메뉴 건너뛰기




Volumn 5, Issue 6, 2012, Pages 579-588

Feasibility and accuracy of 3DTEE versus CT for the evaluation of aortic valve annulus to left main ostium distance before transcatheter aortic valve implantation

Author keywords

3 dimensional transesophageal echocardiography; left main coronary artery occlusion; transcatheter aortic valve implantation

Indexed keywords

AGED; AORTA VALVE; AORTIC VALVE ANNULUS; ARTICLE; COMPUTED TOMOGRAPHY SCANNER; CONTROLLED STUDY; CORONARY ARTERY; DIAGNOSTIC ACCURACY; FEASIBILITY STUDY; FEMALE; HUMAN; INTERMETHOD COMPARISON; LEFT MAIN CORONARY OSTIUM; MAJOR CLINICAL STUDY; MALE; MULTIDETECTOR COMPUTED TOMOGRAPHY; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; THREE DIMENSIONAL ECHOCARDIOGRAPHY; THREE DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 84862226341     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2012.02.012     Document Type: Article
Times cited : (64)

References (23)
  • 1
    • 67649532220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Impact on clinical and valve-related outcomes
    • J.G. Webb, L. Altwegg, R.H. Boone Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes Circulation 119 2009 3009 3016
    • (2009) Circulation , vol.119 , pp. 3009-3016
    • Webb, J.G.1    Altwegg, L.2    Boone, R.H.3
  • 2
    • 65149095001 scopus 로고    scopus 로고
    • Outcomes and safety of percutaneous aortic valve replacement
    • A. Zajarias, A.G. Cribier Outcomes and safety of percutaneous aortic valve replacement J Am Coll Cardiol 53 2009 1829 1836
    • (2009) J Am Coll Cardiol , vol.53 , pp. 1829-1836
    • Zajarias, A.1    Cribier, A.G.2
  • 4
    • 43049170511 scopus 로고    scopus 로고
    • Transapical minimally invasive aortic valve implantation; The initial 50 patients
    • T. Walther, V. Falk, J. Kempfert Transapical minimally invasive aortic valve implantation; the initial 50 patients Eur J Cardiothorac Surg 33 2008 983 988
    • (2008) Eur J Cardiothorac Surg , vol.33 , pp. 983-988
    • Walther, T.1    Falk, V.2    Kempfert, J.3
  • 8
    • 77952027747 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function
    • V. Delgado, A.C. Ng, N.R. van de Veire Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function Eur Heart J 31 2010 1114 1123
    • (2010) Eur Heart J , vol.31 , pp. 1114-1123
    • Delgado, V.1    Ng, A.C.2    Van De Veire, N.R.3
  • 9
    • 79958173080 scopus 로고    scopus 로고
    • Feasibility and accuracy of a comprehensive multidetector computed tomography acquisition for patients referred for balloon-expandable transcatheter aortic valve implantation
    • G. Pontone, D. Andreini, A.L. Bartorelli Feasibility and accuracy of a comprehensive multidetector computed tomography acquisition for patients referred for balloon-expandable transcatheter aortic valve implantation Am Heart J 161 2011 1106 1113
    • (2011) Am Heart J , vol.161 , pp. 1106-1113
    • Pontone, G.1    Andreini, D.2    Bartorelli, A.L.3
  • 10
    • 80052673562 scopus 로고    scopus 로고
    • Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation
    • E. Altiok, R. Koos, J. Schroder Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation Heart 97 2011 1578 1584
    • (2011) Heart , vol.97 , pp. 1578-1584
    • Altiok, E.1    Koos, R.2    Schroder, J.3
  • 11
    • 75749129479 scopus 로고    scopus 로고
    • Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography
    • A.C. Ng, V. Delgado, F. van der Kley Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography Circ Cardiovasc Imaging 3 2010 94 102
    • (2010) Circ Cardiovasc Imaging , vol.3 , pp. 94-102
    • Ng, A.C.1    Delgado, V.2    Van Der Kley, F.3
  • 12
    • 80051971967 scopus 로고    scopus 로고
    • EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease
    • J.L. Zamorano, L.P. Badano, C. Bruce EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease Eur J Echocardiogr 12 2011 557 584
    • (2011) Eur J Echocardiogr , vol.12 , pp. 557-584
    • Zamorano, J.L.1    Badano, L.P.2    Bruce, C.3
  • 13
    • 48949098859 scopus 로고    scopus 로고
    • 2008 Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients with Valvular Heart Disease)
    • R.O. Bonow, B.A. Carabello, K. Chatterjee 2008 Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) J Am Coll Cardiol 52 2008 e1 e142
