valve implantation JACC Cardiovasc Imaging 5 2012 579 588
    • (2012) JACC Cardiovasc Imaging , vol.5 , pp. 579-588
    • Tamborini, G.1    Fusini, L.2    Gripari, P.3
  • 58
    • 84864373136 scopus 로고    scopus 로고
    • Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation
    • P. Gripari, S.H. Ewe, L. Fusini Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation Heart 98 2012 1229 1236
    • (2012) Heart , vol.98 , pp. 1229-1236
    • Gripari, P.1    Ewe, S.H.2    Fusini, L.3
  • 59
    • 84868618362 scopus 로고    scopus 로고
    • Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root
    • P. Blanke, J. Reinöhl, C. Schlensak Prosthesis oversizing in balloon-expandable transcatheter aortic valve implantation is associated with contained rupture of the aortic root Circ Cardiovasc Interv 5 2012 540 548
    • (2012) Circ Cardiovasc Interv , vol.5 , pp. 540-548
    • Blanke, P.1    Reinöhl, J.2    Schlensak, C.3
  • 60
    • 84868193971 scopus 로고    scopus 로고
    • Long-term outcome of patients with moderate and severe prosthetic aortic valve regurgitation after transcatheter aortic valve implantation
    • [Epub ahead of print]
    • M. Gotzmann, M. Korten, W. Bojara Long-term outcome of patients with moderate and severe prosthetic aortic valve regurgitation after transcatheter aortic valve implantation Am J Cardiol 2012 [Epub ahead of print]
    • (2012) Am J Cardiol
    • Gotzmann, M.1    Korten, M.2    Bojara, W.3
  • 61
    • 84865848038 scopus 로고    scopus 로고
    • Cerebral embolization during transcatheter aortic valve implantation: A transcranial Doppler study
    • P. Kahlert, F. Al-Rashid, P. Döttger Cerebral embolization during transcatheter aortic valve implantation: A transcranial Doppler study Circulation 126 2012 1245 1255
    • (2012) Circulation , vol.126 , pp. 1245-1255
    • Kahlert, P.1    Al-Rashid, F.2    Döttger, P.3
  • 62
    • 84860381746 scopus 로고    scopus 로고
    • Risk of stroke after transcatheter aortic valve implantation (TAVI): A meta-analysis of 10,037 published patients
    • H. Eggebrecht, A. Schmermund, T. Voigtländer Risk of stroke after transcatheter aortic valve implantation (TAVI): A meta-analysis of 10,037 published patients EuroIntervention 8 2012 129 138
    • (2012) EuroIntervention , vol.8 , pp. 129-138
    • Eggebrecht, H.1    Schmermund, A.2    Voigtländer, T.3
  • 63
    • 84872147680 scopus 로고    scopus 로고
    • Stroke complicating transcatheter aortic valve implantation: Incidence, risk factors, and outcome
    • [Epub ahead of print]
    • R.R. Leker, R. Eichel, A. Verber Stroke complicating transcatheter aortic valve implantation: Incidence, risk factors, and outcome Int J Stroke 2012 [Epub ahead of print]
    • (2012) Int J Stroke
    • Leker, R.R.1    Eichel, R.2    Verber, A.3
  • 64
    • 84860381196 scopus 로고    scopus 로고
    • Embolic protection devices during TAVI - The "proof of the pudding."
    • N.M. Van Mieghem, P.W. Serruys Embolic protection devices during TAVI - The "proof of the pudding." EuroIntervention 8 2012 25 29
    • (2012) EuroIntervention , vol.8 , pp. 25-29
    • Van Mieghem, N.M.1    Serruys, P.W.2
  • 65
    • 79961042044 scopus 로고    scopus 로고
    • Cerebral embolic exposure during transfemoral and transapical transcatheter aortic valve replacement
    • W.Y. Szeto, J.G. Augoustides, N.D. Desai Cerebral embolic exposure during transfemoral and transapical transcatheter aortic valve replacement J Card Surg 26 2011 348 354
    • (2011) J Card Surg , vol.26 , pp. 348-354
    • Szeto, W.Y.1    Augoustides, J.G.2    Desai, N.D.3
  • 66
    • 84867744419 scopus 로고    scopus 로고
    • Current update of cerebral embolic protection devices
    • [Epub ahead of print]
    • A.Y. Mousa, J.E. Campbell, A.F. AbuRahma Current update of cerebral embolic protection devices J Vasc Surg 2012 [Epub ahead of print]
    • (2012) J Vasc Surg
    • Mousa, A.Y.1    Campbell, J.E.2    Aburahma, A.F.3
  • 67
    • 84862533949 scopus 로고    scopus 로고
    • From pressure overload to volume overload: Aortic regurgitation after transcatheter aortic valve implantation
    • M. Gotzmann, M. Lindstaedt, A. Mügge From pressure overload to volume overload: Aortic regurgitation after transcatheter aortic valve implantation Am Heart J 163 2012 903 911
    • (2012) Am Heart J , vol.163 , pp. 903-911
    • Gotzmann, M.1    Lindstaedt, M.2    Mügge, A.3
  • 68
    • 84872144910 scopus 로고    scopus 로고
    • Impact of residual regurgitation after aortic valve replacement
    • S. Sponga, J. Perron, F. Dagenais Impact of residual regurgitation after aortic valve replacement Eur J Cardiothorac Surg 42 2012 486 492
    • (2012) Eur J Cardiothorac Surg , vol.42 , pp. 486-492
    • Sponga, S.1    Perron, J.2    Dagenais, F.3
  • 69
    • 75749129479 scopus 로고    scopus 로고
    • Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography
    • A.C. Ng, V. Delgado, F. van der Kley Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography Circ Cardiovasc Imaging 3 2010 94 102
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 94-102
    • Ng, A.C.1    Delgado, V.2    Van Der Kley, F.3
  • 70
    • 84894368614 scopus 로고    scopus 로고
    • Device closure of paravalvular leaks following transcatheter aortic valve replacement with the Edwards Sapien valve
    • [Epub ahead of print]
    • B. Whisenant, K. Jones, K.D. Horton Device closure of paravalvular leaks following transcatheter aortic valve replacement with the Edwards Sapien valve Catheter Cardiovasc Interv 2012 [Epub ahead of print]
    • (2012) Catheter Cardiovasc Interv
    • Whisenant, B.1    Jones, K.2    Horton, K.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.