메뉴 건너뛰기




Volumn 97, Issue 11, 2011, Pages 899-906

Aortic regurgitation after transcatheter aortic valve implantation: Incidence and early outcome. Results from the German transcatheter aortic valve interventions registry

Author keywords

[No Author keywords available]

Indexed keywords

AGED; AORTA STENOSIS; AORTA VALVE PROSTHESIS; AORTA VALVE REGURGITATION; ARTICLE; CARDIOGENIC SHOCK; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; FORWARD HEART FAILURE; GENDER; GERMANY; HUMAN; INCIDENCE; KIDNEY FAILURE; MAJOR CLINICAL STUDY; MALE; MORTALITY; MULTICENTER STUDY; POSTOPERATIVE PERIOD; PREDICTION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RESPIRATORY FAILURE; RISK FACTOR; SURGICAL RISK; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TREATMENT OUTCOME;

EID: 79955891681     PISSN: 13556037     EISSN: 1468201X     Source Type: Journal    
DOI: 10.1136/hrt.2010.217158     Document Type: Article
Times cited : (457)

References (33)
  • 1
    • 47049087117 scopus 로고    scopus 로고
    • United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex
    • Svensson LG, Dewey T, Kapadia S, et al. United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex. Ann Thorac Surg 2008;86:46-55.
    • (2008) Ann Thorac Surg , vol.86 , pp. 46-55
    • Svensson, L.G.1    Dewey, T.2    Kapadia, S.3
  • 4
    • 34748910153 scopus 로고    scopus 로고
    • Transapical minimally invasive aortic valve implantation: Multicenter experience
    • Walther T, Simon P, Dewey T, et al. Transapical minimally invasive aortic valve implantation: multicenter experience. Circulation 2007;116:I240-5.
    • (2007) Circulation , vol.116
    • Walther, T.1    Simon, P.2    Dewey, T.3
  • 5
    • 77649212932 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: Acute and late outcomes of the multicenter canadian experience
    • Rodes-Cabau J, Webb JG, Cheung A, et al. Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter canadian experience. J Am Coll Cardiol 2010;55:1080-90.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1080-1090
    • Rodes-Cabau, J.1    Webb, J.G.2    Cheung, A.3
  • 6
    • 0032790897 scopus 로고    scopus 로고
    • Natural history of early aortic paraprosthetic regurgitation: A five- year follow-up
    • DOI 10.1016/S0002-8703(99)70124-9
    • Rallidis LS, Moyssakis IE, Ikonomidis I, et al. Natural history of early aortic paraprosthetic regurgitation: a five-year follow-up. Am Heart J 1999;138:351-7. (Pubitemid 29379690)
    • (1999) American Heart Journal , vol.138 , Issue.2 I , pp. 351-357
    • Pallidis, L.S.1    Moyssakis, I.E.2    Ikonomidis, I.3    Nihoyannopoulos, P.4
  • 7
    • 59049100066 scopus 로고    scopus 로고
    • Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve Revalving System aortic valve bioprosthesis
    • De Jaegere PP, Piazza N, Galema TW, et al. Early echocardiographic evaluation following percutaneous implantation with the self-expanding CoreValve Revalving System aortic valve bioprosthesis. EuroIntervention 2008;4:351-7.
    • (2008) EuroIntervention , vol.4 , pp. 351-357
    • De Jaegere, P.P.1    Piazza, N.2    Galema, T.W.3
  • 8
    • 78651506594 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: First results from a multi-centre real-world registry
    • On behalf of the german transcatheter aortic valve interventions - registry investigators
    • Zahn R, Gerckens U, Grube E, et al; On behalf of the german transcatheter aortic valve interventions - registry investigators. Transcatheter aortic valve implantation: first results from a multi-centre real-world registry. Eur Heart J 2011;32:198-304.
    • (2011) Eur Heart J , vol.32 , pp. 198-304
    • Zahn, R.1    Gerckens, U.2    Grube, E.3
  • 9
    • 0034792414 scopus 로고    scopus 로고
    • Risk factors for early mortality after valve surgery in Europe in the 1990s: Lessons from the EuroSCORE pilot program
    • Roques F, Nashef SA, Michel P. Risk factors for early mortality after valve surgery in Europe in the 1990s: lessons from the EuroSCORE pilot program. J Heart Valve Dis 2001;10:572-7.
    • (2001) J Heart Valve Dis , vol.10 , pp. 572-577
    • Roques, F.1    Nashef, S.A.2    Michel, P.3
  • 10
    • 45649083670 scopus 로고    scopus 로고
    • Transcatheter valve implantation for patients with aortic stenosis: A position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