    • (2008) J Am Coll Cardiol , vol.52
    • Bonow, R.O.1    Carabello, B.A.2    Chatterjee, K.3
  • 15
    • 77953762087 scopus 로고    scopus 로고
    • Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement
    • S. Bleiziffer, A. Ali, I.M. Hettich Impact of the indexed effective orifice area on mid-term cardiac-related mortality after aortic valve replacement Heart 96 2010 865 871
    • (2010) Heart , vol.96 , pp. 865-871
    • Bleiziffer, S.1    Ali, A.2    Hettich, I.M.3
  • 16
    • 0034332788 scopus 로고    scopus 로고
    • Hemodynamic performance during maximum exercise in adult patients with the Ross operation and comparison with normal controls and patients with aortic bioprotheses
    • P. Pibarot, J.G. Dumesnil, M. Briand, I. Laforest, P. Cartier Hemodynamic performance during maximum exercise in adult patients with the Ross operation and comparison with normal controls and patients with aortic bioprotheses Am J Cardiol 86 2000 982 988
    • (2000) Am J Cardiol , vol.86 , pp. 982-988
    • Pibarot, P.1    Dumesnil, J.G.2    Briand, M.3    Laforest, I.4    Cartier, P.5
  • 17
    • 80054993345 scopus 로고    scopus 로고
    • Hemodynamic and clinical impact of prosthesis-patient mismatch after transcatheter aortic valve implantation
    • S.H. Ewe, M. Muratori, V. Delgado Hemodynamic and clinical impact of prosthesis-patient mismatch after transcatheter aortic valve implantation J Am Coll Cardiol 58 2011 1910 1918
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1910-1918
    • Ewe, S.H.1    Muratori, M.2    Delgado, V.3
  • 18
    • 62949095752 scopus 로고    scopus 로고
    • Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve
    • N. Piazza, J.P. De, C. Schultz, A.E. Becker, P.W. Serruys, R.H. Anderson Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve Circ Cardiovasc Interv 1 2008 74 81
    • (2008) Circ Cardiovasc Interv , vol.1 , pp. 74-81
    • Piazza, N.1    De, J.P.2    Schultz, C.3    Becker, A.E.4    Serruys, P.W.5    Anderson, R.H.6
  • 20
    • 69449104659 scopus 로고    scopus 로고
    • Effects of percutaneous aortic valve replacement on coronary blood flow assessed with transesophageal Doppler echocardiography in patients with severe aortic stenosis
    • I. Ben-Dor, S.A. Goldstein, R. Waksman Effects of percutaneous aortic valve replacement on coronary blood flow assessed with transesophageal Doppler echocardiography in patients with severe aortic stenosis Am J Cardiol 104 2009 850 855
    • (2009) Am J Cardiol , vol.104 , pp. 850-855
    • Ben-Dor, I.1    Goldstein, S.A.2    Waksman, R.3
  • 21
    • 68249157954 scopus 로고    scopus 로고
    • Successful percutaneous management of left main trunk occlusion during percutaneous aortic valve replacement
    • S.R. Kapadia, L. Svensson, E.M. Tuzcu Successful percutaneous management of left main trunk occlusion during percutaneous aortic valve replacement Catheter Cardiovasc Interv 73 2009 966 972
    • (2009) Catheter Cardiovasc Interv , vol.73 , pp. 966-972
    • Kapadia, S.R.1    Svensson, L.2    Tuzcu, E.M.3
  • 22
    • 33748755448 scopus 로고    scopus 로고
    • Comparison of Feasibility and Accuracy of Transthoracic Echocardiography Versus Computed Tomography in Patients With Known Ascending Aortic Aneurysm
    • DOI 10.1016/j.amjcard.2006.04.043, PII S000291490601191X
    • G. Tamborini, C.A. Galli, A. Maltagliati Comparison of feasibility and accuracy of transthoracic echocardiography versus computed tomography in patients with known ascending aortic aneurysm Am J Cardiol 98 2006 966 969 (Pubitemid 44402273)
    • (2006) American Journal of Cardiology , vol.98 , Issue.7 , pp. 966-969
    • Tamborini, G.1    Galli, C.A.2    Maltagliati, A.3    Andreini, D.4    Pontone, G.5    Quaglia, C.6    Ballerini, G.7    Pepi, M.8
  • 23
    • 78649717552 scopus 로고    scopus 로고
    • Assessment of the aortic root using real-time 3D transesophageal echocardiography
    • K. Otani, M. Takeuchi, K. Kaku Assessment of the aortic root using real-time 3D transesophageal echocardiography Circ J 74 2010 2649 2657
    • (2010) Circ J , vol.74 , pp. 2649-2657
    • Otani, K.1    Takeuchi, M.2    Kaku, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.