메뉴 건너뛰기




Volumn 56, Issue 20, 2010, Pages 1623-1629

Anatomic and procedural predictors of paravalvular aortic regurgitation after implantation of the medtronic CoreValve bioprosthesis

Author keywords

Aortic regurgitation; CoreValve; Predictors; Transcatheter aortic valve implantation

Indexed keywords

AGED; ANGIOCARDIOGRAPHY; AORTA VALVE REGURGITATION; AORTA VALVE REPLACEMENT; AORTOGRAPHY; ARTICLE; ASCENDING AORTA; CLINICAL ARTICLE; FEMALE; HEART LEFT VENTRICLE OUTFLOW TRACT; HUMAN; MALE; PARAVALVULAR AORTIC REGURGITATION; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY; SURGICAL APPROACH; TRANSCATHETER AORTIC VALVE IMPLANTATION; TRANSFEMORAL ROUTE; TRANSTHORACIC ECHOCARDIOGRAPHY; AORTA VALVE STENOSIS; BIOPROSTHESIS; COMPARATIVE STUDY; FOLLOW UP; HEART VALVE REPLACEMENT; HOSPITALIZATION; PREDICTIVE VALUE; PROGNOSIS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 78751655791     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2010.06.035     Document Type: Article
Times cited : (223)

References (13)
  • 1
    • 0032790897 scopus 로고    scopus 로고
    • Natural history of early aortic paraprosthetic regurgitation: A five- year follow-up
    • DOI 10.1016/S0002-8703(99)70124-9
    • Rallidis LS, Moyssakis IE, Ikonomidis I, Nihoyannopoulos P. Natural history of early aortic paraprosthetic regurgitation: a five-year followup. Am Heart J 1999;138:351-7. (Pubitemid 29379690)
    • (1999) American Heart Journal , vol.138 , Issue.2 , pp. 351-357
    • Pallidis, L.S.1    Moyssakis, I.E.2    Ikonomidis, I.3    Nihoyannopoulos, P.4
  • 3
    • 49749212248 scopus 로고
    • Left retrograde cardioangiography in acquired cardiac disease: Technique, indications, and interpretations in 700 cases
    • Sellers RD, Levy MJ, Amplatz K, Lillehei CW. Left retrograde cardioangiography in acquired cardiac disease: technique, indications, and interpretations in 700 cases. Am J Cardiol 1964;14:437-47.
    • (1964) Am J Cardiol , vol.14 , pp. 437-447
    • Sellers, R.D.1    Levy, M.J.2    Amplatz, K.3    Lillehei, C.W.4
  • 4
    • 0022649162 scopus 로고
    • Determination of the stenotic aortic valve area in adults using Doppler echocardiography
    • Otto CM, Pearlman AS, Comess KA, Reamer RP, Janko CL, Huntsman LL. Determination of the stenotic aortic valve area in adults using Doppler echocardiography. J Am Coll Cardiol 1986; 7:509 -17. (Pubitemid 16164377)
    • (1986) Journal of the American College of Cardiology , vol.7 , Issue.3 , pp. 509-517
    • Otto, C.M.1    Pearlman, A.S.2    Comess, K.A.3
  • 7
    • 48949098859 scopus 로고    scopus 로고
    • 2008 focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients with Valvular Heart Disease)
    • Bonow RO, Carabello BA, Chatterjee K, et al. 2008 focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease). J Am Coll Cardiol 2008;52:e1-142.
    • (2008) J Am Coll Cardiol , vol.52
    • Bonow, R.O.1    Carabello, B.A.2    Chatterjee, K.3
  • 9
    • 75349102866 scopus 로고    scopus 로고
    • Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System
    • Piazza N, Otten A, Schultz C, et al. Adherence to patient selection criteria in patients undergoing transcatheter aortic valve implantation with the 18F CoreValve ReValving System. Heart 2010;96:19 -26.
    • (2010) Heart , vol.96 , pp. 19-26
    • Piazza, N.1    Otten, A.2    Schultz, C.3
  • 10
    • 70349396032 scopus 로고    scopus 로고
    • Determinants of significant paravalvular regurgitation after transcatheter aortic valve: Implantation impact of device and annulus discongruence
    • Detaint D, Lepage L, Himbert D, et al. Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. J Am Coll Cardiol Intv 2009;2:821-7.
    • (2009) J Am Coll Cardiol Intv , vol.2 , pp. 821-827
    • Detaint, D.1    Lepage, L.2    Himbert, D.3
  • 11
    • 77950526783 scopus 로고    scopus 로고
    • Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic CoreValve bioprosthesis
    • Jilaihawi H, Chin D, Spyt T, et al. Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic CoreValve bioprosthesis. Eur Heart J 2010;31:857-64.
    • (2010) Eur Heart J , vol.31 , pp. 857-864
    • Jilaihawi, H.1    Chin, D.2    Spyt, T.3
  • 12
    • 58649088446 scopus 로고    scopus 로고
    • Echocardiography for transcatheter aortic valve implantation
    • Chin D. Echocardiography for transcatheter aortic valve implantation. Eur J Echocardiogr 2009;10:i21-9.
    • (2009) Eur J Echocardiogr , vol.10
    • Chin, D.1
  • 13
    • 71649107560 scopus 로고    scopus 로고
    • Energy loss due to paravalvular leak with transcatheter aortic valve implantation
    • Azadani AN, Jaussaud N, Matthews PB, et al. Energy loss due to paravalvular leak with transcatheter aortic valve implantation. Ann Thorac Surg 2009;88:1857-63.
    • (2009) Ann Thorac Surg , vol.88 , pp. 1857-1863
    • Azadani, A.N.1    Jaussaud, N.2    Matthews, P.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.