    • Vahanian A, Alfieri OR, Al-Attar N, et al. Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur J Cardiothorac Surg 2008;34:1-8.
    • (2008) Eur J Cardiothorac Surg , vol.34 , pp. 1-8
    • Vahanian, A.1    Alfieri, O.R.2    Al-Attar, N.3
  • 11
    • 70349404319 scopus 로고    scopus 로고
    • Positionspapier zur kathetergeführten Aortenklappenintervention
    • Figulla HR, Cremer J, Walther T, et al. Positionspapier zur kathetergeführten Aortenklappenintervention. Kardiologe 2009;3:199-206.
    • (2009) Kardiologe , vol.3 , pp. 199-206
    • Figulla, H.R.1    Cremer, J.2    Walther, T.3
  • 13
    • 60849121992 scopus 로고    scopus 로고
    • Progress and current status of percutaneous aortic valve replacement: Results of three device generations of the CoreValve Revalving system
    • Grube E, Buellesfeld L, Mueller R, et al. Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system. Circ Cardiovasc Interv 2008;1:167-75.
    • (2008) Circ Cardiovasc Interv , vol.1 , pp. 167-175
    • Grube, E.1    Buellesfeld, L.2    Mueller, R.3
  • 15
    • 67649532220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Impact on clinical and valve-related outcomes
    • Webb JG, Altwegg L, Boone RH, et al. Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes. Circulation 2009;119:3009-16.
    • (2009) Circulation , vol.119 , pp. 3009-3016
    • Webb, J.G.1    Altwegg, L.2    Boone, R.H.3
  • 16
    • 49749212248 scopus 로고
    • Left retrograde cardioangiography in acquired cardiac disease: Technic, indications and interpretations in 700 cases
    • Sellers RD, Levy MJ, Amplatz K, et al. Left retrograde cardioangiography in acquired cardiac disease: technic, indications and interpretations in 700 cases. Am J Cardiol 1964;14:437-47.
    • (1964) Am J Cardiol , vol.14 , pp. 437-447
    • Sellers, R.D.1    Levy, M.J.2    Amplatz, K.3
  • 17
    • 78651468809 scopus 로고    scopus 로고
    • Percutaneous transarterial aortic valve implantation: What do we know?
    • Webb J, Cribier A. Percutaneous transarterial aortic valve implantation: what do we know? Eur Heart J 2011;32:140-7.
    • (2011) Eur Heart J , vol.32 , pp. 140-147
    • Webb, J.1    Cribier, A.2
  • 18
    • 77954621513 scopus 로고    scopus 로고
    • Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve
    • Thomas M, Schymik G, Walther T, et al. Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: A European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 2010;122:62-9.
    • (2010) Circulation , vol.122 , pp. 62-69
    • Thomas, M.1    Schymik, G.2    Walther, T.3
  • 19
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • PARTNER Trial Investigators
    • Leon MB, Smith CR, Mack M, et al; PARTNER Trial Investigators. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010;363:1597-607.
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    Mack, M.3
  • 20
    • 65149088915 scopus 로고    scopus 로고
    • Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis
    • Clavel MA, Webb JG, Pibarot P, et al. Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis. J Am Coll Cardiol 2009;53:1883-91.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1883-1891
    • Clavel, M.A.1    Webb, J.G.2    Pibarot, P.3
  • 21
    • 77951718294 scopus 로고    scopus 로고
    • Paravalvular regurgitation one year after transcatheter aortic valve implantation
    • Rajani R, Kakad M, Khawaja MZ, et al. Paravalvular regurgitation one year after transcatheter aortic valve implantation. Catheter Cardiovasc Interv 2010;75:868-72.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 868-872
    • Rajani, R.1    Kakad, M.2    Khawaja, M.Z.3
  • 22
    • 77951744201 scopus 로고    scopus 로고
    • Leaks and the "great ship" TAVI
    • Block PC. Leaks and the "great ship" TAVI. Catheter Cardiovasc Interv 2010;75:873-4.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 873-874
    • Block, P.C.1
  • 23
    • 38349136447 scopus 로고    scopus 로고
    • Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults
    • Zegdi R, Ciobotaru V, Noghin M, et al. Is it reasonable to treat all calcified stenotic aortic valves with a valved stent? Results from a human anatomic study in adults. J Am Coll Cardiol 2008;51:579-84.
    • (2008) J Am Coll Cardiol , vol.51 , pp. 579-584
    • Zegdi, R.1    Ciobotaru, V.2    Noghin, M.3
  • 24
    • 77953454377 scopus 로고    scopus 로고
    • Correlates of valvular ossification in patients with aortic valve stenosis
    • Ing SW, Mohler Iii ER, Putt ME, et al. Correlates of valvular ossification in patients with aortic valve stenosis. Clin Transl Sci 2009;2:431-5.
    • (2009) Clin Transl Sci , vol.2 , pp. 431-435
    • Ing, S.W.1    Mohler III, E.R.2    Putt, M.E.3
  • 26
    • 73649096192 scopus 로고    scopus 로고
    • Multimodal assessment of the aortic annulus diameter: Implications for transcatheter aortic valve implantation
    • Messika-Zeitoun D, Serfaty JM, Brochet E, et al. Multimodal assessment of the aortic annulus diameter: implications for transcatheter aortic valve implantation. J Am Coll Cardiol 2010;55:186-94.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 186-194
    • Messika-Zeitoun, D.1    Serfaty, J.M.2    Brochet, E.3
  • 27
    • 75749129479 scopus 로고    scopus 로고
    • Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography
    • Ng AC, Delgado V, van der Kley F, et al. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging 2010;3:94-102.
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 94-102
    • Ng, A.C.1    Delgado, V.2    Van Der Kley, F.3
  • 28
    • 33746393625 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch: Definition, clinical impact, and prevention
    • DOI 10.1136/hrt.2005.067363
    • Pibarot P, Dumesnil JG. Prosthesis-patient mismatch: definition, clinical impact, and prevention. Heart 2006;92:1022-9. (Pubitemid 44125207)
    • (2006) Heart , vol.92 , Issue.8 , pp. 1022-1029
    • Pibarot, P.1    Dumesnil, J.G.2
  • 29
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve implantation: Impact of device and annulus discongruence
    • Détaint D, Lepage L, Himbert D, et al. Determinants of significant paravalvular regurgitation after transcatheter aortic valve implantation: impact of device and annulus discongruence. JACC Cardiovasc Interv 2009;2:821-7.
    • (2009) JACC Cardiovasc Interv , vol.2 , pp. 821-827
    • Détaint, D.1    Lepage, L.2    Himbert, D.3
  • 30
    • 0030248226 scopus 로고    scopus 로고
    • Guidelines for reporting morbidity and mortality after cardiac valvular operations. The American association for thoracic surgery and the Society of Thoracic Surgeons, Ad Hoc Liaison Committee for standardizing definitions of prosthetic heart valve morbidity
    • Edmunds LH Jr, Clark RE, Cohn LH, et al. Guidelines for reporting morbidity and mortality after cardiac valvular operations. The American association for thoracic surgery and the Society of Thoracic Surgeons, Ad Hoc Liaison Committee for standardizing definitions of prosthetic heart valve morbidity. J Thorac Cardiovasc Surg 1996;62:932-5.
    • (1996) J Thorac Cardiovasc Surg , vol.62 , pp. 932-935
    • Edmunds Jr., L.H.1    Clark, R.E.2    Cohn, L.H.3
  • 31
    • 71649107560 scopus 로고    scopus 로고
    • Energy loss due to paravalvular leak with transcatheter aortic valve implantation
    • Azadani AN, Jaussaud N, Matthews PB, et al. Energy loss due to paravalvular leak with transcatheter aortic valve implantation. Ann Thorac Surg 2009;88:1857-63.
    • (2009) Ann Thorac Surg , vol.88 , pp. 1857-1863
    • Azadani, A.N.1    Jaussaud, N.2    Matthews, P.B.3
  • 32
    • 80051714169 scopus 로고    scopus 로고
    • Hemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using cardiovascular magnetic resonance
    • In press
    • Sherif MA, Abdel-Wahab M, Beurich HW, et al. Hemodynamic evaluation of aortic regurgitation after transcatheter aortic valve implantation using cardiovascular magnetic resonance. EuroIntervention In press.
    • EuroIntervention
    • Sherif, M.A.1    Abdel-Wahab, M.2    Beurich, H.W.3
  • 33
    • 78751655791 scopus 로고    scopus 로고
    • Anatomical and procedural predictors of paravalvular regurgitation after implantation of the Medtronic CoreValve bioprosthesis
    • Sherif MA, Abdel-Wahab M, Stöcker B, et al. Anatomical and procedural predictors of paravalvular regurgitation after implantation of the Medtronic CoreValve bioprosthesis. J Am Coll Cardiol 2010;56:1623-9.
    • (2010) J Am Coll Cardiol , vol.56 , pp. 1623-1629
    • Sherif, M.A.1    Abdel-Wahab, M.2    Stöcker, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.